Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONVERTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A Flux Balancing Strategy for 10-kV SiC-Based Dual-Active-Bridge Converter

The transformer flux unbalance in dual-active-bridge (DAB) converters is a critical issue due to the electrical parameter and modulation mismatch, and load or control transients. Compared to low voltage DAB converters, the unbalance problem in medium voltage DAB converters may cause more severe problem, and become more difficult to deal with, because of the high operating voltage and insulation requirement. In this paper, a flux balancing strategy for a medium voltage (MV) DAB converter is proposed, including the transformer design with ferrite gap, current harmonic-based unbalance detection, as well as the flux balancing control scheme. With the proposed ferrite gap, nonlinear magnetizing current and its modeling are induced. Then, by analyzing the current harmonics, the flux unbalance level can be detected, and hence controlled. Test results have verified the proposed method in a MV DAB converter.

Gao, Zihan↗

SU-F-T-555: Accurate Stereotactic Cone TMRs Converted from PDDs Scanned with Ray Trace

Purpose: To investigate whether the accuracy of TMRs for stereotactic cones converted from PDDs scanned with Ray Trace can be improved, when compared against the TMRs converted from the traditional PDDs. Methods: Ray Trace measurement in Sun Nuclear 3D Scanner is for accurate scan of small field PDDs. The system detects the center of field at two depths, for example, at 3 and 20 cm in our study, and then performs scan along the line passing the two centers. With both Ray Trace and the traditional method, PDDs for conical cones of 4, 5, 7.5, 10, 12.5, 15, and 17.5 mm diameter (jaws set to 5×5 cm) were obtained for 6X FFF and 10X FFF energies on a Varian Edge linac, using Edge detectors. The formalism of converting PDD to TMR given in Khan’s book (4th Edition, p.161) was applied. Sp values at dmax were obtained by measuring cone Scp and Sc. Continuous direct measurement of TMR by filling/draining water to/from the tank and spot measurement by moving the tank and detector were also performed with the same equipment, using 100 cm SDD. Results: For 6XFFF energy and all the cones, TMRs converted from Ray Trace were very close to the continuous and spot measurement, while TMRs converted from traditional PDDs had larger deviation. Along the central axis beyond dmax, 1.7% of TMR data points calculated from Ray Trace had more 3% deviation from measurement, with maximal deviation of 5.2%. Whereas, 34% of TMR points calculated from traditional PDDs had more than 3% deviation, with maximum of 5.7%. In this initial study, Ray Trace scans for 10XFFF beam were noisy, further measurement is warranted. Conclusion: The Ray Trace could improve the accuracy of PDDs measurement and the calculated TMRs for stereotactic cones, which was within 3% of the measured TMRs.

60 APPLIED LIFE SCIENCES↗

Global Threat Reduction Initiative (GTRI): PNNL GTRI Convert Program (Program Management Plan)

The National Nuclear Security Administration (NNSA) Global Threat Reduction Initiative (GTRI) strategic mission includes efforts to reduce and protect vulnerable nuclear and radiological material at civilian sites around the world. Converting research reactors from using highly enriched uranium (HEU) to low enriched uranium (LEU) was originally started in 1978 as the Reduced Enrichment for Research and Test Reactors Program under the U.S. Department of Energy (DOE) Office of Science. In 2004, the NNSA established the GTRI by combining five existing programs, including the Reduced Enrichment for Research and Test Reactors Program, under one combined threat reduction initiative to focus on one common mission. Within this strategic mission, the GTRI has three goals that provide a comprehensive approach to achieving this mission: 1) convert research reactors from using HEU to LEU, 2) remove or dispose of excess nuclear and radiological materials, and 3) protect nuclear and radiological material from theft and sabotage. The GTRI Convert mission seeks to minimize and, to the extent possible, eliminate HEU in civilian applications throughout the world through the conversion of research reactors. Once that need is eliminated, remaining HEU fresh and spent fuel can be removed or disposed of by GTRI’s Remove activities. Attainment of the Convert objectives will permanently reduce the availability and affiliated transactions of HEU materials, thus eliminating a substantial threat to proliferation. GTRI’s Convert mission is comprised of two sub-programs: the GTRI Reactor Conversion Program and the Mo-99 Capability Development Project.

Cleary, Eugene J.↗

Integration of High-Z Converter into Full-scale Production Target for Accelerator-based Production of 99 Mo

NorthStar Medical Technologies is planning to produce the 99Mo isotope via the photonuclear route. The Rhodotron accelerator designed by IBA will be used as an electron-beam source. The Rhodotron is an efficient recirculating accelerator, providing low energy dispersion and a low-emittance electron beam. The nominal beam power is assumed to be 120 kW at 40 MeV. In photonuclear production of 99 Mo, a high-power electron beam impinges on a helium-cooled Mo disk target. Electrons are converted into photons through the Bremsstrahlung process. Consequently, high-energy photons interact with the target nuclei, producing 99 Mo through the 100 Mo(γ, n) 99 Mo reaction. Traditionally, photonuclear production is realized using high-Z material as the electron-to-photon converter. NorthStar plans not to use a high-Z converter in the initial production target design, but it may be interested in the increased production capabilities a high-Z converter can provide. The purpose of this report is to evaluate the advantages and disadvantages of incorporating a high-Z converter into the target design.

07 ISOTOPE AND RADIATION SOURCES↗

Applying Machine Learning to the Classification of DC-DC Converters. NA-22 Final Report

Tools are now available that enable measurement electromagnetic radiation (EMR) from active electronics in an item. This radiation may be intended WIFI or cellular network links, for example or unintended such as the switching noise generated by DC-to-DC converters. It would be extremely valuable to have the capability to discriminate between the low-voltage DC-to-DC converters or other digital noise prevalent in most modern electronics, versus the high-voltage DC-to-DC converters used in utility firesets. Previous work performed under a Sandia Laboratory Directed Research and Development (LDRD) project on Charge State Detection using a deep neural network has been continued in this effort. A state-of-the-art supervised machine learning algorithm has not only been extended to discriminate between low and high voltage converters but has been validated in determining a converters make and model.

42 ENGINEERING↗

Experimental Validation of a Modular All-Electric Power Take-Off Topology for Wave Energy Converter Enabling Marine Renewable Energy Interconnection

Power electronic converters are an enabling technology for the emerging marine energy applications, such as using ocean waves to produce electricity. This paper outlines the power take-off system and its key components used in a wave energy converter offering modularity and scalability to generate power efficiently. The proposed power take-off system was implemented based on a modular multilevel converter and could be deployed to convert any alternating current electrical energy to a different alternating current for interconnection to grid or non-grid applications. Examples of widespread deployment are supplying electricity to coastal communities or producing clean drinking water. The analysis using both the simulation tests and laboratory experiments verified the design objectives and basic functionality of the developed power take-off system. An acceptable response using a field programmable gate array-based controlled laboratory testbench was achieved, complying with guidelines specified in the prevalent industry standards. Seamless operation during steady-state and transients for the studied wave energy converter was achieved as supported by the obtained results. The key findings of this work were experimentally examined under different load conditions, direct current bus voltage fluctuations, and generator speed–torque regulation. The ability of the power take-off system to generate high-power quality of the waveforms, e.g., against adhering to the IEEE 519-2022 standard for total harmonic distortion limits, is also confirmed.

Engineering↗

Regulated dc-to-dc converter for voltage step-up or step-down with input-output isolation.

A dc-to-dc regulated-converter circuit employing duty-cycle control with variable on and variable off time has been presented. A unique feature of this converter is the method by which the bistable-comparator output controls the duty cycle of the power switching transistor through the action of the encoder. The utilization of minor-loop flux excursions of a saturable-core transformer in the encoder makes it feasible to extend the converter switching frequency considerably higher than would normally be possible. With this converter circuit, high and very-high frequency converter operations were explored.

Feng, S. Y. M.↗

Reactor core length, externally configured thermionic converter.

Results of testing a converter having an external emitter configuration for 190 hours using RF induction heating. The converter was assembled with a rhenium emitter, 25.4 cm long, having a 91.2 sq cm emitting area, and a niobium collector with a molybdenum coating to improve its electronic property. The collector was water-cooled. The test included: static power output measurements, dynamic characteristics, and the effects of the temperature distribution along the emitter. The maximum power output achieved from the converter at an emitter temperature of 1942 K was 178 W at 0.48 V output, with a power density of 1.95 W/sq cm and an efficiency of 5.5%. The static characteristics also indicated that, with a constant power input, the converter power output does not vary with the output voltage as a result of self-adjustment of the emitter temperature. An investigation of the effects of the temperature distribution along the emitter length showed a 33% improvement in the converter output power with a flattening of the emitter temperature.

Shimada, K.↗

Out-of-core evaluations of a nonfueled and a UO2-fueled cylindrical thermionic converter.

Two cylindrical thermionic energy converters similar to those in a flashlight thermionic fuel element were tested electrically at the Jet Propulsion Laboratory. One converter was not fueled, but the other was fueled with UO2 imbedded in six pencil-lead-size holes in the emitter, which was made of rhenium. The nonfueled converters showed no change in its performance during 4000 hr of testing, whereas the output current of the UO2-fueled converter degraded 15% during 2400 hr of testing at 2000 K. Measurements on the UO2-fueled converter showed an increase in the collector work function and an increase in the bare emitter work function. The degradation appears to be caused primarily by foreign deposits on the collector, probably uranium that diffused from the UO2 fuel through the emitter.

Shimada, K.↗

Evaluations of uranium-nitride fueled converters.

Evaluation of two uranium-nitride (UN) fueled converters was initiated at the Jet Propulsion Laboratory to investigate the effect of fuel on the converter performance while being operated out-of-core. The initial tests were performed with the dynamic data acquisition system that was developed at the Laboratory. Parametric tests of these converters were to obtain: (1) static volt-ampere curves, (2) dynamic volt-ampere curves, and (3) the electrode work functions. The power outputs were 9.3 W/sq cm for the rhenium converter and 3.8 W/sq cm for the tungsten converter at 0.6 V when the emitter surface temperature was 2000 K, according to the static volt-ampere curves.

Shimada, K.↗

Postoperational examination of an externally configured thermionic converter

An externally configured thermionic converter was operated for 200 h. The converter was disassembled and examined to determine internal changes as a result of operation. The metal/ceramic seals and all joints were unaffected by operation. Converter output voltage and operational time were sufficient to produce electrolysis of stabilized zirconia spacers used in the converter. Surface analysis of the electrode surfaces indicated the presence on the tungsten emitter of only oxygen, carbon, and silicon. The niobium collector was, however, 25 to 40% covered with other elements. This coverage represented all elements present within the converter as construction materials other than silicon and tungsten, which were not detected on the collector, and carbon, which was detected only in small amounts.

Phillips, W. M.↗

Fabrication and life testing of thermionic converters

An unfueled converter containing a chloride-fluoride duplex tungsten emitter of 4.78 eV vacuum work function was tested for 46,647 hours at an emitter temperature of 1973 K and an electrode power output of about 8 watts/sq cm. The test demonstrated the superior and stable performance of the (110) oriented tungsten emitter at high temperatures. Three 90 UC-10 ZrC(C/U = 1.04, tungsten additive = 4 wt %) fueled converters were fabricated and tested at an emitter temperature of 1873 K. Converter containing chloride-arc-cast duplex tungsten cladding showed temperature thermionic performance and slower rate of performance drop than converter containing chloride-fluoride duplex tungsten cladding. This is believed to be due to the superior fuel component diffusion resistance of the arc-cast tungsten substrate used in the fuel cladding. It was shown that a converter containing a carbide fueled chloride-arc-cast duplex tungsten emitter with an initial electrode power output of 6.80 watts/sq cm could still deliver an electrode power output of 6.16 watts/sq cm after 18,632 hours of operation at an emitter temperature of 1873 K.

Yang, L.↗

Analysis of self-oscillating dc-to-dc converters

The basic operational characteristics of dc-to-dc converters are analyzed along with the basic physical characteristics of power converters. A simple class of dc-to-dc power converters are chosen which could satisfy any set of operating requirements, and three different controlling methods in this class are described in detail. Necessary conditions for the stability of these converters are measured through analog computer simulation whose curves are related to other operational characteristics, such as ripple and regulation. Further research is suggested for the solution of absolute stability and efficient physical design of this class of power converters.

Burger, P.↗

Design of Energy Storage Reactors for Dc-To-Dc Converters

Two methodical approaches to the design of energy-storage reactors for a group of widely used dc-to-dc converters are presented. One of these approaches is based on a steady-state time-domain analysis of piecewise-linearized circuit models of the converters, while the other approach is based on an analysis of the same circuit models, but from an energy point of view. The design procedure developed from the first approach includes a search through a stored data file of magnetic core characteristics and results in a list of usable reactor designs which meet a particular converter's requirements. Because of the complexity of this procedure, a digital computer usually is used to implement the design algorithm. The second approach, based on a study of the storage and transfer of energy in the magnetic reactors, leads to a straightforward design procedure which can be implemented with hand calculations. An equation to determine the lower-bound volume of workable cores for given converter design specifications is derived. Using this computer lower-bound volume, a comparative evaluation of various converter configurations is presented.

Chen, D. Y.↗

Analysis of a class of pulse modulated dc-to-dc power converters

The basic operational characteristics of dc-to-dc converters are analyzed. The basic physical characteristics of power converters are identified. A simple class of dc-to-dc power converters is chosen which could satisfy any set of operating requirements. Three different controlling methods in this class are described in detail. Necessary conditions for the stability of these converters are measured through analog computer simulation. These curves are related to other operational characteristics, such as ripple and regulation. Finally, further research is suggested for the solution of the physical design of absolutely stable, reliable, and efficient power converters of this class.

Burger, P.↗

Modelling, analyses and design of switching converters

A state-space averaging method for modelling switching dc-to-dc converters for both continuous and discontinuous conduction mode is developed. In each case the starting point is the unified state-space representation, and the end result is a complete linear circuit model, for each conduction mode, which correctly represents all essential features, namely, the input, output, and transfer properties (static dc as well as dynamic ac small-signal). While the method is generally applicable to any switching converter, it is extensively illustrated for the three common power stages (buck, boost, and buck-boost). The results for these converters are then easily tabulated owing to the fixed equivalent circuit topology of their canonical circuit model. The insights that emerge from the general state-space modelling approach lead to the design of new converter topologies through the study of generic properties of the cascade connection of basic buck and boost converters.

Cuk, S. M.↗

Recent progress in hybrid mode thermionic converter development

Thermionic research has been conducted to investigate a hybrid-mode thermionic converter as a candidate for reducing the barrier index. The hybrid-mode thermionic converter is designed to operate in a combination ignited mode and unignited mode by using a series of parallel grooves in the emitter. The emitter material is molybdenum and the non-grooved land area is thinly coated with rhenium metal. When the emitter is exposed to cesium vapor, as it is during the converter operation, the rhenium-coated land area achieves a lower work function than the grooved molybdenum surface by as much as 0.5 eV. The low work function land area provides a major portion of electron emission, and the high work function grooved area provides cesium ions required for efficient transport of electrons generated in adjacent land areas to the collector. Experimental results obtained from two different converters and a numerical analysis of converter characteristics are presented in this paper.

Shimada, K.↗

Low cost cylindrical converter for measuring lead efficiency

A low cost cylindrical thermionic converter has been designed, fabricated, and tested for use in a NASA-JPL program to directly measure converter lead efficiencies using various electrode materials and surfaces. Efficiency measurements are made using input emitter heater power, output power at the leads, and calculated values of the parasitic losses that would not be present in the application configuration. This information can be used to predict the performance characteristics of the advanced converters currently under development. A series of five converters has been tested. Both structured and smooth molybdenum collectors have been used. Emitters included smooth molybdenum, smooth rhenium, and microstructured rhenium. Cesium pressure families of current-voltage curves are presented for emitter temperatures of 1600, 1700, and 1800 K, along with measured efficiencies as a function of converter current densities for each temperature.

Hatch, G. L.↗