Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Chemo–mechanical properties of carbon fiber reinforced geopolymer interphase

Geopolymers, as a potentially environmentally friendly alternative to Portland cement, are increasingly attracting attention in the construction industry. Various methods have been applied for customizing the properties of geopolymers and improving their commercial viability. One of the promising methods for refining the properties of geopolymers such as their toughness is the use of short fibers. The effectiveness of a high-strength short fiber in the geopolymer matrix is largely dependent on the interfacial bonding between the fiber and its surrounding matrix. While the importance of this interfacial chemistry is highlighted in the literature, the characteristics of this bonding structure have not been fully understood. In this paper, we aim to investigate the bonding mechanism between the carbon fiber and metakaolin-based geopolymer matrix. For the first time, the existence and nature of the chemical bonding at the interfacial region (interphase) between carbon fiber and geopolymer matrix has been revealed. X-ray pair distribution function computed tomography (PDF-CT), field emission-scanning electron microscopy imaging, and nanoindentation techniques are employed to discern the chemo-mechanical properties of the interphase. PDF-CT results show the emergence of a new atom-atom correlation at the interfacial region (around 1.82 angstrom). This correlation is a characteristic of interfacial bonding between the fiber and its surrounding matrix, where the existence of chemical linkages (potentially Al-V-O-C) between fibers and the matrix contributes to the adhesion between the two constituents making up the composite. Due to such chemical bonding, the nanomechanical properties of the interfacial region fall between that of the carbon fiber and geopolymer. The combination of advanced techniques is proved useful for enhancing our understanding of the interfacial chemistry between fibers and the binding matrix. This level of knowledge facilitates the engineering of composite systems through the manipulation of their nanostructure.

36 MATERIALS SCIENCE↗

Identification of New Lithic Clasts in Lunar Breccia 14305 by Micro-CT and Micro-XRF Analysis

From 1969 to 1972, Apollo astronauts collected 382 kg of rocks, soils, and core samples from six locations on the surface of the Moon. The samples were initially characterized, largely by binocular examination, in a custom-built facility at Johnson Space Center (JSC), and the samples have been curated at JSC ever since. Despite over 40 years of study, demand for samples remains high (~500 subsamples per year are allocated to scientists around the world), particularly for plutonic (e.g., anorthosites, norites, etc.) and evolved (e.g., granites, KREEP basalts) lithologies. The reason for the prolonged interest is that as new scientists and new techniques examine the samples, our understanding of how the Moon, Earth, and other inner Solar System bodies formed and evolved continues to grow. Scientists continually clamor for new samples to test their emerging hypotheses. Although all of the large Apollo samples that are igneous rocks have been classified, many Apollo samples are complex polymict breccias that have previously yielded large (cm-sized) igneous clasts. In this work we present the initial efforts to use the non-destructive techniques of micro-computed tomography (micro-CT) and micro x-ray fluorescence (micro-XRF) to identify large lithic clasts in Apollo 14 polymict breccia sample 14305. The sample in this study is 14305,483, a 150 g slab of regolith breccia 14305 measuring 10x6x2 cm (Figure 1a). The sample was scanned at the University of Texas High-Resolution X-ray CT Facility on an Xradia MicroXCT scanner. Two adjacent overlapping volumes were acquired at 49.2 micrometer resolution and stitched together, resulting in 1766 slices. Each volume was acquired at 100 kV accelerating voltage and 98 mA beam current with a 1 mm CaF2 filter, with 2161 views gathered over 360deg at 3 seconds acquisition time per view. Micro-XRF analyses were done at Washington University in St. Louis, Missouri on an EDAX Orbis PC micro-XRF instrument. Multiple scans were made at 40 kV accelerating voltage, 800 mA beam current, 30 μm beam diameter, and a beam spacing of 30-120 micrometer. The micro-CT scan of 14305,483 (Figure 2) was able to identify several large lithic clasts (approx. 1 cm) within the interior of the slab. These clasts will be exposed by band-sawing or chipping of the slab, and their composition more fully characterized by subsequent micro-XRF analysis. In addition to lithic clasts, the micro-CT scans identified numerous mineral clasts, including many FeNi metal grains, as well as the prominent fractures within the slab. The micro-XRF analyses (Figure 1b,c) of the slab surfaces revealed the bulk chemical compositions (qualitative) of the different clast types observed. In particular, by looking at the ratios of major elements (e.g. Ca:Mg:Fe), differences among the many observed clast types are readily observed. Moreover, several clasts not apparent to the naked eye were revealed in the K:Al:Si ratio map. The scans are also able to identify small grains of Zr- and P-rich minerals (not shown), which could in turn yield important age dates for the samples.

Zeigler, Ryan A.↗

Automatic threat recognition system and method using material disambiguation informed by physics in x-ray CT images of baggage

An automatic threat recognition (ATR) system is disclosed for scanning an article to recognize contraband items or items of interest contained within the article. The ATR system uses a CAT scanner to obtain a CT image scan of objects within the article, representing a plurality of 2D image slices of the article and its contents. Each 2D image slice includes information forming a plurality of voxels. The ATR system includes a computer and determines which voxels have a likelihood of representing materials of interest. It then aggregates those voxels to produce detected objects. The detected objects are further classified as items of interest vs. not of interest. The ATR system is based on learned parameters for a novel interaction of global and object context mechanisms. ATR system performance may be optimized by using jointly optimal global and object context parameters learned during training. The global context parameters may apply to the article as a whole and facilitate object detection. The object context parameters may apply to the individual object detections.

Paglieroni, David W.↗

High resolution computed tomography of advanced composite and ceramic materials

Advanced composite and ceramic materials are being developed for use in many new defense and commercial applications. In order to achieve the desired mechanical properties of these materials, the structural elements must be carefully analyzed and engineered. A study was conducted to evaluate the use of high resolution computed tomography (CT) as a macrostructural analysis tool for advanced composite and ceramic materials. Several samples were scanned using a laboratory high resolution CT scanner. Samples were also destructively analyzed at the locations of the scans and the nondestructive and destructive results were compared. The study provides useful information outlining the strengths and limitations of this technique and the prospects for further research in this area.

Yancey, R. N.↗

Computed Tomography For Inspection Of Thermistors

Computed tomography (CT) enables identification of cracked thermistors without disassembly of equipment containing them. CT unit used to scan equipment and locate thermistors. Further scans made in various radial orientations perpendicular to plane of devices to find cracks. Cracks invisible in conventional x-radiographs seen.

Schaefer, Lloyd A.↗

The X-ray attenuation characteristics and density of human calcaneal marrow do not change significantly during adulthood

Changes in the material characteristics of bone marrow with aging can be a significant source of error in measurements of bone density when using X-ray and ultrasound imaging modalities. In the context of computed tomography, dual-energy computed techniques have been used to correct for changes in marrow composition. However, dual-energy quantitative computed tomography (DE-QCT) protocols, while increasing the accuracy of the measurement, reduce the precision and increase the radiation dose to the patient in comparison to single-energy quantitative computed tomography (SE-QCT) protocols. If the attenuation properties of the marrow for a particular bone can be shown to be relatively constant with age, it should be possible to use single-energy techniques without experiencing errors caused by unknown marrow composition. Marrow was extracted by centrifugation from 10 mm thick frontal sections of 34 adult cadaver calcanei (28 males, 6 females, ages 17-65 years). The density and energy-dependent linear X-ray attenuation coefficient of each marrow sample were determined. For purposes of comparing our results, we then computed an effective CT number at two GE CT/i scan voltages (80 and 120 kVp) for each specimen. The coefficients of variation for the density, CT number at 80 kVp and CT number at 120 kVp were each less than 1%, and the parameters did not change significantly with age (p > 0.2, r2 < 0.02, power > 0.8 where the minimum acceptable r2 = 0.216). We could demonstrate no significant gender-associated differences in these relationships. These data suggest that calcaneal bone marrow X-ray attenuation properties and marrow density are essentially constant from the third through sixth decades of life.

NASA Discipline Musculoskeletal↗

Wettability Alteration with Weak Acid-Assisted Surfactant Flood

Oil-wetness and heterogeneity are two key reasons for low oil recovery by waterflooding in carbonate reservoirs. Surfactants have been effective in altering the oil-wet matrix to a more water-wet condition and initiating spontaneous imbibition. Because it takes time for the surfactant to alter wettability, oil recovery from the tight matrix is slow and sometimes not economically feasible. Acids have the potential of dissolving minerals, which may alter wettability. In this study, the enhanced oil recovery (EOR) performance of an acid-assisted surfactant solution, a novel technique, was evaluated for low-temperature applications. A set of acids and their acetates were tested. Bulk rock-acid reaction, wettability alteration (WA) tests, and spontaneous imbibition measurements were conducted at reservoir temperature (35°C) to identify effective candidates. Coreflood tests were then performed to evaluate the selected acid-surfactant formulations. Before and after a coreflood test, the core was scanned using micro-computed tomography (CT) to investigate pore structure alteration. Bulk reaction measurements showed that weak acids, especially acetic acid (AA), have the desired low reaction rates at 35°C. WA tests showed that AA can remove the crude oil off the rock surface and alter wettability through mineral dissolution. The surfactant can reduce contact angles from 160° to 58°; adding acid into the surfactant can further reduce it to 52°. Spontaneous imbibition experiments showed the synergy between the acid and the surfactant; the AA-surfactant solution had the highest oil recovery (62.6%) among acid-surfactant formulations. The acid improves the WA efficiency by the surfactant through surface mineral dissolution and lower ζ-potential. The imbibition transports the acid-surfactant solutions into the matrix, which minimizes face dissolution. Coreflood tests show that the AA-surfactant flood can increase the oil recovery rate and recover about 8% more oil compared to the surfactant flood. Micro-CT showed that a few mineral particles were transported along the core and partially plugged pore throats, which reduced permeability and diverted flow leading to improved oil recovery. Here, the transport of the acid in reservoirs and the potential plugging issues have to be carefully evaluated in future studies.

58 GEOSCIENCES↗

Shifts in valence states in bimetallic MXenes revealed by electron energy-loss spectroscopy (EELS)

MXenes are an emergent class of two-dimensional materials with a very wide spectrum of promising applications. The synthesis of multiple MXenes, specifically solid-solution MXenes, allows fine tuning of their properties, expands their range of applications, and leads to enhanced performance. The functionality of solid-solution MXenes is closely related to the valence state of their constituents: transition metals, oxygen, carbon, and nitrogen. However, the impact of changes in the oxidation state of elements in MXenes is not well understood. In this work, three interrelated solid-solution MXene systems (Ti$_{2–y}$Nb$_y$CT$_x$, Nb$_{2–y}$V$_y$CT$_x$, and Ti$_{2–y}$V$_y$CT$_x$) were investigated with scanning transmission electron microscopy and electron energy-loss spectroscopy to determine the localized valence states of metals at the nanoscale. The analysis demonstrates changes in the electronic configuration of V upon modification of the overall composition and within individual MXene flakes. These shifts of oxidation state can explain the nonlinear optical and electronic features of solid-solution MXenes. Vanadium appears to be particularly sensitive to modification of the valence state, while titanium maintains the same oxidation state in Ti–Nb and Ti–V MXenes, regardless of stoichiometry. Here, the study also explains Nb's influential role in the previously observed electronic properties in the Nb–V and Nb–Ti systems.

36 MATERIALS SCIENCE↗

Measuring Multicomponent Adsorption of Tracer Gases on Natural Zeolites

A natural clinoptilolite sample near the Nevada National Security Site was obtained to study adsorption and retardation on gas transport. Of interest is understanding the competition for adsorption sites that may reduce tracer gas adsorption relative to single-component measurements, which may be affected by the multi-scale pore structure of clinoptilolite. Clinoptilolite has three distinct domains of pore size distributions ranging from nanometers to micrometers: micropores with 0.4–0.7 nm diameters, measured on powders by CO2 adsorption at 273 K, representing the zeolite cages; mesopores with 4–200 nm diameters, observed using liquid nitrogen adsorption at 77 K; and macropores with 300–1000 nm diameters, measured by mercury injection on rock chips (~ 100 mesh), likely representing the microfractures. These pore size distributions are consistent with X-ray computed tomography (CT) and focused ion beam scanning electron microscope (FIB-SEM) images, which are used to construct the three-dimensional (3D) pore network to be used in future gas transport modeling. To quantify tracer gas adsorption in this multi-scale pore structure and multicomponent gas species environment, natural zeolite samples initially in equilibrium in air were exposed to a mixture of tracer gases. As the tracer gases diffuse and adsorb in the sample, the remaining tracer gases outside the sample fractionate. Using a quadrupole mass spectrometer to quantify this fractionation, the degree of adsorption of tracer gases in the multicomponent gas environment and multi-scale pore structure is assessed. The major finding is that Kr reaches equilibrium much faster than Xe in the presence of ambient air, which leads to more Kr uptake than Xe over limited exposure periods. When the clinoptilolite chips were exposed to humid air, the adsorption capability decreases significantly for both Xe and Kr with relative humidity (RH) as low as 3%. Both Xe and Kr reaches equilibrium faster at higher RH. The different, unexpected, adsorption behavior for Xe and Kr is due to their kinetic diameters similar to the micropores in clinoptilolite which makes it harder for Xe to access compared to Kr.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CO 2 /Brine/Rock Interactions in the Cedar Keys-Lawson Formation

It has been reported that among the various geologic storage options, deep saline aquifers have the largest estimated capacity for CO 2 storage. Obtaining knowledge of possible artificially geochemically induced changes to the permeability and porosity of host CO 2 storage deposits will enable us to gain insight on long-term reservoir behavior under CO 2 storage conditions. An experimental study of the interaction of CO 2 /brine/rock on saline formations was conducted in a static system under CO 2 storage conditions. Chemical interactions in the Cedar Keys-Lawson Formation carbonate during exposure to CO 2 and brine under sequestration conditions were studied. Samples were exposed to the simulated in-situ reaction conditions for one and six months. The samples were exposed to a model brine at 55 °C and CO 2 pressure of 23.8 MPa (3,500 psig). Computed tomography (CT), x-ray diffraction (XRD), scanning electron microscopy (SEM)-energy dispersive x-ray spectroscopy (EDS), brine composition, core porosity, and core permeability analyses were conducted prior to and after the exposure experiments. Preliminary permeability measurements obtained from the core samples showed changes after they were exposed to CO 2 -saturated brine for one and six months. This observation suggests that mineral dissolution and mineral precipitation could occur in the host deposit altering its characteristics for CO 2 storage over time. The 3D images of the pore space clearly illustrate the degree of dissolution that occurred during exposure. It is noted that the dissolution that occurred during the six-month exposure could have enhanced the connectivity between voids. This may contribute the increase of permeability after the CO 2 /brine exposure. In addition, the primary minerals comprising the core are dolomite and gypsum. Both minerals could dissolve in the CO 2 /brine environment resulting in the increase of permeability after the six-month exposure.

58 GEOSCIENCES↗

Computed tomography for non-destructive evaluation of composites: Applications and correlations

The state-of-the-art fabrication techniques for composite materials are such that stringent species-specific acceptance criteria must be generated to insure product reliability. Non-destructive evaluation techniques including computed tomography (CT), X-ray radiography (RT), and ultrasonic scanning (UT) are investigated and compared to determine their applicability and limitations to graphite epoxy, carbon-carbon, and carbon-phenolic materials. While the techniques appear complementary, CT is shown to provide significant, heretofore unattainable data. Finally, a correlation of NDE techniques to destructive analysis is presented.

Goldberg, B.↗

X-ray computed tomography-based porosity analysis: Algorithms and application for porous woody biomass

The properties of lignocellulosic biomass, such as bulk physical, thermal, and mechanical properties, as well as the mobility of enzymes or catalysts, are largely affected by porosity, pore structures, and pore size distribution. While X-ray computed tomography (CT) has been introduced to effectively produce 3D volumetric images of material microstructure, a quantitative porosity analysis from the 3D images has never been done. This work introduces a first-of-its-kind X-ray CT-based quantitative porosity analysis method and applies the developed toolkit to characterize the internal porosity distribution of loblolly pine. A sample loblolly pine chip was scanned by a nano-resolution X-ray CT system and digitally reconstructed after a sequence of image processing operations. Here, a comprehensive porosity analysis was then performed to quantify the envelope porosity, the spatial distribution of local porosity, and the directional porosity. Solutions to the various challenges in image processing, porosity calculation, and large data handling are provided.

42 ENGINEERING↗

Discovery of nanopore filling by gypsum in wellbore cement exposed to 17 MPa CO 2 under geologic carbon storage conditions

Here, this study investigates the pore structure evolution of the reaction zones in wellbore cement samples exposed to a CO 2 -rich solution in equilibrium with 17 MPa supercritical CO 2 over 14 days. Through advanced characterization methods of field emission SEM, Quantitative Evaluation of Minerals by Scanning Electron Microscopy (QEMSCAN), and micro-CT, a new mechanism of CO 2 -cement reaction involving filling of nanopores in the interior of cement by gypsum was revealed. Gypsum was formed by the liberation of SO 4 2− from ettringite (AFt) and monosulfate (AFm) caused by a decrease in pH. Based on these experimental observations, a new CO 2 -cement reaction model that incorporates four distinct reaction zones is developed. This model provides a comprehensive framework for understanding the spatial and temporal distribution of minerals in cement due to high pressure CO 2 —cement reactions. This study demonstrates that the major damage induced by high pressure CO 2 alteration occurs in the most exterior region of the cement. The interior region of the cement maintains its integrity due to nanopore filling by gypsum.

54 ENVIRONMENTAL SCIENCES↗

Executive Micro-CT Low-resolution Summary for Catheter Parts [Slides]

Data scans were performed on a Zeiss Xradia 520 Versa operated by departments 1851 (Philip Noell) and 1819 (James Griego). Sample 1, 2, and 3 Catheters were scanned with a 30 um pixel (low-resolution) to get an overall view of the part. (This does not include the entire height of the catheter assembly.) The following slides show the Z, Y, and X slice plane at a specific cross-hair location. We can perform a higher resolution scan down to —0.7 um pixel size including a limited field of view of ~700 um wide. Slide 5 has some requests for the customer for further scan locations. These catheters were provided to us by Simon Dunham of Weill Cornell Medical College.

59 BASIC BIOLOGICAL SCIENCES↗

Creep/Stress Rupture Behavior of 3D Woven SiC/SiC Composites with Sylramic-iBN, Super Sylramic-iBN and Hi-Nicalon-S Fibers at 2700F in Air

To determine the influence of fiber types on creep durability, 3D SiC/SiC CMCs were fabricated with Sylramic-iBN, super Sylramic-iBN and Hi-Nicalon-S fibers and the composite specimens were then tested under isothermal tensile creep at 14820C at 69, 103 and 138 MPa for up to 300hrs in air. The failed specimens were examined by scanning electron microscopy (SEM) and computed tomography (CT) for fracture mode analysis. The creep data of these composites are compared with those of other SiC/SiC composites in the literature. The results of this study will be presented.

failure modes↗

Impact Damage Tolerance of Composite Laminates with Through-The-Thickness Stitches

The ability of through-the-thickness stitches to contain damage during a low-velocity impact event and increase the residual strength of stitched panels was investigated in this research. The impact response, spread of interlaminar delaminations, dent depth, surface damage, and static residual strength after impact were studied for carbon-epoxy specimens fabricated from HTS40 TohoTenax standard modulus fibers, stitched together with Vectran 1200 denier thread and infused with API 1078 resin after through-the-thickness stitching. Three different stitch patterns were used to explore the ability to arrest impact damage during and after impact. Simply supported boundary conditions were maintained during the impact testing. Non-destructive evaluations were performed using ultrasonic C-scans and X-ray computed tomography (CT) imaging to determine the shape, size, and location of delaminations. Results indicate that while the dynamic response during the impact event was almost the same for the unstitched specimens and all stitch patterns considered, the extent of delamination and the compression strength after impact varied greatly. For both the 60 J and 80 J impact energies, the delamination area was significantly less for the stitched specimens than for the unstitched specimens, but the range of delamination areas among the stitch patterns was much larger for the lower impact energy than for the greater impact energy. Similarly, while the presence of stitching influenced the compression after impact strength, the strength values for all stitch patterns were very similar. These results are a step toward quantifying the influence of through-the-thickness stitching.

Ranatunga, Vipul↗

Characterizing Char Rate and Extent in Fiber-Reinforced Plastics Using X-ray Computed Tomography

Orbital debris is a growing problem for the space industry and the world in general, and an important component of the problem is what happens when that debris reenters the Earth’s atmosphere. With more spacecraft opting for fiber-reinforced polymer (FRP) components, we need to understand the thermal destruction process of these materials during an atmospheric reentry and how much of the material can survive to impact the ground. The NASA Orbital Debris Program Office (ODPO) has developed a new charring model for FRP components to be integrated into the latest version of the Object Reentry Survival Analysis Tool (ORSAT). To validate this new model, the ODPO performed several test series using the Inductively Coupled Plasma (ICP) Torch facility at UT Austin. To measure the extent of charred material at different conditions, some of the test samples were scanned using x-ray computed tomography (CT) by the Astromaterials Curation Lab at Johnson Space Center. 3D image analysis was then used to calculate the volume and density of the char in each test sample. This paper presents the image analysis methodology, an assessment of the accuracy of the data analysis, and a comparison with calculations using the ORSAT charring model.

Benton Greene↗

Geometrical-Based Generative Adversarial Network to Enhance Digital Rock Image Quality

X-ray microcomputed tomography (micro-CT) is a common tool for the study of porous media structures and properties. High-quality micro-CT data are required to accurately capture pore structures. Acquiring high-quality micro-CT data, however, is not always possible, owing to application limitations and experimental constraints. Therefore, we propose a geometrical-based generative adversarial network (GAN) to rapidly restore noisy micro-CT images to their clean counterparts. The training data and related ground-truth (GT) data are scanned for 7 min and 9.5 h, respectively. To evaluate the performance of the geometrical-based GAN, a 6003 voxel image that has never been used for training is reconstructed and compared with the corresponding GT image. Histogram matching and linear normalization are implemented to adjust the histogram of the reconstructed image to that of the GT image. A watershed-based segmentation method is then applied to delineate pore and solid phases. Lastly, we measure the Minkowski functionals and petrophysical properties, including absolute permeability, pore size distribution, drainage capillary pressure-saturation curve, and imbibition relative permeability, to estimate the physical accuracy of the denoised image. The results show that the proposed geometrical-based GAN can accurately restore noisy micro-CT data. By reducing the scanning time from 9.5 h to 7 min, the expenditure of collecting micro-CT can be decreased significantly. This is particularly important for applications where time-lapse images of a dynamic process are required, high-throughput imaging is necessary for real-time data analysis, or where the quantification of large sample volumes is required.

58 GEOSCIENCES↗