Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coherence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Evolution of ferroelastic domain walls during phase transitions in barium titanate nanoparticles

In this work, ferroelastic domain walls inside BaTiO 3 (BTO) tetragonal nanocrystals are distinguished by Bragg peak position and studied with Bragg coherent x-ray diffraction imaging (BCDI). Convergence-related features of the BCDI method for strongly phased objects are reported. A ferroelastic domain wall inside a BTO crystal has been tracked and imaged across the tetragonal-cubic phase transition and proves to be reversible. The linear relationship of relative displacement between two twin domains with temperature is measured and shows a different slope for heating and cooling, while the tetragonality reproduces well over temperature changes in both directions. An edge dislocation is also observed and found to annihilate when heating the crystal close to the phase transition temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advanced Laser-driven Plasma Accelerator Electron-beam Diagnostics with COTR Techniques

A significant advance in laser-driven plasma accelerator (LPA) electron-beam diagnostics has recently been demonstrated based on coherent optical transition radiation (COTR) imaging. We find COTR signal strengths from a microbunched subset of beam exiting the LPA to be several orders of magnitude higher than that of incoherent optical transition radiation (OTR). The transverse sizes are only a few microns as deduced from the point-spread-function-related lobe structure. In addition, the far-field COTR interferometric images obtained on the same shot provide beam-size limits plus divergence and pointing information at the sub-mrad level when compared to a modified analytical model. The integrated image intensities can be used to estimate the microbunching fraction and relatable to the LPA process. Initial results in a collaborative LPA experiment will be reported for electron beam energies of about 215 MeV. A revised configuration is proposed to record energy and ene rgy spread via COTR on the same shot with the interferometer.

43 PARTICLE ACCELERATORS↗

Lasing from Finite Plasmonic Nanoparticle Lattices

Small lasers can generate coherent light for integrated photonics, in-vivo cellular imaging, and solid-state lighting. Unlike conventional lasers, plasmonic lasers can generate coherent light at sub-wavelength scales, although cavity architectures based on metal films and semiconducting gain exhibit large radiative losses and lack directional emission. In contrast, two-dimensional (2D) metal nanoparticle arrays surrounded by organic dyes can support lasing with high directionality at room temperature. Yet, the relationship between the number of nanoparticles in a finite lattice and their lasing emission characteristics is unknown. Here we show that the number of units in 2D gold nanoparticle lattices is critical to generate robust cavity resonances and lasing emission. Narrower lattice plasmons associated with stronger electromagnetic near fields are observed as nanoparticle number increases. Experimentally, we demonstrate lasing from a 30x30 nanoparticle lattice. Semi-quantum modeling indicates lower lasing thresholds and faster population inversion dynamics with higher nanoparticle numbers. These findings indicate that finite lattices of nanoparticles integrated with gain can function as independent, coherent light sources for optical multiplexing and lab-on-a-chip applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Conditional guided generative diffusion for particle accelerator beam diagnostics

Abstract Advanced accelerator-based light sources such as free electron lasers (FEL) accelerate highly relativistic electron beams to generate incredibly short (10s of femtoseconds) coherent flashes of light for dynamic imaging, whose brightness exceeds that of traditional synchrotron-based light sources by orders of magnitude. FEL operation requires precise control of the shape and energy of the extremely short electron bunches whose characteristics directly translate into the properties of the produced light. Control of short intense beams is difficult due to beam characteristics drifting with time and complex collective effects such as space charge and coherent synchrotron radiation. Detailed diagnostics of beam properties are therefore essential for precise beam control. Such measurements typically rely on a destructive approach based on a combination of a transverse deflecting resonant cavity followed by a dipole magnet in order to measure a beam’s 2D time vs energy longitudinal phase-space distribution. In this paper, we develop a non-invasive virtual diagnostic of an electron beam’s longitudinal phase space at megapixel resolution (1024 × 1024) based on a generative conditional diffusion model. We demonstrate the model’s generative ability on experimental data from the European X-ray FEL.

43 PARTICLE ACCELERATORS↗

X-ray nano-holotomography reconstruction with simultaneous probe retrieval

In conventional tomographic reconstruction, the pre-processing step includes flat-field correction, where each sample projection on the detector is divided by a reference image taken without the sample. When using coherent X-rays as a probe, this approach overlooks the phase component of the illumination field (probe), leading to artifacts in phase-retrieved projection images, which are then propagated to the reconstructed 3D sample representation. The problem intensifies in nano-holotomography with focusing optics, which, due to various imperfections creates high-frequency components in the probe function. Here, we present a new iterative reconstruction scheme for holotomography, simultaneously retrieving the complex-valued probe function. Implemented on GPUs, this algorithm results in 3D reconstruction resolving twice thinner layers in a 3D ALD standard sample measured using nano-holotomography.

Nikitin, Viktor↗

Multidimensional Coherent Spectroscopy of van der Waals materials and heterostructures (Final Technical Report)

This project advanced multidimensional coherent spectroscopy (MDCS) and related spectroscopic-imaging methods as quantitative probes of many-body optical excitations in two-dimensional (2D) van der Waals (vdW) semiconductors and their heterostructures. Monolayer transition-metal dichalcogenides (TMDs) such as MoSe 2 and WSe 2 provide a uniquely strong platform for excitonic physics due to reduced dielectric screening, which enhances Coulomb interactions and makes higher-order correlated states (e.g., biexcitons and exciton–trion correlations) more prominent than in conventional bulk semiconductors. At the same time, the same sensitivity that enables strong interactions also increases susceptibility to spatial inhomogeneity—e.g., strain gradients, wrinkles, nanoscale disorder potentials, and charge puddling—which can broaden resonances, obscure interaction signatures, and complicate device-to-device reproducibility. The work reported here addressed this dual opportunity and challenge by: (i) developing and deploying coherent multidimensional methods (including double-quantum MDCS) capable of isolating interaction signals with reduced background, (ii) integrating electrostatic control to tune carrier populations and interaction strengths in situ, and (iii) introducing complementary spatially resolved photoluminescence (PL) techniques—hyperspectral PL imaging and polarization-/field-dependent PL lineshape analysis—to directly quantify disorder, strain, and localization that govern the coherent response.

36 MATERIALS SCIENCE↗

Mitigating Shear-dependent Object Detection Biases with Metacalibration

M ETACALIBRATION is a new technique for measuring weak gravitational lensing shear that is unbiased for isolated galaxy images. Here we test M ETACALIBRATION with overlapping, or "blended" galaxy images. Using standard M ETACALIBRATION , we find a few percent shear measurement bias for galaxy densities relevant for current surveys, and that this bias increases with increasing galaxy number density. We show that this bias is not due to blending itself, but rather to shear-dependent object detection. If object detection is shear-independent, no deblending of images is needed, in principle. We demonstrate that detection biases are accurately removed when including object detection in the M ETACALIBRATION process, a technique we call M ETADETECTION . This process involves applying an artificial shear to images of small regions of sky and performing detection on the sheared images, as well as measurements that are used to calculate a shear response. We demonstrate that the method can accurately recover weak shear signals even in highly blended scenes. In the M ETACALIBRATION process, the space between objects is sheared coherently, which does not perfectly match the real universe in which some, but not all, galaxy images are sheared coherently. We find that even for the worst case scenario, in which the space between objects is completely unsheared, the resulting shear bias is at most a few tenths of a percent for future surveys. We discuss additional technical challenges that must be met in order to implement M ETADETECTION for real surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Programmable low-coherence wavefronts for enhanced localization

Engineering the properties of electromagnetic wavefronts has become essential to imaging, wireless security, sensing, and wireless communication. In particular, wavefronts that exhibit low spatial coherence can enable sensing functionalities with high accuracy and low latency. The typical use of such wavefronts cannot take advantage of these possibilities, as they require the ability to dynamically reconfigure the wavefront in a controllable and repeatable fashion, over a broad spectral bandwidth. Here, we propose a new approach for generating broadband reconfigurable wavefronts which not only exhibit low spatial coherence at a particular frequency, but are also decorrelated with the wavefronts simultaneously generated at other frequencies. We demonstrate that this frequency-domain decorrelation is a key feature that, in combination with dynamic reconfigurability, enables localization measurements with an order-of-magnitude improvement in accuracy compared to the state of the art.

36 MATERIALS SCIENCE↗

MHD-blob correlations in NSTX

This paper describes a study of the cross-correlations between edge fluctuations as seen in the gas puff imaging (GPI) diagnostic and low frequency coherent magnetic fluctuations (“MHD”) in H-mode plasmas in NSTX. The main new result was that large blobs in the SOL were significantly correlated with MHD activity the 3-6 kHz range in 21 of the 223 shots examined. There were also many other shots in which fluctuations in the GPI signal level and its peak radius Rpeak were correlated with MHD activity, but without any significant correlation of the MHD with large blobs. The structure and motion of the MHD is compared with that of the correlated blobs, and some possible theoretical mechanisms for the MHD-blob correlation are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methods and algorithms for computer synthesis of holographic elements to obtain a complex impulse response of optical information processing systems based on modern spatial light modulators

The possibilities of designing optical devices for data processing and imaging based on the manipulation of coherent light beams by means of spatial light modulators (SLMs) are investigated. A review of commercially available SLMs is presented and the limitations of their complex modulation characteristics are analysed. The main problem of using present-day SLMs is the lack of the ability to modulate directly all states within a unit circle in the complex plane. In this regard, the characteristics of current methods for the synthesis of holographic elements are described that implement a given complex impulse response of the optical system and are optimal for using SLMs with purely amplitude, purely phase, and hybrid amplitude – phase modulation. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative phase measurements of human cell nuclei using X-ray ptychography

The human cell nucleus serves as an important organelle holding the genetic blueprint for life. In this work, X-ray ptychography was applied to assess the masses of human cell nuclei using its unique phase shift information. Measurements were carried out at the I13-1 beamline at the Diamond Light Source that has extremely large transverse coherence properties. Furthermore, the ptychographic diffractive imaging approach allowed imaging of large structures that gave quantitative measurements of the phase shift in 2D projections. In this paper a modified ptychography algorithm that improves the quality of the reconstruction for weak scattering samples is presented. The application of this approach to calculate the mass of several human nuclei is also demonstrated.

59 BASIC BIOLOGICAL SCIENCES↗

MHD-blob correlations in NSTX

This paper describes a study of the cross-correlations between edge fluctuations as seen in the gas puff imaging (GPI) diagnostic and low frequency coherent magnetic fluctuations (MHD) in H-mode plasmas in NSTX. The main new result was that large blobs in the SOL were significantly correlated with MHD activity the 3-6 kHz range in 21 of the 223 shots examined. There were also many other shots in which fluctuations in the GPI signal level and its peak radius Rpeak were correlated with MHD activity, but without any significant correlation of the MHD with large blobs. The structure and motion of the MHD is compared with that of the correlated blobs, and some possible theoretical mechanisms for the MHD-blob correlation are discussed.

blobs↗

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

Deep-learning-guided high-resolution subsurface reflectivity imaging with application to ground-penetrating radar data

Subsurface reflectivity imaging is one of the most important geophysical characterization methods for revealing subsurface structures. In many cases, accurate subsurface reflectivity imaging is challenging because of, for example, random or coherent noise in the data and sparse source-receiver observation geometry. Here, we develop a deep-learning-guided iterative imaging method to improve subsurface structure imaging. Specifically, we train a supervised neural network to infer a noise-free, high-resolution image from a noisy, low-resolution image and use this estimated image as guidance to regularize least-squares imaging. We develop a systematic method to generate high-quality synthetic training data (data-label pairs) to train the guidance neural network. The trained neural network can provide high-fidelity predictions even for field-data images that are not in the training data. We validate our new imaging method using one synthetic and two field ground-penetrating radar data examples, and find that our method can produce clean, high-resolution subsurface reflectivity images where existing single-pass and least-squares imaging methods fail due to noise and insufficient data coverage.

58 GEOSCIENCES↗

Stroboscopic ultrafast imaging using RF strip-lines in a commercial transmission electron microscope

The development of ultrafast electron microscopy (UEM), specifically stroboscopic imaging, has brought the study of structural dynamics to a new level by overcoming the spatial limitations of ultrafast spectroscopy and the temporal restrictions of traditional TEM simultaneously. Combining the concepts governing both techniques has enabled direct visualization of dynamics with spatiotemporal resolutions in the picosecond-nanometer regime. Here, in this study, we push the limits of imaging using a pulsed electron beam via RF induced transverse deflection based on the newly developed 200 keV frequency-tunable strip-line pulser. We demonstrate 0.2 nm spatial resolution at high magnifications and elucidation of Lorentz imaging using the phase-microscopy method. We also present beam coherence measurements and expand our study using the breathing modes of a silicon interdigitated comb under RF excitation which achieves improved temporal synchronization between the electron pulse-train and electric field. A new RF holder has also been developed with impedance matching to the RF signal to minimize transmission power loss to samples and its performance is compared with a conventional sample holder.

47 OTHER INSTRUMENTATION↗

Synthetic-aperture radar (SAR) imaging with range-resolved reflection data

SAR imaging may be performed with range-resolved reflection data, where a spread-spectrum signal, such as a code division multiple access (CDMA) signal, is transmitted instead of a simple frequency chirp. The reflected spread-spectrum signal may be analyzed to gather range-resolved reflection data. Range-resolved reflection data may be gathered at each angular view. This data may be used to construct a more accurate approximation of the Fourier transform of the desired image than can be done by a conventional SAR approach. The image may be reconstructed from this Fourier transform using Fourier inversion techniques similar to those used in conventional SAR approaches. The range-resolved reflection scheme generally requires somewhat more processing to recover the image as compared with conventional SAR systems, but provides a significantly more stable image with less degradation from effects that plague conventional SAR systems. This can eliminate the need for phase coherency altogether and also eliminate “phase drift,” which leads to image distortion. This may be especially well suited for high resolution imaging of relatively large targets.

47 OTHER INSTRUMENTATION↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

X-ray free-electron laser based dark-field X-ray microscopy: a simulation-based study

Dark-field X-ray microscopy (DFXM) is a nondestructive full-field imaging technique providing three-dimensional mapping of microstructure and local strain fields in deeply embedded crystalline elements. This is achieved by placing an objective lens in the diffracted beam, giving a magnified projection image. So far, the method has been applied with a time resolution of milliseconds to hours. In this work, the feasibility of DFXM at the picosecond time scale using an X-ray free-electron laser source and a pump–probe scheme is considered. Thermomechanical strain-wave simulations are combined with geometrical optics and wavefront propagation optics to simulate DFXM images of phonon dynamics in a diamond single crystal. Using the specifications of the XCS instrument at the Linac Coherent Light Source as an example results in simulated DFXM images clearly showing the propagation of a strain wave.

47 OTHER INSTRUMENTATION↗