Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Critical Experiment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Delayed Critical Highly Enriched Uranium Metal Cylinders with Thin Graphite Top and Bottom Reflectors

Nine 7, 11, and 15 in. diam highly enriched uranium (HEU, 93.15 wt % 235 U) metal cylinders were assembled on the vertical assembly machine in the Oak Ridge Critical Experiments Facility (ORCEF) and had 1, 2, or 3 in. thick HLM graphite reflectors on the top and bottom. The experiments, which were performed between April 3, 1970, and February 18, 1971, used 23 operational days at ORCEF. Before those experiments were carried out, unreflected and unmoderated, graphite- and polyethylene-reflected, and polyethylene-moderated HEU metal cylinders had been assembled to obtain delayed criticality at ORCEF in the 1960s and reported by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) at the Nuclear Energy Agency (NEA)*. The data from the nine critical experiments are acceptable for use as criticality safety benchmark experiments for the NEA’s ICSBEP once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with HEU metal at ORCEF, the uncertainties in k eff are expected to be as low as ±0.0004.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integral Experiment Request 523 CED – 1 Report

This report documents the preliminary design phase of the Critical Experiment Design (CED-1) conducted as part of integral experiment request (IER) 523. The purpose of IER-523 is to determine critical configurations of 35 weight percent (wt%) enriched uranium dioxideberyllium oxide (UO 2 -BeO) material with Seven Percent Critical Experiment (7uPCX) fuels at Sandia National Laboratories (Sandia). Preliminary experiment design concepts, neutronic analysis results, and proposed paths for continuing the CED process are presented. This report builds on the feasibility and justification of experimental need report (CED-0) completed in December 2021.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integral Experiment Request 523 CED-2 Report

This report documents the final design phase of the Critical Experiment Design (CED-2) conducted as part of integral experiment request (IER) 523. The purpose of IER 523 is to determine critical configurations of 35 weight percent (wt%) enriched uranium dioxide beryllium oxide (UO 2 -BeO) material driven by an annular ring of Seven Percent Critical Experiment (7uPCX) fuel rods at Sandia National Laboratories (Sandia). The experiments will provide benchmark data on water moderated, intermediately enriched UO2 systems as well as Be nuclear data. The experiment will also provide partial validation for the beryllium oxide (BeO) thermal neutron scattering law (TSL) in the thermal energy range. Experiment design concepts, neutronic analysis results, and proposed paths for continuing the CED process are presented. This report builds on the feasibility and justification of experimental need report (CED-0) and preliminary experiment design report (CED-1) completed in December 2021 and September 2023, respectively [1, 2].

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NCERC Capabilities [Slides]

NCERC is our nation’s only generalpurpose critical experiments facility and is one of only a few that remain operational throughout the world. The mission of the National Criticality Experiments Research Center (NCERC) is to conduct experiments and training with critical assemblies and fissionable material at or near criticality in order to explore reactivity phenomena, and to operate the assemblies in the regions from subcritical through delayed critical. One critical assembly, Godiva-IV, is designed to operate above prompt critical.

61 RADIATION PROTECTION AND DOSIMETRY↗

Temperature Gradients on the Cell Wall in the Critical Viscosity Experiment

Because of the diverging susceptibility delta rho/delta Tau near the liquid-vapor critical point, temperature gradients must be kept small to maintain adequate sample homogeneity. In our Science Requirements Document we paid particular attention to radial density gradients caused by equilibration of the xenon sample. Axial density gradients were addressed through the requirement that the cell's copper wall have a gradient less than 22 microK/m. This report re-examines the cell wall's temperature distribution in more detail by estimating all known significant contributions to temperature differences on the cell's wall.

Berg, Robert F.↗

IER-517: Molybdenum Optimized Benchmark System Demonstrating Integral Correlations (MOBY DICK)

Nuclear criticality experiments are essential to the validation of nuclear data used in simulation software. The quality of nuclear data becomes paramount as simulation software becomes more relied upon for criticality safety studies and designs of nuclear systems. To improve the quality of nuclear data, experimenters can design critical experiments that are sensitive to isotope reaction pairs in materials of interest. The efforts conducted by the Organisation for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA) Working Party on Nuclear Criticality Safety (WPNCS) Subgroup 8: Preservation of Expert Knowledge and Judgement Applied to Criticality Benchmarks (SG8) to categorize benchmarks according to their usefulness for nuclear data validation have been of great importance. Based on the OECD studies benchmark experiments included in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook are concisely used by nuclear data evaluators, criticality safety engineers and others to validate nuclear data and simulation results. A lack of benchmarks sensitive to molybdenum in the (ICSBEP), particularly in the intermediate range, was noted by Los Alamos National Laboratory (LANL), the French Institut de Radioprotection et de Sûreté Nucléaire (IRSN), and Y-12 National Security Site prompting them to submit a joint integral experiment request to the Nuclear Criticality Safety Program (NCSP) in 2019. The request included both HEU and Plutonium systems in order to validate differential nuclear data focusing on the intermediate energy range but also includes thermal and fast configurations. This document represents the preliminary design work for a series of molybdenum integral experiments known as Molybdenum Optimized Benchmark System Demonstrating Integral Correlations (MOBY DICK).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Criticality Accidents in Experiments and Reactors [Slides]

The objectives of this presentation are to: (1) gain awareness of the historical timelines and trends associated with the occurrences of critical experiment accidents associated, (2) identify lessons learned from accidents with critical experiments and the development of standards for handling nuclear material and performance of critical experiments; and (3) to ensure trainees gain a working knowledge of the factors that lead to the accidents.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark of the Chlorine Worth Study Experiments in Support of Chlorine Nuclear Data Validation for Nuclear Criticality Safety

The Chlorine Worth Study (CWS) was a critical experiment to address an urgent need for thermal chlorine nuclear data validation in plutonium systems. This urgent need is tied directly to plutonium recycle and recovery operations in the plutonium facility at Los Alamos National Laboratory, where exceptionally conservative criticality safety limits are used because no credit is taken for the neutron capture by chlorine. The experiment used weapons-grade plutonium metal plates clad in stainless steel, known as the PANN (plutonium aluminum no nickel) ZPPR (zero power physics reactor) plates. The plutonium was reflected and moderated by high-density polyethylene and included combinations of polyvinyl chloride (PVC) and chlorinated polyvinyl chloride (CPVC) as absorbers. The experiment and benchmark included three configurations mimicking 30 g 239 Pu/L plutonium, 300 g 239 Pu/L plutonium, and 600 g 239 Pu/L plutonium in an aqueous chloride solution. Uncertainties in the benchmark included five broad categories: (1) criticality measurement, (2) mass and density, (3) dimensions, (4) material compositions, and (5) positioning. The largest contribution to the overall uncertainties for all three cases came from the material compositions, in particular the PVC and CPVC absorber compositions. A detailed model was created to be a near match (that is within expectations of transport code users) and a simplified model was created to minimize offset dimensions and expedite modeling for code validation. Sample calculations were completed in MCNP6.3 with ENDF/B-VIII.0 and ENDF/B-VII.1 nuclear data. For the detailed and simplified models, the average difference between the computed and experimental k eff was 951 pcm. CWS will serve as the key validation experiment for nuclear criticality safety in support of aqueous chloride operations. The sensitivity to the chlorine capture cross section is orders of magnitude greater than other existing benchmarks. The current limits, as defined by nuclear criticality safety, are 520 g Pu per batch, i.e. the minimum critical mass of the Pu solution infinitely reflected by water [Criticality Handbook: Volume II, (1969)]. This extremely conservative critical mass limit does not credit any neutron capture by chlorine (in particular neutron capture by 35 Cl) and greatly impedes the throughput required for current and future operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SCALE 6.2.4 Validation: Nuclear Criticality Safety

The computational bias of criticality safety computer codes must be established through the validation of the codes to critical experiments. A large collection of suitable experiments has been vetted by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook). More than 600 cases from this handbook have been prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID), which is maintained by the Reactor and Nuclear Systems Division at Oak Ridge National Laboratory. The performance of the KENO V.a and KENO-VI Monte Carlo codes within the SCALE 6.2.4 code system is assessed using the VALID models of benchmark experiments. A range of nuclear cross section libraries based on Evaluated Nuclear Data File (ENDF)/B-VII.1 in both multigroup (MG) and continuous energy (CE) formats is considered. The critical experiments available to validate the KENO V.a code cover 15 broad categories of systems. These systems use a range of fissile materials, including a range of uranium enrichments, various plutonium isotopic vectors, and some mixed uranium/plutonium oxides. The physical forms of the fissile material also vary and are represented as metal, solutions, or arrays of rods or plates in a water moderator. The neutron energy spectra of the systems also vary and cover fast, intermediate, mixed, and thermal spectra. Over 550 of the total cases use the KENO V.a code for the four nuclear data libraries considered in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fluids flight hardware

The following are discussed in this viewgraph presentation: Glovebox-2 investigations, study of oscillatory thermocapillary flows and validate physical models on the second U.S. Microgravity Laboratory Mission (USML-2), pool boiling experiment, critical fluid viscosity measurement experiment, Hitchhiker-G typical structural configuration, ZENO-critical fluid light scattering experiment, isothermal dendritic growth experiment, microgravity acceleration environment support, and the space acceleration measurement system (SAMS).

Shaw, Nancy↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Lithium Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility

One of the main goals of the Thermal/Epithermal eXperiments (TEX) project is to use existing Nuclear Criticality Safety Program (NCSP) assets to create critical experiment plutonium and uranium test beds for materials important to criticality safety that have insufficient benchmark evaluations. The plutonium test bed experiments were completed in 2018 and are published in the 2020 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The uranium test bed assemblies were completed in 2023 and accepted in the 2024 edition of the ICSBEP Handbook. The Nuclear Criticality Safety (NCS) group at Y-12 National Security Complex has identified programmatic need for validation cases for uranium electrorefining operations at Y-12. The electrorefining operation credits lithium enriched in 6 Li in addition to 35 Cl as absorbers in the design criticality safety evaluation for precluding criticality under upset conditions in the large and geometrically unfavorable electro-refiner. There is, however, inadequate experimental validation for the 6 Li absorbers. As an extension of the TEX uranium test bed, TEX-Cl critical experiments were performed with sodium chloride salt to address the 35 Cl thermal absorption as well as other validation needs at Los Alamos National Laboratory (LANL). These experiments were completed in 2024 and accepted into the 2025 ICSBEP Handbook. To continue the methodology used in TEX-Cl, TEX-Li aims to accomplish the same. The overall design of both experiments was to use commercially available, high purity, salts with polyethylene moderator and HEU plates to configure a critical assembly. Three experiments are planned for TEX-Li using encapsulated lithium carbonate (Li 2 CO 3 ), with natural 6 Li abundance. For all experiments, the highly enriched uranium (HEU) Jemima plates will be used as fissile material. Multiple layers will be stacked together with encapsulated Li 2 CO 3 alternated with polyethylene in standard configurations. Standard stacking was found to be optimal in matching the different sensitivity profiles provided by the Y-12 models. Three configurations are proposed with varying polyethylene moderation and a constant 1/4” absorber thickness. The first uses 11 layers of 5/4” polyethylene, the second uses 9 layers of 3/4” polyethylene, and the third uses 10 layers of 1/2” polyethylene. Calculations showed that some alternative forms of lithium-based materials provided slightly less-optimal sensitivity profiles when compared to lithium carbonate but come with other drawbacks. These alternatives included lithium aluminate (LiAlO 2 ), Aluminum-2050 alloy, Aluminum-8090, Aluminum-2095, lithium hydride (LiH), and lithium fluoride (LiF). Lithium aluminate and aluminum-2050 provided comparable sensitivity profiles when compared to lithium carbonate and can be used instead if lithium carbonate cannot be readily procured. After a broad material study, lithium carbonate outperformed any alternative material with a balance in affordability and workability. The assessment of experimental uncertainties of the non-absorber and absorber components was predicted to be 0.00089 and 0.00093 Δk eff , respectively. The largest uncertainties may be reduced with precision dimensional inspection of the components. Many of the parts and equipment for IER 575 have already been fabricated or procured for previous projects and therefore do not contribute significantly to the overall cost of this experiment. This includes the Jemima plates and Comet critical assembly machine, which are existing NCSP assets, as well as the aluminum platen and polyethylene reflector rings, which were fabricated and authorized for the TEX experiment involving HEU with polyethylene. Lithium carbonate containers will be procured by LANL and will be filled by LLNL. The total material costs for TEX-Li experiments are estimated to be on the order of $\$$47,400. Precision inspection, including dimensional, mass, density, and impurity, is recommended for all components for an estimated cost of $\$$12,000.

35Cl↗

Comparison of Measured and Simulated Neutron Counting with 3He Detectors and the Subcritical Water-Moderated UO2 7uPCX Assembly

An experiment designed to compare neutron noise analysis techniques on subcritical assemblies using differing neutron detector designs was developed as a collaborative effort between the Institut de radioprotection et de surete nucleaire (IRSN), Los Alamos (LANL), Lawrence Livermore (LLNL), and Sandia National Laboratories. This experiment has the final goal of characterizing neutron noise analysis accuracy in determining multiplication in light water systems for various neutron detection systems. This experiment utilized the Seven Percent Critical Experiment (7uPCX) facility at Sandia National Laboratories. The 7uPCX is an assembly designed to investigate light water systems with fuel enrichment above 5% and is able to use square or hex grid plates with varying pitches.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exobiological exploration of Mars

Of all the other planets in the solar system, Mars remains the most promising for further elucidating concepts about chemical evolution and the origin of life. Strategies were developed to pursue three exobiological objectives for Mars exploration: determining the abundance and distribution of the biogenic elements and organic compounds, detecting evidence of an ancient biota on Mars, and determining whether indigenous organisms exist anywhere on the planet. The three strategies are quite similar and, in fact, share the same sequence of phases. In the first phase, each requires global reconnaissance and remote sensing by orbiters to select sites of interest for detailed in situ analyses. In the second phase, lander missions are conducted to characterize the chemical and physical properties of the selected sites. The third phase involves conducting 'critical' experiments at sites whose properties make them particularly attractive for exobiology. These critical experiments would include, for example, identification of organics, detection of fossils, and detection of extant life. The fourth phase is the detailed analysis of samples returned from these sites in Earth-based laboratories to confirm and extend previous discoveries. Finally, in the fifth phase, human exploration is needed to establish the geological settings for the earlier findings or to discover and explore sites that are not accessible to robotic spacecraft.

Klein, H. P.↗

Exobiological Exploration of Mars

Of all the other planets in the solar system, Mars remains the most promising for studying concepts about chemical evolution and the origin of life. Strategies were developed to pursue three exobiological objectives for Mars: determine abundance and distribution of biogenic elements and organic compounds, detect evidence of an ancient biota, and determine if organisms exist anywhere on the planet. The three strategies share the same sequence of phases. In the first phase, each requires global reconnaissance and remote sensing by orbiters to select sites of interest for detailed in situ analyses. In the second phase, lander missions are conducted to characterize the chemical and physical properties of the selected sites. The third phase involves conducting "critical" experiments at sites whose properties make them particularly attractive for exobiology. These critical experiments would include, for example, identification of organics, detection of fossils, and detection of extant life. The fourth phase is the detailed analysis of samples returned from these sites in Earth-based laboratories to confirm and extend previous discoveries. Finally, in the fifth phase, human exploration is needed to establish the geological context or to discover and explore sites that are not accessible to robotic spacecraft.

DeVincenzi, Donald L.↗

Resolved resonance region evaluations of n+ 206,207,208 Pb for fast spectrum applications

Resolved resonance region evaluations of the major isotopes of natural lead, 206 Pb, 207 Pb, 208 Pb, have been per formed to support the development of Generation IV reactors. In this study, validation of nuclear data for lead fast reactors was performed with simulations of shielding benchmarks, integral critical benchmarks, and quasi-differential scattering measurements. Sensitivity analyses of these systems showed that elastic scattering reactions above 100 keV were the dominant reactions driving system performance. The resolved resonance regions (RRRs) of the lead isotopes extend past 100 keV, making the RRR an ideal starting point to evaluate lead cross sections. Since the R-matrix requires knowledge of bound, distant, and observed resonances, it was necessary to evaluate from 10 -5 eV up to the respective limit of the RRR. The 208 Pb RRR evaluation was extended to 1.5 MeV in order to obtain resonance parameters used to calculate new elastic scattering angular distributions up to 1.5 MeV. Resonance parameter uncertainties and covariance were generated using the R-matrix code SAMMY. The new RRR parameters show a direct improvement to the scattering kernel below 1.5 MeV which in turn greatly improves fast critical experiments over ENDF/B-VIII.0.

206Pb↗

Horizontal Split Table Conceptual Design for Validation of Nuclear Data used in Advanced Reactors [Slides]

A methodology to create conceptual designs of benchmark critical experiments for advanced reactors nuclear data testing and validation was developed. A first concept was explored, pebble-bed high-temperature gas cooled reactor, based on the HTR-10 reactor. The very high correlation is a proof of concept that the design is similar to the application, and performing such critical experiments would help nuclear data testing and validation. This proof-of-concept was included in the IER-539 CED-1:Preliminary Design of a New Horizontal Split Table report. Other concepts could be explored if needed, such as Molten-salt reactor, Sodium-cooled fast reactor or Heat pipe reactors/Microreactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pitch Variation Experiments in Water-Moderated Square-Pitched U(6.90)O 2 Fuel Rod Lattices with Fuel to Water Volume Ratios Spanning 0.08 to 0.67

The US Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories. The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5 % 235 U. The 7uPCX assembly is a water-moderated and -reflected array of aluminum-clad square-pitched U(6.90 %)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMPTHERM- 096, LEU-COMP-THERM-097, and LEU-COMP-THERM-101. The fuel used in these experiments was fabricated using unirradiated 6.90 % enriched UO 2 fuel pellets from fuel elements designed to be used in the internal nuclear superheater section of the Pathfinder boiling water reactor operated in South Dakota by the Northern States Power Company in the 1960s. The fuel elements were obtained from The Pennsylvania State University where they had been stored for many years. The fuel pellets in those fuel elements were removed from the original Incoloy cladding and reclad in 3003 aluminum tubes and end caps for use in the experiments reported here. The purpose of these experiments was to measure the effects of decreasing the fuel-to-water volume ratio on the critical array size. This was accomplished by removing fuel rods from fully fueled configurations, effectively increasing the pitch of the fuel arrays in the assembly. The fuel rod pitch variations provided assembly configurations that ranged from strongly undermoderated to slightly overmoderated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Generating Models of the Flattop Critical Assembly for Benchmark Experiments with Python

Los Alamos National Laboratory has been performing nuclear criticality experiments since 1946 at the Pajarito site, starting the Los Alamos Critical Experiments Facility in 1948. A transition period occurred between 2004 and 2011 as operations moved to the National Criticality Experiments Research Center (NCERC), where criticality experiments are now performed. Criticality experiments are essential for determination and verification of nuclear data used in calculations and modeling—such as radiation transport codes—throughout the industry, enhancing nuclear criticality safety. In addition to nuclear data validation and benchmarking, the remotely operated critical assemblies at NCERC are used for a variety of experiments and training classes supporting criticality safety.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗