Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DI&C”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

An approach to light distribution for the calibration of high energy physics calorimeters

In high energy physics experiments, calorimeters are calibrated to produce precise and accurate results. Laser light can be used for calibration when the detectors are sensitive to photons in that particular energy range, which is often the case. Moreover, it is not unusual that detection systems consist of hundreds of channels that have to be calibrated independently, which produce stringent requirements on the light distribution system in terms of temporal and spatial stability, energy distribution and timing. Furthermore, the economic factor and the ease of production have to be taken into account. Overall, we present a prototype light distribution system, based on a series of optical beamsplitters, developed for the Muon g-2 experiment at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design, implementation, and performance of the LZ calibration systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of the cosmic ray tagger system for the ICARUS detector at FNAL

The ICARUS-T600 Liquid Argon Time Projection Chamber is operating at Fermilab at shallow depth and thus exposed to a high flux of cosmic rays that can fake neutrino interactions. A cosmic ray tagging (CRT) system (∼ 1100 m 2 ), surrounding the cryostat with two layers of fiber embedded plastic scintillators, was developed to mitigate the cosmic ray induced background. Using nanosecond-level timing information, the CRT can distinguish incoming cosmic rays from outgoing particles from neutrino interactions in the TPC. In this paper an overview of the CRT system, its installation and commissioning at Fermilab, and its performance are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark Energy Survey Year 3 results: Cosmological constraints from galaxy clustering and galaxy-galaxy lensing using the MagLim lens sample

The cosmological information extracted from photometric surveys is most robust when multiple probes of the large scale structure of the Universe are used. Two of the most sensitive probes are the clustering of galaxies and the tangential shear of background galaxy shapes produced by those foreground galaxies, so-called galaxy-galaxy lensing. Combining the measurements of these two two-point functions leads to cosmological constraints that are independent of the way galaxies trace matter (the galaxy bias factor). The optimal choice of foreground, or lens, galaxies is governed by the joint, but conflicting requirements to obtain accurate redshift information and large statistics. We present cosmological results from the full 5000 deg 2 of the Dark Energy Survey’s first three years of observations (Y3) combining those two-point functions, using for the first time a magnitude-limited lens sample (MagLim) of 11 million galaxies, especially selected to optimize such combination, and 100 million background shapes. We consider two flat cosmological models, the Standard Model with dark energy and cold dark matter ( Λ CDM ) a variation with a free parameter for the dark energy equation of state ( w CDM ). Both models are marginalized over 25 astrophysical and systematic nuisance parameters. In Λ CDM we obtain for the matter density Ω m = 0.320 - 0.034 + 0.041 and for the clustering amplitude S 8 ≡ σ 8 ( Ω m / 0.3 ) 0.5 = 0.778 - 0.031 + 0.037 , at 68% C.L. The latter is only 1 σ smaller than the prediction in this model informed by measurements of the cosmic microwave background by the Planck satellite. In w CDM we find Ω m = 0.32 - 0.046 + 0.044 , S 8 = 0.777 - 0.051 + 0.049 and dark energy equation of state w = - 1.031 - 0.379 + 0.218 . We find that including smaller scales, while marginalizing over nonlinear galaxy bias, improves the constraining power in the Ω m - S 8 plane by 31% and in the Ω m - w plane by 41% while yielding consistent cosmological parameters from those in the linear bias case. These results are combined with those from cosmic shear in a companion paper to present full DES-Y3 constraints from the three two-point functions ( 3 × 2 pt ).

79 ASTRONOMY AND ASTROPHYSICS↗

Initial measurement of reactor antineutrino oscillation at SNO+

The SNO+ collaboration reports its first spectral analysis of long-baseline reactor antineutrino oscillation using 114 tonne-years of data. Fitting the neutrino oscillation probability to the observed energy spectrum yields constraints on the neutrino mass-squared difference Δ$m^2_{21}$. In the ranges allowed by previous measurements, the best-fit Δ$m^2_{21}$ is ($8.85^{+1.10}_{-1.33}$) × 10 -5 eV 2 . This measurement is continuing in the next phases of SNO+ and is expected to surpass the present global precision on Δ$m^2_{21}$ with about three years of data. In the following, we first describe the configuration of the SNO+ detector when it was partially filled with scintillator, and a characterization of the detector response using intrinsic radioactivity. Next, we detail the event selection and expectations for reactor IBDs and (α, n) reactions. Then, we present the results of an energy spectrum analysis using 114 tonne-years of data. We conclude with prospects of future results from the SNO+ detector, which has been operating fully-filled with 780 tonnes of scintillator

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of CMOS Sensors for HEP with a US-based foundry

We will present a program to establish the first development and manufacturing of HEP-specific sensors monolithically integrated into a standard CMOS process using a US-based foundry. In collaboration with several US universities the project aims to develop Monolithic Active Pixel Sensors (MAPS) designs implemented in the 90 nm technology node, including simple test structures and multi-pixel arrays, and monolithic CMOS sensors with readout integrated circuits, perform detailed characterization of the detector prototypes and quantify their performance for HEP applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Scoping Efforts for a Plant-Wide Digital Infrastructure Modernization Business Case Study

This research report describes the preparatory efforts to perform a BCA on an expanded set of digital upgrades envisioned for implementation at the Luminant?s Comanche Peak nuclear plant. It captures efforts to scope the digital upgrade effort to enable performance of the BCA. The final BCA will be the subject of a subsequent report. LWRS pilot research in this area is intended to enable this effort and to provide a roadmap to others to follow. INL appreciates the Luminant?s participation in this research.

99 GENERAL AND MISCELLANEOUS↗

Measurement of the positive muon anomalous magnetic moment to 127 ppb

A new measurement of the magnetic anomaly $a_μ$ of the positive muon is presented based on data taken from 2020 to 2023 by the Muon $g-2$ Experiment at Fermi National Accelerator Laboratory (FNAL). This dataset contains over 2.5 times the total statistics of our previous results. From the ratio of the precession frequencies for muons and protons in our storage ring magnetic field, together with precisely known ratios of fundamental constants, we determine $a_μ = 116\,592\,0710(162) \times 10^{-12}$ (139 ppb) for the new datasets, and $a_μ = 116\,592\,0705(148) \times 10^{-12}$ (127 ppb) when combined with our previous results. The new experimental world average, dominated by the measurements at FNAL, is $a_μ(\text{exp}) =116\,592\,0715(145) \times 10^{-12}$ (124 ppb). The measurements at FNAL have improved the precision on the world average by over a factor of four.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗