Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPUTER ANIMATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A Longitudinal Evaluation of Partial Lung Irradiation in Mice by Using a Dedicated Image-Guided Small Animal Irradiator

Purpose: In lung cancer radiation therapy, the dose constraints are determined mostly by healthy lung toxicity. Preclinical microirradiators are a new tool to evaluate treatment strategies closer to clinical irradiation devices. In this study, we quantified local changes in lung density symptomatic of radiation-induced lung fibrosis (RILF) after partial lung irradiation in mice by using a precision image-guided small animal irradiator integrated with micro-computed tomography (CT) imaging. Methods and Materials: C57BL/6 adult male mice (n=76) were divided into 6 groups: a control group (0 Gy) and groups irradiated with a single fraction of 4, 8, 12, 16, or 20 Gy using 5-mm circular parallel-opposed fields targeting the upper right lung. A Monte Carlo model of the small animal irradiator was used for dose calculations. Following irradiation, all mice were imaged at regular intervals over 39 weeks (10 time points total). Nonrigid deformation was used to register the initial micro-CT scan to all subsequent scans. Results: Significant differences could be observed between the 3 highest (>10 Gy) and 3 lowest irradiation (<10 Gy) dose levels. A mean difference of 120 ± 10 HU between the 0- and 20-Gy groups was observed at week 39. RILF was found to be spatially limited to the irradiated portion of the lung. Conclusions: The data suggest that the severity of RILF in partial lung irradiation compared to large field irradiation in mice for the same dose is reduced, and therefore higher doses can be tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using dorsal surface for individual identification of dairy calves through 3D deep learning algorithms

Advances in machine learning techniques have allowed the development of computer vision systems (CVS) that can accurately predict several phenotypes of interest for livestock operations. In this context, 3D images taken from a top-down view are particularly useful for estimating body condition score, growth development, and body biometrics in cattle. Frequently, such CVS rely on identification (ID) systems, such as electronic tags, as a way to match animal ID and the predicted phenotype. However, the same 3D images used to predict body weight and other animal biometrics could be adopted for animal recognition as well. Such alternative would optimize CVS to recognize animal ID and monitor growth development simultaneously while leveraging the same hardware infrastructure. Furthermore, this strategy could be used to recognize animals with similar color patterns. Nonetheless, growing animals are continuously changing body shape, which could limit its use as an invariant feature for pattern recognition. Thus, the objectives of this study were: (1) to compare algorithms for different 3D object representations to identify individual animals; and (2) to evaluate how short-term changes in body shape due to animal growth affect the predictive performance of these algorithms. For objective 1, the algorithms were trained (n = 4,558) and tested (n = 1,139) using images from 38 Holstein calves. For objective 2, we designed three different experiments using images (n = 2,347) from five Holstein calves taken over six weeks during their growing period, always training and testing on different weeks. Each experiment evaluated how changing a different parameter of the image capturing procedure affected the predictive ability of the trained algorithms. In the first experiment, we varied the total number of images per animal in the training set; in the second experiment, we varied the number of weeks while keeping a fixed number of images in the training set; and in the third experiment, we skipped weeks between images in the training and test sets. The F 1 score for objective (1) was up to 0.804 when testing with the last frames of each video, and up to 0.959 when using random frames for testing. For objective (2), the F 1 score was up to 0.947 for the first experiment when using 130 images per animal; up to 0.979 for the second experiment when using all five weeks; and up to 0.917 when not skipping weeks between training and testing. In conclusion, these results show that deep learning algorithms can be used to identify individual animals through their dorsal area 3D surfaces, and, from our experiments using calves in their growing period, that they are robust enough to account for changes in body shape and size, making them a promising tool for animal recognition during growth.

3D neural networks↗

Modeling the behavioral substrates of associate learning and memory - Adaptive neural models

Three adaptive single-neuron models based on neural analogies of behavior modification episodes are proposed, which attempt to bridge the gap between psychology and neurophysiology. The proposed models capture the predictive nature of Pavlovian conditioning, which is essential to the theory of adaptive/learning systems. The models learn to anticipate the occurrence of a conditioned response before the presence of a reinforcing stimulus when training is complete. Furthermore, each model can find the most nonredundant and earliest predictor of reinforcement. The behavior of the models accounts for several aspects of basic animal learning phenomena in Pavlovian conditioning beyond previous related models. Computer simulations show how well the models fit empirical data from various animal learning paradigms.

Lee, Chuen-Chien↗

Acoustic radiation force due to arbitrary incident fields on spherical particles in soft tissue

Acoustic radiation force is of interest in a wide variety of biomedical applications ranging from tissue characterization (e.g. elastography) to tissue treatment (e.g. high intensity focused ultrasound, kidney stone fragment removal). As tissue mechanical properties are reliable indicators of tissue health, the former is the focus of the present contribution. This is accomplished through an investigation of the acoustic radiation force on a spherical scatterer embedded in tissue. Properties of both the scatterer and the surrounding tissue are important in determining the magnitude and the direction of the force. As these properties vary, the force computation shows changes in magnitude and direction, which may enable more accurate noninvasive determination of tissue properties.

42 ENGINEERING↗

Aeroelastic, CFD, and Dynamics Computation and Optimization for Buffet and Flutter Applications

Accomplishments achieved during the reporting period are listed. These accomplishments included 6 papers published in various journals or presented at various conferences; 1 abstract submitted to a technical conference; production of 2 animated movies; and a proposal for use of the National Aerodynamic Simulation Facility at NASA Ames Research Center for further research. The published and presented papers and animated movies addressed the following topics: aeroelasticity, computational fluid dynamics, structural dynamics, wing and tail buffet, vortical flow interactions, and delta wings.

Kandil, Osama A.↗

New Approach Methodology for Assessing Inhalation Risks of a Contact Respiratory Cytotoxicant: Computational Fluid Dynamics-Based Aerosol Dosimetry Modeling for Cross-Species and In Vitro Comparisons

Regulatory agencies are considering alternative approaches to assessing inhalation toxicity that utilizes in vitro studies with human cells and in silico modeling in lieu of additional animal studies. In support of this goal, computational fluid-particle dynamics models were developed to estimate site-specific deposition of inhaled aerosols containing the fungicide, chlorothalonil, in the rat and human for comparisons to prior rat inhalation studies and new human in vitro studies. Under bioassay conditions, the deposition was predicted to be greatest at the front of the rat nose followed by the anterior transitional epithelium and larynx corresponding to regions most sensitive to local contact irritation and cytotoxicity. For humans, simulations of aerosol deposition covering potential occupational or residential exposures (1–50 µm diameter) were conducted using nasal and oral breathing. Aerosols in the 1–5 µm range readily penetrated the deep region of the human lung following both oral and nasal breathing. Under actual use conditions (aerosol formulations >10 µm), the majority of deposited doses were in the upper conducting airways. Beyond the nose or mouth, the greatest deposition in the pharynx, larynx, trachea, and bronchi was predicted for aerosols in the 10–20 µm size range. Only small amounts of aerosols >20 µm penetrated past the pharyngeal region. Using the ICRP clearance model, local retained tissue dose metrics including maximal concentrations and areas under the curve were calculated for each airway region following repeated occupational exposures. These results are directly comparable with benchmark doses from in vitro toxicity studies in human cells leading to estimated human equivalent concentrations that reduce the reliance on animals for risk assessments.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Blade loss transient dynamics analysis, volume 2. Task 2: TETRA 2 user's manual

This is the user's manual for the TETRA 2 Computer Code, a program developed in the NASA-Lewis Blade Loss Program. TETRA 2 calculates a turbine engine's dynamic structural response from applied stimuli. The calculation options are: (1) transient response; and (2) steady state forced response. Based on the method of modal syntheses, the program allows the use of linear, as well as nonlinear connecting elements. Both transient and steady state options can include: flexible Bladed Disk Module, and Nonlinear Connecting Elements (including deadband, hardening/softening spring). The transient option has the additional capability to calculate response with a squeeze film bearing module. TETRA 2 output is summarized in a plotfile which permits post processing such as FFT or graphical animation with the proper software and computer equipment.

Black, Gerald↗

Structural and functional analyses of human cerebral cortex using a surface-based atlas

We have analyzed the geometry, geography, and functional organization of human cerebral cortex using surface reconstructions and cortical flat maps of the left and right hemispheres generated from a digital atlas (the Visible Man). The total surface area of the reconstructed Visible Man neocortex is 1570 cm2 (both hemispheres), approximately 70% of which is buried in sulci. By linking the Visible Man cerebrum to the Talairach stereotaxic coordinate space, the locations of activation foci reported in neuroimaging studies can be readily visualized in relation to the cortical surface. The associated spatial uncertainty was empirically shown to have a radius in three dimensions of approximately 10 mm. Application of this approach to studies of visual cortex reveals the overall patterns of activation associated with different aspects of visual function and the relationship of these patterns to topographically organized visual areas. Our analysis supports a distinction between an anterior region in ventral occipito-temporal cortex that is selectively involved in form processing and a more posterior region (in or near areas VP and V4v) involved in both form and color processing. Foci associated with motion processing are mainly concentrated in a region along the occipito-temporal junction, the ventral portion of which overlaps with foci also implicated in form processing. Comparisons between flat maps of human and macaque monkey cerebral cortex indicate significant differences as well as many similarities in the relative sizes and positions of cortical regions known or suspected to be homologous in the two species.

NASA Discipline Neuroscience↗

WE-DE-201-12: Thermal and Dosimetric Properties of a Ferrite-Based Thermo-Brachytherapy Seed

Purpose: The novel thermo-brachytherapy (TB) seed provides a simple means of adding hyperthermia to LDR prostate permanent implant brachytherapy. The high blood perfusion rate (BPR) within the prostate motivates the use of the ferrite and conductive outer layer design for the seed cores. We describe the results of computational analyses of the thermal properties of this ferrite-based TB seed in modelled patient-specific anatomy, as well as studies of the interseed and scatter (ISA) effect. Methods: The anatomies (including the thermophysical properties of the main tissue types) and seed distributions of 6 prostate patients who had been treated with LDR brachytherapy seeds were modelled in the finite element analysis software COMSOL, using ferrite-based TB and additional hyperthermia-only (HT-only) seeds. The resulting temperature distributions were compared to those computed for patient-specific seed distributions, but in uniform anatomy with a constant blood perfusion rate. The ISA effect was quantified in the Monte Carlo software package MCNP5. Results: Compared with temperature distributions calculated in modelled uniform tissue, temperature distributions in the patient-specific anatomy were higher and more heterogeneous. Moreover, the maximum temperature to the rectal wall was typically ∼1 °C greater for patient-specific anatomy than for uniform anatomy. The ISA effect of the TB and HT-only seeds caused a reduction in D90 similar to that found for previously-investigated NiCu-based seeds, but of a slightly smaller magnitude. Conclusion: The differences between temperature distributions computed for uniform and patient-specific anatomy for ferrite-based seeds are significant enough that heterogeneous anatomy should be considered. Both types of modelling indicate that ferrite-based seeds provide sufficiently high and uniform hyperthermia to the prostate, without excessively heating surrounding tissues. The ISA effect of these seeds is slightly less than that for the previously-presented NiCu-based seeds.

07 ISOTOPE AND RADIATION SOURCES↗

Computer-generated imagery for 4-D meteorological data

The University of Wisconsin-Madison Space Science and Engineering Center is developing animated stereo display terminals for use with McIDAS (Man-computer Interactive Data Access System). This paper describes image-generation techniques which have been developed to take maximum advantage of these terminals, integrating large quantities of four-dimensional meteorological data from balloon and satellite soundings, satellite images, Doppler and volumetric radar, and conventional surface observations. The images have been designed to use perspective, shading, hidden-surface removal, and transparency to augment the animation and stereo-display geometry. They create an illusion of a moving three-dimensional model of the atmosphere. This paper describes the design of these images and a number of rules of thumb for generating four-dimensional meteorological displays.

Hibbard, William L.↗

A heterogeneous computing environment for simulating astrophysical fluid flows

In the Concurrent Computing Laboratory in the Department of Physics and Astronomy at Louisiana State University we have constructed a heterogeneous computing environment that permits us to routinely simulate complicated three-dimensional fluid flows and to readily visualize the results of each simulation via three-dimensional animation sequences. An 8192-node MasPar MP-1 computer with 0.5 GBytes of RAM provides 250 MFlops of execution speed for our fluid flow simulations. Utilizing the parallel virtual machine (PVM) language, at periodic intervals data is automatically transferred from the MP-1 to a cluster of workstations where individual three-dimensional images are rendered for inclusion in a single animation sequence. Work is underway to replace executions on the MP-1 with simulations performed on the 512-node CM-5 at NCSA and to simultaneously gain access to more potent volume rendering workstations.

Cazes, J.↗

IRS SCAN-MAPPING OF THE WASP-WAIST NEBULA (IRAS 16253-2429). I. DERIVATION OF SHOCK CONDITIONS FROM H{sub 2} EMISSION AND DISCOVERY OF 11.3 {mu}m PAH ABSORPTION

The outflow driven by the Class 0 protostar, IRAS 16253-2429, is associated with bipolar cavities visible in scattered mid-infrared light, which we refer to as the Wasp-Waist Nebula. InfraRed Spectometer (IRS) scan mapping with the Spitzer Space Telescope of a {approx}1' x 2' area centered on the protostar was carried out. The outflow is imaged in six pure rotational (0-0 S(2) through 0-0 S(7)) H{sub 2} lines, revealing a distinct, S-shaped morphology in all maps. A source map in the 11.3 {mu}m polycyclic aromatic hydrocarbon (PAH) feature is presented in which the protostellar envelope appears in absorption. This is the first detection of absorption in the 11.3 {mu}m PAH feature. Spatially resolved excitation analysis of positions in the blue- and redshifted outflow lobes, with extinction-corrections determined from archival Spitzer 8 {mu}m imaging, shows remarkably constant temperatures of {approx}1000 K in the shocked gas. The radiated luminosity in the observed H{sub 2} transitions is found to be 1.94 {+-} 0.05 x 10{sup -5} L{sub sun} in the redshifted lobe and 1.86 {+-} 0.04 x 10{sup -5} L{sub sun} in the blueshifted lobe. These values are comparable to the mechanical luminosity of the flow. By contrast, the mass of hot (T {approx} 1000 K) H{sub 2} gas is 7.95 {+-} 0.19 x 10{sup -7} M{sub sun} in the redshifted lobe and 5.78 {+-} 0.17 x 10{sup -7} M{sub sun} in the blueshifted lobe. This is just a tiny fraction, of order 10{sup -3}, of the gas in the cold (30 K), swept-up gas mass derived from millimeter CO observations. The H{sub 2} ortho/para ratio of 3:1 found at all mapped points in this flow suggests previous passages of shocks through the gas. Comparison of the H{sub 2} data with detailed shock models of Wilgenbus et al. shows the emitting gas is passing through Jump (J-type) shocks. Pre-shock densities of 10{sup 4} cm{sup -3{<=}} n {sub H{<=}} 10{sup 5} cm{sup -3} are inferred for the redshifted lobe and n {sub H{<=}} 10{sup 3} cm{sup -3} for the blueshifted lobe. Shock velocities are 5 km s{sup -1} {<=} v{sub s} {<=} 10 km s{sup -1} for the redshifted gas and v{sub s} = 10 km s{sup -1} for the blueshifted gas. Initial transverse (to the shock) magnetic field strengths for the redshifted lobe are in the range 10-32 {mu}G, and just 3 {mu}G for the blueshifted lobe. A cookbook for using the CUBISM contributed software for IRS spectral mapping data is presented in the Appendix.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-90: MRI-Based Treatment Simulation and Patient Setup for Radiation Therapy of Brain Cancer

Purpose: Traditional radiation therapy of cancer is heavily dependent on CT. CT provides excellent depiction of the bones but lacks good soft tissue contrast, which makes contouring difficult. Often, MRIs are fused with CT to take advantage of its superior soft tissue contrast. Such an approach has drawbacks. It is desirable to perform treatment simulation entirely based on MRI. To achieve MR-based simulation for radiation therapy, bone imaging is an important challenge because of the low MR signal intensity from bone due to its ultra-short T2 and T1, which presents difficulty for both dose calculation and patient setup in terms of digitally reconstructed radiograph (DRR) generation. Current solutions will either require manual bone contouring or multiple MR scans. We present a technique to generate DRR using MRI with an Ultra Short Echo Time (UTE) sequence which is applicable to both OBI and ExacTrac 2D patient setup. Methods: Seven brain cancer patients were scanned at 1.5 Tesla using a radial UTE sequence. The sequence acquires two images at two different echo times. The two images were processed using in-house software. The resultant bone images were subsequently loaded into commercial systems to generate DRRs. Simulation and patient clinical on-board images were used to evaluate 2D patient setup with MRI-DRRs. Results: The majority bones are well visualized in all patients. The fused image of patient CT with the MR bone image demonstrates the accuracy of automatic bone identification using our technique. The generated DRR is of good quality. Accuracy of 2D patient setup by using MRI-DRR is comparable to CT-based 2D patient setup. Conclusion: This study shows the potential of DRR generation with single MR sequence. Further work will be needed on MR sequence development and post-processing procedure to achieve robust MR bone imaging for other human sites in addition to brain.

60 APPLIED LIFE SCIENCES↗

SU-E-J-263: Dosimetric Analysis On Breast Brachytherapy Based On Deformable Image Registration

Purpose: To quantitatively compare and evaluate the dosimetry difference between breast brachytherapy protocols with different fractionation using deformable image registration. Methods: The accumulative dose distribution for multiple breast brachytherapy patients using four different applicators: Contura, Mammosite, Savi, and interstitial catheters, under two treatment protocols: 340cGy by 10 fractions in 5 days and 825cGy by 3 fractions in 2days has been reconstructed using a two stage deformable image registration approach. For all patients, daily CT was acquired with the same slice thickness (2.5mm). In the first stage, the daily CT images were rigidly registered to the initial planning CT using the registration module in Eclipse (Varian) to align the applicators. In the second stage, the tissues surrounding the applicator in the rigidly registered daily CT image were non-rigidly registered to the initial CT using a combination of image force and the local constraint that enforce zero normal motion on the surface of the applicator, using a software developed in house. We calculated the dose distribution in the daily CTs and deformed them using the final registration to convert into the image domain of the initial planning CT. The accumulative dose distributions were evaluated by dosimetry parameters including D90, V150 and V200, as well as DVH. Results: Dose reconstruction results showed that the two day treatment has a significant dosimetry improvement over the five day protocols. An average daily drop of D90 at 1.3% of the prescription dose has been observed on multiple brachytherapy patients. There is no significant difference on V150 and V200 between those two protocols. Conclusion: Brachytherapy with higher fractional dose and less fractions has an improved performance on being conformal to the dose distribution in the initial plan. Elongated brachytherapy treatments need to consider the dose uncertainty caused by the temporal changes of the soft tissue.

60 APPLIED LIFE SCIENCES↗

SU-E-J-114: A Practical Hybrid Method for Improving the Quality of CT-CBCT Deformable Image Registration for Head and Neck Radiotherapy

Purpose: Accurate deformable image registration (DIR) between CT and CBCT in H&N is challenging. In this study, we propose a practical hybrid method that uses not only the pixel intensities but also organ physical properties, structure volume of interest (VOI), and interactive local registrations. Methods: Five oropharyngeal cancer patients were selected retrospectively. For each patient, the planning CT was registered to the last fraction CBCT, where the anatomy difference was largest. A three step registration strategy was tested; Step1) DIR using pixel intensity only, Step2) DIR with additional use of structure VOI and rigidity penalty, and Step3) interactive local correction. For Step1, a public-domain open-source DIR algorithm was used (cubic B-spline, mutual information, steepest gradient optimization, and 4-level multi-resolution). For Step2, rigidity penalty was applied on bony anatomies and brain, and a structure VOI was used to handle the body truncation such as the shoulder cut-off on CBCT. Finally, in Step3, the registrations were reviewed on our in-house developed software and the erroneous areas were corrected via a local registration using level-set motion algorithm. Results: After Step1, there were considerable amount of registration errors in soft tissues and unrealistic stretching in the posterior to the neck and near the shoulder due to body truncation. The brain was also found deformed to a measurable extent near the superior border of CBCT. Such errors could be effectively removed by using a structure VOI and rigidity penalty. The rest of the local soft tissue error could be corrected using the interactive software tool. The estimated interactive correction time was approximately 5 minutes. Conclusion: The DIR using only the image pixel intensity was vulnerable to noise and body truncation. A corrective action was inevitable to achieve good quality of registrations. We found the proposed three-step hybrid method efficient and practical for CT/CBCT registrations in H&N. My department receives grant support from Industrial partners: (a) Varian Medical Systems, Palo Alto, CA, and (b) Philips HealthCare, Best, Netherlands.

60 APPLIED LIFE SCIENCES↗

SU-E-J-115: Correlation of Displacement Vector Fields Calculated by Deformable Image Registration Algorithms with Motion Parameters of CT Images with Well-Defined Targets and Controlled-Motion

Purpose: To investigate correlation of displacement vector fields (DVF) calculated by deformable image registration algorithms with motion parameters in helical axial and cone-beam CT images with motion artifacts. Methods: A mobile thorax phantom with well-known targets with different sizes that were made from water-equivalent material and inserted in foam to simulate lung lesions. The thorax phantom was imaged with helical, axial and cone-beam CT. The phantom was moved with a cyclic motion with different motion amplitudes and frequencies along the superior-inferior direction. Different deformable image registration algorithms including demons, fast demons, Horn-Shunck and iterative-optical-flow from the DIRART software were used to deform CT images for the phantom with different motion patterns. The CT images of the mobile phantom were deformed to CT images of the stationary phantom. Results: The values of displacement vectors calculated by deformable image registration algorithm correlated strongly with motion amplitude where large displacement vectors were calculated for CT images with large motion amplitudes. For example, the maximal displacement vectors were nearly equal to the motion amplitudes (5mm, 10mm or 20mm) at interfaces between the mobile targets lung tissue, while the minimal displacement vectors were nearly equal to negative the motion amplitudes. The maximal and minimal displacement vectors matched with edges of the blurred targets along the Z-axis (motion-direction), while DVF’s were small in the other directions. This indicates that the blurred edges by phantom motion were shifted largely to match with the actual target edge. These shifts were nearly equal to the motion amplitude. Conclusions: The DVF from deformable-image registration algorithms correlated well with motion amplitude of well-defined mobile targets. This can be used to extract motion parameters such as amplitude. However, as motion amplitudes increased, image artifacts increased significantly and that limited image quality and poor correlation between the motion amplitude and DVF was obtained.

60 APPLIED LIFE SCIENCES↗

SU-E-J-166: Sensitivity of Clinically Relevant Dosimetric Parameters to Contouring Uncertainty During Post Implant Dosimetry of Prostate Permanent Seed Implants

Purpose: There is a strong evidence relating post-implant dosimetry for permanent seed prostate brachytherpy to local control rates. The delineation of the prostate on CT images, however, represents a challenge as it is difficult to confidently identify the prostate borders from soft tissue surrounding it. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to prostate contouring uncertainty. Methods: The post-implant CT images and plans for a cohort of 43 patients, who have received I–125 permanent prostate seed implant in our centre, were exported to MIM Symphony LDR brachytherapy treatment planning system (MIM Software Inc., Cleveland, OH). The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00mm, ±2.00mm, ±3.00mm, ±4.00mm and ±5.00mm (±0.01mm). The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: The mean value of V100 and D90 was obtained as 92.3±8.4% and 108.4±12.3% respectively (Rx=145Gy). V100 was reduced by −3.2±1.5%, −7.2±3.0%, −12.8±4.0%, −19.0±4.8%, − 25.5±5.4% for expanded contours of prostate with margins of +1mm, +2mm, +3mm, +4mm, and +5mm, respectively, while it was increased by 1.6±1.2%, 2.4±2.4%, 2.7±3.2%, 2.9±4.2%, 2.9±5.1% for the contracted contours. D90 was reduced by −6.9±3.5%, −14.5±6.1%, −23.8±7.1%, − 33.6±8.5%, −40.6±8.7% and increased by 4.1±2.6%, 6.1±5.0%, 7.2±5.7%, 8.1±7.3% and 8.1±7.3% for the same set of contours. Conclusion: Systematic expansion errors of more than 1mm may likely render a plan sub-optimal. Conversely contraction errors may Result in labeling a plan likely as optimal. The use of MRI images to contour the prostate should results in better delineation of prostate organ which increases the predictive value of post-op plans. Since observers tend to overestimate the prostate volume on CT, compared with MRI, the impact of the contouring uncertainty on V100 and D90 fortunately, has a conservative effect of underestimating the prostate coverage.

60 APPLIED LIFE SCIENCES↗

SU-E-T-388: Evaluation of Electronic Brachytherapy Dose Distributions in Tissue Equivalent Materials

Purpose: To study the measured and calculated dose distributions for electronic brachytherapy (EBT) in various tissue equivalent homogenous materials. Methods: Calculated dose distributions in water were generated using published TG-43 parameters in Varian BrachyVision software for a 50 kVp, 50 cm Xoft source. Dose distributions were measured within a 3D-scanning tank using dosimeters including: PTW 0.125 cc, pin-point, and parallel-plate ion chambers, Sun Nuclear “Edge” diode and Gafchromic EBT3 film. Multi-channel film dosimetry was used in film analysis. EBT3 film curves were calibrated via radial dose comparison to both independently measured and published data. The resulting film calibration was utilized to measure dose distributions created by titanium filtered source utilized in clinical brachytherapy applications. Data was collected within homogenous PMMA, vinyl, polystyrene, paraffin, and water-equivalent plastic phantoms. Results: Ion-chamber data was corrected to effective points of measurement and normalized prior to comparison between calculated and measured dose distributions. Measurements made in water and water equivalent materials compared well with results from treatment planning software. The maximum percent differences (relative to water) observed between 1 cm and 3.5 cm depth from source for each of the phantom materials are as follows: PMMA 35%, polystyrene 41%, plastic-water 23%, vinyl 115%, and paraffin 46%. Conclusion: The increased probability of photoelectric interactions occurring within the patient during electronic brachytherapy will emphasize the radiological differences between varying human tissues in dose deposition. These differences can Result in clinically significant dose perturbations and it is therefore recommended to move to a model based dose calculation, as outlined in TG-186, to improve the dosimetric accuracy of low energy EBT.

60 APPLIED LIFE SCIENCES↗