Analysis of Molten Salt Thermal Energy Storage Tank Sizing and Preheating
Molten Salt Thermal energy storage (TES) is essential for concentrating solar power (CSP) plants, enhancing their capacity factor and dispatchability to ultimately reduce electricity costs. This technology is becoming more important for other technologies including nuclear power, thermal-electrical storage, and concentrating solar thermal (CST). While molten salt TES tanks have been successfully deployed in lower-temperature parabolic-trough plants, the current state-of-the-art central receiver systems operating at temperatures up to 565 degrees Celsius have experienced costly and frequent failures. These failures are associated with the immaturity of the technology and problems in tank design, fabrication, commissioning and, sometimes, aggressive operation. A primary contributing factor is the absence of a dedicated technical standard for high-temperature molten nitrate TES tanks; designers must currently rely on existing codes like API 650 and ASME Section II, which are insufficient because they fail to account for the unique demands of high temperatures, thermal cycling, and transient conditions.