Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMFORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Technology Solutions Case Study: Overcoming Comfort Issues Due to Reduced Flow Room Air Mixing

Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. In this project, IBACOS studied when HVAC equipment is downsized and ducts are unaltered to determine conditions that could cause a supply air delivery problem and to evaluate the feasibility of modifying the duct systems using minimally invasive strategies to improve air distribution.

AIR DISTRIBUTION↗

SUPERVISORY CONTROL FOR PEAK REDUCTION IN COMMERCIAL BUILDINGS WHILE MAINTAINING COMFORT

This paper describes a supervisory control strategy for limiting peak power demand by small and medium commercial buildings while still meeting the business needs of the occupants. This control strategy has two features that make it relevant to new and existing buildings. First, it is designed to operate with building equipment, such as air conditioning and refrigeration systems, as they are presently installed in most small and medium commercial buildings. Because of this, the supervisory control could be realized as a software-only retrofit to existing building management systems. Second, the proposed control acts as a supervisory management layer over existing control systems, rather than replacing them outright. The primary idea of this approach is that the controls for individual building equipment request energy resources for a control action and the supervisory control examines the requests and decides which control actions to allow while satisfying a limit on peak power demand.

Nutaro, James J↗

New Rating Opening Windows to a World of Comfort, Opportunity, and Cost-Effective Savings

Window attachments offer a huge, cost-effective energy-saving opportunity that remains largely untapped. The newly launched window attachment energy rating and certification program, through the Attachments Energy Rating Council (AERC), is altering the way people think about residential and commercial window attachments by providing reliable, easy-to-understand energy performance information to consumers. Window attachments, such as blinds, shades, shutters, awnings, and low-emissivity (low-e) storm windows, represent an enormous existing market. With 64% of U.S. homes having single- or double-pane clear (non-low-e) less-efficient windows, the savings opportunity is significant. Studies of model homes show energy savings of 10% or more after installing more efficient storm window and cellular shades technologies (AERC 2016).In a study conducted by Efficiency Vermont, 68% of respondents had concerns with their existing windows and could benefit from an upgrade (Efficiency Vermont 2016).Through AERC, window attachment products are rated based on their Energy Performance (EP). The EP metric is an easy-to-understand comparative metric created for consumers. This rating not only allows consumers to make more informed decisions when buying attachments products, but also creates a new energy savings measure for utilities and efficiency programs to incentivize energy efficient window attachment products. This paper will outline the savings potential of window attachments, introduce the AERC rating program, detail the methodology behind the Energy Performance ratings, and explain the AERCalc tool that generates the ratings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Personal cooling and the Roving Comforter

Today we heat and cool buildings to a single target temperature. Some problems with this conventional regime can be readily observed: first, people have differing opinions of the appropriate target temperature; and second, conditioning a whole building requires much more energy than conditioning the air immediately surrounding the occupants. In contrast to most conventional approaches to decreasing energy consumption, personal cooling offers a plug and play solution by providing localized space conditioning directly to individuals. Furthermore, this shift in perspective, from the room air temperature to the individual, opens new possibilities to enable more sustainable cooling architectures for energy efficient space and building design at lower cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Rating Opening Windows to a World of Comfort, Opportunity, and Cost-Effective Savings

Window attachments offer a huge, cost-effective energy-saving opportunity that remains largely untapped. The newly launched window attachment energy rating and certification program, through the Attachments Energy Rating Council (AERC), is altering the way people think about residential and commercial window attachments by providing reliable, easy-to-understand energy performance information to consumers. Window attachments, such as blinds, shades, shutters, awnings, and low-emissivity (low-e) storm windows, represent an enormous existing market. With 64% of U.S. homes having single- or double-pane clear (non-low-e) less-efficient windows, the savings opportunity is significant. Studies of model homes show energy savings of 10% or more after installing more efficient storm window and cellular shades technologies (AERC 2016). In a study conducted by Efficiency Vermont, 68% of respondents had concerns with their existing windows and could benefit from an upgrade (Efficiency Vermont 2016). Through AERC, window attachment products are rated based on their Energy Performance (EP). The EP metric is an easy-to-understand comparative metric created for consumers. This rating not only allows consumers to make more informed decisions when buying attachments products, but also creates a new energy savings measure for utilities and efficiency programs to incentivize energy efficient window attachment products. Here, this paper will outline the savings potential of window attachments, introduce the AERC rating program, detail the methodology behind the Energy Performance ratings, and explain the AERCalc tool that generates the ratings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dexterity and Worker Comfort in an Ergonomically Designed Glovebox Glove

Gloveboxes are prolifically used in nuclear facilities as the primary means of separation between the hazardous material and operators. Due to extended duration and high repetition of hand tasks in glovebox gloves, improperly fitting gloves can be uncomfortable and increase injury risks. Poor fit can increase time necessary to perform work tasks and stress the glove itself. The Plutonium Facility has the largest inventory of glovebox gloves at Los Alamos National Laboratory (LANL) with approximately 6000 gloves installed. The current glove mold dates back to the 1960's and is not based on the true anatomy of the hand. Design flaws (poor anatomical fit and biomechanics) are directly related to injuries of the elbow (lateral epicondylitis) and thumb (DeQuervain's tenosynovitis) injuries. The current design also contributes to 30% of unplanned glove openings. A new glovebox glove was developed and manufactured, incorporating over forty dimensions to produce the most comprehensive ergonomically sound design. The new design received a LANL patent (patent attorney docket No: LANS 36USD1 'Protective Glove'), one of 20 highest patents awarded by the Richard P. Feynman Center for Innovation. A SolidWorks model was given to the manufacturer for production of the glove mold.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

User Acceptance of Shared Autonomous Vehicles

A dissertation is proposed to explore user acceptance of shared autonomous vehicles (SAVs). SAVs are facing limited user acceptance. To systematically tackle the user acceptance barriers of SAVs, the main problem can be disintegrated into two sub-problems of user acceptance of autonomous vehicles (AVs) and ridesharing. The comfort of the ride experience in AVs is a determinant of user acceptance. Understanding the influential factors and developing methodologies to quantify human comfort in AVs are essential to facilitating future research to improve human comfort in AVs. The current pooled rideshare (PR) service closely resembles the anticipated future of SAVs. Understanding why users prefer or refuse to use PR at the current stage prepares SAVs for broader acceptance in the future. Until now, a series of peer-reviewed publications have been published to achieve the technical goals. Two simulator-based user studies were conducted to instrument the research on human comfort in AVs. Statistical analysis was performed to identify the crucial vehicular behavioral factors of human comfort in AVs. The influential factors of human comfort in AVs and methodologies to quantify and detect human comfort in AVs were investigated. Two survey-based studies were deployed to facilitate the investigation of user acceptance of rideshare services. The influential factors of users' willingness to consider PR were explored and identified, and the choice behaviors in ridesharing services were comprehensively modeled and analyzed. The proposed research answers a series of fundamental questions regarding the user acceptance of SAVs. For the branch of user acceptance of AVs, the research generated guidelines for improving passenger comfort in AVs by identifying a series of autonomous driving factors of passenger comfort. The research also provides fundamental tools to estimate human comfort levels for future research and in-AV applications. For the branch of user acceptance of PR, the research provided user acceptance-aware vehicle, service, and policy design insights that can promote the usage of PR.

Su, Haotian↗

Performance evaluation of passive cooling in office buildings based on uncertainty and sensitivity analysis

Natural night ventilation is an interesting passive cooling method in moderate climates. Driven by wind and stack generated pressures, it cools down the exposed building structure at night, in which the heat of the previous day is accumulated. The performance of natural night ventilation highly depends on the external weather conditions and especially on the outdoor temperature. An increase of this outdoor temperature is noticed over the last century and the IPCC predicts an additional rise to the end of this century. A methodology is needed to evaluate the reliable operation of the indoor climate of buildings in case of warmer and uncertain summer conditions. The uncertainty on the climate and on other design data can be very important in the decision process of a building project. The aim of this research is to develop a methodology to predict the performance of natural night ventilation using building energy simulation taking into account the uncertainties in the input. The performance evaluation of natural night ventilation is based on uncertainty and sensitivity analysis. The results of the uncertainty analysis showed that thermal comfort in a single office cooled with single-sided night ventilation had the largest uncertainty. The uncertainties on thermal comfort in case of passive stack and cross ventilation were substantially smaller. However, since wind, as the main driving force for cross ventilation, is highly variable, the cross ventilation strategy required larger louvre areas than the stack ventilation strategy to achieve a similar performance. The differences in uncertainty between the orientations were small. Sensitivity analysis was used to determine the most dominant set of input parameters causing the uncertainty on thermal comfort. The internal heat gains, solar heat gain coefficient of the sunblinds, internal convective heat transfer coefficient, thermophysical properties related to thermal mass, set-point temperatures controlling the natural night ventilation, the discharge coefficient C{sub d} of the night ventilation opening and the wind pressure coefficients C{sub p} were identified to have the largest impact on the uncertainty of thermal comfort. The impact of the warming climate on the uncertainty of thermal comfort was determined. The uncertainty on thermal comfort appeared to increase significantly when a weather data set with recurrence time of 10 years (warm weather) was applied in the transient simulations in stead of a standard weather data set. Natural night ventilation, designed for normal weather conditions, was clearly not able to ensure a high probability of good thermal comfort in warm weather. To ensure a high probability of good thermal comfort and to reduce the performance uncertainty in a warming climate, natural night ventilation has to be combined with additional measures. Different measures were analysed, based on the results of the sensitivity analysis. All the measures were shown to significantly decrease the uncertainty of thermal comfort in warm weather. The study showed the importance to carry out simulations with a warm weather data set together with the analysis under typical conditions. This approach allows to gain a better understanding of the performance of a natural night ventilation design, and to optimize the design to a robust solution. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ford Thermoelectric HVAC Project (Final Report)

Current light-duty vehicles provide passenger thermal comfort primarily through the use of a centralized HVAC (Heating, Ventilation, and Air Conditioning) unit that distributes conditioned air to vent locations throughout the vehicle. A substantial portion of the air energy content is spent conditioning various elements of the vehicle's interior structures. This is not an overwhelming issue in today’s vehicles, but as pressure builds to improve powertrain efficiency, the energy available to provide occupant comfort will decrease. Thermoelectric devices were identified by the US Department of Energy as one method to potentially reduce HVAC-related energy consumption in vehicles. The objective of the Ford Thermoelectric HVAC Project was to identify a technical and business approach to accelerate research and development of light-duty automotive thermoelectric HVAC technology. A zonal HVAC system was developed to provide thermal comfort to each occupant, with the objective of reducing the overall power consumed by the HVAC system compared with a baseline system. The system was designed to provide a basis for a down-sized central HVAC unit, while providing equivalent comfort and equivalent heating/cooling time-to-comfort at startup, and reduce the energy consumed to provide these functions. Project success was evaluated using occupant comfort and energy consumption metrics, based on a novel thermal comfort-modeling approach, and empirical testing. The ability to produce and market the thermoelectric devices developed in this program was assessed by a business analysis that outlined key steps required for thermoelectric HVAC devices to come to market. Key hardware and controls attribute requirements were identified to determine how they contribute to the commercialization potential of the technology. Final testing and analysis showed that use of thermal comfort and zonal design criteria reduced the energy consumption of the climate control system in both heating and cooling tests, and were significantly better in low vehicle occupancy cases where zonal strategies could be employed. Thermoelectric devices were utilized in the vehicle design to support achieving the technical performance goals of the project. It was found that these devices need additional development in order to address commercial issues, due to their cost and performance limitations.

99 GENERAL AND MISCELLANEOUS↗

Socially Driven HVAC Optimization Federal Building and US Courthouse Phoenix, Arizona

Under many circumstances in facilities management, keeping occupants comfortable and saving energy are diametrically opposed. To stay cool in summer and warm in winter requires energy to maintain indoor temperatures. If energy is saved by allowing indoor temperatures to get warmer in the summer or colder in winter, occupants’ comfort levels decrease. There is great potential to reduce costs and maintain occupant comfort if a system existed that could break this diametric opposition. The comfort of building occupants in today’s facilities is controlled by maintaining a given space temperature through the use of a thermostat. These devices operate in a very simple manner in which they are set to maintain a certain constant space temperature range. If the occupant is too hot or cold, he or she writes a work order for facility maintenance staff to adjust the thermostat to a new constant temperature range. This feedback cycle is repeated as needed to avoid generating complaints of too hot/cold from the occupants. This system has two areas in which it can be improved. First, there is the labor cost associated with a facilities maintenance person having to respond to each request when an occupant is uncomfortable. Person-hours are spent receiving the work order and adjusting space thermostats to a level that, hopefully, will allow the occupant to be comfortable. Second, the space temperature is maintained within a constant range, with no effort being made to finetune the space temperature to a setting that conserves energy while maintaining occupant comfort. Occupant comfort is based upon many more factors than just the space temperature. When other factors are taken into account, there is potential to save energy while maintaining that comfort level.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency of Distributed Environmental Control Systems

In this report, we present an analytical evaluation of the potential of occupant-regulated distributed environmental control systems (DECS) to enhance individual occupant thermal comfort in an office building with no increase, and possibly even a decrease in annual energy consumption. To this end we developed and applied several analytical models that allowed us to optimize comfort and energy consumption in partitioned office buildings equipped with either conventional central HVAC systems or occupant-regulated DECS. Our approach involved the following interrelated components: 1. Development of a simplified lumped-parameter thermal circuit model to compute the annual energy consumption. This was necessitated by the need to perform tens of thousands of optimization calculations involving different US climatic regions, and different occupant thermal preferences of a population of ~50 office occupants. Yearly transient simulations using TRNSYS, a time-dependent building energy modeling program, were run to determine the robustness of the simplified approach against time-dependent simulations. The simplified model predicts yearly energy consumption within approximately 0.6% of an equivalent transient simulation. Simulations of building energy usage were run for a wide variety of climatic regions and control scenarios, including traditional “one-size-fits-all” (OSFA) control; providing a uniform temperature to the entire building, and occupant-selected “have-it-your-way” (HIYW) control with a thermostat at each workstation. The thermal model shows that, un-optimized, DECS would lead to an increase in building energy consumption between 3-16% compared to the conventional approach depending on the climate regional and personal preferences of building occupants. Variations in building shape had little impact in the relative energy usage. 2. Development of a gradient-based optimization method to minimize energy consumption of DECS while keeping each occupant’s thermal dissatisfaction below a given threshold. The DECS energy usage was calculated using the simplified thermal model. OSFA control; providing a uniform temperature to the entire building, and occupant-selected HIYW control with a thermostat at each workstation were implemented for 3 cities representing 3 different climatic regions and control scenarios. It is shown that optimization allows DECS to deliver a higher level of individual and population thermal comfort while achieving annual energy savings between 14 and 26% compared to OSFA. The optimization model also allowed us to study the influence of the partitions’ thermal resistance and the variability of internal loads at each office. These influences didn’t make significant changes in the optimized energy consumption relative to OSFA. The results show that it is possible to provide thermal comfort for each occupant while saving energy compared to OSFA Furthermore, to simplify the implementation of this approach, a fuzzy logic system has been developed to generalize the overall optimization strategy. Its performance was almost as good as the gradient system. The fuzzy system provided thermal comfort to each occupant and saved energy compared to OSFA. The energy savings of the fuzzy system were not as high as for the gradient-optimized system, but the fuzzy system avoided complete connectivity, and the optimization did not have to be repeated for each population. 3. We employed a detailed CFD model of adjacent occupied cubicles to extend the thermal-circuit model in three significant ways: (a) relax the “office wall” requirement by allowing energy to flow between zones via advection as well as conduction, (b) improve the comfort model to account both for radiation as well as convection heat transfer, and (c) support ventilation systems in which the temperature is stratified, such as in underfloor air distribution systems. Initially, three-dimensional CFD simulations of several cubicle configurations, with an adjoining corridor, were performed both to understand the advection between cubicles and the resulting temperature stratification. These simulations showed that the advective flow between cubicles is very significant and severely limits the occupants’ ability to control the personal micro-environments by simply controlling the temperature of the incoming air. Subsequently, the existing thermal-circuit model was extended to include the phenomena described above. The modifications to the thermal-circuit model, which were incorporated such that the simulation time was only slightly impacted, showed that accounting for room stratification resulting from the use of floor swirl diffusers could lead to 10%-26% reduction in the annual energy consumed for HVAC in non-temperate climates. This trend was evident in both OSFA and HIYW scenarios. However, the ratio of energy usage in the two scenarios was little affected by the enhancements in the thermal model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗