Universal Utility Data Exchange (UUDEX) Functional Design Requirements - Rev 1

This document provides a set of high-level functional design requirements for Universal Utility Data Exchange (UUDEX). These requirements include a set of use cases, data exchanges supported by UUDEX, both for grid operations and for cyber security data, functional requirements for data exchange, data models used by UUDEX, data exchange architectures, and security considerations. These functional design requirements are intended to be used in more detailed design documents.

97 MATHEMATICS AND COMPUTING↗

Cyber Security of DC Fast Charging: Potential Impacts to the Electric Grid

Relevance of Cyber Security for High Power EV Charging Public Safety ? High voltage & high current charging infrastructure? Potential wide spread grid impact ? Intermittent high load:? Wide range of power (up to 350+ kW)? Short duration charge events? Increasing deployment of fast chargers to meet needs of increasing EV market adoption? ? Consumer confidence in charging infrastructure? Reliability and robustness required to reduce range anxiety

99 GENERAL AND MISCELLANEOUS↗

Cryptography Considerations for Distributed Energy Resource Systems

Distributed energy resource (DER) systems are rapidly being adopted and integrated within the electric power grid. Developments in smart grid devices and communication protocols are advancing the power system domain but are also introducing new cyber attack vectors. In particular, the ability to maintain the confidentiality, integrity, and availability of data is of increasing concern. Cryptography is a powerful tool that can be leveraged to protect DER systems and their critical information. This paper discusses prominent methods of cryptographic authentication and encryption that can be used to secure DER communications. Specific considerations and recommendations for applying cryptography to DER systems are provided, including system design constraints and system impact. These will be demonstrated with two case studies that assess cryptography hardware requirements and communications latency in DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Empirical Analysis and Automated Classification of Security Bug Reports

With the ever expanding amount of sensitive data being placed into computer systems, the need for effective cybersecurity is of utmost importance. However, there is a shortage of detailed empirical studies of security vulnerabilities from which cybersecurity metrics and best practices could be determined. This thesis has two main research goals: (1) to explore the distribution and characteristics of security vulnerabilities based on the information provided in bug tracking systems and (2) to develop data analytics approaches for automatic classification of bug reports as security or non-security related. This work is based on using three NASA datasets as case studies. The empirical analysis showed that the majority of software vulnerabilities belong only to a small number of types. Addressing these types of vulnerabilities will consequently lead to cost efficient improvement of software security. Since this analysis requires labeling of each bug report in the bug tracking system, we explored using machine learning to automate the classification of each bug report as a security or non-security related (two-class classification), as well as each security related bug report as specific security type (multiclass classification). In addition to using supervised machine learning algorithms, a novel unsupervised machine learning approach is proposed. An ac- curacy of 92%, recall of 96%, precision of 92%, probability of false alarm of 4%, F-Score of 81% and G-Score of 90% were the best results achieved during two-class classification. Furthermore, an accuracy of 80%, recall of 80%, precision of 94%, and F-score of 85% were the best results achieved during multiclass classification.

Cybersecurity↗

Analysis of System and Interoperability Impact from Securing Communications for Distributed Energy Resources

As the power grid incorporates increasing amounts of distributed energy resources (DER) that provide new generation sources, new opportunities are created for improving operation of the grid while large challenges also arise for preserving grid reliability and security. To improve grid performance, DERs can be utilized to provide important support functionality, such as supporting frequency and voltage levels, especially if they are assisted by communication schemes as part of an advanced distribution management system (ADMS). Unfortunately, such connectivity and grid support functionality also creates additional cyber security risk with the potential for degradation of grid services, especially under conditions with high amounts of distributed generation. This paper will first discuss the communications needed by DERs to support system and interoperability objectives, as well as the security requirements and impact of securing these communications. Some common security mechanisms are discussed in relation to DERs, and a simulated 15-bus model of a distribution feeder is used to demonstrate aspects of the DER communications and impact to grid performance. These results help to advance understanding of the benefits, requirements, and mechanisms for securely implementing DER communications while ensuring that grid reliability is maintained.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of an Assessment Methodology That Enables the Nuclear Industry to Evaluate Adoption of Advanced Automation

Nuclear power has a crucial role in providing safe, reliable, and economical carbon-free electricity for today and the future. For continued operation, many of the existing United States nuclear power plants will begin the subsequent license renewal process for extending their operating license periods. As plants extend their expected operating lifetimes, there is a significant opportunity to modernize. These plants have a much stronger business case with these extended mission periods to modernize and significantly enhance their economic viability in current and future energy markets by implementing digital technologies that support innovation, efficiency gains, and business-model transformation. Ensuring continued safety and reliability is crucial. Transformative digital technologies—including automation—that fundamentally change the concept of operation for the nuclear power plant operating model requires a critical focus on the human and technology integration element. Further, the nuclear industry has historically been reluctant to modernize due to having a risk adverse culture and lack of clarity for a transformative new state vision (Joe & Remer, 2019; Thomas et al., 2020). Common barriers include (1) the perceived value and return on investment (ROI) of digital technology, (2) the perceived risk associated with licensing, regulatory, and cybersecurity, and (3) insufficient guidance for performing digital modifications to power generation systems. This work presents a methodology to address these barriers and support the industry in adopting advanced automation and digital technology through developing a transformative vision and implementation strategy that will address the human and technology integration element. This research leverages previous LWRS Program and industry results. It draws specifically on previous LWRS Program research in the areas of advanced alarm systems, computer-based procedures, model informed decision support, and advanced human-system interface displays (e.g., overviews and task-based). The modernization methodology can be used to guide transformative thinking when integrating a set of vendor-specific capabilities to support a new concept of operations and a utility’s end-state vision. The results of this research are organized into six major sections: - Section 1 introduces the need for supporting large-scale digital modifications that will renew the technology base for extended operating life beyond 60 years - Section 2 describes the challenges that the nuclear industry is enduring with modernizing. - Section 3 summarizes the primary standards and guidance. - Section 4 presents earlier work from the LWRS Program regarding the development of a transformative conceptual design for an advanced control room of a hybrid plants. - Section 5 presents a methodology that is designed at addressing the challenges in the industry today in achieving a transformative new state vision and concept of operations. - Conclusions and next steps of this research are provided in Section 6.

99 GENERAL AND MISCELLANEOUS↗

Chapter 5: Integration of Renewable Energy Technologies in Buildings and Cities

Sustainable Energy Technologies, such as the solar, wind, and waterpower systems described in other chapters of this book, need to be integrated into our energy systems to expand access to energy while avoiding harmful effects on the environment. The existing utility system or 'grid' is a network that consists of components for generation, transmission, distribution, and control of electric power from producers (also called 'resources') to consumers (also called 'loads' or 'demand'). Public safety necessitates that the grid be reliable, and public policy requires that grid power be affordable and broadly accessible. Much of the existing power grid was constructed before the advent of modern information technology for controls and automation. The existing grid is facing new challenges related to increases in power demand, complexity in managing more diverse and distributed resources, power quality issues introduced by 'non-linear' loads (that have parasitic inductance and capacitance like LED lights or computers), physical and cybersecurity threats, and challenges to the existing economic model of costs and revenues. Increases in power demand include not only growth in population and per-capita electricity use, but also call for electricity to meet the need for heating and transportation as well. Electric vehicles are a rapidly growing example of this electrification of previously fossil-fueled uses. [Your author's Chevrolet Volt vehicle uses about the same amount of electricity as his house, around 300 kWh/month. Fortunately, both are served with solar photovoltaics (PVs)]. Therefore, there is an immediate need for improvement toward a reliable, self-regulating, efficient, and economical grid system that will allow the integration of renewable distributed power generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Securing Distributed Energy Resource Integration

The penetration of distributed energy resources (DER) is growing at much higher rates than predicted 20 years ago. Far from being used only in residential settings, DER are now installed on distribution and transmission circuits. In this position, they do not have the same properties as traditional generators and are more flexible in many cases. The growing penetration and range of uses for DER motivate the need to reliably and safely integrate them into the grid. Operators must be able to rely on them not only for normal operation, but also during abnormal conditions like black starts or adverse cyber scenarios. To that end, we study the communications, device interfaces, and potential consequences of DER operation under abnormal and adversarial conditions. The weaknesses of communications networks are studied based on the industrial protocols used, and the benefits of security features are examined. The device interfaces are found to be vulnerable to attack based on the requirements in the IEEE-1547 standard for DER interconnection and interoperability, which is expected to be adopted in the next ten years. In addition to exploring the requirements of the standard, we show that these vulnerabilities and others do exist and can be used maliciously in a modern storage system DER. Consequences of these vulnerabilities range from exacerbated grid instability, to simultaneous loss of large portions of DER penetration, to physical damage to inverters or DER themselves and other sensitive equipment. We tie these outcomes to specific attacker actions in an effort to give operators a better threat intelligence view that allows them to prioritize mitigations. Finally, we discuss mitigations that could prevent many of the adversarial scenarios described. Some solutions can be added to existing infrastructure, while others may require longer term planning for grid modernization with consideration for security.

25 ENERGY STORAGE↗

Resilience Framework for Electric Energy Delivery Systems (R.1)

The intent of this document is to provide a Resilience Framework for electrical energy delivery systems which can be applied to Distributed Wind. However, the framework is not limited by application to any resource or system. This framework represents the defined steps to a cyclical process similar in mechanism to both cybersecurity and risk frameworks, while providing a common set of language and process for all stakeholders involved. The need for this Resilience Framework was established in a previous document, “Distributed Wind Resilience Metrics for Electric Energy Delivery Systems.” One important characteristic we see in resilience is the unique needs and perspectives of different systems, geographies, resources, stakeholders, perceived risks, and consequences, which we term the distinctiveness property. This distinctiveness property drives the requirement to have a resilience framework or methodology that can be implemented by different types of organizations and systems. The process or methodology should be cyclic. Recognizing that a system’s resilience is based on finite resources and time, it must continually evolve through this framework’s risk management and capital investment steps at an appropriate pace for its distinctiveness property.

17 WIND ENERGY↗

Analysis of Supply Chain Challenges in the U.S. Solar Industry: Focus on Build America, Buy America Act and Inverter Supply Issues

The United States (U.S.) solar industry has been undergoing significant transformation, driven largely by meeting U.S. climate goals while simultaneously maintaining national security. At the forefront of this movement is the Inflation Reduction Act (IRA) and the Build America, Buy America (BABA) Act. The IRA has driven investment in clean energy generation deployments while the BABA Act, enacted under Division G, Title IX of the Infrastructure Investment and Jobs Act (IIJA) establishes domestic content procurement preference for all federal financial assistance obligated for infrastructure projects. While these pieces of legislation aim to reduce reliance on foreign-made solar components and increase domestic production, the sector continues to face notable supply chain challenges. These are particularly pronounced with inverters, a critical component in solar photovoltaic (PV) systems. This report explores the current state of these supply chain challenges, with a specific focus on the impact of the BABA requirements and the associated complexities in inverter manufacturing and supply.

14 SOLAR ENERGY↗

Software-Defined Networking Traffic Engineering Process for Operational Technology Networks

Network design goals are often functional with little consideration for security. Growth and maintenance of critical infrastructure mission-focused networks can be ad hoc and preclude large-scale technology replacements, reconfigurations, or even patching. These restrictions are contributing factors to increased vulnerabilities. Over 90% of all attacks begin with phishing and include lateral movement (Frinke 2019). Adopting a software-defined networking (SDN) approach is an effective mitigation strategy for many existing vulnerabilities. SDNs deny-by-default approach to networking restricts an adversary’s freedom of movement without impacting an organization’s mission. SDN implementations require a process that identifies an organization’s mission-specific network communications. A well-defined traffic engineering process ensures that only known devices communicate with each other on specific ports.

Software Defined Networking, Situational Awareness↗

Requirements and Recommendations for a Physical Attack Characterization Framework

This study seeks to identify existing frameworks or develop requirements and recommendations for a new framework that can consistently characterize physical attacks, analogous to MITRE ATT&CK®. MITRE ATT&CK is widely used across government, research organizations, and the cyber security community to characterize cyber attack tactics, techniques, and procedures (TTPs) in a consistent and commonly understood manner. While physical attack taxonomies, methodologies, and other tools for evaluating physical security do exist, many are sector and/or facility-type specific—and therefore not able to provide comparable scenarios across sectors—or are more focused on security assessment instead of the characterization of attacks themselves. A MITRE ATT&CK analog for physical attacks on critical infrastructure would provide a common language and structure for analysis of physical attacks. Existing attack characterization methodologies do not robustly address cyber-physical security risks. To fully understand a facility’s security needs, it is important to understand the entire vulnerability landscape from both a physical and a cyber perspective. To underscore this need, organizations such as the Cybersecurity and Infrastructure Security Agency (CISA) are calling for a coordinated approach to cyber and physical security, which they refer to as cyber and physical security convergence. A physical attack characterization framework that could be used jointly with MITRE ATT&CK would help support a more robust analysis in support of convergence, enabling the consistent characterization of attacks that utilize both cyber and physical tactics and techniques. This could provide analysts and stakeholders with a clearer understanding of how security mitigations deployed in the physical realm impact security risks in the cyber realm, and vice versa. In this study, the project team evaluates existing physical security taxonomies and methodologies to assess whether an existing method can be used to create a “physical half” of MITRE ATT&CK. This study then provides requirements and recommendations for a framework that can leverage aspects of existing methodologies. The goal of the final framework is for it to be widely adopted and referenced, regardless of critical infrastructure sector, facility type, or facility components. This study also identifies applicable use cases for when and how a framework could be applied across the various critical infrastructure sectors for a variety of attack types or motivations. Through a literature review of existing security-focused methodologies and taxonomies, engagement with relative stakeholders, evaluation of potential physical attack framework use cases, and subsequent identification of requirements, this study identified the following key findings and recommendations: There is a need for a new physical attack characterization framework; A physical attack framework should be interoperable with the MITRE ATT&CK framework; A physical attack framework should be broadly applicable, but with detailed tactics, techniques, and procedures that encompass the entire attack path; A physical attack framework should be based on observed or feasible events; A physical attack framework should adapt features from existing methodologies, frameworks, and taxonomies; A physical attack framework should be owned, overseen, and maintained by one organization.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Commercial and Multifamily Building Tenant Energy Usage Aggregation and Privacy

In a number of cities and states, building owners are required to disclose and/or benchmark their building energy use. This requires the building owner to possess monthly whole-building energy usage information, which can be challenging for buildings in which individual tenants have their own utility meters and accounts with the utility. Some utilities and utility regulators have turned to aggregation of customer data as a way to give building owners the whole-building energy usage data while protecting customer privacy. However, no utilities or regulators appear to have conducted a concerted statistical, cybersecurity, and privacy analysis to justify the level of aggregation selected. Therefore, the Tennant Data Aggregation Task was established to help utilities address these issues and provide recommendations as well as a theoretical justification of the aggregation threshold. This study is focused on the use case of submitting data for ENERGY STAR Portfolio Manager (ESPM), but it also looks at other potential use cases for monthly energy consumption data.

data aggergation↗

CCE Phase 3: Consequence-based Targeting

While Phase 2 was a data collection effort, Phase 3 is a targeting effort. In Phase 3, organizations systematically identify the necessary steps for adversary success - all from the adversary’s perspective. A key component to this approach is identifying the critical information needs, targets, access, and actions required for the adversary to achieve the desired effect. These Critical Needs are tied to accomplishing the HCE, such as the technical requirements for the payload (Development), or the access required to deliver a payload (Deployment).

99 GENERAL AND MISCELLANEOUS↗

Trade-off Analysis of Operational Technologies to Advance Cyber Resilience through Automated and Autonomous Response to Threats

The advancement of cyber resilience requires a preliminary stage of characterizing the trade-off space of mitigation options and how these might affect the stability and determinism of an operational technology (OT). This first step will set the stage for the proper cyber-secure and cyber-resilient design and confirm the affects that can be considered and approved by the OT and the security groups. To provide a baseline for this discussion, this paper provides a consideration of the cyberphysical interactions, possible mitigation steps against certain attacks and their corresponding affects that lend to the security design planning and evaluation process. As an integral part of the proposed scheme this work introduces the concept of systemwide fuzzer, i.e., a tool that manipulates the system state in an effort to determine mitigation response sequences that minimize detriments and maximize benefit in accordance with specified operational requirements.

97 MATHEMATICS AND COMPUTING↗

Impact of Emergency Diesel Generator Reliability on Microgrids and Building-Tied Systems

Microgrids are an emerging alternative as an energy backup system for critical electric loads and have improved performance compared to the traditional architecture where a single emergency diesel generator is tied to an individual building. Both architectures are dependent on the reliability of their individual generators and a quantitative and realistic comparison of the overall system reliability of the two architectures is lacking. Using recently published work on emergency diesel generator finite reliability, a quantitative methodology is presented to compare the reliability of a microgrid architecture based on centralized emergency diesel generators to the traditional approach of generators tied to individual buildings. Three system reliability performance metrics are calculated as a function of outage duration: (1) probability to meet 100% of the critical load; (2) expected fraction of lost load; and (3) probability to meet the highest priority critical loads. It is shown that stand-alone building-tied emergency diesel generators systems, even when two emergency diesel generators are used per building, cannot provide the reliability required to sustain critical loads for a grid outage lasting multiple days. Due to their network configuration and ability to share load, diesel generator-based microgrid configurations are estimated to have = 93% probability of powering all buildings for a 2-week outage there the individual building-tied emergency diesel generator architecture has a =20% probability. Microgrids do present other susceptibilities that are site specific and should be considered including vulnerabilities associated with the on-campus distribution system and cybersecurity.

backup power↗

NASA Aeronautics Research Mission Directorate System Security Engineering Approaches

System security engineering (SSE) is a set of formal engineering methods and is considered a subset of systems engineering. It is a relatively new development in systems engineering with the initial NIST (National Institute of Standards) standard published in November of 2016 with updates in 2018, and 2022. The guiding principles in our methodology are based in NIST Special Publication 800-160 Vol. 1 “Systems Security Engineering: Considerations For A Multidisciplinary Approach In The Engineering Of Trustworthy Secure Systems” and integrate methodologies from common IT (Information Technology) threat modeling approaches utilizing MBSE (Model-Based Systems Engineering). The presentation will discuss how our teams utilize SSE and MBSE (Model-Based Systems Engineering) to develop secure architectures for systems under development in our NASA aeronautics research environment. This includes the activities to develop Protection Needs (PN) that, in turn result in security requirements in the design context and policies for the future state operational context for system protection. The process of applying SSE to analyze project architectures and ConOps (Concept of Operations) is intended to ensure the transferred research is both secure and securable in a “real-world” setting.

Systems Security Engineering↗

Adaptive Control Algorithm to Adjust Settings in Photovoltaic Inverters for Electric Grid Cybersecurity (DERAC) v0.1

Volt-VAR and Volt-Watt functionality in photovoltaic (PV) smart inverters provide mechanisms to ensure system voltage magnitudes and power factors remain within acceptable limits. However, these control functions can become unstable, introducing oscillations in system voltages when not appropriately configured or maliciously altered during a cyberattack. In the event that Volt-VAR and Volt-Watt control functions in a portion of PV smart inverters in a distribution grid are unstable, the proposed adaptation scheme utilizes the remaining and stably-behaving PV smart inverters and other Distributed Energy Resources to mitigate the effect of the instability in real-time. The adaptation mechanism is entirely decentralized, model-free, communication-free, and requires virtually no external configuration. This repository provides code to simulate the algorithm in experiments on the IEEE 37 node test feeder.