Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Formulations and analysis of Compton scattering for deterministic thermal radiation transport

In high-energy-density physics at low densities and high temperatures, Compton scattering can be the dominant interaction mechanism between thermal radiation and the material. Boson statistics leads to induced scattering, where the rate of scattering is proportional to the square of the photon intensity. To explore the importance of this nonlinear effect in the context of thermal radiative transfer, in this work we formulate several linear approximations to the scattering rate and compare them to the proper nonlinear rate in an infinite-medium setting. With the goal of implementing Compton scattering in a radiation transport code, we study heating-rate accuracy and iterative convergence properties for the linear methods as we vary the fidelity of the discretization in photon frequency. We find the equilibrium out-scattering formulation to be the most accurate linear method, with heating rate errors around 15% when the radiation is heating the material and up to 50% when the radiation is cooling the material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Developing a diagnostic for energetic laser-Compton produced photon beams

This paper describes the design and simulation of a radiation detector system for diagnostic measurements of photon beams produced by Thomson or Compton Scattering. The photon beam is Compton scattered in a thin passive converter, and the resulting electrons are analyzed using a charge-coupled device-based tracker and classification algorithms. The flux of the scattered electrons is much lower than that of the photon beam and is additionally dispersed. This dispersal enables measurements while avoiding pileup, which is important in order to provide diagnostic information from intense 'shot’ based pulsed systems, such as those being built to leverage laser wakefield accelerators. Simulations indicate that the designed system is capable of resolving beam parameters from a single shot. The fidelity to which various beam parameters can be resolved is presented as are methods that could result in further improvement to diagnostic resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CLARION2-TRINITY: A Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of backlighting sources for a Compton radiography diagnostic of inertial confinement fusion targets (invited)

We present scaled demonstrations of backlighter sources, emitting bremsstrahlung x rays with photon energies above 75 keV, that we will use to record x-ray Compton radiographic snapshots of cold dense DT fuel in inertial confinement fusion implosions at the National Ignition Facility (NIF). In experiments performed at the Titan laser facility at Lawrence Livermore National Laboratory, we measured the source size and the bremsstrahlung spectrum as a function of laser intensity and pulse length from solid targets irradiated at 2x10{sup 17}-5x10{sup 18} W/cm{sup 2} using 2-40 ps pulses. Using Au planar foils we achieved source sizes down to 5.5 {mu}m and conversion efficiencies of about 1x10{sup -13} J/J into x-ray photons with energies in the 75-100 keV spectral range. We can now use these results to design NIF backlighter targets and shielding and to predict Compton radiography performance as a function of the NIF implosion yield and associated background.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compton Polarimetry at ELSA

Part of the future polarization program performed at the Bonn accelerator facility ELSA will rely on precision Compton polarimetry of the stored transversely polarized electron beam. Precise and fast polarimetry poses high demands on the light source and the detector which were studied in detail performing numerical simulations of the Compton scattering process. In order to experimentally verify these calculations, first measurements were carried out using an argon ion laser as light source and a prototype version of a counting silicon microstrip detector. Calculated and measured intensity profiles of backscattered photons are presented and compared, showing excellent agreement. Background originating from beam gas radiation turned out to be the major limitation of the polarimeter performance. In order to improve the situation, a new polarimeter was constructed and is currently being set up. Design and expected performance of this polarimeter upgrade are presented.

43 PARTICLE ACCELERATORS↗

Observation of pulsed x-ray trains produced by laser-electron Compton scatterings

X-ray generation based on laser-electron Compton scattering is one attractive method to achieve a compact laboratory-sized high-brightness x-ray source. We have designed, built, and tested such a source; it combines a 50 MeV multibunch electron linac with a mode-locked 1064 nm laser stored and amplified in a Fabry-Perot optical cavity. We directly observed trains of pulsed x rays using a microchannel plate detector; the resultant yield was found to be 1.2x10{sup 5} Hz in good agreement with prediction. We believe that the result has demonstrated good feasibility of linac-based compact x-ray sources via laser-electron Compton scatterings.

43 PARTICLE ACCELERATORS↗

Polarized Compton Scattering and Nucleon Spin Polarizabilities at the Upgraded HI{gamma}S Facility

The HI{gamma}S facility is capable of providing intense beams of linearly and circularly polarized gamma rays, at energies from 2 MeV and soon to extend up to 100 MeV. This paper describes a Compton scattering program which has been designed to measure the electric and magnetic polarizabilities of the proton and the neutron, as well as the spin-polarizabilities of both. Linearly polarized beams will be used to measure the electric and magnetic polarizabilities of the proton, while Compton scattering from the deuteron will lead to values of these fundamental quantities for the neutron. Circularly polarized beams and polarized proton and {sup 3}He targets will be used to extract the four spin-polarizabilities of the nucleons with accuracies ranging from 5-to-25%. These values will be compared to the predictions of Chiral Perturbation Theory and anticipated results from Lattice QCD calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quality Control of Pavements and Tarmacs Using ({sup 137}Cs){gamma} Compton Scattering

The {gamma} Compton scattering over a volume of concrete has been studied in order to design an instrument for density measurements. It will be used for the quality control in road construction, where large surfaces must be monitored. The experimental results and Monte Carlo simulations of the {gamma} Compton scattering over homogeneous and inhomogeneous volumes of concrete are shown. MC simulations have been useful to optimize the values of several parameters to improve the experimental set up and to estimate the extension of the explored volume.

42 ENGINEERING↗

Observational Possibility of the Early GRBs using a Gaseous Electron Tracking Compton Camera in sub-MeV and MeV regions

GRBs have been recently known as a unique probe to catch the highest z galaxies and stars. Here I propose the new trigger method to catch high-z GRBs with z>10 efficiently by imaging sub-MeV gamma rays from GRBs. We have developed the Electron Tracking Compton Camera (ETCC) with reconstructing tracks of the recoil electron in Compton process to explore the MeV gamma-ray astronomy. By measuring the track of a recoil electron, the direction of the incident gamma ray is determined for each photon, which enables us to reconstruct the direction of GRBs by detecting only several ten photons (>100 keV). Ability of the large ETCC (100 cm{sup 2} effective area) to detect GRBs with z{approx}20 is revealed, based on the results of the balloon experiment and laboratory imaging test using the small ETCC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchro-Curvature Self Compton Radiation: A New Possible Radiation Mechanism

We calculate the self Compton spectrum of synchro-curvature radiation of power-law distributed electrons. We find that the resulting spectrum can be different from the traditional radiation mechanisms if parameters are within the proper range. This result could be considered as a universal approach of moving electron's self Compton emission, and could be applied to many astrophysical phenomena, including GRBs and pulsars. We also discuss the cooling effect of electron distribution as well as Klein-Nishina cutoff in order to get a more accurate picture.

79 ASTRONOMY AND ASTROPHYSICS↗

Compton profile study of polycrystalline ZnBr{sub 2}

The first ever Compton profile study of polycrystalline ZnBr{sub 2} is presented in this paper. The measurement of polycrystalline sample of ZnBr{sub 2} is performed using 59.54 keV gamma-rays emanating from an {sup 241}Am radioisotope. Theoretical calculations are performed following the Ionic model calculations for a number of configurations Zn{sup +x}Br{sub 2}{sup -x/2}(0.0{<=}x{<=}2.0 in step of 0.5) utilizing free atom profiles. The ionic model suggest transfer of 2.0 electrons from 4 s state of Zn to 4 p state of two Br atoms. The autocorrelation function B(z) is also derived from experiment and the most favoured ionic valence Compton profiles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Polaritonic pulse and coherent X- and gamma rays from Compton (Thomson) backscattering

The formation of polariton wave-packets created by high-intensity laser beams focused in plasmas is analyzed, and the velocity, energy, size, structure, stability, and electron content of such polaritonic pulses are characterized. It is shown that polaritonic pulses may transport trapped electrons with appreciable energies, provided the medium behaves as a rarefied classical plasma. The relativistic electron energy is related to the polariton group velocity, which is close to the velocity of light in this case. The plasma pulse is polarized, and the electron number in the pulse is estimated as being proportional to the square root of the laser intensity and the 3/2-power of the pulse size. It is shown that Compton (Thomson) backscattering by such polaritonic pulses of electrons may produce coherent X- and gamma rays, as a consequence of the quasirigidity of the electrons inside the polaritonic pulses and their relatively large number. The classical results of the Compton scattering are re-examined in this context, the energy of the scattered photons and their cross-section are analyzed, especially for backscattering, the great enhancement of the scattered flux of X- or gamma rays due to the coherence effect is highlighted and numerical estimates are given for some typical situations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Study on ion-irradiation-induced ferromagnetism in FeRh intermetallic compound by means of magnetic Compton scattering

The magnetic Compton profiles of Fe-50 at. % Rh intermetallic compound were measured to study the ferromagnetism induced by 200 MeV Xe ion irradiation. The magnetic effect at 50 K increases with increasing the ion-fluence. The analysis of the experimental result revealed that the values of spin moment induced by the irradiation were close to the values of magnetization obtained by a superconducting quantum interference device magnetometer, suggesting that the ion irradiation mainly induces the spin magnetic moment. The difference in magnetic Compton profiles between the irradiation-induced ferromagnetism and the intrinsic ferromagnetism in pure Fe is also discussed.

36 MATERIALS SCIENCE↗

Development of Compton radiography of inertial confinement fusion implosions

An important diagnostic tool for inertial confinement fusion will be time-resolved radiographic imaging of the dense cold fuel surrounding the hot spot. The measurement technique is based on point-projection radiography at photon energies from 60 to 200 keV where the Compton effect is the dominant contributor to the opacity of the fuel or pusher. We have successfully applied this novel Compton radiography technique to the study of the final compression of directly driven plastic capsules at the OMEGA facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)]. The radiographs have a spatial and temporal resolution of {approx}10 {mu}m and {approx}10 ps, respectively. A statistical accuracy of {approx}0.5% in transmission per resolution element is achieved, allowing localized measurements of areal mass densities to 7% accuracy. The experimental results show 3D nonuniformities and lower than 1D expected areal densities attributed to drive asymmetries and hydroinstabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First refraction contrast imaging via Laser-Compton Scattering X-ray at KEK

Laser-Compton Scattering (LCS) is one of the most feasible techniques for high quality, high brightness, and compact X-ray source. High energy electron beam produced by accelerators scatters off the laser photon at a small spot. As a laser target, we have been developing a pulsedlaser storage cavity for increasing an X-ray flux. The X-ray flux was still inadequate that was 2.1 Multiplication-Sign 10{sup 5}/sec, however, we performed first refraction contrast imaging in order to evaluate the quality of LCS X-ray. Edge enhanced contrast imaging was achieved by changing the distance from sample to detector. The edge enhancement indicates that the LCS X-ray has small source size, i.e. high brightness. We believe that the result has demonstrated good feasibility of linac-based high brightness X-ray sources via laser-electron Compton scatterings.

43 PARTICLE ACCELERATORS↗

Development of Compton gamma-ray sources at LLNL

Compact Compton scattering gamma-ray sources offer the potential of studying nuclear photonics with new tools. The optimization of such sources depends on the final application, but generally requires maximizing the spectral density (photons/eV) of the gamma-ray beam while simultaneously reducing the overall bandwidth on target to minimize noise. We have developed an advanced design for one such system, comprising the RF drive, photoinjector, accelerator, and electron-generating and electron-scattering laser systems. This system uses a 120 Hz, 250 pC, 2 ps, 0.35 mm mrad electron beam with 250 MeV maximum energy in an X-band accelerator scattering off a 150 mJ, 10 ps, 532 nm laser to generate 5 Multiplication-Sign 10{sup 10} photons/eV/s/Sr at 0.5 MeV with an overall bandwidth of less than 1%. The source will be able to produce photons up to energies of 2.5 MeV. We also discuss Compton scattering gamma-ray source predictions given by numerical codes.

43 PARTICLE ACCELERATORS↗

Spin and orbital magnetization loops obtained using magnetic Compton scattering

We present an application of magnetic Compton scattering (MCS) to decompose a total magnetization loop into spin and orbital magnetization contributions. A spin magnetization loop of SmAl{sub 2} was measured by recording the intensity of magnetic Compton scattering as a function of applied magnetic field. Comparing the spin magnetization loop with the total magnetization one measured by a vibrating sample magnetometer, the orbital magnetization loop was obtained. The data display an anti-coupled behavior between the spin and orbital magnetizations and confirm that the orbital part dominates the magnetization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Compton scattering for spectroscopic detection of ultra-fast, high flux, broad energy range X-rays

Compton side-scattering has been used to simultaneously downshift the energy of keV to MeV energy range photons while attenuating their flux to enable single-shot, spectrally resolved, measurements of high flux X-ray sources to be undertaken. To demonstrate the technique a 1 mm thick pixelated cadmium telluride detector has been used to measure spectra of Compton side-scattered radiation from a Cobalt-60 laboratory source and a high flux, high peak brilliance X-ray source of betatron radiation from a laser-plasma wakefield accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗