Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coherent errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Ultracoherent SRF Cavity-Based Multi-Qudit Platform with Error-Resilient Control

Superconducting radio-frequency (SRF) cavities offer a promising platform for quantum computing due to their long coherence times, yet integrating nonlinear elements like transmons for control often introduces additional loss. We report a multimode quantum system based on a 2-cell elliptical shaped SRF cavity, comprising two cavity modes weakly coupled to an ancillary transmon circuit, designed to preserve coherence while enabling efficient control of the cavity modes. We mitigate the detrimental effects of the transmon decoherence through careful design optimization that reduces transmon-cavity couplings and participation in the dielectric substrate and lossy interfaces, to achieve single-photon lifetimes of 20.6\,ms and 15.6\,ms for the two modes, and a pure dephasing time exceeding 40\,ms. This marks an order-of-magnitude improvement over prior 3D multimode memories. Leveraging sideband interactions and novel error-resilient protocols, including measurement-based correction and post-selection, we achieve high-fidelity control over quantum states. This enables the preparation of Fock states up to $N = 20$ with fidelities exceeding 95\%, the highest reported to date to the authors' knowledge, as well as two-mode entanglement with an estimated coherence-limited fidelities of 99.9\% after post-selection. These results establish our platform as a robust foundation for quantum information processing, allowing for future extensions to high-dimensional qudit encodings.

Kim, T. [Northwestern U.]↗

Ultracoherent superconducting cavity-based multiqudit platform with error-resilient control

Superconducting radio-frequency (SRF) cavities offer a promising platform for quantum computing due to their long coherence times, yet integrating nonlinear elements like transmons for control often introduces additional loss. We report a multimode quantum system based on a 2-cell elliptical-shaped SRF cavity, comprising two cavity modes weakly coupled to an ancillary transmon circuit, designed to preserve coherence while enabling efficient control of the cavity modes. We mitigate the detrimental effects of the transmon decoherence through careful design optimization that reduces transmon-cavity couplings and participation in the dielectric substrate and lossy interfaces, to achieve single-photon lifetimes of 20.6 ms and 15.6 ms for the two modes, and a pure dephasing time exceeding 40 ms. This marks an order-of-magnitude improvement over prior 3D multimode memories. Leveraging sideband interactions and novel error-resilient protocols, including measurement-based correction and post-selection, we achieve high-fidelity control over quantum states. This enables the preparation of Fock states up to N = 20 with fidelities exceeding 95%, the highest reported to date to the authors' knowledge, as well as two-mode entanglement with an estimated coherence-limited fidelities of 99.9% after post-selection. These results establish our platform as a robust foundation for quantum information processing, allowing for future extensions to high-dimensional qudit encodings.

Lu, Yao [Fermilab] (ORCID:000000020413698X)↗

Ultracoherent superconducting cavity-based multiqudit platform with error-resilient control

Superconducting radio-frequency (SRF) cavities offer a promising platform for quantum computing due to their long coherence times, yet integrating nonlinear elements like transmons for control often introduces additional loss. We report a multimode quantum system based on a 2-cell elliptical-shaped SRF cavity, comprising two cavity modes weakly coupled to an ancillary transmon circuit, designed to preserve coherence while enabling efficient control of the cavity modes. We mitigate the detrimental effects of the transmon decoherence through careful design optimization that reduces transmon-cavity couplings and participation in the dielectric substrate and lossy interfaces, to achieve single-photon lifetimes of 20.6 ms and 15.6 ms for the two modes, and a pure dephasing time exceeding 40 ms. This marks an order-of-magnitude improvement over prior 3D multimode memories. Leveraging sideband interactions and novel error-resilient protocols, including measurement-based correction and post-selection, we achieve high-fidelity control over quantum states. This enables the preparation of Fock states up to N = 20 with fidelities exceeding 95%, the highest reported to date to the authors' knowledge, as well as two-mode entanglement with an estimated coherence-limited fidelities of 99.9% after post-selection. These results establish our platform as a robust foundation for quantum information processing, allowing for future extensions to high-dimensional qudit encodings.

Lu, Yao [Fermilab] (ORCID:000000020413698X)↗

Ultracoherent superconducting cavity-based multiqudit platform with error-resilient control

Superconducting radio-frequency (SRF) cavities offer a promising platform for quantum computing due to their long coherence times, yet integrating nonlinear elements like transmons for control often introduces additional loss. We report a multimode quantum system based on a 2-cell elliptical shaped SRF cavity, comprising two cavity modes weakly coupled to an ancillary transmon circuit, designed to preserve coherence while enabling efficient control of the cavity modes. We mitigate the detrimental effects of the transmon decoherence through careful design optimization that reduces transmon-cavity couplings and participation in the dielectric substrate and lossy interfaces, to achieve single-photon lifetimes of 20.6 ms and 15.6 ms for the two modes, and a pure dephasing time exceeding 40 ms. This marks an order-of-magnitude improvement over prior 3D multimode memories. Leveraging sideband interactions and novel error-resilient protocols, including measurement-based correction and post-selection, we achieve high-fidelity control over quantum states. This enables the preparation of Fock states up to $N = 20$ with fidelities exceeding 95%, the highest reported to date to the authors' knowledge, as well as two-mode entanglement with an estimated coherence-limited fidelities of 99.9% after post-selection. These results establish our platform as a robust foundation for quantum information processing, allowing for future extensions to high-dimensional qudit encodings.

Kim, Taeyoon [Fermilab; Northwestern U.]↗

Orbit-determination performance of Doppler data for interplanetary cruise trajectories. Part 2: 8.4-GHz performance and data-weighting strategies

A consider error covariance analysis was performed in order to investigate the orbit-determination performance attainable using two-way (coherent) 8.4-GHz (X-band) Doppler data for two segments of the planned Mars Observer trajectory. The analysis includes the effects of the current level of calibration errors in tropospheric delay, ionospheric delay, and station locations, with particular emphasis placed on assessing the performance of several candidate elevation-dependent data-weighting functions. One weighting function was found that yields good performance for a variety of tracking geometries. This weighting function is simple and robust; it reduces the danger of error that might exist if an analyst had to select one of several different weighting functions that are highly sensitive to the exact choice of parameters and to the tracking geometry. Orbit-determination accuracy improvements that may be obtained through the use of calibration data derived from Global Positioning System (GPS) satellites also were investigated, and can be as much as a factor of three in some components of the spacecraft state vector. Assuming that both station-location errors and troposphere calibration errors are reduced simultaneously, the recommended data-weighting function need not be changed when GPS calibrations are incorporated in the orbit-determination process.

Ulvestad, J. S.↗

Hybrid quantum-classical hierarchy for mitigation of decoherence and determination of excited states

Using quantum devices supported by classical computational resources is a promising approach to quantum-enabled computation. One powerful example of such a hybrid quantum-classical approach optimized for classically intractable eigenvalue problems is the variational quantum eigensolver, built to utilize quantum resources for the solution of eigenvalue problems and optimizations with minimal coherence time requirements by leveraging classical computational resources. These algorithms have been placed as leaders among the candidates for the first to achieve supremacy over classical computation. Here, we provide evidence for the conjecture that variational approaches can automatically suppress even nonsystematic decoherence errors by introducing an exactly solvable channel model of variational state preparation. Moreover, we develop a more general hierarchy of measurement and classical computation that allows one to obtain increasingly accurate solutions by leveraging additional measurements and classical resources. In conclusion, we demonstrate numerically on a sample electronic system that this method both allows for the accurate determination of excited electronic states as well as reduces the impact of decoherence, without using any additional quantum coherence time or formal error-correction codes.

McClean, Jarrod R.↗

Chlorophyll-a Algorithms for Oligotrophic Oceans: A Novel Approach Based on Three-Band Reflectance Difference

A new empirical algorithm is proposed to estimate surface chlorophyll-a concentrations (Chl) in the global ocean for Chl less than or equal to 0.25 milligrams per cubic meters (approximately 77% of the global ocean area). The algorithm is based on a color index (CI), defined as the difference between remote sensing reflectance (R(sub rs), sr(sup -1) in the green and a reference formed linearly between R(sub rs) in the blue and red. For low Chl waters, in situ data showed a tighter (and therefore better) relationship between CI and Chl than between traditional band-ratios and Chl, which was further validated using global data collected concurrently by ship-borne and SeaWiFS satellite instruments. Model simulations showed that for low Chl waters, compared with the band-ratio algorithm, the CI-based algorithm (CIA) was more tolerant to changes in chlorophyll-specific backscattering coefficient, and performed similarly for different relative contributions of non-phytoplankton absorption. Simulations using existing atmospheric correction approaches further demonstrated that the CIA was much less sensitive than band-ratio algorithms to various errors induced by instrument noise and imperfect atmospheric correction (including sun glint and whitecap corrections). Image and time-series analyses of SeaWiFS and MODIS/Aqua data also showed improved performance in terms of reduced image noise, more coherent spatial and temporal patterns, and consistency between the two sensors. The reduction in noise and other errors is particularly useful to improve the detection of various ocean features such as eddies. Preliminary tests over MERIS and CZCS data indicate that the new approach should be generally applicable to all existing and future ocean color instruments.

Hu, Chuanmin↗

A Multi-Branch Decoder Network Approach to Adaptive Temporal Data Selection and Reconstruction for Big Scientific Simulation Data

A key challenge in scientific simulation is that the simulation outputs often require intensive I/O and storage space to store the results for effective post hoc analysis. This article focuses on a quality-aware adaptive temporal data selection and reconstruction problem where the goal is to adaptively select simulation data samples at certain key timesteps in situ and reconstruct the discarded samples with quality assurance during post hoc analysis. This problem is motivated by the limitation of current solutions that a significant amount of simulation data samples are either discarded or aggregated during the sampling process, leading to inaccurate modeling of the simulated phenomena. Two unique challenges exist: 1) the sampling decisions have to be made in situ and adapted to the dynamics of the complex scientific simulation data; 2) the reconstruction error must be strictly bounded to meet the application requirement. To address the above challenges, we develop DeepSample , an error-controlled convolutional neural network framework, that jointly integrates a set of coherent multi-branch deep decoders to effectively reconstruct the simulation data with rigorous quality assurance. The results on two real-world scientific simulation applications show that DeepSample significantly outperforms other state-of-the-art methods on both sampling efficiency and reconstructed simulation data quality.

Zhang, Yang↗

DSP-based non-coherent dual detector demodulator for land mobile radio channels

This paper outlines the development of a digital demodulator suitable for the non-coherent detection of various modulation formats including: Phase Shift Keying (PSK), Continuous Phase Frequency Shift Keying (CPFSK) and Frequency Modulation (FM). The demodulator design concept has been derived with a view towards a single integrated circuit (IC) implementation. Two detectors, one non-coherent and one differentially coherent, operate concurrently, providing data detection and automatic frequency control (AFC). Bit error rate results are provided which illustrate the receiver performance in white Gaussian noise.

Saulnier, Gary J.↗

Interference by rain scatter

The data from Japan and the U.S. (the Virginia Precipitation Scatter Experiment) show excellent agreement between the two-component rain scatter model predictions and bistatic scatter measurements. In employing the model, all the scattering geometries should be classified as backscattering as defined by Crane (1974). The forward scatter model should only be used for great circle paths with both antennas pointed at the horizon and at each other in a typical troposcatter communication system geometry. The forward scatter model can also be used for main-lobe, side-lobe coupling when one antenna is pointed toward the other along the great circle path. The forward scatter observations made over the Prospect Hill - Mt Tug path show that the two-component model is incomplete. Much stronger signals were observed at Ku-band than expected based on simultaneous C-band measurements. The discrepancies may be due to: (1) scattering by ice/snow at height (posssible in April) at the 1 km height of the scattering volume), (2) the coherent effects of turbulent fluctuations in the hydrometeor number densities and (3) errors in the modeling of the statistical relationship between attenuation along the path and scattering in the common volume.

Crane, Robert K.↗

Quadratic squeezing: An overview

The amplitude of the electric field of a mode of the electromagnetic field is not a fixed quantity: there are always quantum mechanical fluctuations. The amplitude, having both a magnitude and a phase, is a complex number and is described by the mode annihilation operator a. It is also possible to characterize the amplitude by its real and imaginary parts which correspond to the Hermitian and anti-Hermitian parts of a, X sub 1 = 1/2(a(sup +) + a) and X sub 2 = i/2(a(sup +) - a), respectively. These operators do not commute and, as a result, obey the uncertainty relation (h = 1) delta X sub 1(delta X sub 2) greater than or = 1/4. From this relation we see that the amplitude fluctuates within an 'error box' in the complex plane whose area is at least 1/4. Coherent states, among them the vacuum state, are minimum uncertainty states with delta X sub 1 = delta X sub 2 = 1/2. A squeezed state, squeezed in the X sub 1 direction, has the property that delta X sub 1 is less than 1/2. A squeezed state need not be a minimum uncertainty state, but those that are can be obtained by applying the squeeze operator.

Hillery, M.↗

Emulating climate extreme indices

We use simple pattern scaling and time-shift to emulate changes in a set of climate extreme indices under future scenarios, and evaluate the emulators' accuracy. We propose a metric for the error in emulation in the context of initial condition ensembles, to specifically characterize the role of internal variability in the emulation performance. Our metric separates systematic emulation errors from unavoidable discrepancies between emulated and target values due to internal variability. We compute the metricis at grid-point scale, and we show geographically resolved results, or aggregate them at global scale. We demonstrate the use of our error metric in the emulation of a suite of temperature and precipitation extreme indices. We test and compare simple pattern scaling and time-shift using a range of trajectories spanning targets inspired by the Paris agreement -- warming to 1.5C and 2.0C from the pre-industrial baseline -- and two of the longer-established trajectories, RCP4.5 and RCP8.5. With this suite of scenarios we can test the effects on the performance of the size of the temperature gap between emulation origin and target. We find that for most indices emulation the dominant source of discrepancy is internal variability. For at least one index, however, counting exceedances of a high temperature threshold, significant portions of the globally aggregated discrepancy and its regional pattern originate from the systematic emulation error. This error exceeds internal variability of both the target and the emulated quantities in large coherent regions at low latitudes, and the explanation can be found in the differential behavior of temperature distributions across latitudes. The metric also highlights a fundamental difference in the two methods related to the simulation of internal variability, which is dampened significantly by simple pattern scaling. This aspect is of consequence when using these methods for specific applications, where preserving variability for uncertainty quantification is deemed important. With this study we offer our metric as a diagnostic tool, facilitating the formulation of scientific hypotheses on the reasons for the error. In the meantime, we show that for many impact relevant indices by now traditional emulation techniques can be accurate within the variations unavoidably introduced by internal variability, establishing the fundamental condition for using their emulation in impact modeling.

54 ENVIRONMENTAL SCIENCES↗

ALMA Band-to-band Phase Referencing: Imaging Capabilities on Long Baselines and High Frequencies

High-frequency long-baseline experiments with the Atacama Large Millimeter/submillimeter Array were organized to test the high angular resolution imaging capabilities in the submillimeter wave regime using baselines up to 16 km. Four experiments were conducted, two Band 7 (289 GHz) and two Band 8 (405 GHz) observations. Phase correction using band-to-band (B2B) phase referencing was used with a phase calibrator only [[Formula]] away observed in Band 3 (96 GHz) and Band 4 (135 GHz), respectively. In Band 8, we achieved the highest resolution of 14 × 11 mas. We compared the synthesis images of the target quasar using 20 and 60 s switching cycle times in the phase referencing. In Band 7, the atmosphere had good stability in phase rms (<0.5 rad over 2 minutes), and there was little difference in image coherence between the 20 and 60 s switching cycle times. One Band 8 experiment was conducted under a worse phase rms condition (>1 rad over 2 minutes), which led to a significantly reduced coherence when using the 60 s switching cycle time. One of our four experiments indicates that the residual phase rms error after phase referencing can be reduced to 0.16 rad at 289 GHz in using the 20 s switching cycle time. Such conditions would meet the phase correction requirement of image coherence of >70% in Band 10, assuming a similar phase calibrator separation angle, emphasizing the need for such B2B phase referencing observing at high frequencies.

79 ASTRONOMY AND ASTROPHYSICS↗

Tracking Virtual Trajectories

Current models of smooth pursuit eye movements assume that it is largely driven by retinal image motion. We tested this hypothesis by measuring pursuit of elliptical motion (3.2s, 0.9 Hz, 1.4 deg x 1.6 deg, 4 randomly interleaved phases) of either a small spot ("real" motion) or of a line-figure diamond viewed through apertures such that only the motion of four isolated oblique line segments was visible ("virtual" motion). Each segment moved sinusoidally along a linear trajectory yet subjects perceived a diamond moving along an elliptical path behind the aperture. We found, as expected, that real motion produced accurate tracking (N = 2) with mean gain (over horizontal and vertical) of 0.9, mean phase of -6 deg (lag), mean relative phase (H vs V) of 90 +/- 8 deg (RMS error). Virtual motion behind an X-shaped aperture (N= 4 with one naive) yielded a mean gain of 0.7, mean phase of -11 deg, mean relative phase of 87 +/- 15 deg. We also measured pursuit with the X-shaped aperture using a higher segment luminance which prevents the segments from being grouped into a coherently moving diamond while keeping the motion otherwise identical. In this incoherent case, the same four subjects no longer showed consistent elliptical tracking (RMS error in relative phase rose to 60 deg) suggesting that perceptual coherence is critical. Furthermore, to rule out tracking of the centroid, we also used vertical apertures so that all segment motion was vertical (N = 3). This stimulus still produced elliptical tracking (mean relative phase of 84 +/- 19 deg), albeit with a lower gain (0.6). These data show that humans can track moving objects reasonably accurately even when the trajectory can only be derived by spatial integration of motion signals. Models that merely seek to minimize retinal or local stimulus motion cannot explain these results.

Stone, Leland S.↗

Noise Reduction Potential of Phase Control for Distributed Propulsion Vehicles

Phase control is a noise reduction technique leveraging destructive interference of the coherent acoustic source field between a system of propellers rotating at equivalent rates. Carefully selecting the relative azimuthal blade positions (phase), the overall directivity of the blade passage frequency noise can be modified, potentially steering these tonal components away from sensitive areas. A modeling technique is described and validated using measurements of a dual-rotor system. The sensitivity of noise reduction through phase control is studied in a typical parameter space, i.e., dependence on rotation rate, number of propellers, spacing and layout, and rotation direction. Additionally, estimates of how realistic conditions, e.g., error in the phase controller, degrade potential benefits are described based on the generalized coherence of the system. From this, it is observed that the deviation from the nominal rotation rate should not exceed approximately 0.5% to achieve a 6 dB decrease at the blade passage frequency.

Kyle A Pascioni↗

Lefschetz thimble quantum Monte Carlo for spin systems

Monte Carlo simulations are useful tools for modeling quantum systems, but in some cases they suffer from a sign problem, leading to an exponential slow down in their convergence to a value. While solving the sign problem is generically NP hard, many techniques exist for mitigating the sign problem in specific cases; in particular, the technique of deforming the Monte Carlo simulation's plane of integration onto Lefschetz thimbles (complex hypersurfaces of stationary phase) has seen significant success in the context of quantum field theories. We extend this methodology to spin systems by utilizing spin coherent state path integrals to reexpress the spin system's partition function in terms of continuous variables. Using some toy systems, we demonstrate its effectiveness at lessening the sign problem in this setting, despite the fact that the initial mapping to spin coherent states introduces its own sign problem. The standard formulation of the spin coherent path integral is known to make use of uncontrolled approximations; despite this, for large spins they are typically considered to yield accurate results, so it is somewhat surprising that our results show significant systematic errors. Furthermore, possibly of independent interest, our use of Lefschetz thimbles to overcome the intrinsic sign problem in spin coherent state path integral Monte Carlo enables a novel numerical demonstration of a breakdown in the spin coherent path integral.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗