Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coherent errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Advances in the electron diffraction characterization of atomic clusters and nanoparticles

Nanoparticles and metallic clusters continue to make a remarkable impact on novel and emerging technologies. In recent years, there have been impressive advances in the controlled synthesis of clusters and their advanced characterization. One of the most common ways to determine the structures of nanoparticles and clusters is by means of X-ray diffraction methods. However, this requires the clusters to crystallize in a similar way to those used in protein studies, which is not possible in many cases. Novel methods based on electron diffraction have been used to efficiently study individual nanoparticles and clusters and these can overcome the obstacles commonly encountered during X-ray diffraction methods without the need for large crystals. These novel methodologies have improved with advances in electron microscopy instrumentation and electron detection. Here, we review advanced methodologies for characterizing metallic nanoparticles and clusters using a variety of electron diffraction procedures. These include selected area electron diffraction, nanobeam diffraction, coherent electron diffraction, precession electron diffraction, scanning transmission electron microcopy diffraction, and high throughput data analytics, which leverage deep learning to reduce the propensity for data errors and translate nanometer and atomic scale measurements into material data.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Faster Randomized Dynamical Decoupling

We present a randomized dynamical decoupling (DD) protocol that can substantially improve the performance of any given deterministic DD scheme for suppressing coherent noise by using no more than two additional pulses. Our construction is implemented by probabilistically applying sequences of pulses, which, when combined, effectively eliminate the error terms that scale linearly with the system-environment coupling strength. As a result, we show that a randomized protocol using a few pulses can outperform deterministic DD protocols that require considerably more pulses. Furthermore, we prove that the randomized protocol provides an improvement compared to deterministic DD sequences that aim to reduce the error in the system’s Hilbert space, such as Uhrig DD, which had been previously regarded to be optimal. To rigorously evaluate the performance, we introduce new analytical methods suitable for analyzing higher-order DD protocols that might be of independent interest. Here, we also present numerical simulations confirming the significant advantage of using randomized protocols compared to widely used deterministic protocols.

Quantum algorithms & computation↗

Reexamining classical and quantum models for the D-Wave One processor: The role of excited states and ground state degeneracy

We revisit the evidence for quantum annealing in the D-Wave One device (DW1) based on the study of random Ising instances. Using the probability distributions of finding the ground states of such instances, previous work found agreement with both simulated quantum annealing (SQA) and a classical rotor model. Thus the DW1 ground state success probabilities are consistent with both models, and a different measure is needed to distinguish the data and the models. Here in this paper we consider measures that account for ground state degeneracy and the distributions of excited states, and present evidence that for these new measures neither SQA nor the classical rotor model correlate perfectly with the DW1 experiments. We thus provide evidence that SQA and the classical rotor model, both of which are classically efficient algorithms, do not satisfactorily explain all the DW1 data. A complete model for the DW1 remains an open problem. Using the same criteria we find that, on the other hand, SQA and the classical rotor model correlate closely with each other. To explain this we show that the rotor model can be derived as the semiclassical limit of the spin-coherent states path integral. We also find differences in which set of ground states is found by each method, though this feature is sensitive to calibration errors of the DW1 device and to simulation parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-C-18A-04: 3D Markerless Registration of Lung Based On Coherent Point Drift: Application in Image Guided Radiotherapy

Purpose: This study evaluated a new probabilistic non-rigid registration method called coherent point drift for real time 3D markerless registration of the lung motion during radiotherapy. Method: 4DCT image datasets Dir-lab (www.dir-lab.com) have been used for creating 3D boundary element model of the lungs. For the first step, the 3D surface of the lungs in respiration phases T0 and T50 were segmented and divided into a finite number of linear triangular elements. Each triangle is a two dimensional object which has three vertices (each vertex has three degree of freedom). One of the main features of the lungs motion is velocity coherence so the vertices that creating the mesh of the lungs should also have features and degree of freedom of lung structure. This means that the vertices close to each other tend to move coherently. In the next step, we implemented a probabilistic non-rigid registration method called coherent point drift to calculate nonlinear displacement of vertices between different expiratory phases. Results: The method has been applied to images of 10-patients in Dir-lab dataset. The normal distribution of vertices to the origin for each expiratory stage were calculated. The results shows that the maximum error of registration between different expiratory phases is less than 0.4 mm (0.38 SI, 0.33 mm AP, 0.29 mm RL direction). This method is a reliable method for calculating the vector of displacement, and the degrees of freedom (DOFs) of lung structure in radiotherapy. Conclusions: We evaluated a new 3D registration method for distribution set of vertices inside lungs mesh. In this technique, lungs motion considering velocity coherence are inserted as a penalty in regularization function. The results indicate that high registration accuracy is achievable with CPD. This method is helpful for calculating of displacement vector and analyzing possible physiological and anatomical changes during treatment.

60 APPLIED LIFE SCIENCES↗

Quantum computer-enabled receivers for optical communication

Abstract Optical communication is the standard for high-bandwidth information transfer in today’s digital age. The increasing demand for bandwidth has led to the maturation of coherent transceivers that use phase- and amplitude-modulated optical signals to encode more bits of information per transmitted pulse. Such encoding schemes achieve higher information density, but also require more complicated receivers to discriminate the signaling states. In fact, achieving the ultimate limit of optical communication capacity, especially in the low light regime, requires coherent joint detection of multiple pulses. Despite their superiority, such joint detection receivers are not in widespread use because of the difficulty of constructing them in the optical domain. In this work we describe how optomechanical transduction of phase information from coherent optical pulses to superconducting qubit states followed by the execution of trained short-depth variational quantum circuits can perform joint detection of communication codewords with error probabilities that surpass all classical, individual pulse detection receivers. Importantly, we utilize a model of optomechanical transduction that captures non-idealities such as thermal noise and loss in order to understand the transduction performance necessary to achieve a quantum advantage with such a scheme. We also execute the trained variational circuits on an IBM-Q device with the modeled transduced states as input to demonstrate that a quantum advantage is possible even with current levels of quantum computing hardware noise.

97 MATHEMATICS AND COMPUTING↗

Dual-wavelength vertical scanning low-coherence interferometric microscope

White-light interferometry has turned into a standard tool in the field of high-accuracy topography measurements. Nevertheless, surfaces with relatively large local surface tilts or height steps often give rise to systematic measuring errors. The reasons are diffraction and dispersion effects, which cause deviations between height values obtained from the envelope maximum of the white-light interference signal and those obtained from the signal's phase. In certain cases this may result in ghost steps appearing in the measured topography. To identify and eliminate these ghost steps we use a second LED emitting light at a different mean wavelength. This now allows the measurement of curved or structured specular surfaces with high resolution, which up to now was restricted by the mentioned effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent X-ray Diffraction Imaging of Zeolite Microcrystals

We measured coherent x-ray diffraction (CXD), an emerging technique to obtain three-dimensional internal and external images of crystals, on ZSM-5 zeolite microcrystals to get internal density distribution and to map deformation field of strain. The experiments were performed at the beamline 34-ID-C in Advanced Photon Source at Argonne National Laboratory in the US. The CXD patterns of ZSM-5 zeolite microcrystals with sizes of 2 {mu}m by monochromatic coherent x-rays with energy of 9 keV were obtained under continuously surrounding and Bragg conditions as a function of temperature. The oversampled diffraction patterns are inverted to obtain three-dimensional images of the shapes and internal strain fields of zeolite microcrystals using phase retrieval algorithms of error reduction and a hybrid input-output method. The internal density and strain distribution as a function of temperature are discussed.

36 MATERIALS SCIENCE↗

Pressure-Driven Fiber-Optic Sensor for Online Corrosion Monitoring

For many industrial applications, corrosion is a life-limiting phenomenon and therefore requires careful consideration and rigorous experimental testing before structural materials can be reliably deployed, particularly in harsh chemical environments. The traditional approach to measuring corrosion requires exposing many samples to the intended environment and then extracting them individually at discrete intervals for postexposure characterization. This approach does not provide a high degree of temporal resolution, nor does it provide any real-time information regarding dynamic changes in corrosion rates. Additionally, developing an online corrosion monitor capable of surviving harsh chemical environments could provide valuable information regarding the structural health of components and changing process conditions that could accelerate corrosion. To this end, a corrosion sensor was developed based on a pressure-driven Fabry-Pérot cavity (FPC). This sensor uses a pressure control system to internally pressurize the FPC formed between the sensor’s housing and a metal-embedded singlemode optical fiber. Simultaneous measurement of the change in FPC length using low-coherence interferometry and the applied pressure enables the calculation of the relative changes in the sensor’s diaphragm thickness due to corrosion on its outer surface. Measurements were made in situ while actively corroding the sensor and were validated against surveillance specimens that were corroded simultaneously. The uncertainties in the measured corrosion were analyzed using error propagation of the uncertainties in the measured pressures and displacements and were found to be <1% of the initial diaphragm thickness.

42 ENGINEERING↗

Quantum displacement receiver for M-ary phase-shift-keyed coherent states

We propose quantum receivers for 3- and 4-ary phase-shift-keyed (PSK) coherent state signals to overcome the standard quantum limit (SQL). Our receiver, consisting of a displacement operation and on-off detectors with or without feedforward, provides an error probability performance beyond the SQL. We show feedforward operations can tolerate the requirement for the detector specifications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Role of intensity fluctuations in quantum cryptography with coherent states

A new type of attack in quantum cryptography with coherent states is considered. This attack calls for only a possibility of changing (within some limits) the intensity of the states reaching a receiver. The critical quantum bit error rate (QBER) of the B92 protocol with a strong reference state is calculated for different limitations on intensity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamics of SU(1,1) coherent states for the damped harmonic oscillator

Gerry, Ma, and Vrscay [Phys. Rev. A 39, 668 (1989)] studied the time evolution of SU(1,1) coherent states for the damped harmonic oscillator by introducing the Kanai-Caldirola Hamiltonian. The purposes of this Brief Report are to demonstrate that there are somewhat serious errors on their results and to correct them. Most of the figures given in their work are reproduced with correction in order to facilitate our explanation of results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual-pump Coherent anti-Stokes Raman scattering measurements in H 2 /CH 4 Counterflow Flames

Temperature and major species concentration measurements are reported in a Williams Seshadri counterflow burner using dual-pump coherent anti-Stokes Raman scattering (DPCARS). Hencken burner H2/Air flames with equivalence ratio of 0.8-1.4 were used to characterize the accuracy of the system. The mean errors for temperature, XH2/XN2 mole fraction ratio, and XO2/XN2 mole fraction ratio are 1.0%, 14.7%, and 5.5%, respectively. The counterflow burner uses a CH4, H2, and N2 mixture as fuel and synthetic air as oxidizer. Measurements were performed along the counterflow burner central axis for two different fuel compositions: 4% H2/86% CH4/10% N2 and 87%H2/3% CH4/10% N2. The measured temperature and species mole fractions agree well with the 1-D opposed-flow diffusion flame simulation. One observation is that the fuel inlet temperature is higher than 300 K, which suggests the possibility of the stagnation plane residing closer to the fuel side. Lastly, these measurements provide valuable data for testing and validation of advanced 2-D flame models.

Murdock, Benjamin K.↗

Building a quantum computing architecture using 3D superconducting cavities

Quantum computers promise advantages over classical machines for solving certain complex problems, but building processors that truly deliver this advantage remains a central challenge, particularly due to limited coherence times. Three-dimensional superconducting radio-frequency (SRF) cavities offer an attractive platform due to their exceptionally long lifetimes. However, since these harmonic systems require nonlinear elements, such as transmons, for control, additional losses are often introduced. In this talk, I will present a multimode quantum system based on an elliptical SRF cavity hosting two cavity modes weakly coupled to an ancillary transmon circuit. This architecture is carefully engineered to preserve coherence while enabling efficient control. By optimizing the design to mitigate transmon-induced decoherence, we realize single-photon lifetimes of 20.6 ms and 15.6 ms in the two modes, with pure dephasing times exceeding 40 ms. Using sideband interactions and error-resilient protocols, such as measurement-based correction and post-selection, we demonstrate high-fidelity state control, including preparation of Fock states up to N=20 with fidelities above 95% (to our knowledge, the highest reported to date), as well as high-fidelity two-mode entanglement. These results highlight 3D SRF cavities as a robust foundation for qudit-based quantum information processing, harnessing the large Hilbert space of cavity modes. I will conclude by outlining strategies to further enhance coherence in both cavities and ancilla qubits, and discuss pathways toward scaling this architecture into a larger quantum computing platform.

Roy, Tanay [Fermilab]↗

Dielectric-barrier-discharge plasma-assisted hydrogen diffusion flame. Part 1: Temperature, oxygen, and fuel measurements by one-dimensional fs/ps rotational CARS imaging

One-dimensional hybrid fs/ps CARS imaging provides single-laser-shot measurements of temperature, oxygen, and hydrogen in a plasma-assisted hydrogen diffusion flame. The coaxial dielectric-barrier-discharge burner collapses the Re ~50 hydrogen diffusion flame to within ~5 mm of the burner surface at an applied AC potential of 8.75 kV at 18 kHz, coinciding nicely with the full spatial extent of the 1D CARS measurements. Translating the burner through the measurement volume allowed for measurements at numerous radial locations in increments of 1 mm with a resolution of 140 µm × 30 µm × 600 µm, sufficient to resolve spatial gradients in this unsteady flame. Longer probe delays, required for improved dynamic range in regions of high temperature fluctuations, proved difficult to model as a result of a nontrivial decay in the O 2 Raman coherence arising from complexities associated with the triplet ground electronic state of the O 2 molecule. Oxygen linewidths were treated empirically using the observed O 2 coherence decay in spectra acquired from the product gases of lean, near-adiabatic H 2 /air flames stabilized on a Hencken flat-flame burner. While still leading to errors up to 10% at worst, the empirically determined Raman linewidth factors eliminated any systematic error in the O 2 /N 2 measurements with probe delay. Temperature measurements in the Hencken Burner flames proved to be insensitive to probe pulse delay, providing robust thermometry. Here, demonstration of this technique in both the canonical Hencken burner flames and a new DBD burner validates its effectiveness in producing multiple spatially resolved measurements in combustion environments. Measurements in the DBD burner revealed an unsteady, counterflow flattened flame structure near the fuel orifice which became unsteady as the reaction zone curves towards the surface for larger radial positions. Lastly, fluctuations in the fuel concentration were largest at the source, as the large, plasma-generated, unsteady external toroidal vortex that dominates the transport in this flame provides enhanced ventilation of the flame surface in close proximity to the fuel tube.

42 ENGINEERING↗

Advanced X-ray Optics Metrology for Nanofocusing and Coherence Preservation

What is the point of developing new high-brightness light sources if beamline optics won't be available to realize the goals of nano-focusing and coherence preservation? That was one of the central questions raised during a workshop at the 2007 Advanced Light Source Users Meeting. Titled, 'Advanced X-Ray Optics Metrology for Nano-focusing and Coherence Preservation', the workshop was organized by Kenneth Goldberg and Valeriy Yashchuk (both of Lawrence Berkeley National Laboratory, LBNL), and it brought together industry representatives and researchers from Japan, Europe, and the US to discuss the state of the art and to outline the optics requirements of new light sources. Many of the presentations are viewable on the workshop website http://goldberg.lbl.gov/MetrologyWorkshop07/. Many speakers shared the same view of one of the most significant challenges facing the development of new high-brightness third and fourth generation x-ray, soft x-ray, and EUV light sources: these sources place extremely high demands on the surface quality of beamline optics. In many cases, the 1-2-nm surface error specs that define the outer bounds of 'diffraction-limited' quality are beyond the reach of leading facilities and optics vendors. To focus light to 50-nm focal spots, or smaller, from reflective optics and to preserve the high coherent flux that new sources make possible, the optical surface quality and alignment tolerances must be measured in nano-meters and nano-radians. Without a significant, well-supported research effort, including the development of new metrology techniques for use both on and off the beamline, these goals will likely not be met. The scant attention this issue has garnered is evident in the stretched budgets and limited manpower currently dedicated to metrology. With many of the world's leading groups represented at the workshop, it became clear that Japan and Europe are several steps ahead of the US in this critical area. But the situation isn't all dire: several leading groups are blazing a trail forward, and the recognition of this issue is increasing. The workshop featured eleven invited talks whose presenters came from Japan, Europe, and the US.

36 MATERIALS SCIENCE↗

{rho}{sup 0} photoproduction in ultraperipheral relativistic heavy ion collisions at {radical}(s{sub NN})=200 GeV

Photoproduction reactions occur when the electromagnetic field of a relativistic heavy ion interacts with another heavy ion. The STAR Collaboration presents a measurement of {rho}{sup 0} and direct {pi}{sup +}{pi}{sup -} photoproduction in ultraperipheral relativistic heavy ion collisions at {radical}(s{sub NN})=200 GeV. We observe both exclusive photoproduction and photoproduction accompanied by mutual Coulomb excitation. We find a coherent cross section of {sigma}(AuAu{yields}Au*Au*{rho}{sup 0})=530{+-}19(stat.){+-}57(syst.) mb, in accord with theoretical calculations based on a Glauber approach, but considerably below the predictions of a color dipole model. The {rho}{sup 0} transverse momentum spectrum (p{sub T}{sup 2}) is fit by a double exponential curve including both coherent and incoherent coupling to the target nucleus; we find {sigma}{sub inc}/{sigma}{sub coh}=0.29{+-}0.03(stat.){+-}0.08(syst.). The ratio of direct {pi}{sup +}{pi}{sup -} to {rho}{sup 0} production is comparable to that observed in {gamma}p collisions at HERA and appears to be independent of photon energy. Finally, the measured {rho}{sup 0} spin helicity matrix elements agree within errors with the expected s-channel helicity conservation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark oxygen-oxygen pair-distribution function of ambient water from x-ray diffraction measurements with a wide Q-range

Four recent x-ray diffraction measurements of ambient liquid water are reviewed here. Each of these measurements represents a significant development of the x-ray diffraction technique applied to the study of liquid water. Sources of uncertainty from statistical noise, Q-range, Compton scattering, and self-scattering are discussed. The oxygen-hydrogen contribution to the measured x-ray scattering pattern was subtracted using literature data to yield an experimental determination, with error bars, of the oxygen-oxygen pair-distribution function, g{sub OO}(r), which essentially describes the distribution of molecular centers. The extended Q-range and low statistical noise of these measurements has significantly reduced truncation effects and related errors in the g{sub OO}(r) functions obtained. From these measurements and error analysis, the position and height of the nearest neighbor maximum in g{sub OO}(r) were found to be 2.80(1) A and 2.57(5) respectively. Numerical data for the coherent differential x-ray scattering cross-section I{sub X}(Q), the oxygen-oxygen structure factor S{sub OO}(Q), and the derived g{sub OO}(r) are provided as benchmarks for calibrating force-fields for water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast Preparation and Detection of a Rydberg Qubit Using Atomic Ensembles

Here, we demonstrate a new approach for fast preparation, manipulation, and collective readout of an atomic Rydberg-state qubit. By making use of Rydberg blockade inside a small atomic ensemble, we prepare a single qubit within 3 μs with a success probability of $F_p$ = 0.93 ± 0.02, rotate it, and read out its state in 6 μs with a single-shot fidelity of $F_d$ = 0.92 ± 0.04. The ensemble-assisted detection is 10 3 times faster than imaging of a single atom with the same optical resolution, and enables fast repeated nondestructive measurement. We observe qubit coherence times of 15 μs, much longer than the π rotation time of 90 ns. Potential applications ranging from faster quantum information processing in atom arrays to efficient implementation of quantum error correction are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗