Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAT SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 {+-} 5.6 mm; range 1.5-25.0 mm) and diameter (mean, 13.5 {+-} 9.7 mm; range 2.2-41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implications of Artefacts Reduction in the Planning CT Originating from Implanted Fiducial Markers

The efficacy of metal artefact reduction (MAR) software to suppress artefacts in reconstructed computed tomography (CT) images originating from small metal objects, like tumor markers and surgical clips, was evaluated. In addition, possible implications of using digital reconstructed radiographs (DRRs), based on the MAR CT images, for setup verification were analyzed. A phantom and 15 patients with different tumor sites and implanted markers were imaged with a multislice CT scanner. The raw image data was reconstructed both with the clinically used filtered-backprojection (FBP) and with the MAR software. Using the MAR software, improvements in image quality were often observed in CT slices with markers or clips. Especially when several markers were located near to each other, fewer streak artefacts were observed than with the FBP algorithm. In addition, the shape and size of markers could be identified more accurately, reducing the contoured marker volumes by a factor of 2. For the phantom study, the CT numbers measured near to the markers corresponded more closely to the expected values. However, the MAR images were slightly more smoothed compared with the images reconstructed with FBP. For 8 prostate cancer patients in this study, the interobserver variation in 3D marker definition was similar (<0.4 mm) when using DRRs based on either FBP or MAR CT scans. Automatic marker matches also showed a similar success rate. However, differences in automatic match results up to 1 mm, caused by differences in the marker definition, were observed, which turned out to be (borderline) statistically significant (p = 0.06) for 2 patients. In conclusion, the MAR software might improve image quality by suppressing metal artefacts, probably allowing for a more reliable delineation of structures. When implanted markers or clips are used for setup verification, the accuracy may slightly be improved as well, which is relevant when using very tight clinical target volume (CTV) to planning target volume (PTV) margins for planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-91: Reproducibility in Prescribed Dose in AEC CT Scans Due to Table Height, Patient Size, and Localizer Acquisition Order

Purpose: In CT scanners, the automatic exposure control (AEC) tube current prescription depends on the acquired prescan localizer image(s). The purpose of this study was to quantify the effect that table height, patient size, and localizer acquisition order may have on the reproducibility in prescribed dose. Methods: Three phantoms were used for this study: the Mercury Phantom (comprises three tapered and four uniform regions of polyethylene 16, 23, 30, and 37 cm in diameter), acrylic sheets, and an adult anthropomorphic phantom. Phantoms were positioned per clinical protocol by our chief CT technologist or broader symmetry. Using a GE Discovery CT750HD scanner, a lateral (LAT) and posterior-anterior (PA) localizer was acquired for each phantom at different table heights. AEC scan acquisitions were prescribed for each combination of phantom, localizer orientation, and table height; the displayed volume CTDI was recorded for each. Results were analyzed versus table height. Results: For the two largest Mercury Phantom section scans based on the PA localizer, the percent change in volume CTDI from ideal were at least 20% lower and 35% greater for table heights 4 cm above and 4 cm below proper centering, respectively. For scans based on the LAT localizer, the percent change in volume CTDI from ideal were no greater than 12% different for 4 cm differences in table height. The properly centered PA and LAT localizer-based volume CTDI values were within 13% of each other. Conclusion: Since uncertainty in vertical patient positioning is inherently greater than lateral positioning and because the variability in dose exceeds any dose penalties incurred, the LAT localizer should be used to precisely and reproducibly deliver the intended amount of radiation prescribed by CT protocols. CT protocols can be adjusted to minimize the expected change in average patient dose.

60 APPLIED LIFE SCIENCES↗

Large scale validation of the M5L lung CAD on heterogeneous CT datasets

Purpose: M5L, a fully automated computer-aided detection (CAD) system for the detection and segmentation of lung nodules in thoracic computed tomography (CT), is presented and validated on several image datasets. Methods: M5L is the combination of two independent subsystems, based on the Channeler Ant Model as a segmentation tool [lung channeler ant model (lungCAM)] and on the voxel-based neural approach. The lungCAM was upgraded with a scan equalization module and a new procedure to recover the nodules connected to other lung structures; its classification module, which makes use of a feed-forward neural network, is based of a small number of features (13), so as to minimize the risk of lacking generalization, which could be possible given the large difference between the size of the training and testing datasets, which contain 94 and 1019 CTs, respectively. The lungCAM (standalone) and M5L (combined) performance was extensively tested on 1043 CT scans from three independent datasets, including a detailed analysis of the full Lung Image Database Consortium/Image Database Resource Initiative database, which is not yet found in literature. Results: The lungCAM and M5L performance is consistent across the databases, with a sensitivity of about 70% and 80%, respectively, at eight false positive findings per scan, despite the variable annotation criteria and acquisition and reconstruction conditions. A reduced sensitivity is found for subtle nodules and ground glass opacities (GGO) structures. A comparison with other CAD systems is also presented. Conclusions: The M5L performance on a large and heterogeneous dataset is stable and satisfactory, although the development of a dedicated module for GGOs detection could further improve it, as well as an iterative optimization of the training procedure. The main aim of the present study was accomplished: M5L results do not deteriorate when increasing the dataset size, making it a candidate for supporting radiologists on large scale screenings and clinical programs.

60 APPLIED LIFE SCIENCES↗

Salvage Treatment With Hypofractionated Radiotherapy in Patients With Recurrent Small Hepatocellular Carcinoma

Purpose: To investigate the rates of tumor response and local control in patients with recurrent small hepatocellular carcinoma (HCC) treated with hypofractionated radiotherapy (RT) as a salvage treatment and to evaluate treatment-related toxicities. Methods and Materials: Between 2006 and 2009, a total of 20 patients with recurrent small HCC were treated with hypofractionated RT after the failure of previous treatment. The eligibility criteria for hypofractionated RT were as follows: 1) HCC less than 5 cm, 2) HCC not adjacent to critical organs, 3) HCC without portal vein tumor thrombosis, and 4) less than 15% of normal liver volume that would be irradiated with 50% of prescribed dose. The RT dose was 50 Gy in 10 fractions. The tumor response was determined by CT scans performed 3 months after the end of RT. Results: The median follow-up period after RT was 22 months. The overall survival rates at 1 and 2 years were 100% and 87.9%, respectively. Complete response (CR) was achieved in seven of 20 lesions (35%) evaluated by CT scans performed 3 months after the end of RT. In-field local control was achieved in 85% of patients. Fourteen patients (70%) developed intra-hepatic metastases. Six patients developed grade 1 nausea or anorexia during RT, and two patients had progression of ascites after RT. There was no grade 3 or greater treatment-related toxicities. Conclusions: The current study showed a favorable outcome with respect to hypofractionated RT for small HCC. Partial liver irradiation with 50 Gy in 10 fractions is considered tolerable without severe complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: A feasibility study

Purpose: Certain types of commonly used fiducial markers take on irregular shapes upon implantation in soft tissue. This poses a challenge for methods that assume a predefined shape of markers when automatically tracking such markers in kilovoltage (kV) radiographs. The authors have developed a method of automatically tracking regularly and irregularly shaped markers using kV projection images and assessed its potential for detecting intrafractional target motion during rotational treatment. Methods: Template-based matching used a normalized cross-correlation with simplex minimization. Templates were created from computed tomography (CT) images for phantom studies and from end-expiration breath-hold planning CT for patient studies. The kV images were processed using a Sobel filter to enhance marker visibility. To correct for changes in intermarker relative positions between simulation and treatment that can introduce errors in automatic matching, marker offsets in three dimensions were manually determined from an approximately orthogonal pair of kV images. Two studies in anthropomorphic phantom were carried out, one using a gold cylindrical marker representing regular shape, another using a Visicoil marker representing irregular shape. Automatic matching of templates to cone beam CT (CBCT) projection images was performed to known marker positions in phantom. In patient data, automatic matching was compared to manual matching as an approximate ground truth. Positional discrepancy between automatic and manual matching of less than 2 mm was assumed as the criterion for successful tracking. Tracking success rates were examined in kV projection images from 22 CBCT scans of four pancreas, six gastroesophageal junction, and one lung cancer patients. Each patient had at least one irregularly shaped radiopaque marker implanted in or near the tumor. In addition, automatic tracking was tested in intrafraction kV images of three lung cancer patients with irregularly shaped markers during 11 volumetric modulated arc treatments. Purpose-built software developed at our institution was used to create marker templates and track the markers embedded in kV images. Results: Phantom studies showed mean ± standard deviation measurement uncertainty of automatic registration to be 0.14 ± 0.07 mm and 0.17 ± 0.08 mm for Visicoil and gold cylindrical markers, respectively. The mean success rate of automatic tracking with CBCT projections (11 frames per second, fps) of pancreas, gastroesophageal junction, and lung cancer patients was 100%, 99.1% (range 98%–100%), and 100%, respectively. With intrafraction images (approx. 0.2 fps) of lung cancer patients, the success rate was 98.2% (range 97%–100%), and 94.3% (range 93%–97%) using templates from 1.25 mm and 2.5 mm slice spacing CT scans, respectively. Correction of intermarker relative position was found to improve the success rate in two out of eight patients analyzed. Conclusions: The proposed method can track arbitrary marker shapes in kV images using templates generated from a breath-hold CT acquired at simulation. The studies indicate its feasibility for tracking tumor motion during rotational treatment. Investigation of the causes of misregistration suggests that its rate of incidence can be reduced with higher frequency of image acquisition, templates made from smaller CT slice spacing, and correction of changes in intermarker relative positions when they occur.

60 APPLIED LIFE SCIENCES↗

SU-F-18C-02: Evaluations of the Noise Power Spectrum of a CT Iterative Reconstruction Technique for Radiation Therapy

Purpose: To quantitatively assess the noise power spectrum (NPS) of the new, commercially released CT iterative reconstruction technique, iDose{sup 4} from Philips, to compare it with filtered back-projection techniques (FBP), and to provide clinical practice suggestions for radiation therapy. Methods: A uniform phantom was CT imaged with 120kVp tube potential over a range of mAs (250-3333). The image sets were reconstructed using two reconstruction algorithms (FBP and iDose{sup 4} with noise reduction levels 1, 3, and 6) and three reconstruction filters (standard B, smooth A, and sharp C), after which NPS variations were analyzed and compared on region of interest (ROI) sizes (16×16 to 128×128 pixels), ROI radii (0–65 mm), reconstruction algorithms, reconstruction filters, and mAs. Results: The NPS magnitude and shape depended considerably on ROI size and location for both reconstruction algorithms. Regional noise variance became more stationary as ROI size decreased, minimizing NPS artifacts. The optimal 32×32-pixel ROI size balanced the trade-off between stationary noise and adequate sampling. NPS artifacts were greatest at the center of reconstruction space and decreased with increasing ROI distance from the center. The optimal ROI position was located near the phantom's radial midpoint (∼40mm). For sharper filters, the NPS magnitude and the maximum magnitude frequency increased. Higher dose scans yielded lower NPS magnitudes for both reconstruction algorithms and all filters. Compared to FBP, the iDose{sup 4} algorithm reduced the NPS magnitude while preferentially reducing noise at mid-range spatial frequencies, altering noise texture. This reduction was more significant with increasing iDose{sup 4} noise reduction level. Conclusion: Compared to pixel standard deviation, NPS has greater clinical potential for task-based image quality assessment, describing both the magnitude and spatial frequency characteristics of image noise. While iDose{sup 4} reduces the NPS magnitude more dramatically than FBP, further studies are needed to assess the impacts of noise texture alteration on its clinical usage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfraction and Respiratory Organ Motion During Conformal Radiotherapy in Gastric Cancer

Purpose: To quantify the interfraction and breathing organ motion during adjuvant radiotherapy for gastric cancer and assess organ stability in different breathing states. Methods and Materials: A planning computed tomography (CT) scan and serial study CT scans in free breathing, voluntary inhale and exhale were performed in weeks 1, 3, and 5 of radiotherapy for 22 resected gastric patients. All data sets were fused to register the vertebral bodies. The regions of interest (kidneys, stomach, liver, pancreas, celiac axis, and porta hepatis) or points of interest (POIs; left dome of diaphragm, splenic hilum) were identified. For each region of interest, a POI was automatically placed at the center of mass. The interfraction displacement and breathing amplitude were assessed in the craniocaudal (CC), anteroposterior (AP), and right-left (RL) directions. Results: Comparison of the serial free-breathing CT scans with the planning CT scan showed a median displacement of all POIs of 5.6, 2.2, and 1.8 mm in the CC, AP, and RL directions, respectively. Comparison of the serial inhale scans with the first inhale scan showed a displacement of 4.9, 2.6, and 1.8 mm in the CC, AP, and RL directions, respectively. The comparable values for the exhale scans were 5.1, 2.0, and 1.8 mm. The displacements of the organs were similar in the free breathing, inhale, and exhale states. The median respiratory amplitude in the CC, AP, and RL direction was 14, 4.8, and 1.7 mm, respectively. Conclusion: The median interfraction displacement of the POIs relative to the vertebral bodies was about 6 mm in the CC direction and 2 mm in the other directions. The planning target volume margins need to account for these shifts. Individual assessment of respiratory motion is recommended to identify patients with unusually large respiratory amplitude.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing radiation dose to selected organs by selecting the tube start angle in MDCT helical scans: A Monte Carlo based study

Purpose: Previous work has demonstrated that there are significant dose variations with a sinusoidal pattern on the peripheral of a CTDI 32 cm phantom or on the surface of an anthropomorphic phantom when helical CT scanning is performed, resulting in the creation of ''hot'' spots or ''cold'' spots. The purpose of this work was to perform preliminary investigations into the feasibility of exploiting these variations to reduce dose to selected radiosensitive organs solely by varying the tube start angle in CT scans. Methods: Radiation dose to several radiosensitive organs (including breasts, thyroid, uterus, gonads, and eye lenses) resulting from MDCT scans were estimated using Monte Carlo simulation methods on voxelized patient models, including GSF's Baby, Child, and Irene. Dose to fetus was also estimated using four pregnant female models based on CT images of the pregnant patients. Whole-body scans were simulated using 120 kVp, 300 mAs, both 28.8 and 40 mm nominal collimations, and pitch values of 1.5, 1.0, and 0.75 under a wide range of start angles (0 deg. - 340 deg. in 20 deg. increments). The relationship between tube start angle and organ dose was examined for each organ, and the potential dose reduction was calculated. Results: Some organs exhibit a strong dose variation, depending on the tube start angle. For small peripheral organs (e.g., the eye lenses of the Baby phantom at pitch 1.5 with 40 mm collimation), the minimum dose can be 41% lower than the maximum dose, depending on the tube start angle. In general, larger dose reductions occur for smaller peripheral organs in smaller patients when wider collimation is used. Pitch 1.5 and pitch 0.75 have different mechanisms of dose reduction. For pitch 1.5 scans, the dose is usually lowest when the tube start angle is such that the x-ray tube is posterior to the patient when it passes the longitudinal location of the organ. For pitch 0.75 scans, the dose is lowest when the tube start angle is such that the x-ray tube is anterior to the patient when it passes the longitudinal location of the organ. Conclusions: Helical MDCT scanning at pitch 1.5 and pitch 0.75 results in ''cold spots'' and ''hot spots'' that are created both at surface and in-depth locations within patients. For organs that have a relatively small longitudinal extent, dose can vary considerably with different start angles. While current MDCT systems do not provide the user with the ability to control the tube start angle, these results indicate that in these specific situations (pitch 1.5 or pitch 0.75, small organs and especially small patients), there could be significant dose savings to organs if that functionality would be provided.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-E-17A-03: Monte Carlo CT Dose Calculation: A Comparison Between Experiment and Simulation Using ARCHER-CT

Purpose: To compare the CT doses derived from the experiments and GPU-based Monte Carlo (MC) simulations, using a human cadaver and ATOM phantom. Methods: The cadaver of an 88-year old male and the ATOM phantom were scanned by a GE LightSpeed Pro 16 MDCT. For the cadaver study, the Thimble chambers (Model 10×5−0.6CT and 10×6−0.6CT) were used to measure the absorbed dose in different deep and superficial organs. Whole-body scans were first performed to construct a complete image database for MC simulations. Abdomen/pelvis helical scans were then conducted using 120/100 kVps, 300 mAs and a pitch factor of 1.375:1. For the ATOM phantom study, the OSL dosimeters were used and helical scans were performed using 120 kVp and x, y, z tube current modulation (TCM). For the MC simulations, sufficient particles were run in both cases such that the statistical errors of the results by ARCHER-CT were limited to 1%. Results: For the human cadaver scan, the doses to the stomach, liver, colon, left kidney, pancreas and urinary bladder were compared. The difference between experiments and simulations was within 19% for the 120 kVp and 25% for the 100 kVp. For the ATOM phantom scan, the doses to the lung, thyroid, esophagus, heart, stomach, liver, spleen, kidneys and thymus were compared. The difference was 39.2% for the esophagus, and within 16% for all other organs. Conclusion: In this study the experimental and simulated CT doses were compared. Their difference is primarily attributed to the systematic errors of the MC simulations, including the accuracy of the bowtie filter modeling, and the algorithm to generate voxelized phantom from DICOM images. The experimental error is considered small and may arise from the dosimeters. R01 grant (R01EB015478) from National Institute of Biomedical Imaging and Bioengineering.

60 APPLIED LIFE SCIENCES↗

Metal artifact correction for x-ray computed tomography using kV and selective MV imaging

Purpose: The overall goal of this work is to improve the computed tomography (CT) image quality for patients with metal implants or fillings by completing the missing kilovoltage (kV) projection data with selectively acquired megavoltage (MV) data that do not suffer from photon starvation. When both of these imaging systems, which are available on current radiotherapy devices, are used, metal streak artifacts are avoided, and the soft-tissue contrast is restored, even for regions in which the kV data cannot contribute any information. Methods: Three image-reconstruction methods, including two filtered back-projection (FBP)-based analytic methods and one iterative method, for combining kV and MV projection data from the two on-board imaging systems of a radiotherapy device are presented in this work. The analytic reconstruction methods modify the MV data based on the information in the projection or image domains and then patch the data onto the kV projections for a FBP reconstruction. In the iterative reconstruction, the authors used dual-energy (DE) penalized weighted least-squares (PWLS) methods to simultaneously combine the kV/MV data and perform the reconstruction. Results: The authors compared kV/MV reconstructions to kV-only reconstructions using a dental phantom with fillings and a hip-implant numerical phantom. Simulation results indicated that dual-energy sinogram patch FBP and the modified dual-energy PWLS method can successfully suppress metal streak artifacts and restore information lost due to photon starvation in the kV projections. The root-mean-square errors of soft-tissue patterns obtained using combined kV/MV data are 10–15 Hounsfield units smaller than those of the kV-only images, and the structural similarity index measure also indicates a 5%–10% improvement in the image quality. The added dose from the MV scan is much less than the dose from the kV scan if a high efficiency MV detector is assumed. Conclusions: The authors have shown that it is possible to improve the image quality of kV CTs for patients with metal implants or fillings by completing the missing kV projection data with selectively acquired MV data that do not suffer from photon starvation. Numerical simulations demonstrated that dual-energy sinogram patch FBP and a modified kV/MV PWLS method can successfully suppress metal streak artifacts and restore information lost due to photon starvation in kV projections. Combined kV/MV images may permit the improved delineation of structures of interest in CT images for patients with metal implants or fillings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A “loop” shape descriptor and its application to automated segmentation of airways from CT scans

Purpose: A novel shape descriptor is presented to aid an automated identification of the airways depicted on computed tomography (CT) images. Methods: Instead of simplifying the tubular characteristic of the airways as an ideal mathematical cylindrical or circular shape, the proposed “loop” shape descriptor exploits the fact that the cross sections of any tubular structure (regardless of its regularity) always appear as a loop. In implementation, the authors first reconstruct the anatomical structures in volumetric CT as a three-dimensional surface model using the classical marching cubes algorithm. Then, the loop descriptor is applied to locate the airways with a concave loop cross section. To deal with the variation of the airway walls in density as depicted on CT images, a multiple threshold strategy is proposed. A publicly available chest CT database consisting of 20 CT scans, which was designed specifically for evaluating an airway segmentation algorithm, was used for quantitative performance assessment. Measures, including length, branch count, and generations, were computed under the aid of a skeletonization operation. Results: For the test dataset, the airway length ranged from 64.6 to 429.8 cm, the generation ranged from 7 to 11, and the branch number ranged from 48 to 312. These results were comparable to the performance of the state-of-the-art algorithms validated on the same dataset. Conclusions: The authors’ quantitative experiment demonstrated the feasibility and reliability of the developed shape descriptor in identifying lung airways.

60 APPLIED LIFE SCIENCES↗

Computed Tomography–Guided Interstitial High-Dose-Rate Brachytherapy in Combination With Regional Positive Lymph Node Intensity-Modulated Radiation Therapy in Locally Advanced Peripheral Non–Small Cell Lung Cancer: A Phase 1 Clinical Trial

Purpose: To assess the technical safety, adverse events, and efficacy of computed tomography (CT)-guided interstitial high-dose-rate (HDR) brachytherapy in combination with regional positive lymph node intensity modulated radiation therapy in patients with locally advanced peripheral non–small cell lung cancer (NSCLC). Methods and Materials: Twenty-six patients with histologically confirmed NSCLC were enrolled in a prospective, officially approved phase 1 trial. Primary tumors were treated with HDR brachytherapy. A single 30-Gy dose was delivered to the 90% isodose line of the gross lung tumor volume. A total dose of at least 70 Gy was administered to the 95% isodose line of the planning target volume of malignant lymph nodes using 6-MV X-rays. The patients received concurrent or sequential chemotherapy. We assessed treatment efficacy, adverse events, and radiation toxicity. Results: The median follow-up time was 28 months (range, 7-44 months). There were 3 cases of mild pneumothorax but no cases of hemothorax, dyspnea, or pyothorax after the procedure. Grade 3 or 4 acute hematologic toxicity was observed in 5 patients. During follow-up, mild fibrosis around the puncture point was observed on the CT scans of 2 patients, but both patients were asymptomatic. The overall response rates (complete and partial) for the primary mass and positive lymph nodes were 100% and 92.3%, respectively. The 1-year and 2-year overall survival (OS) rates were 90.9% and 67%, respectively, with a median OS of 22.5 months. Conclusion: Our findings suggest that HDR brachytherapy is safe and feasible for peripheral locally advanced NSCLC, justifying a phase 2 clinical trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-A-18C-10: Dynamic Intensity Weighted Region of Interest Imaging

Purpose: For image guidance tasks full image quality is not required throughout the entire image. With dynamic filtration of the kV imaging beam the noise properties of the CT image can be locally controlled, providing a high quality image around the target volume with a lower quality surrounding region while providing substantial dose sparing to the patient as well as reduced scatter fluence on the detector. Methods: A dynamic collimation device with 3mm copper blades has been designed to mount in place of the bowtie filter on the On-Board Imager (Varian Medical Systems). The beam intensity is reduced by 95% behind the copper filters and the aperture is controlled dynamically to conformally illuminate a given ROI during a standard cone-beam CT scan. A data correction framework to account for the physical effects of the collimator prior to reconstruction was developed. Furthermore, to determine the dose savings and scatter reduction a monte carlo model was built in BEAMnrc with specifics from the Varian Monte Carlo Data Package. The MC model was validated with Gafchromic film. Results: The reconstructed image shows image quality comparable to a standard scan in the specified ROI, with higher noise and streaks in the outer region but still sufficient information for alignment to high contrast structures. The monte carlo modeling showed that the scatter-to-primary ratio was reduced from 1.26 for an unfiltered scan to 0.45 for an intensity weighted scan, suggesting that image quality may be improved in the inner ROI. Dose in the inner region was reduced 10–15% due to reduced scatter and by as much as 75% in the outer region. Conclusion: Dynamic intensity-weighted ROI imaging allows reduction of imaging dose to sensitive organs away from the target region while providing images that retain their utility for patient setup and procedure guidance. Funding was provided in part by Varian Medical Systems and NIH Grants 1RO1CA120540, T32EB002103, S10 RR021039 and P30 CA14599. The contents of this work are solely the responsibility of the authors and do not necessarily represent the official views of any of the supporting organizations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-433: Calibration Accuracy in Mailed High-Resolution 3D Dosimetry Service for SRS/SBRT QA

Purpose: SRS/SBRT combines hypofractionation with excellent dose distributions. However, extremely steep gradients across the target along with dose escalation, if not administered accurately, may lead to serious complications, recurrences, or even fatalities. Existing commercial QA products either lack adequate spatial resolution or the 3D aspect. By contrast, the new CrystalBall™ mailed high-resolution 3D dosimetry service removes the above limitations while reducing the overall workload on medical physics staff. The exposed dosimeters, which change optical density in proportion to local dose, are sent back to the manufacturer (MGS Research Inc., Madison, CT) for sub-millimeter-resolution laser-CT scanning and QA data analysis. QA report is returned electronically within 24 hours. The purpose of this study was to evaluate the dose calibration accuracy in this system. Methods: Two spherical CrystalBall™ polymer gel dosimeters from the same batch, 166 mm diameter, with embedded 3D image registration markers, were mounted in a special phantom designed for reproducible positioning. For full end to end testing, the optical guidance array was mounted onto the phantom and a CT was taken. Two separate Rapid Arc SRS plans were designed. Varian Medical Systems optical guidance system was used to position the phantom and the SRS treatment plans were delivered to the two spheres on Varian's Trilogy Accelerator. Exposed dosimeters were mailed back to the manufacturer for laser CT scanning and analysis. Results: For each plan, 3D gamma passing rate was 100% for 2%/2mm distance-to-agreement criteria above 50% isodose level. The two calibration curves, generated using volumetric dose and optical density data, showed excellent mutual agreement (max difference 2.2%, median difference 0.75%). Conclusion: The clinical utility of new CrystalBall™ mailed QA service for SRS/SBRT and high accuracy of dose calibration have been validated. The workflow associated with the use of the CrystalBall™ in clinical setting was found to be minimal. The presenting author is the founder of and has an ownership in MGS Research Inc which manufactures the CrystalBall system for 3D dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time

The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 days post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm{sup 3} (4–118) and CT2ch: median 16 cm{sup 3}, (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of setup error using different reference images: a phantom and lung cancer patients study

The purpose of this study was to compare setup errors obtained with kilovoltage cone-beam computed tomography (CBCT) and 2 different kinds of reference images, free-breathing 3D localization CT images (FB-CT) and the average images of 4-D localization CT images (AVG-CT) for phantom and lung cancer patients. This study also explored the correlation between the difference of translational setup errors and the gross tumor volume (GTV) motion. A respiratory phantom and 14 patients were enrolled in this study. For phantom and each patient, 3D helical CT and 4D CT images were acquired, and AVG-CT images were generated from the 4D CT. The setup errors were determined based on the image registration between the CBCT and the 2 different reference images, respectively. The data for both translational and rotational setup errors were analyzed and compared. The GTV centroid movement as well as its correlation with the translational setup error differences was also evaluated. In the phantom study, the AVG-CT method was more accurate than the FB-CT method. For patients, the translational setup errors based on FB-CT were significantly larger than those from AVG-CT in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions (p < 0.05). Translational setup errors differed by >1 mm in 32.6% and >2 mm in 12.9% of CBCT scans. The rotational setup errors from FB-CT were significantly different from those from AVG-CT in the LR and AP directions (p < 0.05). The correlation coefficient of the translational setup error differences and the GTV centroid movement in the LR, SI, and AP directions was 0.515 (p = 0.060), 0.902 (p < 0.001), and 0.510 (p = 0.062), respectively. For lung cancer patients, respiration may affect the on-line target position location. AVG-CT provides different reference information than FB-CT. The difference in SI direction caused by the 2 methods increases with the GTV movement. Therefore, AVG-CT should be the prefered choice of reference images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Calibration of helical tomotherapy machine using EPR/alanine dosimetry

Purpose: Current codes of practice for clinical reference dosimetry of high-energy photon beams in conventional radiotherapy recommend using a 10x10 cm{sup 2} square field, with the detector at a reference depth of 10 cm in water and 100 cm source to surface distance (SSD) (AAPM TG-51) or 100 cm source-to-axis distance (SAD) (IAEA TRS-398). However, the maximum field size of a helical tomotherapy (HT) machine is 40x5 cm{sup 2} defined at 85 cm SAD. These nonstandard conditions prevent a direct implementation of these protocols. The purpose of this study is twofold: To check the absorbed dose in water and dose rate calibration of a tomotherapy unit as well as the accuracy of the tomotherapy treatment planning system (TPS) calculations for a specific test case. Method: Both topics are based on the use of electron paramagnetic resonance (EPR) using alanine as transfer dosimeter between the Laboratoire National Henri Becquerel (LNHB) {sup 60}Co-{gamma}-ray reference beam and the Institut Curie's HT beam. Irradiations performed in the LNHB reference {sup 60}Co-{gamma}-ray beam allowed setting up the calibration method, which was then implemented and tested at the LNHB 6 MV linac x-ray beam, resulting in a deviation of 1.6% (at a 1% standard uncertainty) relative to the reference value determined with the standard IAEA TRS-398 protocol. Results: HT beam dose rate estimation shows a difference of 2% with the value stated by the manufacturer at a 2% standard uncertainty. A 4% deviation between measured dose and the calculation from the tomotherapy TPS was found. The latter was originated by an inadequate representation of the phantom CT-scan values and, consequently, mass densities within the phantom. This difference has been explained by the mass density values given by the CT-scan and used by the TPS which were not the true ones. Once corrected using Monte Carlo N-Particle simulations to validate the accuracy of this process, the difference between corrected TPS calculations and alanine measured dose values was then found to be around 2% (with 2% standard uncertainty on TPS doses and 1.5% standard uncertainty on EPR measurements). Conclusion: Beam dose rate estimation results were found to be in good agreement with the reference value given by the manufacturer at 2% standard uncertainty. Moreover, the dose determination method was set up with a deviation around 2% (at a 2% standard uncertainty).

61 RADIATION PROTECTION AND DOSIMETRY↗