Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPARATIVE TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

3D Printing of Liquid Crystal Elastomer Foams for Enhanced Energy Dissipation Under Mechanical Insult

Polymer foams are an essential class of lightweight materials used to protect assets against mechanical insults, such as shock and vibration. Two features are important to enhance their energy absorption characteristics: the foam structure and the matrix phase mechanical behavior. This study investigates novel approaches to control both of these features to enhance the energy absorption capability of flexible lattice foams. First, we consider 3D printing via digital light processing (DLP) as a method to control the foam mesostructure across a suite of periodic unit cells. Second, we introduce an additional energy dissipation mechanism in the solid matrix phase material by 3D printing the lattice foams with polydomain liquid crystal elastomer (LCE), which undergo a mechanically induced phase transition under large strains. This phase transition is associated with LC mesogen rotation and alignment and provides a second mechanism for mechanical energy dissipation in addition to the viscoelastic relaxation of the polymer network. Here, we contrast the 3D printed LCE lattices with conventional, thermomechanically near-equivalent elastomer lattice foams to quantify the energy-absorbing enhancement the LCE matrix phase provides. Under cyclic quasi-static uniaxial compression conditions, the LCE lattices show dramatically enhanced energy dissipation in uniaxial compression compared to the non-LCE equivalent foams printed with a commercially available photocurable elastomer resin. The lattice geometry also plays a prominent role in determining the energy dissipation ratio between the LCE and non-LCE foams. We show that when increasing the lattice connectivity, the foam deformation transitions from bending-dominated to stretching-dominated deformations, which generates higher axial strains in the struts and higher energy dissipation in the lattice foam, as stretching allows greater mesogen rotation than bending. The LCE foams demonstrate superior energy absorption during the repeated dynamic loading during drop testing compared with the non-LCE equivalent foams, demonstrating the potential of LCEs to enhance physical protection systems against mechanical impact.

3D printing↗

Dynamical Chaos in the Wisdom-Holman Integrator: Origins and Solutions

We examine the nonlinear stability of the Wisdom-Holman (WH) symplectic mapping applied to the integration of perturbed, highly eccentric (e-0.9) two-body orbits. We find that the method is unstable and introduces artificial chaos into the computed trajectories for this class of problems, unless the step size chosen 1s small enough that PeriaPse is always resolved, in which case the method is generically stable. This 'radial orbit instability' persists even for weakly perturbed systems. Using the Stark problem as a fiducial test case, we investigate the dynamical origin of this instability and argue that the numerical chaos results from the overlap of step-size resonances; interestingly, for the Stark-problem many of these resonances appear to be absolutely stable. We similarly examine the robustness of several alternative integration methods: a time-regularized version of the WH mapping suggested by Mikkola; the potential-splitting (PS) method of Duncan, Levison, Lee; and two original methods incorporating approximations based on Stark motion instead of Keplerian motion. The two fixed point problem and a related, more general problem are used to conduct a comparative test of the various methods for several types of motion. Among the algorithms tested, the time-transformed WH mapping is clearly the most efficient and stable method of integrating eccentric, nearly Keplerian orbits in the absence of close encounters. For test particles subject to both high eccentricities and very close encounters, we find an enhanced version of the PS method-incorporating time regularization, force-center switching, and an improved kernel function-to be both economical and highly versatile. We conclude that Stark-based methods are of marginal utility in N-body type integrations. Additional implications for the symplectic integration of N-body systems are discussed.

Rauch, Kevin P.↗

Comparison of Wind-Tunnel and Flight Unsteady Pressure Stochastic Characteristics for the Space Launch System Artemis I Flight

Over the course of more than ten years, numerous wind-tunnel tests have been conducted to acquire data for characterizing the unsteady pressure environments expected to act on the Space Launch System Block 1 crew launch vehicle during ascent. These wind-tunnel tests of highly-instrumented rigid models are the current standard for the estimation of unsteady environments. Following the successful launch of the Artemis I mission, the extensive flight data acquired can be analyzed to evaluate the accuracy of unsteady pressure environments predicted in subscale wind-tunnel testing in comparison to the flight test data. In this paper, analyses focusing on data from several Space Launch System wind-tunnel tests and the Artemis I flight test are presented, including assessments of test-to-test, tunnel-to-tunnel, and tunnel-to-flight stochastic characteristics and preflight modeling validity based on wind-tunnel testing. In general, the fluctuating pressure environments measured during the several preflight subscale wind-tunnel tests compare favorably and provide relatively accurate estimates of the environments measured during flight. Discrepancies in fluctuating magnitudes, spatial extent of regions of unsteadiness, and narrowband frequency peaks are noted in the multibody region aft of the solid rocket booster forward attachment to the core stage.

wind-tunnel↗

Comparison of Wind-Tunnel and Flight Unsteady Pressure Stochastic Characteristics for the Space Launch System Artemis I Flight

Over the course of more than ten years, numerous wind-tunnel tests have been conducted to acquire data for characterizing the unsteady pressure environments expected to act on the Space Launch System Block 1 crew launch vehicle during ascent. These wind-tunnel tests of highly-instrumented rigid models are the current standard for the estimation of unsteady environments. Following the successful launch of the Artemis I mission, the extensive flight data acquired can be analyzed to evaluate the accuracy of unsteady pressure environments predicted in subscale wind-tunnel testing in comparison to the flight test data. In this paper, analyses focusing on data from several Space Launch System wind-tunnel tests and the Artemis I flight test are presented, including assessments of test-to-test, tunnel-to-tunnel, and tunnel-to-flight stochastic characteristics and preflight modeling validity based on wind-tunnel testing. In general, the fluctuating pressure environments measured during the several preflight subscale wind-tunnel tests compare favorably and provide relatively accurate estimates of the environments measured during flight. Discrepancies in fluctuating magnitudes, spatial extent of regions of unsteadiness, and narrowband frequency peaks are noted in the multibody region aft of the solid rocket booster forward attachment to the core stage.

wind-tunnel↗

Development of a space activity suit

The development of a series of prototype space activity suit (SAS) assemblies is discussed. The SAS is a new type of pressure suit designed especially for extravehicular activity. It consists of a set of carefully tailored elastic fabric garments which have been engineered to supply sufficient counterpressure to the body to permit subjects to breath O2 at pressures up to 200 mm Hg without circulatory difficulty. A closed, positive pressure breathing system (PPBS) and a full bubble helmet were also developed to complete the system. The ultimate goal of the SAS is to improve the range of activity and decrease the energy cost of work associated with wearing conventional gas filled pressure suits. Results are presented from both laboratory (1 atmosphere) and altitude chamber tests with subjects wearing various SAS assemblies. In laboratory tests lasting up to three hours, the SAS was worn while subjects breathed O2 at pressures up to 170 mm Hg without developing physiological problems. The only physiological symptoms apparent were a moderate tachycardia related to breathing pressures above 130 mm Hg, and a small collection of edema fluid in the hands. Both problems were considered to be related to areas of under-pressurization by the garments. These problems, it is suggested, can ultimately be corrected by the development of new elastic fabrics and tailoring techniques. Energy cost of activity, and mobility and dexterity of subjects in the SAS, were found to be superior to those in comparable tests on subjects in full pressure suits.

Annis, J. F.↗

Experimental investigation of a moving averaging algorithm for motion perpendicular to the leaf travel direction in dynamic MLC target tracking

Purpose: In dynamic multileaf collimator (MLC) motion tracking with complex intensity-modulated radiation therapy (IMRT) fields, target motion perpendicular to the MLC leaf travel direction can cause beam holds, which increase beam delivery time by up to a factor of 4. As a means to balance delivery efficiency and accuracy, a moving average algorithm was incorporated into a dynamic MLC motion tracking system (i.e., moving average tracking) to account for target motion perpendicular to the MLC leaf travel direction. The experimental investigation of the moving average algorithm compared with real-time tracking and no compensation beam delivery is described. Methods: The properties of the moving average algorithm were measured and compared with those of real-time tracking (dynamic MLC motion tracking accounting for both target motion parallel and perpendicular to the leaf travel direction) and no compensation beam delivery. The algorithm was investigated using a synthetic motion trace with a baseline drift and four patient-measured 3D tumor motion traces representing regular and irregular motions with varying baseline drifts. Each motion trace was reproduced by a moving platform. The delivery efficiency, geometric accuracy, and dosimetric accuracy were evaluated for conformal, step-and-shoot IMRT, and dynamic sliding window IMRT treatment plans using the synthetic and patient motion traces. The dosimetric accuracy was quantified via a {gamma}-test with a 3%/3 mm criterion. Results: The delivery efficiency ranged from 89 to 100% for moving average tracking, 26%-100% for real-time tracking, and 100% (by definition) for no compensation. The root-mean-square geometric error ranged from 3.2 to 4.0 mm for moving average tracking, 0.7-1.1 mm for real-time tracking, and 3.7-7.2 mm for no compensation. The percentage of dosimetric points failing the {gamma}-test ranged from 4 to 30% for moving average tracking, 0%-23% for real-time tracking, and 10%-47% for no compensation. Conclusions: The delivery efficiency of moving average tracking was up to four times higher than that of real-time tracking and approached the efficiency of no compensation for all cases. The geometric accuracy and dosimetric accuracy of the moving average algorithm was between real-time tracking and no compensation, approximately half the percentage of dosimetric points failing the {gamma}-test compared with no compensation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Temperature High Vacuum Mechanical Property Assessment of Zirconium Nuclear Fuel Cladding

This report presents the mechanical characterization of a specific Zry-4 cladding batch serving as the foundation for a diverse range of fuel performance research at Oak Ridge National Laboratory (ORNL). This effort supports research needs for the U.S. Department of Energy (DOE), particularly regarding evaluating accident tolerant fuel (ATF) cladding coating concepts, expanding understanding of cladding response to loss-of-coolant accidents (LOCA) transients, refining post-critical heat flux (CHF) limits (t@T), and upcoming irradiation campaigns. The central objective was to define the baseline performance of the substrate Zircaloy-4 (Zry-4) material leveraged across ORNL Advanced Fuel Campaign (AFC) efforts through controlled high-temperature vacuum tensile testing. This work begins to address gaps in existing models where implementation based on nominal heat-treatment labels, such as stress relief annealed (SRA), often fail to capture the interplay of recovery, recrystallization, and grain growth. To quantify this, data was benchmarked against the Pacific Northwest National Laboratory (PNNL) stress strain model to determine where this material falls in comparison to assumed values for materials in the same heat treatment regime. Analysis of the tensile data revealed that this specific SRA batch exhibits a transitional microstructural state best described by an effective cold-work (CW) parameter of 0.09, diverging from the previous estimation of 0.5 for SRA materials. Additionally, comparative testing of Cr coated specimens demonstrated no distinct difference in axial strength relative to the bare substrate. This suggests that the strengthening benefits of Cr coatings observed in burst scenarios are driven by residual stress mechanisms acting solely in the hoop direction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial Report of a Prospective Dosimetric and Clinical Feasibility Trial Demonstrates the Potential of Protons to Increase the Therapeutic Ratio in Breast Cancer Compared With Photons

Purpose: To compare dosimetric endpoints between proton therapy (PT) and conventional radiation and determine the feasibility of PT for regional nodal irradiation (RNI) in women with breast cancer. Methods and Materials: From 2012 to 2014, 18 women (stage IIA-IIIB) requiring RNI prospectively enrolled on a pilot study. Median age was 51.8 years (range, 42-73 years). The cohort included breast-conserving therapy (BCT) and mastectomy patients and right- and left-sided cancers. Treatment targets and organs at risk were delineated on computed tomography scans, and PT and conventional plans were developed. Toxicity was prospectively recorded using Common Terminology Criteria for Adverse Events version 4.0. A Wilcoxon signed-rank sum test compared the dose-volume parameters. The primary endpoint was a reduction in cardiac V5. Results: Median follow-up was 20 months (range, 2-31 months). For all patients, the PT plan better met the dosimetric goals and was used for treatment. Proton therapy alone was used for 10 patients (9 postmastectomy, 1 after BCT) and combined proton–photon in 8 (6 BCT, 2 postmastectomy with immediate expander reconstruction). Proton therapy improved coverage of level 2 axilla (P=.0005). Adequate coverage of internal mammary nodes was consistently achieved with PT (median D95, 50.3 Gy; range, 46.6-52.1 Gy) but not with conventional radiation therapy (median D95, 48.2 Gy; range, 40.8-55 Gy; P=.0005). Median cardiac V5 was 0.6% with PT and 16.3% with conventional radiation (P<.0001). Median ipsilateral lung V5 and V20 were improved with PT (median V5 35.3% vs 60.5% [P<.0001]; and median V20, 21.6% vs 35.5% [P<.0001]). Grade 3 dermatitis developed in 4 patients (22%), which was the only grade 3 toxicity. No grade 4+ toxicities developed. Conclusion: Proton therapy for RNI after mastectomy or BCT significantly improves cardiac dose, especially for left-sided patients, and lung V5 and V20 in all patients without excessive acute toxicity. Proton therapy simultaneously improves target coverage for the internal mammary nodes and level 2 axilla, which may positively impact long-term survival in breast cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SLUDGE BATCH SUPPLEMENTAL SRAT RUNS EFFECTS OF YIELD STRESS AND CYCLE TIME INCREASE

The Defense Waste Processing Facility (DWPF) has transitioned from Sludge Batch 5 (SB5) processing to Sludge Batch 6 (SB6) processing. Phase III-Tank 40 Chemical Process Cell (CPC) flowsheet simulations have been completed to determine the initial processing conditions for the DWPF transition. The impact of higher yield stress (SB-25) and cycle time extension (SB6-26) on the physical and chemical effects of SB6 processing during the SRAT (Sludge Receipt and Adjustment Tank) cycle were evaluated. No significant impacts on the SRAT chemistry were noted during the higher yield stress run. In particular, no impact on mercury stripping was noted, indicating that settling of elemental mercury was not the primary factor in the low mercury recovery noted in the flowsheet testing. The SRAT product from this run retained the higher yield stress of the starting sludge. The run indicated that ultrasonication is an effective tool to increase the yield stress of simulants to targeted values and the chemistry of downstream processing is not impacted. Significant differences were noted in the cycle time extension test compared to the Phase III flowsheet baseline runs. Large decreases in the ammonia and hydrogen generation rates were noted along with reduced mercury stripping efficiency. The latter effect is similar to that of operating under a high acid stoichiometry. It is conceivable that, under the distinctly different conditions of high formic acid concentration (high acid run) or slow formic acid addition (extended run), that mercury could form amalgams with noble metals, possibly rendering both inert. Thus, the removal of free mercury and noble metals could decrease the rate of catalytic formic acid reactions which would decrease generation of ammonium and hydrogen. The potential underlying reasons for the behavior noted during this run would require additional testing.

08 HYDROGEN↗

Neuro-behavioral Consequences of Low Dose Radiation Social Isolation and Sex Differences in the Longevity MCAT Mouse Model

The physiological responses to spaceflight elicit wide-ranging consequences and resemble aspects of aging on Earth. Previous studies have shown that oxidative damage via reactive oxygen species (ROS), contributes to aging-related pathologies. Our study uses 1-year old C57BL/6NJ male and female mice (astronaut-relevant age) that underwent exposure to 0.5 gray of gamma radiation together with social isolation and were euthanized 12 weeks after. We used the longevity MCAT mouse model in which human catalase is overexpressed in the mitochondria, for ROS quenching. We aimed to determine whether in older mice quenching ROS, will mitigate the neuro-behavioral consequences of low dose ionizing radiation and/or social isolation and whether the outcomes will differ in males and females. We have performed five mission relevant behavioral tests which focused on performance, memory, physical stance, and stress. We have detected both sex and radiation effects; the older females look physically better are faster and perform better almost in all behavioral tests compared to their male counterparts. On the other hand, they are more sensitive to low dose radiation in many cases, in some cases this effect was indeed mitigated in the MCAT mice, pointing out to the importance of ROS in response to radiation stress and social isolation. We have measured plasma (7- and 90-days post radiation), cytokines, corticosterone and hippocampal cytokine and microglial activation at the end of the experiment. We saw significant changes in the plasma markers due to radiation, sex, and genotype in both short and long post radiation period and detected long term sex and radiation effects in the brain. Our focus is now on applying advanced statistical modeling to corelate the behavioral tests with our recent molecular findings to look for specific biomarkers that could predict behavioral deficits.

radiation↗

WE-E-17A-07: Patient-Specific Mathematical Neuro-Oncology: Biologically-Informed Radiation Therapy and Imaging Physics

Purpose: To demonstrate a method of generating patient-specific, biologically-guided radiation therapy (RT) plans and to quantify and predict response to RT in glioblastoma. We investigate the biological correlates and imaging physics driving T2-MRI based response to radiation therapy using an MRI simulator. Methods: We have integrated a patient-specific biomathematical model of glioblastoma proliferation, invasion and radiotherapy with a multiobjective evolutionary algorithm for intensity-modulated RT optimization to construct individualized, biologically-guided plans. Patient-individualized simulations of the standard-of-care and optimized plans are compared in terms of several biological metrics quantified on MRI. An extension of the PI model is used to investigate the role of angiogenesis and its correlates in glioma response to therapy with the Proliferation-Invasion-Hypoxia- Necrosis-Angiogenesis model (PIHNA). The PIHNA model is used with a brain tissue phantom to predict tumor-induced vasogenic edema, tumor and tissue density that is used in a multi-compartmental MRI signal equation for generation of simulated T2- weighted MRIs. Results: Applying a novel metric of treatment response (Days Gained) to the patient-individualized simulation results predicted that the optimized RT plans would have a significant impact on delaying tumor progression, with Days Gained increases from 21% to 105%. For the T2- MRI simulations, initial validation tests compared average simulated T2 values for white matter, tumor, and peripheral edema to values cited in the literature. Simulated results closely match the characteristic T2 value for each tissue. Conclusion: Patient-individualized simulations using the combination of a biomathematical model with an optimization algorithm for RT generated biologically-guided doses that decreased normal tissue dose and increased therapeutic ratio with the potential to improve survival outcomes for treatment of glioblastoma. Simulated T2-MRI is shown to be consistent with known physics of MRI and can be used to further investigate biological drivers of imaging-based response to RT.

60 APPLIED LIFE SCIENCES↗

Progress Report on Performance of A709 and G91 Steels in Sodium

Specimens in six different processing and heat treatment conditions of A709 H58776 were exposed to sodium at 550, 600, and 650°C, respectively for various exposure times. G91 base metal was tested in sodium at 550, 600, and 650°C, and G91 weldment at 550 and 600°C, respectively. Parallel thermal aging experiments were conducted on G91 and A709 to obtain thermal aging data for comparison with sodium exposure results to separate the thermal and sodium effects. The corrosion data obtained on A709 steel continue to show low corrosion rates, which indicate good compatibility of A709 with sodium when oxygen content is controlled. G91 has also shown acceptable corrosion rates over the temperature range of 550-650°C in sodium. Thermal aging or sodium exposures reduced the tensile strength, uniform elongation, and total elongation for A709 ESR, AOD specimens. These specimens consistently showed higher yield stress and tensile strength and lower uniform and total elongations after sodium exposure than after thermal aging under comparable testing conditions. It implies that there was an additional effect of sodium exposure that gave rise to an increase in tensile strength of A709. Dynamic strain aginginduced flow serrations were completely removed by either thermal aging or sodium exposure at 650°C, which imply that carbon or nitrogen in solution was removed from the solution and formed precipitates during aging or sodium exposures. The tensile data ruled out the possibility of decarburization under the sodium exposure conditions. The HOMO specimens behaved somewhat differently from the ESR and AOD specimens in sodium. While thermal aging and sodium exposures at 550 and 600°C decreased the yield stress and the ultimate tensile strength of G91, there was virtually no additional effect resulting from sodium exposures at these two temperatures. In contrast, sodium exposures at 650°C had a drastic effect on the yield stress and the ultimate tensile strength of G91. It is suggested that G91 experienced decarburization in the 650°C sodium environments. Carbon concentrations in sodium in the SMT-1 and SMT-2 loops were determined by a foil equilibration method. The estimated carbon concentration was in the range of 0.8-1.2 ppm in the SMT-1 loop and 0.3-0.7 ppm in the SMT-2 loop. The carbon activity in sodium in the SMT-2 loop was estimated to be 0.03-0.08 at 600°C, and 0.08-0.2 at 550°C. The carbon activity in sodium at 650°C in the SMT-1 loop was 0.04-0.07. Equilibrium simulation of the carburization – decarburization processes was conducted for A709 and G91 steels exposed in sodium environments at temperatures of 550-700°C. The carbon activity-concentration relationship for G91 was re-evaluated by considering four phases in G91, i.e. bcc ferrite, M 23 C 6 , NbC and VC carbides. It was found that the carburization-decarburization process in G91 steel was dictated by M 23 C 6 carbides at high carbon activities, while NbC carbides dominated the process at low carbon activities. Formation of NbC increases the decarburization resistance of G91 steel. It remains to be understood whether the decarburization resistance provided by MC carbides in G91 can be maintained during long-term operations of SFRs. The carbon concentration-activity relationship for A709 was calculated based on the equilibrium of fcc-austenite and M 23 C 6 carbide phase. The calculations showed that A709 decarburizes at 650°C in the SMT-1 loop environments, which is different from the experimental findings. The carbon concentration-activity relationship in A709 was further evaluated by considering four phases, including fcc-austenite, M 23 C 6 , NbC, and TiC carbide phases. TiC is the most stable carbides among the three carbide phases. The carburization-decarburization process in A709 is dictated by M 23 C 6 carbides at high carbon activities and by TiC at low carbon activities. Formation of TiC increases the decarburization resistance of A709 steel. Because of the complexity of the precipitation process in A709 during sodium exposures, detailed characterization of precipitates in sodium-exposed specimens and improved thermodynamic models are needed to understand the carburization-decarburization behavior of A709. Kinetic analysis of carbon transfer will be investigated for G91 and A709 in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Calculated and Measured Performance Characteristics of a Heated-Wire Liquid-Water-Content Meter for Measuring Icing Severity

Ground tests have been made of an instrument which, when assembled in a more compact form for flight installation, could be used to obtain statistical flight data on the liquid-water content of icing clouds and to provide an indication of icing severity. The sensing element of the instrument consists of an electrically heated wire which is mounted in the air stream. The degree of cooling of the wire resulting from evaporation of the impinging water droplets is a measure. of the liquid-water content of the cloud. Determination of the value of the liquid-water content from the wire temperature at any instant requires a knowledge of the airspeed, altitude, and air temperature. An analysis was made of the temperature response of a heated wire exposed to an air stream containing water drops. Comparisons were made of the liquid-water content as measured with several heated wires and absorbent cylinders in an artificially produced cloud. For one of the wires, comparative tests were made with a rotating-disk icing-rate meter in an icing wind tunnel. From the test results, it was shown that an instrument for measuring the concentration of liquid water in an air stream can be built using an electrically heated wire of known temperatureresistance characteristics, and that the performance of such a device can be predicted using appropriate theory. Although an instrument in a form suitable for gathering statistical data in flight was not built, the practicability of constructing such an instrument was illustrated. The ground-test results indicated that a flight heated-wire instrument would be simple and durable, would respond rapidly to variations in liquid-water content, and could be used for the measurement of water content in clouds which are above freezing temperature, as well as in icing clouds.

Neel, Carr B.↗

Performance Comparison Between a Head-Worn Display System and a Head-Up Display for Low Visibility Commercial Operations

Research, development, test, and evaluation of flight deck interface technologies is being conducted by NASA to proactively identify, develop, and mature tools, methods, and technologies for improving overall aircraft safety of new and legacy vehicles operating in Next Generation Air Transportation System (NextGen). Under the Vehicle Systems Safety Technologies (VSST) project in the Aviation Safety Program, one specific area of research is the use of small Head-Worn Displays (HWDs) as an equivalent display to a Head-Up Display (HUD). Title 14 of the US Code of Federal Regulations (CFR) 91.175 describes a possible operational credit which can be obtained with airplane equipage of a HUD or an "equivalent" display combined with Enhanced Vision (EV). If successful, a HWD may provide the same safety and operational benefits as current HUD-equipped aircraft but for significantly more aircraft in which HUD installation is neither practical nor possible. A simulation experiment was conducted to evaluate if the HWD, coupled with a head-tracker, can provide an equivalent display to a HUD. Comparative testing was performed in the Research Flight Deck (RFD) Cockpit Motion Facility (CMF) full mission, motion-based simulator at NASA Langley. Twelve airline crews conducted approach and landing, taxi, and departure operations during low visibility operations (1000' Runway Visual Range (RVR), 300' RVR) at Memphis International Airport (Federal Aviation Administration (FAA) identifier: KMEM). The results showed that there were no statistical differences in the crews performance in terms of touchdown and takeoff. Further, there were no statistical differences between the HUD and HWD in pilots' responses to questionnaires.

Arthur, Jarvis J., III↗

DEVELOPMENT QUALIFICATION AND DISPOSAL OF AN ALTERNATIVE IMMOBILIZED LOW-ACTIVITY WASTE FORM AT THE HANFORD SITE

Demonstrating that a waste form produced by a given immobilization process is chemically and physically durable as well as compliant with disposal facility acceptance criteria is critical to the success of a waste treatment program, and must be pursued in conjunction with the maturation of the waste processing technology. Testing of waste forms produced using differing scales of processing units and classes of feeds (simulants versus actual waste) is the crux of the waste form qualification process. Testing is typically focused on leachability of constituents of concern (COCs), as well as chemical and physical durability of the waste form. A principal challenge regarding testing immobilized low-activity waste (ILAW) forms is the absence of a standard test suite or set of mandatory parameters against which waste forms may be tested, compared, and qualified for acceptance in existing and proposed nuclear waste disposal sites at Hanford and across the Department of Energy (DOE) complex. A coherent and widely applicable compliance strategy to support characterization and disposal of new waste forms is essential to enhance and accelerate the remediation of DOE tank waste. This paper provides a background summary of important entities, regulations, and considerations for nuclear waste form qualification and disposal. Against this backdrop, this paper describes a strategy for meeting and demonstrating compliance with disposal requirements emphasizing the River Protection Project (RPP) Integrated Disposal Facility (IDF) at the Hanford Site and the fluidized bed steam reforming (FBSR) mineralized low-activity waste (LAW) product stream.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WE-DE-201-11: Sensitivity and Specificity of Verification Methods Based On Total Reference Air Kerma (TRAK) Or On User Provided Dose Points for Graphically Planned Skin HDR Brachytherapy

Purpose: To investigate the sensitivity and specificity of a novel verification methodology for image-guided skin HDR brachytherapy plans using a TRAK-based reasonableness test, compared to a typical manual verification methodology. Methods: Two methodologies were used to flag treatment plans necessitating additional review due to a potential discrepancy of 3 mm between planned dose and clinical target in the skin. Manual verification was used to calculate the discrepancy between the average dose to points positioned at time of planning representative of the prescribed depth and the expected prescription dose. Automatic verification was used to calculate the discrepancy between TRAK of the clinical plan and its expected value, which was calculated using standard plans with varying curvatures, ranging from flat to cylindrically circumferential. A plan was flagged if a discrepancy >10% was observed. Sensitivity and specificity were calculated using as a criteria for true positive that >10% of plan dwells had a distance to prescription dose >1 mm different than prescription depth (3 mm + size of applicator). All HDR image-based skin brachytherapy plans treated at our institution in 2013 were analyzed. Results: 108 surface applicator plans to treat skin of the face, scalp, limbs, feet, hands or abdomen were analyzed. Median number of catheters was 19 (range, 4 to 71) and median number of dwells was 257 (range, 20 to 1100). Sensitivity/specificity were 57%/78% for manual and 70%/89% for automatic verification. Conclusion: A check based on expected TRAK value is feasible for irregularly shaped, image-guided skin HDR brachytherapy. This test yielded higher sensitivity and specificity than a test based on the identification of representative points, and can be implemented with a dedicated calculation code or with pre-calculated lookup tables of ideally shaped, uniform surface applicators.

60 APPLIED LIFE SCIENCES↗

Building a predictive model for polycyclic aromatic hydrocarbon dosimetry in organotypically cultured human bronchial epithelial cells using benzo[ a ]pyrene

The airway epithelium is a primary route of exposure for inhaled toxicants, and organotypic culture models represent an important advancement for toxicity testing compared to simple in vitro models that may lack metabolic capability and multicellular structure/communication associated with the bronchial epithelium in vivo. A quantitative understanding of chemical dosimetry is key for interpreting and extrapolating study results; however, dosimetry is understudied in organotypic models limiting ability to predict toxicity. We developed a dosimetry model for primary human bronchial epithelial cells (HBECs) cultured at the air-liquid interface (ALI) using benzo[a]pyrene (BAP), a representative polycyclic aromatic hydrocarbon. Dose and time course evaluation of metabolite formation and enzyme activity and expression were utilized to parameterize a cellular dosimetry model to improve the utility of ALI-HBECs for assessing chemical risk. Dosimetry analysis demonstrated absorption of BAP into cells and an increase in Phase 1 and 2 metabolites over time that correlated with regulation of metabolizing enzymes. BAP was cleared from cells by 48 h after exposure, and the primary metabolites generated in ALI-HBECs were BAP-3-phenol, BAP-4,5-dihydrodiol, BAP-7,8-dihydrodiol, BAP-9,10-dihydrodiol, BAP-7,8,9,10-tetrol, BAP-3-phenol-glucuronide, BAP-4,5-dihydrodiol-glucuronide, and BAP-9,10-dihydrodiol-glucuronide. The resulting dosimetry model described BAP and 7,8-dihydrodiol toxicokinetics in ALI-HBECs and suggested active excretion of 7,8-dihydrodiol. Overall, this study demonstrates metabolic competency of ALI-HBECs for BAP metabolism, demonstrates the usefulness of complex in vitro systems for human-relevant toxicity data, and exhibits how in silico models can be utilized for understanding the dosimetry of test compounds to aid in in vitro to human extrapolation of toxicity data for risk assessments.

Benzo[a]pyrene↗