Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CsY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Numerical analysis of modified Central Solenoid insert design

The United States ITER Project Office (USIPO) is responsible for fabrication of the Central Solenoid (CS) for ITER project. The ITER machine is currently under construction by seven parties in Cadarache, France. The CS Insert (CSI) project should provide a verification of the conductor performance in relevant conditions of temperature, field, currents and mechanical strain. The US IPO designed the CSI that will be tested at the Central Solenoid Model Coil (CSMC) Test Facility at JAEA, Naka. To validate the modified design we performed three-dimensional numerical simulations using coupled solver for simultaneous structural, thermal and electromagnetic analysis. Thermal and electromagnetic simulations supported structural calculations providing necessary loads and strains. According to current analysis design of the modified coil satisfies ITER magnet structural design criteria for the following conditions: (1) room temperature, no current, (2) temperature 4K, no current, (3) temperature 4K, current 60 kA direct charge, and (4) temperature 4K, current 60 kA reverse charge. Fatigue life assessment analysis is performed for the alternating conditions of: temperature 4K, no current, and temperature 4K, current 45 kA direct charge. Results of fatigue analysis show that parts of the coil assembly can be qualified for up to 1 million cycles. Distributions of the Current Sharing Temperature (TCS) in the superconductor were obtained from numerical results using parameterization of the critical surface in the form similar to that proposed for ITER. Lastly, special ADPL scripts were developed for ANSYS allowing one-dimensional representation of TCS along the cable, as well as three-dimensional fields of TCS in superconductor material. Published by Elsevier B.V.

42 ENGINEERING↗

Craniospinal Irradiation Techniques: A Dosimetric Comparison of Proton Beams With Standard and Advanced Photon Radiotherapy

Purpose: To evaluate the dosimetric benefits of advanced radiotherapy techniques for craniospinal irradiation in cancer in children. Methods and Materials: Craniospinal irradiation (CSI) using three-dimensional conformal radiotherapy (3D-CRT), tomotherapy (TOMO), and proton beam treatment (PBT) in the scattering mode was planned for each of 10 patients at our institution. Dosimetric benefits and organ-specific radiation-induced cancer risks were based on comparisons of dose-volume histograms (DVHs) and on the application of organ equivalent doses (OEDs), respectively. Results: When we analyzed the organ-at-risk volumes that received 30%, 60%, and 90% of the prescribed dose (PD), we found that PBT was superior to TOMO and 3D-CRT. On average, the doses delivered by PBT to the esophagus, stomach, liver, lung, pancreas, and kidney were 19.4 Gy, 0.6 Gy, 0.3 Gy, 2.5 Gy, 0.2 Gy, and 2.2 Gy for the PD of 36 Gy, respectively, which were significantly lower than the doses delivered by TOMO (22.9 Gy, 4.5 Gy, 6.1 Gy, 4.0 Gy, 13.3 Gy, and 4.9 Gy, respectively) and 3D-CRT (34.6 Gy, 3.6 Gy, 8.0 Gy, 4.6 Gy, 22.9 Gy, and 4.3 Gy, respectively). Although the average doses delivered by PBT to the chest and abdomen were significantly lower than those of 3D-CRT or TOMO, these differences were reduced in the head-and-neck region. OED calculations showed that the risk of secondary cancers in organs such as the stomach, lungs, thyroid, and pancreas was much higher when 3D-CRT or TOMO was used than when PBT was used. Conclusions: Compared with photon techniques, PBT showed improvements in most dosimetric parameters for CSI patients, with lower OEDs to organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of chemical and physical heterogeneities on colloid-facilitated cesium transport

A set of column experiments was conducted to investigate the chemical and physical heterogeneity effect on colloid facilitated transport under slow pore velocity conditions. Pore velocities were kept below 100 cm d-1 for all experiments. Glass beads were packed into columns establishing four different conditions: 1) homogeneous, 2) mixed physical heterogeneity, 3) sequentially layered physical heterogeneity, and 4) chemical heterogeneity. The homogeneous column was packed with glass beads (diameter 500-600 µm), and physical heterogeneities were created by sequential layering or mixing two sizes of glass bead (500-600 µm and 300-400 µm). A chemical heterogeneity was created using 25% of the glass beads coated with hydrophobic molecules (1H-1H-2H-2H-perfluorooctyltrichlorosilane) mixed with 75% pristine glass beads (all 500-600 µm). Input solution with 0.5 mM CsI and 50 mg L-1 colloids (1-µm diameter SiO2) was pulsed into columns under saturated conditions. The physical heterogeneity in the packed glass beads retarded the transport of colloids compared to homogeneous (R = 25.0), but showed only slight differences between sequentially layered (R = 60.7) and mixed heterogeneity(R = 62.4). The column with the chemical, hydrophobic/hydrophilic, heterogeneity removed most of the colloids from the input solution. All column conditions stripped Cs from colloids onto the column matrix of packed glass beads.

Colloid-facilitated transport, cesium, physical he↗

Molten salt flux synthesis and crystal structure of a new open-framework uranyl phosphate Cs{sub 3}(UO{sub 2}){sub 2}(PO{sub 4})O{sub 2}: Spectroscopic characterization and cationic mobility studies

The reaction of triuranyl diphosphate tetrahydrate precursor (UO{sub 2}){sub 3}(PO{sub 4}){sub 2}(H{sub 2}O){sub 4} with a CsI flux at 750 °C yields a yellow single crystals of new compound Cs{sub 3}(UO{sub 2}){sub 2}(PO{sub 4})O{sub 2}. The crystal structure (monoclinic, space group C2/c, a=13.6261 (13) Å, b=8.1081(8) Å, c=12.3983(12) Å, β=114.61(12)°, V=1245.41(20) Å{sup 3} with Z=4) has been solved using direct methods and Fourier difference techniques. A full-matrix least-squares refinement on the basis of F{sup 2} yielded R1=0.028 and wR2=0.071 for 79 parameters and 1352 independent reflections with I≥2σ(I) collected on a BRUKER AXS diffractometer with MoKα radiation and a charge-coupled device detector. The crystal structure is built by two independent uranium atoms in square bipyramidal coordination, connected by two opposite corners to form infinite chains {sup 1}{sub ∞}[UO{sub 5}] and by one phosphorus atom in a tetrahedral environment PO{sub 4}. The two last entities {sup 1}{sub ∞}[UO{sub 5}] and PO{sub 4} are linked by sharing corners to form a three-dimensional structure presenting different types of channels occupied by Cs{sup +} alkaline cations. Their mobility within the tunnels were studied between 280 and 800 °C and compared with other tunneled uranyl minerals. The infrared spectrum shows a good agreement with the values inferred from the single crystal structure analysis of uranyl phosphate compound. - Graphical abstract: Arrhenius plot of the electrical conductivity of tunneled compounds Cs{sub 3}U{sub 2}PO{sub 10} and CsU{sub 2}Nb{sub 2}O{sub 11.5}. Highlights: ► The reaction of (UO{sub 2}){sub 3}(PO{sub 4}){sub 2}(H{sub 2}O){sub 4} in excess of molten CsI leads to single-crystals of new tunneled compound Cs{sub 3}(UO{sub 2}){sub 2}(PO{sub 4})O{sub 2}. ► Ionic conductivity measurements and crystal structure analysis indicate a strong connection of the Cs{sup +} cations to the tunnels. ► A low symmetry in Cs{sub 3}(UO{sub 2}){sub 2}(PO{sub 4})O{sub 2} is the cause of IR activation and splitting of the bands in the IR spectrum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conventional Craniospinal Irradiation with Patient Supine and Source-Skin Distance (SSD) 100 cm for Spinal Field

We describe a method of craniospinal irradiation (CSI) in the supine position and at a source-skin distance (SSD) of 100 cm for the spinal fields. The procedure is carried out with a 100-cm isocenter linear accelerator and conventional simulator, and the treatment is delivered with 2 opposed lateral cranial fields at source-axis distance (SAD) of 100 cm and 1 or 2 direct posterior spinal fields at SSD, 100 cm. The half beam-blocked cranial fields with a collimator rotation is used to match the superior border of the spinal field at the level of C2 vertebral body. The length of the spinal field is fixed, and is the same if 2 spinal fields are used. The position of the isocenter of the spine field is defined by longitudinally moving the couch a distance from the isocenter of the cranial fields and adjusting the SSD = 100 cm to the surface of the couch with the gantry rotated to the angle of 180 Degree-Sign (posteroanterior position), and the distance can be calculated easily according to a few parameters. It only needs a simple calculation without couch rotation, extended SSD, or markers. The inferior and superior borders of the spinal field do not require visualization under fluoroscopy when it is beyond the visual field of the simulator. The entire simulation takes no more than 20 minutes. Supine craniospinal treatment using this technique may substitute the traditional prone position as a potentially beneficial alternative to CSI.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improved lithium iodide neutron scintillator with Eu 2+ activation: The elimination of Suzuki-Phase precipitates

Monovalent alkali halides such as NaI, CsI, and LiI are widely used as inorganic scintillators for radiation detection due to their light yield, the capability for the growth of large single crystals, relatively low cost, and other favorable characteristics. These materials are frequently activated through the addition of small amounts (e.g., a few hundred ppm) of elements such as thallium - or sodium in the case of CsI. The monovalent alkali halide scintillators can also be activated with low concentrations of Eu 2+ , however Eu activation has previously not been widely employed due to the non-uniform segregation of the divalent Eu dopant that leads to the formation of unwanted phases during Bridgman or other solidification crystal-growth methods. Specifically, for Eu concentrations near and above ~0.5%, Suzuki Phase precipitates form in the course of the melt-growth process, and these Suzuki Phase particles scatter the scintillation light. This adversely affects the scintillator performance via reduction in the optical transmission of the material, and depending on the crystal thickness and precipitated-particle concentration, this reduction can occur up to the point of opacity. Here we describe a post-growth process for the removal of Suzuki Phase precipitates from single crystals of the neutron scintillator LiI activated with Eu 2+ at concentrations up to and in excess of 3 wt.%, and we correlate the resulting neutron-detection performance with the thermal processing methods used to remove the Suzuki Phase particles. Furthermore, the resulting improved scintillator properties using increased Eu activator levels are applicable to neutron imaging and active interrogation systems, and pulse-height gamma-ray spectroscopy rather than pulse-shape discrimination can be used to discriminate between gamma ray and neutron interaction events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoelectron Imaging and Spectroscopy of MI 2 - (M = Cs, Cu, Au): Evolution from Ionic to Covalent Bonding

We report a combined experimental and theoretical investigation on MI 2 - (M = Cs, Cu, Ag, Au) to explore the chemical bonding in the group IA and IB di-iodide complexes. Both photoelectron imaging and low-temperature photoelectron spectroscopy are applied to MI 2 - (M = Cs, Cu, Au), yielding vibrationally resolved spectra for CuI 2 - and AuI 2 - and accurate electron affinities, 4.52 ± 0.02, 4.256 ± 0.010, and 4.226 ± 0.010 eV for CsI 2 , CuI 2 , and AuI 2 , respectively. Spin-orbit coupling is found to be important in all the di-iodide complexes and ab initio calculations including spin-orbit effects allow quantitative assignments of the observed photoelectron spectra. A variety of chemical bonding analyses (charge population, bond order, and electron localization functions) have been carried out, revealing a gradual transition from the expected ionic behavior in CsI 2 - to strong covalent bonding in AuI 2 - . Both relativistic effects and electron correlation are shown to enhance the covalency in the gold di-iodide complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The GLAST Large Area Telescope Detector Performance Monitoring

The Large Area Telescope (LAT) is one of two instruments on board the Gamma-ray Large Area Telescope (GLAST), the next generation high energy gamma-ray space telescope. The LAT contains sixteen identical towers in a four-by-four grid. Each tower contains a silicon-strip tracker and a CsI calorimeter that together will give the incident direction and energy of the pair-converting photon in the energy range 20 MeV - 300 GeV. In addition, the instrument is covered by a finely segmented Anti-Coincidence Detector (ACD) to reject charged particle background. Altogether, the LAT contains more than 864k channels in the trackers, 1536 CsI crystals and 97 ACD plastic scintillator tiles and ribbons. Here we detail some of the strategies and methods for how we are planning to monitor the instrument performance on orbit. It builds on the extensive experience gained from Integration & Test and Commissioning of the instrument on ground.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of a simple annular electron beam source and its operating characteristics in single and repetitive shot modes

In this work, design and performance of an annular carbon fiber cathode are presented. Measurements on this cathode were performed in a single high-voltage pulse generator (600 kV, 50 ns, and 50 {omega}) and a repetitive one (350 kV, <10 ns, 180 {omega}, and 100 Hz), respectively. In a single pulse regime, emphasis was placed on the uniformity of electron beam extracted from this cathode. It was found that this cathode could deliver uniform electron beams with current densities exceeding kA/cm{sup 2}. Cesium iodide (CsI) coating eliminated hot spots on the cathode surface, significantly improving the uniformity of electron emission. Under repetitively pulsed operation, this cathode exhibited a good shot-to-shot reproducibility at the pressure of 1.5x10{sup -4} Torr, suggesting an ability of surviving even in poor vacuum. However, once the base pressure rose up to 3.76x10{sup -4} Torr, the cathode performance gradually degraded as the pulse shot proceeded. Besides, some possible explanations for these experimental results are presented. These results show that given proper diode design, carbon fiber with CsI coating has great promise as electron emitter producing high-current electron beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from KIMS

KIMS is a dark matter search experiment using low background CsI(TB) crystals at Yangyang Underground Laboratory in Korea. With a total exposure of 3409 kg{center_dot}d data, we set a new limit on WIMP-nucleon cross section. We achieved the most stringent limit on the spin-dependent interaction for a pure proton case. We were able to exclude the DAMA signal region for both spin-dependent and spin-independent interaction for the WIMP mass greater than 20 GeV/c{sup 2}. KIMS experiment is upgraded with 12 CsI(TB) crystals corresponding to a total mass of 104 kg and accumulating data since Jan. 2008.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The PHENIX Hadron Blind Detector

Dielectron measurements by the PHENIX Experiment at RHIC are limited by the combinatorial background from electrons and positrons which are not produced in the same pair. The Hadron Blind Detector will allow a substantial reduction of this background by correctly identifying dielectrons from photon conversions and pion Dalitz decays which dominate the signal in the low mass region of the spectrum. Triple GEM stacks, with a CsI photocathode deposited on the uppermost GEM, detect Cherenkov light produced by electrons in a CF{sub 4} radiator. The transparency of CF{sub 4}, high quantum efficiency of CsI in the UV, and absence of a window between the gas radiator and the GEMs allow a large photoelectron yield, while minimizing the hadron signal. Results from the HBD in RHIC's Run-7 and preparations for upcoming runs are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computer Simulation of the Light Yield Nonlinearity of Inorganic Scintillators

To probe the nature of the physical processes responsible for the nonlinear photon response of inorganic scintillators, we have combined a Monte Carlo (MC) code for calculating the microscopic spatial distributions of electron-hole pairs with a kinetic Monte Carlo (KMC) model of energy-transfer processes. In this publication, we focus on evaluating the contribution of an annihilation mechanism between self-trapped excitons (STE) to the photon response of pure CsI and Ce-doped LaBr3. A KMC model of scintillation mechanisms in pure CsI was developed previously and we introduce in this publication a similar model for Ce-doped LaBr3. We show that the KMC scintillation model is able to reproduce both the kinetics and efficiency of the scintillation process in Ce-doped LaBr3. Relative light output curves were generated at several temperatures for both scintillators from simulations carried out at 2, 5, 10, 20, 100, and 400 keV. These simulations suggest that STE-STE annihilation can account for the initial rise in relative light yield with increasing incident energy. This is due to the fact that the proportion of high-density regions decreases as the incident energy increases thus reducing the likelihood for STE-STE encounter. In addition, the simulations clearly show a lack of temperature dependence of the relative light output, in agreement with a majority of experimental work on the temperature dependence of nonlinearity in inorganic scintillators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillating screens sensitivity and resolution studies for low energy, low intensity beam diagnostics

In order to investigate the limits of scintillating screens for beam profile monitoring in the ultra-low energy, ultra-low intensity regime, CsI:Tl, YAG:Ce, and a Tb glass-based scintillating fiber optic plate (SFOP) were tested. The screens response to 200 and 50 keV proton beams with intensities ranging from a few picoampere down to the subfemtoampere region was examined. In the following paper, the sensitivity and resolution studies are presented in detail for CsI:Tl and the SFOP, the two most sensitive screens. In addition, a possible use of scintillators for ultra-low energy antiproton beam monitoring is discussed.

43 PARTICLE ACCELERATORS↗

A Very High Momentum Particle Identification Detector for the ALICE experiment

The main purpose of the ALICE experiment at CERN is to identify and study the quark-gluon plasma (QGP) in heavy ion collisions at the LHC. Among others, hadrochemistry allows for a detailed insight into the characteristics of the high temperature and density system created in these events. It is therefore important to be able to identify charged particles on a track by track basis. Moreover, results from high energy nucleus-nucleus collisions obtained by other experiments (e.g. at RHIC) indicate that it is imperative to extend the detection capability of ALICE to higher momenta. To meet these challenges, we propose the construction of the Very High Momentum Particle Identification Detector (VHMPID), which aims to identify charged pions, kaons, protons and antiprotons in the momentum range of 10 GeV/c<p{sub T}<30 GeV/c. In this contribution we will review the relevant physics arguments in proton-proton and heavy ion collisions as well as the detector proposal based on a RICH (Ring Imaging Cherenkov) detector with a C{sub 4}F{sub 10} radiator and a MWPC based CsI photon counter. In addition, we will present the advances in the development of an alternative multi-THGEM based CsI photon detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo Simulation of Gamma-Ray Response of BaF2 and CaF2

We have employed a Monte Carlo (MC) method to study intrinsic properties of two alkaline-earth halides, namely BaF2 and CaF2, relevant to their use as radiation detector materials. The MC method follows the fate of individual electron-hole (e-h) pairs and thus allows for a detailed description of the microscopic structure of ionization tracks created by incident γ-ray radiation. The properties of interest include the mean energy required to create an e-h pair, W, Fano factor, F, the maximum theoretical light yield, and the spatial distribution of e-h pairs resulting from γ-ray excitation. Although W and F vary with incident photon energy at low energies, they tend to constant values at energies higher than 1 keV. W is determined to be 18.9 and 19.8 eV for BaF2 and CaF2, respectively, in agreement with published data. The e-h pair spatial distributions exhibit a linear distribution along the fast electron tracks with high e-h pair densities at the end of the tracks. Most e-h pairs are created by interband transition and plasmon excitation in both scintillators, but the e-h pairs along fast electron tracks in BaF2 are slightly clustered, forming nanoscale domains and resulting in the higher e-h pair densities than in CaF2. Combining the maximum theoretical light yields calculated for BaF2 and CaF2 with those obtained for CsI and NaI shows that the theoretical light yield decreases linearly with increasing band gap energy.

detector materials↗

Enhanced quantum efficiency from hybrid cesium halide/copper photocathodes

The quantum efficiency (QE) of Cu is found to increase dramatically when coated by a CsI film and then irradiated by a UV laser. Over three orders of magnitude quantum efficiency enhancement at 266 nm is observed in CsI/Cu(100), indicating potential application in future photocathode devices. Upon laser irradiation, a large work function reduction to a value less than 2 eV is also observed, significantly greater than for similarly treated CsBr/Cu(100). The initial QE enhancement, prior to laser irradiation, is attributed to interface interaction and the intrinsic properties of the Cs halide film. Further QE enhancement following activation is attributed to formation of inter-band states and Cs metal accumulation at the interface induced by laser irradiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗