Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DECOMPRESSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Fifteen-minute Extravehicular Activity Prebreathe Protocol Using NASA's Exploration Atmosphere (8.2 psia/ 34% 02)

A TBDM DCS probability model based on an existing biophysical model of inert gas bubble growth provides significant prediction and goodness-of-fit with 84 cases of DCS in 668 human altitude exposures. 2. Model predictions suggest that 15-minute O2 prebreathe protocols used in conjunction with suit ports and an 8.2 psi, 34% O2, 66% N2 atmosphere may enable rapid EVA capability for future exploration missions with the risk of DCS ≤ 12%.  EVA could begin immediately at 6.0 psi, with crewmembers decreasing suit pressure to 4.3 psi after completing the 15-minute in-suit prebreathe. 3. Model predictions suggest that intermittent recompression during exploration EVA may reduce decompression stress by 1.8% to 2.3% for 6 hours of total EVA time. Savings in gas consumables and crew time may be accumulated by abbreviating the EVA suit N2 purge to 2 minutes (20% N2) compared with 8 minutes (5% N2) at the expense of an increase in estimated decompression risk of up to 2.4% for an 8-hour EVA.  Increased DCS risk could be offset by IR or by spending additional time at 6 psi at the beginning of the EVA.  Savings of 0.48 lb of gas and 6 minutes per person per EVA corresponds to more than 31 hours of crew time and 1800 lb of gas and tankage under the Constellation lunar architecture. 6. Further research is needed to characterize and optimize breathing mixtures and intermittent recompression across the range of environments and operational conditions in which astronauts will live and work during future exploration missions. 7. Development of exploration prebreathe protocols will begin with definition of acceptable risk, followed by development of protocols based on models such as ours, and, ultimately, validation of protocols through ground trials before operational implementation.

Abercromby, Andrew F. J.↗

Modeling of Particle Acceleration at Multiple Shocks Via Diffusive Shock Acceleration: Preliminary Results

We present preliminary results from a model that diffusively accelerates particles at multiple shocks. Our basic approach is related to box models (Protheroe and Stanev, 1998; Moraal and Axford, 1983; Ball and Kirk, 1992; Drury et al., 1999) in which a distribution of particles is diffusively accelerated inside the box while simultaneously experiencing decompression through adiabatic expansion and losses from the convection and diffusion of particles outside the box (Melrose and Pope, 1993; Zank et al., 2000). We adiabatically decompress the accelerated particle distribution between each shock by either the method explored in Melrose and Pope (1993) and Pope and Melrose (1994) or by the approach set forth in Zank et al. (2000) where we solve the transport equation by a method analogous to operator splitting. The second method incorporates the additional loss terms of convection and diffusion and allows for the use of a variable time between shocks. We use a maximum injection energy (Emax) appropriate for quasi-parallel and quasi-perpendicular shocks (Zank et al., 2000, 2006; Dosch and Shalchi, 2010) and provide a preliminary application of the diffusive acceleration of particles by multiple shocks with frequencies appropriate for solar maximum (i.e., a non-Markovian process).

Parker, Linda Neergaard↗

Modeling of Particle Acceleration at Multiple Shocks via Diffusive Shock Acceleration: Preliminary Results

Successful forecasting of energetic particle events in space weather models require algorithms for correctly predicting the spectrum of ions accelerated from a background population of charged particles. We present preliminary results from a model that diffusively accelerates particles at multiple shocks. Our basic approach is related to box models in which a distribution of particles is diffusively accelerated inside the box while simultaneously experiencing decompression through adiabatic expansion and losses from the convection and diffusion of particles outside the box. We adiabatically decompress the accelerated particle distribution between each shock by either the method explored in Melrose and Pope (1993) and Pope and Melrose (1994) or by the approach set forth in Zank et al. (2000) where we solve the transport equation by a method analogous to operator splitting. The second method incorporates the additional loss terms of convection and diffusion and allows for the use of a variable time between shocks. We use a maximum injection energy (E(sub max)) appropriate for quasi-parallel and quasi-perpendicular shocks and provide a preliminary application of the diffusive acceleration of particles by multiple shocks with frequencies appropriate for solar maximum (i.e., a non-Markovian process).

Parker, L. Neergaard↗

Initial Incidence of White Matter Hyperintensities on MRI in Astronauts

Introduction: Previous literature has described the increase in white matter hyperintensity (WMH) burden associated with hypobaric exposure in the U-2 and altitude chamber operating personnel. Although astronauts have similar hypobaric exposure pressures to the U2 pilot population, astronauts have far fewer exposures and each exposure would be associated with a much lower level of decompression stress due to rigorous countermeasures to prevent decompression sickness. Therefore, we postulated that the WMH burden in the astronaut population would be less than in U2 pilots. Methods: Twenty-one post-flight de-identified astronaut MRIs (5 mm slice thickness FLAIR sequences) were evaluated for WMH count and volume. The only additional data provided was an age range of the astronauts (43-57) and if they had ever performed an EVA (13 yes, 8 no). Results: WMH count in these 21 astronaut MRI was 21.0 +/- 24.8 (mean+/- SD) and volume was 0.382 +/- 0.602 ml, which was significantly higher than previously published results for the U2 pilots. No significant differences between EVA and no EVA groups existed. Age range of astronaut population is not directly comparable to the U2 population. Discussion: With significantly less frequent (sometimes none) and less stressful hypobaric exposures, yet a much higher incidence of increased WMH, this indicates the possibility of additional mechanisms beyond hypobaric exposure. This increase unlikely to be attributable just to the differences in age between astronauts and U2 pilots. Forward work includes continuing review of post-flight MRI and evaluation of pre to post flight MRI changes if available. Data mining for potential WMH risk factors includes collection of age, sex, spaceflight experience, EVA hours, other hypobaric exposures, hyperoxic exposures, radiation, high performance aircraft experience and past medical history. Finally, neurocognitive and vision/eye results will be evaluated for any evidence of impairment linked to increased WMH.

Norcross, Jason↗

Evidence Report: Risk of Hypobaric Hypoxia from the Exploration Atmosphere

Extravehicular activity (EVA) is at the core of a manned space exploration program. Some elements of exploration may be safely and effectively performed by robots, but certain critical elements will require the trained, assertive, and reasoning mind of a human crewmember. To effectively use these skills, NASA needs a safe, effective, and efficient EVA component integrated into the human exploration program. The EVA preparation time should be minimized and the suit pressure should be low to accommodate EVA tasks without causing undue fatigue, physical discomfort, or suit-related trauma. Commissioned in 2005, the Exploration Atmospheres Working Group (EAWG) had the primary goal of recommending to NASA an internal environment that allowed efficient and repetitive EVAs for missions that were to be enabled by the former Constellation Program. At the conclusion of the EAWG meeting, the 8.0 psia and 32% oxygen (O2) environment were recommended for EVA-intensive phases of missions. After re-evaluation in 2012, the 8/32 environment was altered to 8.2 psia and 34% O2 to reduce the hypoxic stress to a crewmember. These two small changes increase alveolar O2 pressure by 11 mmHg, which is expected to significantly benefit crewmembers. The 8.2/34 environment (inspired O2 pressure = 128 mmHg) is also physiologically equivalent to the staged decompression atmosphere of 10.2 psia / 26.5% O2 (inspired O2 pressure = 127 mmHg) used on 34 different shuttle missions for approximately a week each flight. As a result of selecting this internal environment, NASA gains the capability for efficient EVA with low risk of decompression sickness (DCS), but not without incurring the additional negative stimulus of hypobaric hypoxia to the already physiologically challenging spaceflight environment. This report provides a review of the human health and performance risks associated with the use of the 8.2 psia / 34% O2 environment during spaceflight. Of most concern are the potential effects on the central nervous system (CNS), including increased intracranial pressure, visual impairment, sensorimotor dysfunction, and oxidative damage. Other areas of focus include validation of the DCS mitigation strategy, incidence and treatment of transient acute mountain sickness (AMS), development of new exercise countermeasure protocols, effective food preparation at 8.2 psia, assurance of quality sleep, and prevention of suit-induced injury. Although missions proposing to use an 8.2/34 environment are still years away, it is recommended that these studies begin early enough to ensure that the correct decisions pertaining to vehicle design, mission operational concepts, and human health countermeasures are appropriately informed.

Norcross, Jason R.↗

Constraints on Mantle Plume Melting Conditions in the Martian Mantle Based on Improved Melting Phase Relationships of Olivine-Phyric Shergottite Yamato 980459

Martian meteorite Yamato 980459 (hereafter Y98) is an olivine-phyric shergottite that has been interpreted as closely approximating a martian mantle melt [1-4], making it an important constraint on adiabatic decompression melting models. It has long been recognized that low pressure melting of the Y98 composition occurs at extremely high temperatures relative to martian basalts (1430 degC at 1 bar), which caused great difficulties in a previous attempt to explain Y98 magma generation via a mantle plume model [2]. However, previous studies of the phase diagram were limited to pressures of 2 GPa and less [2, 5], whereas decompression melting in the present-day martian mantle occurs at pressures of 3-7 GPa, with the shallow boundary of the melt production zone occurring just below the base of the thermal lithosphere [6]. Recent experimental work has now extended our knowledge of the Y98 melting phase relationships to 8 GPa. In light of this improved petrological knowledge, we are therefore reassessing the constraints that Y98 imposes on melting conditions in martian mantle plumes. Two recently discovered olivine- phyric shergottites, Northwest Africa (NWA) 5789 and NWA 6234, may also be primary melts from the martian mantle [7, 8]. However, these latter meteorites have not been the subject of detailed experimental petrology studies, so we focus here on Y98.

Kiefer, Walter S.↗

Results of a 3-day Pilot Study to Validate Planetary Prebreathe Protocols Using a 56.5 kPa 34% O2, 66% N2 Saturation Cabin Atmosphere

INTRODUCTION: Apollo missions used 100% O2 cabin atmospheres which effectively eliminated the risk of decompression sickness (DCS) during extravehicular activities (EVAs, ‘spacewalks’); however, this atmosphere presented a flammability risk that is no longer acceptable to NASA. Denitrogenation prebreathe protocols used to mitigate DCS risk for Space Shuttle and International Space Station EVAs are validated for the microgravity environment, but the significantly increased risk of DCS during equivalent ambulatory surface EVAs make these protocols inapplicable to planetary/Lunar missions. An “exploration atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA for future Moon and Mars missions as a compromise that balances subsequent pre-EVA prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. Prebreathe validation studies was initiated utilizing a three-story 6m diameter hypobaric chamber at NASA’s Johnson Space Center. Here, we report the results of a 3-day human-in-the-loop system checkout. METHODS: Six volunteers acclimated to the 56.6kPa/34% O2 66% N2 environment for 48hrs prior to conducting a 20-minute prebreathe and a 6-hour simulated EVA at 34kPa/85% O2 / 15% N2. The EVA simulation was designed to include tasks that are physically and ergonomically representative of future planetary EVAs. Decompression stress was evaluated by serial doppler and echocardiographs, as well as by clinical features of DCS signs/symptoms. RESULTS AND DISCUSSION: Preliminary data analysis noted venous gas emboli (VGE) in 3 of 6 subjects, with peak Grade II VGE by Doppler and peak E-B score of 5 by cardiac ultrasonography. No volunteers were diagnosed with DCS during this initial test. No acute hypoxic symptoms were noted. Musculoskeletal and gastrointestinal complaints were noted, likely associated with the exercise load and the food system. Validation of exploration prebreathe protocols has since been initiated with an 11-day saturation test using the same facility and protocol.

Alejandro Garbino↗

Evaluation of Planetary Extravehicular Activity Prebreathe Protocols using a 56.5 kPa, 34% O2, 66% N2 Saturation Cabin Atmosphere in an 11-day Hypobaric Hypoxia Study

INTRODUCTION: Apollo missions used 100% O2 cabin atmospheres which effectively eliminated the risk of decompression sickness (DCS) during Lunar extravehicular activities (EVAs, ‘spacewalks’); however, this atmosphere presented a flammability risk that is no longer acceptable to NASA. Denitrogenation prebreathe protocols used to mitigate DCS risk for Space Shuttle and International Space Station EVAs are validated for the microgravity environment, but the significantly increased risk of DCS during equivalent ambulatory surface EVAs make these protocols inapplicable to planetary/Lunar missions. A cabin/vehicle “Exploration Atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA for future Moon and Mars missions as a compromise that balances subsequent pre-EVA prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. Prebreathe validation studies were initiated utilizing a three-story 6m diameter hypobaric chamber at NASA’s Johnson Space Center. Here, we report the results of a 11-day human-in-the-loop system checkout. METHODS: Six volunteers lived in a hyboparic chamber for 11 days with an ‘exploration atmosphere’ of 56.6kPa/34% O2 66% N2. Subjects acclimated to the exploration atmosphere for 48hrs and thereafter participated in five 6-hour simulated EVAs at 34kPa/85% O2 / 15% N2 over the course of 11 days. Prior to each simulated EVA, subjects underwent a 20-minute prebreathe at 85% O2. The EVA simulation was designed to include tasks that are physically and ergonomically representative of future planetary EVAs, proportionate to the subject’s VO2max. Decompression stress was evaluated during the simulated EVA by serial doppler and echocardiographs alternating every 15min, as well as clinical monitoring for DCS signs/symptoms. RESULTS AND DISCUSSION: Venous gas emboli (VGE) were present in 3 of 6 subjects during EVAs, with peak Grade II VGE as evaluated by Doppler and a peak Eftedal-Brubakk score of 5 by cardiac ultrasonography. Two cases of DCS were diagnosed during the 11-day test chamber. No acute hypoxic symptoms were noted. Musculoskeletal and gastrointestinal complaints were noted, likely associated with the exercise load and the food system. Two cases of DCS (8%) does not cross either accept or reject pre-test criterion, so an additional study is planned for 2023 to meet our pre-test thresholds.

Alejandro Garbino↗

Assimilation of Reconstructed Radiances from IASI Principal Component Scores into the GEOS-ADAS

Hyperspectral Infrared sounders such as IASI, AIRS, and CrIS have long been an integral part of radiance assimilation in numerical weather prediction (NWP), providing vertical profiles of water vapor and temperature information. Principal Component Scores (PCS) are a lossy form of compression that retains most information, such as temperature and moisture, by using a large training set of atmospheric profiles. However, PCS may not well represent profiles which are rare events, such as volcanic eruptions, and drops some sources of random noise. There has been an increased interest in the use of PCS as EUMETSAT plans to distribute future geostationary sounder radiances from MTG-IRS via PCS only. NWP centers use two approaches to deal with PCS: direct assimilation of the PCS by modifying the radiative transfer model to produce PCS and the associated Jacobians, or a simpler approach of decompressing the PCS and reconstructing the radiances back into channel space to allow assimilating radiances without modifications to the data assimilation system. EUMETSAT has developed a PCS product for IASI that has been operational since 2011. We utilize this product opting for the simpler approach, decompressing IASI PCS into channel space, and assimilating those radiances using the GEOS-ADAS. We then compare this with a control using the standard IASI radiance product. Resulting differences in global forecast statistics, differences in Forecast Sensitivity to Observation Impact, along with implications for implementation and quality control are discussed.

Bryan M. Karpowicz↗

Human Spaceflight Applications of Novel Miniature X-Ray Technologies

INTRODUCTION: Radiography (XR) has long been a cornerstone of terrestrial medical imaging, though it has not yet been used in the spaceflight environment. Medical systems for human spaceflight missions are constrained by mass, volume, and power, and until recently, XR systems have been considered too large and power-consuming for spaceflight diagnostic and therapeutic applications. However, the rise of commercial spaceflight and NASA’s refocused efforts on returning crews to the Moon for long-duration missions have introduced a higher degree of medical risk to human spaceflight and require a re-evaluation when optimizing medical system design. Over the last decade, XR devices have miniaturized while maintaining good diagnostic and therapeutic sensitivity and specificity, making new in-flight medical and non-medical XR applications a possibility. Initial research identified several medical conditions where miniature XR would be beneficial for the diagnosis and/or management of medical conditions arising in space, though a more in-depth analysis is required to identify whether XR may add value to the management of such conditions. With this presentation, we aim to introduce the potential utility of miniature XR, review prior work highlighting where XR may be beneficial, and evaluate how miniature XR may reduce medical risk in human spaceflight missions. METHODS: IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a risk assessment tool developed by NASA to advance exploration mission medical system design by quantitatively estimating mission medical risk. IMPACT v1.0 includes a novel evidence library baselined to exploration environments, an expanded list of 119 medical conditions, medical capabilities and resources critical for management of these medical conditions, and the ability for rapid and iterative analysis in the setting of modifiable design reference missions (DRMs). Our first analysis identified which of the 119 medical conditions XR had diagnostic or therapeutic utility for. Subject matter experts (SMEs) recorded which XR views would be performed under ideal terrestrial circumstances for diagnosis/management of each condition, as well as which views are pragmatic for spaceflight limitations. A second analysis utilized IMPACT to identify significant conditions that contribute greatest to medical risk during a notional long-duration Lunar orbit and Lunar surface DRM. Medical system risk estimates include loss of crew life (LOCL), need for return to definitive care (RTDC; medical evacuation), and an estimate of crew task time affected (TTA). Using a standardized semi-quantitative scoring methodology, a deeper evaluation of each of the most significant medical conditions was performed. Data from both of these separate analyses were used to hypothesize what ideal and pragmatic XR studies may impact clinical management of the most significant conditions predicted to lead to medical risk. RESULTS: Approximately 1/3 of the IMPACT conditions were identified as being more effectively or comprehensively assessed or treated with the addition of miniature XR technology. The resulting conditions benefitting diagnostically and therapeutically from XR are revealed, as well as the ideal and pragmatic XR views and medical procedures benefitting from XR. The conditions of clinical significance and those most contributing to risk are also displayed. Among the conditions that contribute greatest to LOCL, four conditions for which XR may improve the diagnosis and management of include: decompression sickness, traumatic shock, dental abscess, and respiratory failure. Among conditions that contributed to RTDC, the evaluation and management of wrist fracture is likely improved by XR. For conditions leading to crew TTA, evaluation and management of EVA shoulder injuries, upper and lower extremity strains, back strains, and EVA hand injuries are likely improved by XR. DISCUSSION: Miniature XR in spaceflight has the potential to improve the evaluation and management of a substantial portion of conditions that most contribute to medical risk. This presentation is an introduction to the possibilities miniature XR provides for future human spaceflight missions and subsequent presenters will expand on potential applications in more detail. LEARNING OBJECTIVES: 1) Understand the previous limitations of using radiography in the management of spaceflight medical conditions; 2) Evaluate the findings from the IMPACT tool analysis, which allows quantification of the benefit miniature XR could provide for managing high-risk medical conditions in long-duration lunar orbit and surface missions, focusing on improvements in crew health outcomes; 3) Analyze case studies where miniature XR technology could reduce the medical risks associated with spaceflight missions, specifically in diagnosing and managing conditions such as decompression sickness, traumatic shock, and EVA-related injuries.

A Anderson↗

Performance

Effect on chimpanzee performance after being subjected to decompression to near vacuum followed by recompression - aerospace medicine

CHIMPANZEE↗

Physiology

Physiological parameters recorded from chimpanzees before, during, and after rapid decompression to near vacuum - aerospace medicine

DECOMPRESSION↗

Physical environment

Instrumentation for decompression chamber and other equipment used for environmental testing of chimpanzee - aerospace medicine

INSTRUMENTATION↗

The exercise and environmental physiology of extravehicular activity

Extravehicular activity (EVA), i.e., exercise performed under unique environmental conditions, is indispensable for supporting daily living in weightlessness and for further space exploration. From 1965-1996 an average of 20 h x yr(-1) were spent performing EVA. International Space Station (ISS) assembly will require 135 h x yr(-1) of EVA, and 138 h x yr(-1) is planned for post-construction maintenance. The extravehicular mobility unit (EMU), used to protect astronauts during EVA, has a decreased pressure of 4.3 psi that could increase astronauts' risk of decompression sickness (DCS). Exercise in and repeated exposure to this hypobaria may increase the incidence of DCS, although weightlessness may attenuate this risk. Exercise thermoregulation within the EMU is poorly understood; the liquid cooling garment (LCG), worn next to the skin and designed to handle thermal stress, is manually controlled. Astronauts may become dehydrated (by up to 2.6% of body weight) during a 5-h EVA, further exacerbating the thermoregulatory challenge. The EVA is performed mainly with upper body muscles; but astronauts usually exercise at only 26-32% of their upper body maximal oxygen uptake (VO2max). For a given ground-based work task in air (as opposed to water), the submaximal VO2 is greater while VO2max and metabolic efficiency are lower during ground-based arm exercise as compared with leg exercise, and cardiovascular responses to exercise and training are also different for arms and legs. Preflight testing and training, whether conducted in air or water, must account for these differences if ground-based data are extrapolated for flight requirements. Astronauts experience deconditioning during microgravity resulting in a 10-20% loss in arm strength, a 20-30% loss in thigh strength, and decreased lower-body aerobic exercise capacity. Data from ground-based simulations of weightlessness such as bed rest induce a 6-8% decrease in upper-body strength, a 10-16% loss in thigh extensor strength, and a 15-20% decrease in lower-body aerobic exercise capacity. Changes in EVA support systems and training based on a greater understanding of the physiological aspects of exercise in the EVA environment will help to insure the health, safety, and efficiency of working astronauts.

Review↗