Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗

Supplemental defatted microalgae affects egg and tissue fatty acid composition differently in laying hens fed diets containing corn and flaxseed oil

Effects of defatted microalgae (DFA) on fatty acid composition of eggs and tissues of hens have not been well studied. This experiment was to determine how low concentrations of supplemental DFA in the presence or absence of flaxseed oil (FO) altered fatty acid profiles of egg yolk, liver, adipose tissue, and plasma of layers. A total of 60 Shaver Leghorn layer hens (individually caged, 20-wk old) were allotted into 6 groups (n = 10) and fed a corn/soybean meal basal diet containing 0, 3, or 5% DFA and 0 (1.5% corn oil, CO) or 1.5% FO for 6 wk. BW, ADFI, egg production rate, and egg component weights were not affected by any of the dietary treatments at various time points, but egg yolk color was changed (P < 0.05) with increasing concentrations of DFA. The concentration of n-3 fatty acids in egg yolk and plasma were elevated by FO up to 9-fold (P < 0.05) starting at wk 1 or 2, and 39 to 83% (P < 0.05) by DFA. Supplemental DFA improved (P < 0.05) n-6/n-3 fatty acid ratios in egg yolk and plasma from 13 to 23 and 7 to 13, respectively, only in hens fed diets without FO. Fatty acid profiles of liver and adipose tissue (at wk 6) displayed responses to supplemental DFA and FO similar to those of egg yolk or plasma. In conclusion, supplemental 3 or 5% DFA caused moderate enrichments of n-3 fatty acids and decreased the n6/n3 fatty acid ratios of egg yolk and tissues in hens fed diets without FO.

59 BASIC BIOLOGICAL SCIENCES↗

Sniffer used as portable hydrogen leak detector

Sniffer type portable monitor detects hydrogen in air, oxygen, nitrogen, or helium. It indicates the presence of hydrogen in contact with activated palladium black by a change in color of a thermochromic paint, and indicates the quantity of hydrogen by a sensor probe and continuous readout.

Dayan, V. H.↗

Simplified technique demonstrates magnetic domain switching

Light from a conventional photographic light source is polarized and projected through thin samples of gadolinium iron garnet and then observed with a conventional polarizing microscope. A distinctive change in color from red to yellow is observed as the magnetic domains are switched.

Source record↗

Use of satellite imagery for wildland resource evaluation in the Great Basin

The author has identified the following significant results. Upon receipt of ERTS-1 imagery, scale and resolution determinations were made. It was found that the scale was quite close to the anticipated 1:1 million, and that each ERTS-1 frame had a coverage of approximately 12,500 square miles. A water body 275 feet across was identified on the MSS 7 band as a determination of maximum resolution. Large cities were easily distinguished on all bands. Paved highways and railroads were able to be identified when there was extreme contrast between these structures and surrounding areas. Landforms were identified on all bands, but band 5 proved superior. Vegetation of varying types was identified using band 7. Fields and agricultural areas were identified as was phreatophytic vegetation. Timber, pinyon-juniper, sagebrush, mountain brush, and annual grassland communities were identified on selected frames. Phenology comparisons of selected test sites were made using sequential U-2 imagery. It was found that gray scale and color IR changes relating to the phenology of certain annual grassland, mountain brush, and marsh communities could be identified. Water bodies were identified and delineated using band 7.

Tueller, P. T.↗

Skylab analysis of San Francisco Bay

The distribution and volume of sediment present in suspension during the Skylab 4 overpass for San Pablo Bay and the Carquinez Strait is studied along with the movement and eventual distribution of both natural and dredged sediment in San Francisco Bay. The most useful Skylab sensor film is found to be the S-190B color photography. Changes in temperature, dissolved oxygen, pH, salinity, and pollutants information simultaneously collected are correlated with the spectral differences observed in the various Skylab data. The techniques outlined should be applicable for coastal and estuarine process studies in other areas. A suspensate concentration of about 2 mg/liter is quite sufficient to tag a surface current system, and the surface structure of currents with over 250 mg/liter can be imaged by using progressively longer wavelength filters.

Steller, D. D.↗

Theory of spectral radiance of pollutants at sea

Remote measurement of soluble pollutants that change the color of the water in the sea is reported. The sensor is a spectral radiometer that flies over the polluted area and compares its spectral radiance to that of surrounding clean seawater. A quantitative analysis of the concentration of pollutants using the measured radiance of the sea compared to laboratory measurements of reflection and transmission spectra of the pollutants is presented. The quantities involved are defined and means for measuring them are described. The equations for remote sensing with a low-flying aircraft, in which case the absorption and radiance of intervening air is negligible are derived. High-flying aircraft and satellites, in which case the radiance of intervening air is the major problem are applied.

Source record↗

Theory of spectral radiance of pollutants at sea, volume 1

Remote measurement of pollutants dumped in the sea, not oil slicks, but soluble pollutants that change the color of the water, is addressed. The sensor is a spectral radiometer that flies over the polluted area and compares its spectral radiance (color) to that of surrounding clean seawater. The goal is to infer the concentration of pollutants using the measured radiance of the sea compared to laboratory measurements of reflection and transmission spectra of the pollutants. The subject is treated in three steps: (1) the quantities involved are defined and means for measuring them are described; (2) the equations for remote sensing with a low-flying aircraft are derived, in which wase the absorption and radiance of intervening air is negligible; and (3) high-flying aircraft and satellites are applied, in which case the radiance of intervening air is the major problem.

Source record↗

A simple method for monitoring surface temperatures in plasma treatments

A method consisting of applying temperature markers on the specimen is described for measuring the highest temperature reached by very thin films in situ during deposition. In the first test setup, lowering the input power to 500 W only effected the 177-C marker, while increasing the input power to 1.25 kW effected the 274-C marker. In tests conducted in a dc plasma with markers placed on the uncooled cathode in Ar plasma, the maximum temperatures indicated by the thermocouple matched a change in color of the markers, and no effect of earlier sublimation or decomposition was noted.

Manory, R. R.↗

Effects of Pressure on Microgravity Hydrocarbon Diffusion Flames

The effect of pressure on the propane diffusion flames burning in quiescent air under both normal-gravity and microgravity conditions (in the NASA's 2.2-Second Drop Tower at the Lewis Research Center) were studied at pressures of 0.5, 1.0, and 1.5 atm, with three fuel mass-flow rates for each pressure. Compared to normal-gravity flames, the microgravity tests showed enhanced sooting, tip-opening, and soot escape, accompanied with changes in color, size, and luminosity of the flames. At low pressures, less-efficient burning and a broader flame zone was found to exist due to the kinetics effects, while at high pressures, where was more soot and longer soot-burning zones. Results show that there exist a particular intermediate pressure at which both the microgravity and normal-gravity flame heights are minimized.

Bahadori, M. Yousef↗

Liquid-Crystal Coats Help Make Flows Visible

Visible indication of transition of boundary layer from laminar to turbulent flow plays important role in aerodynamic tests in wind tunnels and in flight. In newly developed method, liquid-crystal coats used to make visible such features of boundary-layer flows as transitions, separations, and locations of shocks. Changes of color rapid and reversible. For flight applications, provides capability for making transitions visible throughout almost entire altitude and speed ranges of subsonic aircraft. Also applicable to visible indication of supersonic flows and suitable for general use in high- and low-speed wind-tunnel and water-tunnel testing.

Holmes, Bruce J.↗

Diffraction limited infrared images of the binary star T Tauri

High-resolution images of T Tau and its infrared companion have been reconstructed from near- and midinfrared data collected at the Hale 5-m telescope. The near-infrared (1-5 microns) results were obtained by 2D speckle imaging and the midinfrared (10-20 microns) results were derived from shift-and-add procedures applied to slit scans. The spectral energy distributions of the separated components were constructed from 1- to 20-micron data collected in less than half a year (September 1990 to January 1991). The spectral energy distribution of the optical component (T Tau N) is interpreted as containing two distinct constituents, a photosphere and a surrounding disk of circumstellar material. Measurements at a number of infrared wavelengths over the period December 1985 to January 1991 show a 2-mag color-independent change in the brightness of the infrared component (T Tau S). It is proposed that this may have been caused by an increase in accretion onto T Tau S and model the spectral energy distribution of T Tau S as being dominated by an accretion disk.

Ghez, A. M.↗

Chemical Dosimeter Tube With Coaxial Sensing Rod

Improved length-of-stain (LOS) chemical dosimeter indicates total dose of chemical vapor in air. Made with rods and tubes of various diameters to obtain various sensitivities and dynamic ranges. Sensitivity larger and dose range smaller when more room for diffusion in gap between tube and rod. Offers greater resistance to changing of color of exposed dye back to color of unexposed condition, greater sensitivity, and higher degree of repeatability. Developed to measure doses of gaseous HCI, dosimeter modified by use of other dyes to indicate doses of other chemical vapors.

Lueck, Dale E.↗

Dosimeter Badge Detects Hydrazines

Disposable dosimeter badge indicates approximate cumulative exposure to hydrazine or monomethyl hydrazine in air. Indication is change in colors of both paper tapes; one coated with para-N, N-dimethylaminobenzaldehyde. Colors of exposed tapes compared with colors on two preprinted color wheels to obtain estimate of exposure. Badges help minimize risks associated with exposure of personnel to hydrazine or monomethyl hydrazine, or suspected carcinogens. Also used as stationary monitors by taping them on walls or equipment at strategic locations.

Young, Rebecca C.↗

Temperature-indicating Paints

This report is an attempt at a new method of coating the surface of the cylinder with materials that undergo chemical change at definite temperatures as indicated by a change in color. In this way it was hoped that the substance itself would indicate directly the position of its isotherms, which in measurements with thermocouples requires a tedious amount of labor.

Penzig, F↗

Apollo 16 core 60013/14 as a product of path 1 and path 2 regolith evolution processes

We have made a petrographic study of 12 samples along the 62 cm profile of Apollo 16 core 60013/14 taken at Station 10 near the lunar module. The basic core description and maturity variations have been discussed earlier. This core is important because it enables a stratigraphic comparison with nearby cores 60001-7 and 60009/10. These cores form a triangle with sides 35-40 m. FMR data show a maturity-match between 60009/10 and 60013/14. Unfortunately, segments of the core 60001-7 are too disturbed for any cm scale comparison. We present new data on the grain size distribution and the modal petrography for six samples from six levels of 60013 using the same approach and rationale used for 60014. We have combined the new data with our previous data on 60014 to plot the variations of grain size distributions and grain type abundances, in the 500-1000 m and 90-150 micrometers size fractions, with depth. Agglutinate abundances match the I sub s/FeO profile and both show a significant break at a depth of about 45 cm, with lower maturity material below that point. Grain size distributions show that for all analyzed samples, the mean grain size is below 90 micrometers. The two lowest samples are somewhat more coarse-grained than the rest of the core. The break at about 45 cm is the most prominent feature of the core and was described during the initial dissection as a pronounced change in color from dark to light. It now seems clear that this break is primarily one of maturity rather than of bulk chemical composition.

Basu, A.↗

More About The Video Event Trigger

Report presents additional information about system described in "Video Event Trigger" (LEW-15076). Digital electronic system processes video-image data to generate trigger signal when image shows significant change, such as motion, or appearance, disappearance, change in color, brightness, or dilation of object. Potential uses include monitoring of hallways, parking lots, and other areas during hours when supposed unoccupied, looking for fires, tracking airplanes or other moving objects, identification of missing or defective parts on production lines, and video recording of automobile crash tests.

Williams, Glenn L.↗