Fatigue Crack Growth Rate of Inconel 718 Sheet at Cryogenic Temperatures

Inconel 718 sheet material was tested to determine fatigue crack growth rate (FCGR) at cryogenic conditions representative of a liquid hydrogen (LH2) environment at -423 degree F. Tests utilized M(T) and ESE(T) specimen geometries and environments were either cold gaseous helium or submersion in LH2. The test results support a significant improvement in the fatigue crack growth threshold at -423 degree F compared to -320 degree F or 70 degree F.

Wells, Douglas↗

Mechanical Tensile Testing of 3D-Printed Titanium 6Al-4V at Cryogenic Temperature Presentation

- Titanium 6Al-4V is a highly desired material for use in space cryogenics applications. - Structural applications with good strength-to-weight ratios - Thermal isolation applications - Titanium 6Al-4V components can be fabricated via 3D-Printing which can be very beneficial to cryogenic spaceflight components: - 3D-Printing allows parts to be made with geometries and features that are very difficult and sometimes impossible via traditional methods. - Mass savings of components - Increasing structural integrity of components - Increasing thermal isolation and/or conduction of components - Cost savings - Schedule savings

Bryan L James↗

Connectors and Wiring for Cryogenic Temperatures

Tests performed at Langley Research Center to find connectors, cables, and other electrical components suitable for use in cryogenic environment described. In addition, several electrical cables have to flex under cryogenic conditions. Tests necessary to qualify materials for use in National Transonic Facility (NTF), which operates at temperature range from 175 degrees to - 300 degrees F (353 to 89 K).

Turner, R. D.↗

Adhesive for cryogenic temperature applications

Adhesive, which bonds a metal liner to a filament wound composite structure used for cryogenic pressure vessels, prevents the metal liner from buckling under depressurization. The adhesive consists of adducts of urethane and epoxy resins.

Doyle, H. M.↗

FET's Perform Well At Cryogenic Temperatures

New metal-oxide-semiconductor field-effect transistors designed for source-follower preamplifiers operating at liquid-helium temperatures in conjunction with infrared detectors. Lower thresholds and offset give CryoFET's greater dynamic range and linearity than conventional MOSFET's at low temperatures and facilitates pair balancing to reduce offsets in output. Reduces heat loading of cryogenic system, extending life, reliability, and performance of cryogenic infrared instruments.

Sclar, N.↗

A review of film boiling at cryogenic temperatures.

Film boiling occurs in the quenching of metals, the chilling of biological species, the regenerative cooling of rockets, and the cooling down of a cryogenic fuel tank. Occasionally film boiling is also found in a nuclear reactor or in a cryomagnet. Aspects of film boiling involving an unconstrained liquid mass are considered, giving attention to the evaporation time, the Leidenfrost temperature, solid-liquid contacts, the thermal properties of the solid, effects of coating or scale, wettability, the metastable condition, and the velocity effect on drops. Developments discussed with regard to pool boiling are related to vertical surfaces, film boiling from horizontal surfaces, film boiling from a horizontal cylinder, film boiling from a sphere, and film boiling of helium. Processes of film boiling in a channel are also analyzed.

Hsu, Y. Y.↗

Tunable Permanent Magnet Quadrupole Operating at Cryogenic Temperatures for Accelerators

The project objective is to develop a compact and tunable quadrupole using Electron Energy Corporation (EEC)’s PM materials for cryogenic accelerator applications. To achieve this objective, EEC and SLAC National Accelerator Laboratory (SLAC) will collaborate to develop a cost-effective quadrupole and optimize the conventional manufacturing process. Based on previous experience, EEC designed an innovative field adjustment capability using tuning magnets which is able to achieve all the requirements for SLAC’s cold copper collider (C3 ) application. These novel ideas enable us to develop a compact and tunable quadrupole magnet superior to the current designs. Our approach is to leverage EEC's over 50 years of experience in magnet manufacturing and SLAC’s beamline test capabilities.

42 ENGINEERING↗

Development of an electronically-scanned pressure module for operation at cryogenic temperatures

Pressure and temperature characteristics were measured for a number of multichannel electronically scanned pressure sensors. The tests were made on commercially available units designed to operate in a controlled temperature environment. Measurements of zero shift, sensitivity, and nonlinearity for each transducer were taken over a temperature range from 100 K to 340 K using a computer controlled data acquisition system. The units tested failed to meet accuracy specifications over the complete temperature range, which was expected. However, the sensors showed acceptable and predictable behavior over the temperature range from approximately -40 C (233 K) to 70 C (343 K). It was determined that a combination of local heating and accurate temperature monitoring can result in a device that can be compensated for temperature as well as its other physical properties. The design of a prototype for operation in a cryogenic environment is proposed, and a method for compensation is developed.

Johnson, Preston B.↗

Cryogenic temperature control by means of energy storage materials

An investigation was conducted to study the concept of thermal control by means of physical or chemical reaction heats for applications involving the storage of cryogens during long-term space voyages. The investigation included some preliminary experimental tests of energy storage material (ESM) effectiveness. The materials considered can store and liberate large amounts of thermal energy by means of mechanisms such as sensible heat, heat of fusion, and physical or chemical reaction heat. A differential thermal analysis was utilized in the laboratory tests. Attention is given to the evaluation of cryogenic ESM thermal control concepts, the experimental determination of phase change materials characteristics, and adsorption ESMs. It is found that an ESM shield surrounded by multiple layer insulation provides the best protection for a cryogen store.

Grodzka, P. G.↗

Passive Gas-Gap Heat Switches for Use in Low-Temperature Cryogenic Systems

We present the current state of development in passive gas-gap heat switches. This type of switch does not require a separate heater to activate heat transfer but, instead, relies upon the warming of one end due to an intrinsic step in a thermodynamic cycle to raise a getter above a threshold temperature. Above this temperature sequestered gas is released to couple both sides of the switch. This enhances the thermodynamic efficiency of the system and reduces the complexity of the control system. Various gas mixtures and getter configurations will be presented.

Gas-gap↗

Thermal Conductivity of Electroplated Copper Onto Bulk Niobium at Cryogenic Temperatures

Superconducting radio-frequency (SRF) cavities made of high-purity bulk niobium are widely used in modern particle accelerators. The development of metallic outer coatings with high thermal conductivity would have a beneficial impact in terms of improved thermal stability, reduced material cost and for the development of conduction-cooled, cryogen-free SRF cavities. Several high-purity, fine-grain Nb samples have been coated with 2-4 mm thick copper by electroplating. Measurements of the thermal conductivity of the bimetallic Nb/Cu samples in the range 2 ? 7 K showed values of the order of 1 kW/(m K) at 4.3 K. Very good adhesion between copper and niobium was achieved by depositing a thin Cu layer by cold spray on the niobium, prior to electroplating the bulk Cu layer.

Dhakal, P.↗