Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cryogenic pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Reciprocating Linear Electric Motor

Features include structural simplicity and good force/displacement characteristics. Reciprocating motor has simple, rugged construction, relatively low reciprocating weight, improved power delivery, and improved force control. Wear reduced by use of magnetic bearings. Intended to provide drivers for long-lived Stirling-cycle cryogenic refrigerators, concept has less exotic applications, such as fuel pumps.

Goldowsky, M. P.↗

Fully Solid State Thermomagnetoelectric Generator: Cycle Model and Proof-of-Concept Results

Electricity generation from heat in small-scale systems is currently limited to internal and external combustion heat engine generators or thermoelectric elements. This study introduces a new concept for a solid state thermomagnetoelectric power generator and presents a theoretical study of the cycle. While magnetocaloric materials (MCMs) are common in cryogenic cooling applications, in this work the magnetocaloric thermodynamic heat pump cycle is reversed to generate electricity from low-grade heat. A critical distinguishing feature of the approach is that there are no moving parts: the system directly converts heat into electricity with no moving magnet or regenerators (similar to thermoelectric elements). By periodic heating and cooling of the MCM, the magnetic field inside the copper coil changes in time, generating alternating current electricity. This fully solid state system can directly convert heat into electricity and is modeled at 54% of Carnot efficiency. Compared with state-of-the-art thermoelectric elements, the proposed technology has 3-4 times higher heat-to-electricity conversion efficiency at the same driving temperature difference.

Zhang, Mingkan↗

Experimental results and numerical modeling of a high-performance large-scale cryopump. I. Test particle Monte Carlo simulation

For the torus of the nuclear fusion project ITER (originally the International Thermonuclear Experimental Reactor, but also Latin: the way), eight high-performance large-scale customized cryopumps must be designed and manufactured to accommodate the very high pumping speeds and throughputs of the fusion exhaust gas needed to maintain the plasma under stable vacuum conditions and comply with other criteria which cannot be met by standard commercial vacuum pumps. Under an earlier research and development program, a model pump of reduced scale based on active cryosorption on charcoal-coated panels at 4.5 K was manufactured and tested systematically. The present article focuses on the simulation of the true three-dimensional complex geometry of the model pump by the newly developed ProVac3D Monte Carlo code. It is shown for gas throughputs of up to 1000 sccm ({approx}1.69 Pa m{sup 3}/s at T = 0 deg. C) in the free molecular regime that the numerical simulation results are in good agreement with the pumping speeds measured. Meanwhile, the capture coefficient associated with the virtual region around the cryogenic panels and shields which holds for higher throughputs is calculated using this generic approach. This means that the test particle Monte Carlo simulations in free molecular flow can be used not only for the optimization of the pumping system but also for the supply of the input parameters necessary for the future direct simulation Monte Carlo in the full flow regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Superfluid helium cryogenic systems for superconducting RF cavities at KEK

Recent accelerator projects at KEK, such as the Superconducting RF Test Facility (STF) for R and D of the International Linear Collider (ILC) project and the compact Energy Recovery Linac (cERL), employ superconducting RF cavities made of pure niobium, which can generate high gradient acceleration field. Since the operation temperature of these cavities is selected to be 2 K, we have developed two 2 K superfluid helium cryogenic systems for stable operation of superconducting RF cavities for each of STF and cERL. These two 2 K superfluid helium cryogenic systems are identical in principle. Since the operation mode of the cavities is different for STF and cERL, i.e. the pulse mode for STF and the continuous wave mode for cERL, the heat loads from the cavities are quite different. The 2 K superfluid helium cryogenic systems mainly consists of ordinary helium liquefiers/refrigerators, 2 K refrigerator cold boxes, helium gas pumping systems and high-performance transfer lines. The 2 K refrigerators and the high-performance transfer lines are designed by KEK. Some superconducting RF cavity cryomodules have been already connected to the 2 K superfluid helium cryogenic systems for STF and cERL respectively, and cooled down to 2 K successfully.

43 PARTICLE ACCELERATORS↗

The fill density of automotive cryo-compressed hydrogen vessels

Cryo-compressed hydrogen storage promises to deliver highest system storage density leading to fundamental cost and safety advantages. Yet, cryogenic vessels are complex systems, continuously drifting in thermodynamic space depending on use patterns, insulation performance, vessel characteristics, liquid hydrogen pump performance, and para-H 2 to ortho-H 2 conversion. This paper reflects a comprehensive evaluation of all factors affecting cryogenic vessel fill density, in an effort to evaluate system performance vs. operational parameters over a broad range of conditions. The results validate previous experiments and models indicating that cryogenic vessels have maximum fill density of all available storage technologies, and fill density is most sensitive to daily driving distance and insulation performance. It is lastly predicted that para-H 2 to ortho-H 2 conversion will affect most automobiles, increasing fill density by up to 5.3%. In a future world dominated by cryogenic H 2 fueled vehicles, para-H 2 to ortho-H 2 conversion inside the vessel will be the closest contact an average person will have with quantum mechanics outside of consumer electronics.

08 HYDROGEN↗

Diffusion, thermalization, and optical pumping of YbF molecules in a cold buffer-gas cell

We produce YbF molecules with a density of 10{sup 18} m{sup -3} using laser ablation inside a cryogenically cooled cell filled with a helium buffer gas. Using absorption imaging and absorption spectroscopy we study the formation, diffusion, thermalization, and optical pumping of the molecules. The absorption images show an initial rapid expansion of molecules away from the ablation target followed by a much slower diffusion to the cell walls. We study how the time constant for diffusion depends on the helium density and temperature and obtain values for the YbF-He diffusion cross section at two different temperatures. We measure the translational and rotational temperatures of the molecules as a function of time since formation, obtain the characteristic time constant for the molecules to thermalize with the cell walls, and elucidate the process responsible for limiting this thermalization rate. Finally, we make a detailed study of how the absorption of the probe laser saturates as its intensity increases, showing that the saturation intensity is proportional to the helium density. We use this to estimate collision rates and the density of molecules in the cell.

74 ATOMIC AND MOLECULAR PHYSICS↗

THESEUS: A techno-economic design, integration and downselection framework for energy storage

Optimal selection of energy storage technologies is critical to ensure reliable integration of intermittent and often uncertain renewable energy in electricity grids. The consideration of a diverse set of energy storage technologies is required for a more sustainable deployment of energy storage. We present THESEUS (TecHno-Economic framework for Systematic Energy storage Utilization and downSelection), which is a comprehensive framework for the optimal selection, design and operation of energy storage systems. THESEUS includes rigorous models of major energy storage technologies at different maturity levels, such as thermal storage using phase-change materials or molten salt, cryogenic storage, mechanical storage in the form of compressed air and pumped hydro storage, chemical storage using hydrogen, and electrochemical storage in the form of lithium-ion, sodium sulfur and vanadium flow batteries. An illustrative case study on state-wide prospective energy storage shows that storage integration with fossil power plants could reduce the cost of meeting the grid energy demand by 20%, with mechanical storage as the best suited technology. Although high-temperature thermal storage has low storage efficiency, it is optimal for integration with renewable energy plants. In addition, Li-ion batteries are optimal for high ramping but low storage duration requirements. Furthermore, such insights can enable the deployment of both existing and emerging energy storage technologies to facilitate a smooth transition to a clean energy future.

25 ENERGY STORAGE↗

Front-end system for Yb : YAG cryogenic disk laser

A new front-end system for a cryogenic Yb : YAG laser is designed. The system consists of a femtosecond source, a stretcher and a regenerative amplifier with an output energy of 25 μJ at a pulse repetition rate of 49 kHz, a pulse duration of ∼2 ns and a bandwidth of ∼1.5 nm. After increasing the pump power of the regenerative amplifier, it is expected to achieve a pulse energy of ∼1 mJ at the input to cryogenic amplification stages, which will allow one to obtain laser pulses with a duration of several picoseconds at the output of the cryogenic laser after compression. (extreme light fields and their applications)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radial quasiballistic transport in time-domain thermoreflectance studied using Monte Carlo simulations

Recently, a pump beam size dependence of thermal conductivity was observed in Si at cryogenic temperatures using time-domain thermal reflectance (TDTR). These observations were attributed to quasiballistic phonon transport, but the interpretation of the measurements has been semi-empirical. Here, we present a numerical study of the heat conduction that occurs in the full 3D geometry of a TDTR experiment, including an interface, using the Boltzmann transport equation. We identify the radial suppression function that describes the suppression in heat flux, compared to Fourier's law, that occurs due to quasiballistic transport and demonstrate good agreement with experimental data. We also discuss unresolved discrepancies that are important topics for future study.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-Node Modeling of Cryogenic Tank Pressurization System Using Generalized Fluid System Simulation Program

Cryogenic Tanks are pressurized by inert gas such as Helium or Nitrogen to maintain the required pressure of the propellant delivered to the turbo-pump of a liquid rocket engine. Thermo-fluid system simulation tools are used to analyze the pressurization process of a cryogenic tank. Most system level codes (GFSSP and ROCETS) use single node1 to represent ullage which is the gaseous space in the tank. Ullage space in a cryogenic tank is highly stratified because the entering inert gas is at ambient temperature whereas the liquid propellant is at a cryogenic temperature. A single node model does not account for the effect of temperature gradient in the ullage. High fidelity Navier-Stokes based CFD model of Tank Pressurization is not practical for running a long duration transient model with thousands and millions of nodes. A possible recourse is to construct a multi-node model with system level code that can account for ullage stratification.

Bandyopadhyay, Alak↗

Design progress of cryogenic hydrogen system for China Spallation Neutron Source

China Spallation Neutron Source (CSNS) is a large proton accelerator research facility with 100 kW beam power. Construction started in October 2011 and is expected to last 6.5 years. The cryogenic hydrogen circulation is cooled by a helium refrigerator with cooling capacity of 2200 W at 20 K and provides supercritical hydrogen to neutron moderating system. Important progresses of CSNS cryogenic system were concluded as follows. Firstly, process design of cryogenic system has been completed including helium refrigerator, hydrogen loop, gas distribution, and safety interlock. Secondly, an accumulator prototype was designed to mitigate pressure fluctuation caused by dynamic heat load from neutron moderation. Performance test of the accumulator has been carried out at room and liquid nitrogen temperature. Results show the accumulator with welding bellows regulates hydrogen pressure well. Parameters of key equipment have been identified. The contract for the helium refrigerator has been signed. Mechanical design of the hydrogen cold box has been completed, and the hydrogen pump, ortho-para hydrogen convertor, helium-hydrogen heat exchanger, hydrogen heater, and cryogenic valves are in procurement. Finally, Hydrogen safety interlock has been finished as well, including the logic of gas distribution, vacuum, hydrogen leakage and ventilation. Generally, design and construction of CSNS cryogenic system is conducted as expected.

43 PARTICLE ACCELERATORS↗

Advances in cryogenic engineering. Volume 33 - Proceedings of the Cryogenic Engineering Conference, Saint Charles, IL, June 14-18, 1987

Papers are presented on superconductivity applications including magnets, electronics, rectifiers, magnet stability, coil protection, and cryogenic techniques. Also considered are insulation, heat transfer to liquid helium and nitrogen, heat and mass transfer in He II, superfluid pumps, and refrigeration for superconducting systems. Other topics include cold compressors, refrigeration and liquefaction, magnetic refrigeration, and refrigeration for space applications. Papers are also presented on cryogenic applications, commercial cryogenic plants, the properties of cryogenic fluids, and cryogenic instrumentation and data acquisition.

Fast, R. W.↗

Cryogenic leak testing of tube fittings/valves

A high pressure and variable temperature cryogenic leak testing system was conceived and designed in order to conduct leakage testing of pipe fittings/valves in liquid hydrogen supply lines of the Space Shuttle. The system can create a continuous testing environment of variable temperature, 5.5 to about 300 K, and variable pressure, 0.01 to about 70 x 10 exp 5 Pa, with a large sample space, 90 mm diameter x 228 mm length, and at low operating cost. In terms of cryogenic leak testing the system has a special capability for extensive applications. The system comprised a variable temperature cryostat, a high pressure sample chamber, a vacuum pumping station, gas flow control system, pressure and temperature control systems, and leak detecting and measuring systems. A general discussion of cryogenic leak testing methods is also presented.

Jia, L. X.↗

Simulation of cryogenic liquid flows with vapor bubbles

Liquid flows in rocket engine components (such as bearings, seals, and pumps) often involve the formation of vapor bubbles due to local superheating of the fluid (either boiling or cavitation). Under the present effort, an analysis has been developed for liquid flows with vapor bubbles, based on a combined Eulerian-Lagrangian technique, in which the continuous (liquid) phase is treated by solving a system of Eulerian conservation equations, while the discrete (vapor bubble) phase is dealt with by integrating Lagrangian equations of motion in computational coordinates. Vapor bubbles of changing size can be accommodated easily by this analysis, and models for the simulation of bubble formation, growth, and motion have been included. The effect of bubble motion and other bubble processes on the continuous (liquid) phase has been accounted for by appropriate bubble mass, momentum, and energy interchange source terms in the Eulerian conservation equations. To demonstrate the viability of the resulting procedure, the cavitating flow of liquid oxygen through a simplified model of a labyrinth seal has been successfully calculated.

De Jong, Frederik J.↗

Ultra-high molecular sink vacuum chamber

Double-wall vacuum chamber can be separated from the remainder of the system and pumped by ultra-clean techniques. Ultrahigh vacuum is maintained by the cryogenic effect of a cold wall and titanium chemisorption.

Stephens, J. B.↗

Ames Research Center cryogenics program

Viewgraphs describe the Ames Research Center's cryogenics program. Diagrams are given of a fluid management system, a centrifugal pump, a flow meter, a liquid helium test facility, an extra-vehicular activity coupler concept, a dewar support with passive orbital disconnect, a pulse tube refrigerator, a dilution refrigerator, and an adiabatic demagnetization cooler.

Kittel, Peter↗

Computing Thermal Effects of Cavitation in Cryogenic Liquids

A computer program implements a numerical model of thermal effects of cavitation in cryogenic fluids. The model and program were developed for use in designing and predicting the performances of turbopumps for cryogenic fluids. Prior numerical models used for this purpose do not account for either the variability of properties of cryogenic fluids or the thermal effects (especially, evaporative cooling) involved in cavitation. It is important to account for both because in a cryogenic fluid, the thermal effects of cavitation are substantial, and the cavitation characteristics are altered by coupling between the variable fluid properties and the phase changes involved in cavitation. The present model accounts for both thermal effects and variability of properties by incorporating a generalized representation of the properties of cryogenic fluids into a generalized compressible-fluid formulation for a cavitating pump. The model has been extensively validated for liquid nitrogen and liquid hydrogen. Using the available data on the properties of these fluids, the model has been shown to predict accurate temperature-depression values.

Hosangadi, Ashvin↗

Direct diode pumped Ti:sapphire ultrafast regenerative amplifier system

Here, we report on a direct diode-pumped Ti:sapphire ultrafast regenerative amplifier laser system producing multi-uJ energies with repetition rate from 50 to 250 kHz. By combining cryogenic cooling of Ti:sapphire with high brightness fiber-coupled 450nm laser diodes, we for the first time demonstrate a power-scalable CW-pumped architecture that can be directly applied to demanding ultrafast applications such as coherent high-harmonic EUV generation without any complex post-amplification pulse compression. Initial results promise a new era for Ti:sapphire amplifiers not only for ultrafast laser applications, but also for tunable CW sources. We discuss the unique challenges to implementation, as well as the solutions to these challenges.

07 ISOTOPE AND RADIATION SOURCES↗