Category V Compliant Container for Mars Sample Return Missions
Mars Sample Return Mission will bring to Earth a sample that may contain a life form of extraterrestrial origin.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Mars Sample Return Mission will bring to Earth a sample that may contain a life form of extraterrestrial origin.
Neutron moderation effects were measured in bulk soil samples through prompt gamma ray measurements from water and benzene contaminated soil samples using 14 MeV neutron inelastic scattering. The prompt gamma rays were measured using a cylindrical 76 mm x 76 mm (diameter x height) LaBr{sub 3}:Ce detector. Since neutron moderation effects strongly depend upon hydrogen concentration of the sample, for comparison purposes, moderation effects were studied from samples containing different hydrogen concentrations. The soil samples with different hydrogen concentration were prepared by mixing soil with water as well as benzene in different weight proportions. Then, the effects of increasing water and benzene concentrations on the yields of hydrogen, carbon and silicon prompt gamma rays were measured. Moderation effects are more pronounced in soil samples mixed with water as compared to those from soil samples mixed with benzene. This is due to the fact that benzene contaminated soil samples have about 30% less hydrogen concentration by weight than the water contaminated soil samples. Results of the study will be presented. (authors)
In this paper, we report on a detailed spectroscopic study of the optical properties of InGaN/GaN multiple quantum well structures, both with and without a Si-doped InGaN prelayer. In photoluminescence and photoluminescence excitation spectroscopy, a 2nd emission band, occurring at a higher energy, was identified in the spectrum of the multiple quantum well structure containing the InGaN prelayer, originating from the first quantum well in the stack. Band structure calculations revealed that a reduction in the resultant electric field occurred in the quantum well immediately adjacent to the InGaN prelayer, therefore leading to a reduction in the strength of the quantum confined Stark effect in this quantum well. The partial suppression of the quantum confined Stark effect in this quantum well led to a modified (higher) emission energy and increased radiative recombination rate. Therefore, we ascribed the origin of the high energy emission band to recombination from the 1st quantum well in the structure. Study of the temperature dependent recombination dynamics of both samples showed that the decay time measured across the spectrum was strongly influenced by the 1st quantum well in the stack (in the sample containing the prelayer) leading to a shorter average room temperature lifetime in this sample. The room temperature internal quantum efficiency of the prelayer containing sample was found to be higher than the reference sample (36% compared to 25%) which was thus attributed to the faster radiative recombination rate of the 1st quantum well providing a recombination pathway that is more competitive with non-radiative recombination processes.
We present detailed surface photometry, based on broad B-band charge coupled device (CCD) images, of about 80 dwarf galaxies. Our sample represents approximately 10% of all dwarf galaxies identified in the vicinity of Revised Shapley-Ames (RSA) galaxies on high resolution blue photographic plates, referred to as the RSA survey of dwarf galaxies. We derive global properties and radial surface brightness profiles, and examine the morphologies. The radial surface brightness profiles of dwarf galaxies, whether early or late type, display the same varieties in shape and complexity as those of classical giant galaxies. Only a few are well described by a pure r(exp 1/4) law. Exponential profiles prevail. Features typical of giant disk galaxies, such as exponential profiles with a central depression, lenses, and even, in one case (IC 2041), a relatively prominent bulge are also found in dwarf galaxies. Our data suggest that the central region evolves from being bulge-like, with an r(exp 1/4) law profile, in bright galaxies to a lens-like structure in dwarf galaxies. We prove detailed surface photometry to be a helpful if not always sufficient tool in investigating the structure of dwarf galaxies. In many cases kinematic information is needed to complete the picture. We find the shapes of the surface brightness profiles to be loosely associated with morphological type. Our sample contains several new galaxies with properties intermediate between those of giant and dwarf ellipticals (but no M32-like objects). This shows that such intermediate galaxies exist so that at least a fraction of early-type dwarf ellipticals is structurally related to early-type giants instead of belonging to a totally unrelated, disjunct family. This supports an origin of early-type dwarf galaxies as originally more massive systems that acquired their current morphology as a result of substantial, presumable supernova-driven, mass loss. On the other hand, several early-type dwarfs in our sample are merger candidates. Merger events may lead to anisotropic velocity distributions in systems of any luminosity, including dwarfs. The RSA sample of dwarf galaxies is more likely to contain mergers because, in contrast to earlier dwarf galaxy surveys that have focused on clusters and rich groups of galaxies, the RSA dwarfs are typically located in low density environments. The occurrence of mergers among dwarf galaxies is of interest in connection with the rapid evolution of faint blue galaxy counts at redshift z less than 1 which suggests that dwarf galaxies were about five times more numerous in the recent past. Finally, our sample contains several examples of late-type dwarfs and 'transition' types that are potential precursors of nucleated early-type dwarfs. All the above processes--mass loss, mergers, astration--are likely to have contributed to the formation of the current population of diffuse early-type dwarfs. A few new redshifts of dwarf galaxies are reported in this paper.
We constructed the eROSITA X-ray catalog of radio galaxies discovered by the WERGS survey, made by cross-matching the wide area Subaru/Hyper Suprime-Cam (HSC) optical survey and VLA/FIRST 1.4 GHz radio survey. We report finding 393 eROSITA detected radio galaxies in the 0.5-2 keV band in the eFEDS field covering 140 deg 2 . Thanks to the wide and medium depth eFEDS X-ray survey down to f 0.5 - 2 keV = 6.5 × 10 -15 erg s -1 cm -2 , the sample contains the rare and most X-ray luminous radio galaxies above the knee of the X-ray luminosity function, spanning 44 < log(L 0.5-2 keV (abs,corr) /erg s -1 ) < 46.5 at 1 < z < 4. The sample also contains the sources around and below the knee for the sources 41 < log(L 0.5-2 keV (abs,corr) /erg s -1 ) < 45 at z < 1. Based on the X-ray properties obtained by the spectral fitting, 37 sources show obscured active galactic nucleus (AGN) signatures with log(N H /cm -2 ) > 22. These obscured and radio AGN reside in 0.4 < z < 3.2, indicating that they are obscured counterparts of the radio-loud quasar, which were missed in the previous optical quasar surveys. By combining radio and X-ray luminosities, we also investigated the jet production efficiency η jet = η rad P jet /L AGN,bol by utilizing the jet power of P jet . We find that there are 14 sources with extremely high jet production efficiency at η jet ≈ 1. This high η jet value might be a result of the decreased radiation efficiency of η rad < 0.1, due to the low accretion rate for those sources, and/or of the boosting due to the decline of L AGN,bol by a factor of 10-100 by keeping P jet constant in the previous Myr, indicating the experience of the AGN feedback. Finally, inferring the BH masses from the stellar mass, we find that X-ray luminous sources show the excess of the radio emission with respect to the value estimated from the fundamental plane. This radio emission excess cannot be explained by the Doppler boosting alone, and therefore the disk–jet connection of X-ray luminous eFEDS-WERGS is fundamentally different from the conventional fundamental plane which mainly covers the low-accretion regime.
Abstract not provided
Abstract Not Provided
The Comet Astrobiology Exploration SAmple Return (CAESAR) mission is one of two candidates selected by NASA in response to the New Frontiers 4 Announcement of Opportunity. If selected, CAESAR will fly to comet 67P/Churyumov-Gerasimenko (the same comet studied by ESA’s Rosetta mission) using solar electric propulsion. After some time in orbit around 67P collecting and analyzing images of 67P, a location for collecting a sample will be determined. Up to three “touch-and-go” maneuvers, similar to NASA’s OSIRIS-REx mission, can be attempted with the requirement of collecting at least 80 g of comet sample. Once the sample has been collected, it will be stored in the Sample Containment Subsystem (SCS) and the comet volatiles will be transferred into the Gas Containment System (GCS) for the return cruise back to Earth. As CAESAR approaches Earth, the Sample Return Capsule (SRC), containing the GCS and SCS will separate from the spacecraft and return back to Earth. The sample will be recovered and placed into cold storage for future studies and investigations. CAESAR presents a number of thermal challenges including significantly different power configurations and orientation constraints throughout the mission as well as a large number of mechanisms and configurations that must function at very cold temperatures. The temperature requirements for preserving the sample also present a challenge. This paper presents some of the high level thermal requirements and describes how the CAESAR thermal design was driven by these requirements.
Long-term (2–3 months) batch U(VI) sorption-desorption experiments were conducted to understand the long-term sorption-desorption behavior of U(VI) in saprolite subsoils from Oak Ridge Field Research Center (ORFRC), Tennessee, which contained naturally occurring nanoporous goethite. Three subsoil samples containing a range of dithionite-citrate-bicarbonate (DCB) extractable Fe oxide content (7138, 11,161, and 22,582 mg Fe/kg) were used for the experiments. Sorption of 50 μM U(VI) to the subsoils in the presence of Ca 2+ and HCO 3 - at circumneutral pH occurred rapidly during the first 2 days, after which slow U(VI) sorption continued over 3 months. U(VI) desorption from the soils by 10 mM NaHCO 3 solution exhibited an initial fast desorption step during the first 24 h, followed by slower desorption over a week. Sorption of 50 μM U(VI) for 1 day to 3 months in the presence or absence of Ca 2+ consistently resulted in higher U(VI) sorption to saprolite soil with higher amount of nanoporous goethite, while desorption of U(VI) for 1 week to 2 months was consistently lower in saprolite soil with higher amount of nanoporous goethite. Saprolite subsoils containing higher amounts of nanoporous goethite exhibited more resistant U(VI) desorption, and the proportions of irreversible U(VI) sorption increased with longer residence time with soils. These results indicates that more U(VI) became bound to the internal surfaces of nanoporous iron oxides during long-term sorption. This study suggests that naturally occurring nanoporous goethite may exert a significant role in controlling the mobility and transport of U(VI) in historically contaminated sites that have existed over decades.
A new and complete GC–ICP-MS method is described for direct analysis of trace metals in a gas phase process stream. The proposed method is derived from standard analytical procedures developed for ICP-MS, which are regularly exercised in standard ICP-MS laboratories. In order to implement the method, a series of empirical factors were generated to calibrate detector response with respect to a known concentration of an internal standard analyte. Calibrated responses are ultimately used to determine the concentration of metal analytes in a gas stream using a semi-quantitative algorithm. The method was verified using a traditional gas injection from a GC sampling valve and a standard gas mixture containing either a 1 ppm Xe + Kr mix with helium balance or 100 ppm Xe with helium balance. Data collected for Xe and Kr gas analytes revealed that agreement of 6–20% with the actual concentration can be expected for various experimental conditions. To demonstrate the method using a relevant “unknown” gas mixture, experiments were performed for continuous 4 and 7 hour periods using a Hg-containing sample gas that was co-introduced into the GC sample loop with the xenon gas standard. System performance and detector response to the dilute concentration of the internal standard were pre-determined, which allowed semi-quantitative evaluation of the analyte. The calculated analyte concentrations varied during the course of the 4 hour experiment, particularly during the first hour of the analysis where the actual Hg concentration was under predicted by up to 72%. Calculated concentration improved to within 30–60% for data collected after the first hour of the experiment. Similar results were seen during the 7 hour test with the deviation from the actual concentration being 11–81% during the first hour and then decreasing for the remaining period. The method detection limit (MDL) was determined for the mercury by injecting the sample gas into the system following a period of equilibration. The MDL for Hg was calculated as 6.8 μg · m -3 . This work describes the first complete GC–ICP-MS method to directly analyze gas phase samples, and detailed sample calculations and comparisons to conventional ICP-MS methods are provided.
There is growing interest in reconstructing phylogenies from the copious amounts of genome sequencing projects that target related viral, bacterial or eukaryotic organisms. To facilitate the construction of standardized and robust phylogenies for disparate types of projects, we have developed a complete bioinformatic workflow, with a web-based component to perform phylogenetic and molecular evolutionary (PhaME) analysis from sequencing reads, draft assemblies or completed genomes of closely related organisms. Furthermore, the ability to incorporate raw data, including some metagenomic samples containing a target organism (e.g. from clinical samples with suspected infectious agents), shows promise for the rapid phylogenetic characterization of organisms within complex samples without the need for prior assembly.
High-throughput sequencing technologies have strongly impacted microbiology, providing a rapid and cost-effective way of generating draft genomes and exploring microbial diversity. However, sequences obtained from impure nucleic acid preparations may contain DNA from sources other than the sample. Those sequence contaminations are a serious concern to the quality of the data used for downstream analysis, causing misassembly of sequence contigs and erroneous conclusions. Therefore, the removal of sequence contaminants is a necessary and required step for all sequencing projects. We developed DeconSeq, a robust framework for the rapid, automated identification and removal of sequence contamination in longer-read datasets (150 bp mean read length). DeconSeq is publicly available as standalone and web-based versions. The results can be exported for subsequent analysis, and the databases used for the web-based version are automatically updated on a regular basis. DeconSeq categorizes possible contamination sequences, eliminates redundant hits with higher similarity to non-contaminant genomes, and provides graphical visualizations of the alignment results and classifications. Using DeconSeq, we conducted an analysis of possible human DNA contamination in 202 previously published microbial and viral metagenomes and found possible contamination in 145 (72%) metagenomes with as high as 64% contaminating sequences. This new framework allows scientists to automatically detect and efficiently remove unwanted sequence contamination from their datasets while eliminating critical limitations of current methods. DeconSeq’s web interface is simple and user-friendly. The standalone version allows offline analysis and integration into existing data processing pipelines. DeconSeq’s results reveal whether the sequencing experiment has succeeded, whether the correct sample was sequenced, and whether the sample contains any sequence contamination from DNA preparation or host. In addition, the analysis of 202 metagenomes demonstrated significant contamination of the non-human associated metagenomes, suggesting that this method is appropriate for screening all metagenomes. DeconSeq is available at http://deconseq.sourceforge.net/.
SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased from the previous surface sample. The Tank 38H sub-surface sample shows changes in concentration for soluble species in the solution with some increasing and some decreasing. The current Tank 38H sub-surface sample contains less sludge solids than the previous sample based on visual appearance. The small differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate only minimal stratification of solution species within the tank.
SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased slightly from the previous surface sample. The Tank 38H sub-surface sample shows changes in concentration for soluble species in the solution with some increasing and some decreasing. The current Tank 38H sub-surface sample contains more sludge solids than the previous sample based on visual appearance. The small differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate only minimal stratification of solution species within the tank. The Tank 43H surface and sub-surface samples are similar in composition to the previous samples. The similar solution compositions measured in the Tank 43H surface and sub-surface samples indicate a minimal stratification within the tank. The total uranium and plutonium in the current Tank 38H surface sample remains similar to the previous analysis. The Tank 38H sub-surface sample shows an increase in uranium and plutonium concentrations compared to the previous sample likely because of an increase in sludge solids in the current sample. The total uranium concentration in the two Tank 43H samples is essentially unchanged from previous sample results. The plutonium concentration in the Tank 43H surface sample is similar to the previous sample results while the plutonium in the Tank 43H sub-surface sample increased relative to the previous analysis. The sum of the major cations versus the sum of the major anions shows a difference of <10% for both samples from Tank 38H and for both samples from Tank 43H providing an indication of good data quality for the non-radioactive analytes in the samples. The silicon concentrations measured in the Tank 38H sub-surface sample increased compared with the previous sample results likely due to the presence of more sludge solids in the current sample. The Tank 38H surface sample silicon concentrations is similar to the previous sample results. The Tank 43H surface and sub-surface sample silicon concentrations both increased compared to the previous sample results. The samples analyzed from Tanks 38H and 43H show silicon concentrations ranging from 61.5 to 97.3 mg/L.
During the past years the CDF and D0 detectors have collected large amounts of data obtaining a relatively pure sample of pair-produced top quarks and a well understood sample containing singly-produced top quarks. These samples have been used for the precise measurement of the top quark properties, and have set stringent limits on new physics in the top sample. This reports presents the latest results from the CDF and D0 collaborations on the search for new physics within the top sample using an integrated data sample of up to 3.6 fb{sup -1}.
An orbiting sample capture and orientation system architecture for a Rendezvous and Orbiting Sample Capture System (ROCS) concept was developed to enable spacecraft based, in-orbit capture, orientation, and transfer of a Mars sample container into a containment vessel as part of a potential Mars Sample Return (MSR) campaign. An analysis of the system functions, requirements, interactions, and constraints was performed. A trade study was carried out on relevant technologies, and a set of evaluation criteria was developed to help determine the most feasible concepts for implementation. The Mars Capture and Re-orientation for the potential Next Mars Orbiter (MACARONE) concept is proposed as a promising system architecture for the ROCS Capture and Orient Module (COM). The concept uses a sliding trap door for Orbiting Sample (OS) capture, a Motorized Cups Mechanism for OS orientation, and a 2 DOF Turret Arm with a paddle for transferring the OS into a containment vessel. This approach facilitates modularity, development flexibility, test-ability in a 1G environment, analyze-ability without the need to simulate or test for 0G contact dynamics, ability to encapsulate potential dust surrounding the OS, and ability to be ejected to reduce the probability of Earth exposure to non-sterilized Mars material.
We have previously detected VZV in healthy astronauts both during spaceflight and shortly after landing. Herein, we show that VZV shed in seropositive astronauts is infectious. A total of 40 saliva samples were obtained from each of the 3 astronauts. From each astronaut, 14 samples were taken 109 to 133 days before liftoff, 1 sample was taken every day during 12 days in space, and one sample was taken for 14 consecutive days beginning the second day after landing. Quantitative PCR was used to detect VZV DNA in saliva. None of 42 preflight saliva samples contained VZV DNA. VZV DNA was detected in saliva from 2 of 3 astronauts. In 1 astronaut, 6 of 12 samples obtained during space flight contained 120 to 2,500 copies of VZV DNA per ml; after landing, 1250 copies of VZV DNA were present on day 2, 45 copies on day 3, and 110 copies on day 5. All samples taken 6 to 15 days after touchdown were negative for VZV DNA. In the second astronaut, 5 of 12 samples obtained during space flight contained 18 to 650 copies of VZV DNA per ml; after landing, 560 copies of VZV DNA were present in saliva on day 2, 340 copies on day 4, 45 copies on day 5, and 23 copes on day 6. All samples taken 7 to 15 days after touchdown were negative for VZV DNA. Saliva taken 2 to 6 days after landing from all 3 astronauts was cultured on human fetal lung cells. After one subcultivation, a cytopathic effect developed in cultures inoculated with saliva from the two astronauts whose saliva contained VZV DNA. Both PCR and immunostaining identified the isolates to be VZV and not HSV-1. Importantly, the astronaut in whom no VZV was detected had a history of zoster 9 years earlier. It is possible that a boost in cell-mediated immunity to VZV which is known to develop after zoster protected him from subclinical reactivation. The genotype of the two VZV isolates was determined by VZV ORF22-based PCR/sequencing along with FRET-based PCR assays that target specific nucleotide polymorphisms. Both VZV isolates were found to be the European genotype which also contained a rare MspI restriction enodnuclease site in VZV ORF62 at position 107,252. These findings extend our previous demonstration of VZV DNA in saliva of astronauts by showing that infectious VZV is also present. Thus, like HSV-1 and HSV-2, VZV can reactivate and shed infectious virus in the absence of clinical disease.
Explore the source record for details and available documents.