Study of effect of PWR cold leg temperature gradient on reactor core condition

Effects of temperature and flow gradients in Westinghouse designed three-loop Pressurized Water Reactor (PWR) cold legs, the piping between the main coolant pump and the reactor vessel, were evaluated using Computational Fluid Dynamics (CFD) code STAR CCM+ and coupled neutronic and thermal-hydraulic (T/H) code system VERA. In the parametric study, several symmetric and asymmetric temperature gradients that were significantly larger than those observed from plant measurements were applied to the cold leg inlets for comparison with the base case without any temperature gradient. A CFD model using the STAR-CCM+ code was developed for a portion of the RCS region between the Reactor Coolant Pump (RCP) and the core inlet based on previously validated modeling approach. The CFD simulation results were processed for the temperature and flow rate distributions at the core inlet as input to the VERA calculations. The VERA code system consists of COBRA-TF (CTF) for thermal-hydraulics, MPACT for reactor physics and neutron transport, and ORIGEN for isotopic depletion. The VERA model was for depletion calculations of a high-burnup loading pattern with the reactor core in pin-by-pin and subchannel resolution. The results of the study indicate that the postulated temperature gradients within the PWR cold legs do not result in any significant changes in the core inlet temperature distributions and the core power distributions during the reactor operation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Modeling-Based Flammable Risk Treatment of Refrigerant Leakage from a Commercial R-290 Refrigeration Machine

Because of serious concerns about global warming, manufacturers have started phasing out high global warming potential (GWP) refrigerants in commercial refrigeration equipment (e.g., R-134a). As a potential replacement, propane (R-290) is an environmentally friendly refrigerant for commercial refrigeration equipment because its GWP is only three. However, propane is flammable and is therefore classified as a Class A3 refrigerant per ASHRAE Standards, so safety is a very important consideration when propane-based equipment is designed and deployed in buildings. In the event of a refrigerant leak, flammability of the refrigerant depends on the refrigerant’s local concentration, which is highly affected by the indoor air environment, including temperature and air flow. In this study, a ventilation system attached to a commercial R-290 refrigeration device was designed to eliminate the flammability risk. Moreover, a computational fluid dynamics (CFD) model was developed to investigate the refrigerant leak, thereby evaluating effects of the ventilation system. The CFD model can visualize the flammable zones owing to the leak.

42 ENGINEERING↗

A whole-core steady-state thermal-hydraulic model for annular fuel type fluoride-salt-cooled reactors

A whole-core, steady-state thermal-hydraulic model is developed for the fluoride-salt-cooled small modular advanced high-temperature reactor (SmAHTR) that employs an annular fuel configuration. This pre-conceptual reactor design by Oak Ridge National Laboratory (ORNL) has the annular fuel and moderator pins arranged in a hexagonal layout. The FLiBe coolant flows from the bottom to the top of the core, parallel to the hexagonal bundle. The fuel and moderator pins in the core are discretized into finite volumes and the 3-D heat conduction equation is solved to obtain the temperature profile. Inter-fuel assembly conduction is also addressed. For this fuel assembly configuration, the coolant flows through two distinct regions – the hexagonal pin bundle and the annulus between the fuel pin and the tie rod. The fluid flow through the hexagonal bundles is modeled using the subchannel approach, in which the coolant region is discretized into corner, edge and interior subchannels and the resulting conservation equations are systematically solved. The 1-D mass, momentum and energy equations are solved for the annulus channels between the fuel pin and the tie rod. Pertinent closure models from the literature are employed to close the system of equations. We also performed a preliminary code-to-code comparison between the present model and a CFD model.. The resulting thermal-hydraulic model can provide temperature, flow rate and pressure drop profiles for the different solid and fluid regions throughout the entire core. Whole-core thermal-hydraulic results for a representative power profile are presented and discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of High-Deflection Foils MHK Applications - FEA models

The Ocean Renewable Power Company's (ORPC's) goal is to design, develop, and test hydrofoils with large deflections. The effects of the deflections on cross-flow turbine performance would be evaluated in order to inform design considerations for full-scale water turbines and other marine hydrokinetic devices. Finite element models - NASTRAN files Model scale turbines tested in UNH tow tank Model loads from CFD models

16 TIDAL AND WAVE POWER↗

Studying Rate of Fire Spread Using Landscape Statistics and FIRETEC

Wildfires are multi-system and multi-scale processes that are influenced by the land and atmosphere. Here, we study the influence of land, in terms of topography and vegetation, on uphill and downhill fire spread using data of the state of California as a testbed. The California landscape is first quantified by reclassifying its dominant vegetation types into grass, trees, and shrubs. Next, statistics of slope, vegetation height, and live fuel moisture percentage for each dominant vegetation type are gathered to create ensembles of idealized computational fluid dynamics (CFD) model simulations representative of the landscape. Rate of spread values for each CFD simulation are recorded to observe the differences in perturbing slope and fuel moisture for each vegetation type. We have found that all vegetation types prefer slopes of less than 30 degrees. Trees in the California data are 10 to 40 meters high, whereas shrub heights are less than 3 meters and grass heights are less than 1 meter. The live fuel moisture percentage of both trees and shrubs fluctuates around approximately 100% over one year (2019-2020). Using these parameters as inputs into the CFD model, fire spread rate is found to be fastest in the grass ensemble (maximum 12 m s -1 ), followed by shrubs (maximum 10 m s -1 ) and lastly by trees (maximum 7 m s -1 ). Increasing slope increases the spread rate of the uphill fire but the downhill spread decreases for slopes greater than 15 degrees. Increasing fuel moisture decreases the spread rate both up and down the hill. This study highlights the impacts that topography and vegetation have on fire spread.

54 ENVIRONMENTAL SCIENCES↗

Modeling Autogenous Pressurization and Draining of a Cryogenic Storage Tank in Normal Gravity

A two-phase CFD model for autogenous pressurization and draining of a cryogenic storage tank is presented using both the Sharp Interface and Volume-Of-Fluid (VOF) approaches for capturing the front and the associated interfacial heat, mass and momentum transfer between the liquid and vapor regions. Both models are validated against data provided by the Cryogenic Propellant Storage and Transfer (CPST) Engineering Development Unit (EDU) experiment. The results of the autogenous pressurization are presented first, focusing on the phase change and turbulence effects on the tank pressure and temperature predictions. Both the Sharp Interface (SI-CFD) and VOF (VOF-CFD) multiphase models predict tank pressure during pressurization within 3% of the measured values. The sensitivity of key physical and numerical parameters of the problem are tested using the Sharp Interface model. Effects of the accommodation coefficient (AC), and the computational grid structure are studied. The second part of this paper is devoted to validating the SI-VOF model, with an enhanced capability of moving the liquid-vapor interface, against the draining segment of the EDU experiment. The VOF-CFD model was also used to simulate tank draining and its results were compared with the results of the Sharp Interface model with the moving interface. Both models predict tank pressure during draining within 3.5% of the measured values. Pressure decrease rate is underpredicted by both models during the first 100 seconds of draining but matches the experimental rate for the rest of the simulation.

Computational Fluid Dynamics↗

Modeling Autogenous Pressurization and Draining of a Cryogenic Storage Tank in Normal Gravity

A two-phase CFD model for autogenous pressurization and draining of a cryogenic storage tank is presented using both the Sharp Interface and Volume-Of-Fluid (VOF) approaches for capturing the front and the associated interfacial heat, mass and momentum transfer between the liquid and vapor regions. Both models are validated against data provided by the Cryogenic Propellant Storage and Transfer (CPST) Engineering Development Unit (EDU) experiment1. The results of the autogenous pressurization are presented first, focusing on the phase change and turbulence effects on the tank pressure and temperature predictions. Both the Sharp Interface (SI-CFD) and VOF (VOF-CFD) multiphase models predict tank pressure during pressurization within 3% of the measured values. The sensitivity of key physical and numerical parameters of the problem are tested using the Sharp Interface model. Effects of the accommodation coefficient (AC), and the computational grid structure are studied. The second part of this paper is devoted to validating the SI-VOF model, with an enhanced capability of moving the liquid-vapor interface, against the draining segment of the EDU experiment. The VOF-CFD model was also used to simulate tank draining and its results were compared with the results of the Sharp Interface model with the moving interface. Both models predict tank pressure during draining within 3.5% of the measured values. Pressure decrease rate is underpredicted by both models during the first 100 seconds of draining but matches the experimental rate for the rest of the simulation.

Computational Fluid Dynamics↗

Experimental Evaluation of a Water Shield for a Surface Power Reactor

A water based shielding system is being investigated for use on initial lunar surface power systems. The use of water may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. A representative lunar surface reactor design is evaluated at various power levels in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The evaluation compares the experimental data from the WST to CFD models. Performance of a water shield on the lunar surface is predicted by CFD models anchored to test data, and by matching relevant dimensionless parameters.

Pearson, J. B.↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design. This revision models the individual maximum fan reduced flow capacity from 38,000 cfm to 31,200 cfm; no changes to the duct design are made.

42 ENGINEERING↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design.

42 ENGINEERING↗

Qualification of Mixing Criteria by Computational Fluid Dynamics Modeling for the 325 Building Stack Revision

Additional ventilation capacity has been designed for the 325 Building filtered exhaust stack system. The four (4) existing main facility exhaust fans are past the end of their useful life. The fans are being replaced to provide additional exhaust capacity for future growth and to provide a more robust system. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified four-fan system for compliance with the ANSI/HPS N13.1-2021 standard, which essentially is equivalent in mixing requirements to the ANSI/HPS N13.1-1999 standard (and ANSI/HPS N13.1-2011). The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. In addition to the evaluating the modified four-fan system a temporary single fan stack configuration was also evaluated with CFD modeling. The temporary stack is planned to be used while the four-fan system is being modified. Modeling of the modified four-fan design and temporary ductwork showed that flow angles, velocity uniformity, gas tracer, and particle tracer were acceptable.

42 ENGINEERING↗

Use of Boundary Layer Transition Detection to Validate Full-Scale Flight Performance Predictions

Full-scale flight performance predictions can be made using CFD or a combination of CFD and analytical skin-friction predictions. However, no matter what method is used to obtain full-scale flight performance predictions knowledge of the boundary layer state is critical. The implementation of CFD codes solving the Navier-Stokes equations to obtain these predictions is still a time consuming, expensive process. In addition, to ultimately obtain accurate performance predictions the transition location must be fixed in the CFD model. An example, using the M2.4-7A geometry, of the change in Navier-Stokes solution with changes in transition and in turbulence model will be shown. Oil flow visualization using the M2.4-7A 4.0% scale model in the 14'x22' wind tunnel shows that fixing transition at 10% x/c in the CFD model best captures the flow physics of the wing flow field. A less costly method of obtaining full-scale performance predictions is the use of non-linear Euler codes or linear CFD codes, such as panel methods, combined with analytical skin-friction predictions. Again, knowledge of the boundary layer state is critical to the accurate determination of full-scale flight performance. Boundary layer transition detection has been performed at 0.3 and 0.9 Mach numbers over an extensive Reynolds number range using the 2.2% scale Reference H model in the NTF. A temperature sensitive paint system was used to determine the boundary layer state for these conditions. Data was obtained for three configurations: the baseline, undeflected flaps configuration; the transonic cruise configuration; and, the high-lift configuration. It was determined that at low Reynolds number conditions, in the 8 to 10 million Reynolds number range, the baseline configuration has extensive regions of laminar flow, in fact significantly more than analytical skin-friction methods predict. This configuration is fully turbulent at about 30 million Reynolds number for both 0.3 and 0.9, Mach numbers. Both the transonic cruise and the high-lift configurations were fully turbulent aft of the leading-edge flap hingeline at all Reynolds numbers.

Hamner, Marvine↗

The use of computer models to predict temperature and smoke movement in high bay spaces

The Building and Fire Research Laboratory (BFRL) was given the opportunity to make measurements during fire calibration tests of the heat detection system in an aircraft hangar with a nominal 30.4 (100 ft) ceiling height near Dallas, TX. Fire gas temperatures resulting from an approximately 8250 kW isopropyl alcohol pool fire were measured above the fire and along the ceiling. The results of the experiments were then compared to predictions from the computer fire models DETACT-QS, FPETOOL, and LAVENT. In section A of the analysis conducted, DETACT-QS AND FPETOOL significantly underpredicted the gas temperature. LAVENT at the position below the ceiling corresponding to maximum temperature and velocity provided better agreement with the data. For large spaces, hot gas transport time and an improved fire plume dynamics model should be incorporated into the computer fire model activation routines. A computational fluid dynamics (CFD) model, HARWELL FLOW3D, was then used to model the hot gas movement in the space. Reasonable agreement was found between the temperatures predicted from the CFD calculations and the temperatures measured in the aircraft hangar. In section B, an existing NASA high bay space was modeled using the CFD model. The NASA space was a clean room, 27.4 m (90 ft) high with forced horizontal laminar flow. The purpose of this analysis is to determine how the existing fire detection devices would respond to various size fires in the space. The analysis was conducted for 32 MW, 400 kW, and 40 kW fires.

Notarianni, Kathy A.↗

Hypersonic Combustor Model Inlet CFD Simulations and Experimental Comparisons

Numerous two-and three-dimensional computational simulations were performed for the inlet associated with the combustor model for the hypersonic propulsion experiment in the NASA Ames 16-Inch Shock Tunnel. The inlet was designed to produce a combustor-inlet flow that is nearly two-dimensional and of sufficient mass flow rate for large scale combustor testing. The three-dimensional simulations demonstrated that the inlet design met all the design objectives and that the inlet produced a very nearly two-dimensional combustor inflow profile. Numerous two-dimensional simulations were performed with various levels of approximations such as in the choice of chemical and physical models, as well as numerical approximations. Parametric studies were conducted to better understand and to characterize the inlet flow. Results from the two-and three-dimensional simulations were used to predict the mass flux entering the combustor and a mass flux correlation as a function of facility stagnation pressure was developed. Surface heat flux and pressure measurements were compared with the computed results and good agreement was found. The computational simulations helped determine the inlet low characteristics in the high enthalpy environment, the important parameters that affect the combustor-inlet flow, and the sensitivity of the inlet flow to various modeling assumptions.

Venkatapathy, E.↗

Heat Integration Optimization and Dynamic Modeling Investigation for Advancing the Coal-Direct Chemical Looping Process

The purpose of the project is to address the optimization and startup operation of a modular coal direct chemical looping (CDCL) combustion system integrated with a steam cycle for power generation to reduce the risks involved in further scale-up of the technology. The modular reactor design of the CDCL process provides flexibility in the fabrication of the reactor and in its operating capacity (i.e. turndown ratio) at the cost of a more complex heat exchange network (HEN) design and integration. To address the technology gaps and advance the efficiency and economic feasibility of the CDCL technology, the project will perform a detailed and comprehensive analysis of the integration of a modular CDCL reactor system and a steam cycle system under both static and transient conditions via HEN process performance simulations and system dynamic modeling, respectively. The scope of work consists of 1) Experimental and computational studies of the CDCL combustor reactor 2) Comprehensive static (i.e. steady-state) system HEN design analysis in CDCL 550 MWe commercial unit for power generation and 3) Dynamic modeling of site specific design of 10MWe CDCL large pilot plant. The project team has successfully developed and validated a kinetic model for the oxidation of oxygen carriers in the combustor using the unreacted shrinking core model (UCSM). The model is capable of capturing the oxidation kinetics of fully or partially reduced oxygen carrier particles. A computational fluid dynamics (CFD) model is developed to simulate the hydrodynamics, heat transfer, and chemical reaction occurring in the CDCL combustor. The model is developed in MFIX and ANSYS Fluent. Key aspects of CDCL combustor operation, including heat transfer, oxygen carrier oxidation, and the transport of oxygen carrier particles, are simulated using this CFD model. The HEN for a commercial scale 550 MWe CDCL power plant is simulated and optimized using ASPEN Plus. Practical design considerations are incorporated based on industrial experiences. The performance and cost for the commercial CDCL plant is updated based on these analyses. A dynamic model for the 10 MWe CDCL pilot plant is developed in ProTRAX simulation software. The model is based on the pilot plant design developed in project DE-FE0027654 “10 MWe CDCL Large Pilot Plang – Pre-FEED Study” and the steam cycle data obtained from Dover Light & Power plant. The transient behaviors during pilot plant load variation are simulated using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

Comparison of Performance Test Results to CFD and Structural Models of Non-Contacting Finger Seals

Performance tests of non-contacting finger seal designs were conducted at 300, 700, 922 K (70, 800 and 1200 F) at pressure differentials up to 517 kPa (75 psid) and surface speeds up to 366 m/s (1200 ft/s). Room temperature, static analysis of the seal was performed. A simplified CFD model was developed to examine pressure loads within the seal. Results from the CFD model were used as input to a finite element analysis model of a six-finger segment of the non-contacting finger seal. Examination of predicted deflections of individual components of the seal gives insight into the seal behavior. Wear patterns from testing verify the pattern of radial deflection. The models are used to predict maximum pressure differential capability of the seal and compared to experimental results. The CFD model slightly under-predicts the measured leakage flow factor, but has the same trend as the measured flow factor versus pressure differential.

Seals:Brush Seals↗

Computational fluid dynamics investigations of flow, heat transfer, and oxidation in heat recovery steam generator

Modern heat recovery steam generators (HRSGs) operate at elevated temperatures, leading to the formation of oxides inside the tubes of heat exchangers (HXs). This oxide growth reduces the heat recovery efficiency. Moreover, after reaching a certain critical thickness, some oxide scales detach from the tube surface (exfoliation), causing erosion damage to the components downstream. Predicting the metal temperature distribution and associated oxide thickness in the HXs of an HRSG can aid in mitigating these problems. Here, a computational fluid dynamics (CFD) model was developed within the commercial code STAR-CCM+ for the prediction of fluid flow, conjugate heat transfer, and associated oxidation in HRSGs. Moreover, a new Porous Media Model (PMM) method was developed to model the fin effect on the heat transfer in HX, which can substantially reduce the prohibitive computational costs of fin meshes. The developed CFD model was used to conduct a high-fidelity simulation of a real-scale HRSG to investigate flow, heat transfer, and oxide growth. The calculated oxide thickness on different tubes can be used to identify HX regions that require oxide-resistant coatings to prevent exfoliation and ensuing damages. Furthermore, this CFD framework can serve as a reference for future studies that intend to model and investigate high-temperature oxidation in HXs used for any applications.

42 ENGINEERING↗