Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CARLO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Dose Calculation Accuracy of the Monte Carlo Algorithm for CyberKnife Compared with Other Commercially Available Dose Calculation Algorithms

Monte Carlo dose calculation algorithms have the potential for greater accuracy than traditional model-based algorithms. This enhanced accuracy is particularly evident in regions of lateral scatter disequilibrium, which can develop during treatments incorporating small field sizes and low-density tissue. A heterogeneous slab phantom was used to evaluate the accuracy of several commercially available dose calculation algorithms, including Monte Carlo dose calculation for CyberKnife, Analytical Anisotropic Algorithm and Pencil Beam convolution for the Eclipse planning system, and convolution-superposition for the Xio planning system. The phantom accommodated slabs of varying density; comparisons between planned and measured dose distributions were accomplished with radiochromic film. The Monte Carlo algorithm provided the most accurate comparison between planned and measured dose distributions. In each phantom irradiation, the Monte Carlo predictions resulted in gamma analysis comparisons >97%, using acceptance criteria of 3% dose and 3-mm distance to agreement. In general, the gamma analysis comparisons for the other algorithms were <95%. The Monte Carlo dose calculation algorithm for CyberKnife provides more accurate dose distribution calculations in regions of lateral electron disequilibrium than commercially available model-based algorithms. This is primarily because of the ability of Monte Carlo algorithms to implicitly account for tissue heterogeneities, density scaling functions; and/or effective depth correction factors are not required.

61 RADIATION PROTECTION AND DOSIMETRY↗

Commissioning of a Varian Clinac iX 6 MV photon beam using Monte Carlo simulation

Monte Carlo modelling of a linear accelerator is the first and most important step in Monte Carlo dose calculations in radiotherapy. Monte Carlo is considered today to be the most accurate and detailed calculation method in different fields of medical physics. In this research, we developed a photon beam model for Varian Clinac iX 6 MV equipped with MilleniumMLC120 for dose calculation purposes using BEAMnrc/DOSXYZnrc Monte Carlo system based on the underlying EGSnrc particle transport code. Monte Carlo simulation for this commissioning head LINAC divided in two stages are design head Linac model using BEAMnrc, characterize this model using BEAMDP and analyze the difference between simulation and measurement data using DOSXYZnrc. In the first step, to reduce simulation time, a virtual treatment head LINAC was built in two parts (patient-dependent component and patient-independent component). The incident electron energy varied 6.1 MeV, 6.2 MeV and 6.3 MeV, 6.4 MeV, and 6.6 MeV and the FWHM (full width at half maximum) of source is 1 mm. Phase-space file from the virtual model characterized using BEAMDP. The results of MC calculations using DOSXYZnrc in water phantom are percent depth doses (PDDs) and beam profiles at depths 10 cm were compared with measurements. This process has been completed if the dose difference of measured and calculated relative depth-dose data along the central-axis and dose profile at depths 10 cm is ≤ 5%. The effect of beam width on percentage depth doses and beam profiles was studied. Results of the virtual model were in close agreement with measurements in incident energy electron 6.4 MeV. Our results showed that photon beam width could be tuned using large field beam profile at the depth of maximum dose. The Monte Carlo model developed in this study accurately represents the Varian Clinac iX with millennium MLC 120 leaf and can be used for reliable patient dose calculations. In this commissioning process, the good criteria of dose difference in PDD and dose profiles were achieve using incident electron energy 6.4 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

A NEW MONTE CARLO METHOD FOR TIME-DEPENDENT NEUTRINO RADIATION TRANSPORT

Monte Carlo approaches to radiation transport have several attractive properties such as simplicity of implementation, high accuracy, and good parallel scaling. Moreover, Monte Carlo methods can handle complicated geometries and are relatively easy to extend to multiple spatial dimensions, which makes them potentially interesting in modeling complex multi-dimensional astrophysical phenomena such as core-collapse supernovae. The aim of this paper is to explore Monte Carlo methods for modeling neutrino transport in core-collapse supernovae. We generalize the Implicit Monte Carlo photon transport scheme of Fleck and Cummings and gray discrete-diffusion scheme of Densmore et al. to energy-, time-, and velocity-dependent neutrino transport. Using our 1D spherically-symmetric implementation, we show that, similar to the photon transport case, the implicit scheme enables significantly larger timesteps compared with explicit time discretization, without sacrificing accuracy, while the discrete-diffusion method leads to significant speed-ups at high optical depth. Our results suggest that a combination of spectral, velocity-dependent, Implicit Monte Carlo and discrete-diffusion Monte Carlo methods represents a robust approach for use in neutrino transport calculations in core-collapse supernovae. Our velocity-dependent scheme can easily be adapted to photon transport.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo modeling of small photon fields: Quantifying the impact of focal spot size on source occlusion and output factors, and exploring miniphantom design for small-field measurements

The accuracy with which Monte Carlo models of photon beams generated by linear accelerators (linacs) can describe small-field dose distributions depends on the modeled width of the electron beam profile incident on the linac target. It is known that the electron focal spot width affects penumbra and cross-field profiles; here, the authors explore the extent to which source occlusion reduces linac output for smaller fields and larger spot sizes. A BEAMnrc Monte Carlo linac model has been used to investigate the variation in penumbra widths and small-field output factors with electron spot size. A formalism is developed separating head scatter factors into source occlusion and flattening filter factors. Differences between head scatter factors defined in terms of in-air energy fluence, collision kerma, and terma are explored using Monte Carlo calculations. Estimates of changes in kerma-based source occlusion and flattening filter factors with field size and focal spot width are obtained by calculating doses deposited in a narrow 2 mm wide virtual ''milliphantom'' geometry. The impact of focal spot size on phantom scatter is also explored. Modeled electron spot sizes of 0.4-0.7 mm FWHM generate acceptable matches to measured penumbra widths. However the 0.5 cm field output factor is quite sensitive to electron spot width, the measured output only being matched by calculations for a 0.7 mm spot width. Because the spectra of the unscattered primary ({Psi}{sub {Pi}}) and head-scattered ({Psi}{sub {Sigma}}) photon energy fluences differ, miniphantom-based collision kerma measurements do not scale precisely with total in-air energy fluence {Psi}=({Psi}{sub {Pi}}+{Psi}{sub {Sigma}}) but with ({Psi}{sub {Pi}}+1.2{Psi}{sub {Sigma}}). For most field sizes, on-axis collision kerma is independent of the focal spot size; but for a 0.5 cm field size and 1.0 mm spot width, it is reduced by around 7% mostly due to source occlusion. The phantom scatter factor of the 0.5 cm field also shows some spot size dependence, decreasing by 6% (relative) as spot size is increased from 0.1 to 1.0 mm. The dependence of small-field source occlusion and output factors on the focal spot size makes this a significant factor in Monte Carlo modeling of small (<1 cm) fields. Changes in penumbra width with spot size are not sufficiently large to accurately pinpoint spot widths. Consequently, while Monte Carlo models based exclusively on large-field data can quite accurately predict small-field profiles and PDDs, in the absence of experimental methods of determining incident electron beam profiles it will remain necessary to measure small-field output factors, fine-tuning modeled spot sizes to ensure good matching between the Monte Carlo and the measured output factors.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac

Purpose: To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for rendering the phase-space data compatible with BEAMnrc/DOSXYZnrc simulation software package is presented. Methods: Monte Carlo (MC) simulations were performed to benchmark the TrueBeam 6 MV FFF phase space data that have been released by the Varian MC Research team. The simulations to benchmark the phase space data were done in three steps. First, the original phase space which was created on a cylindrical surface was converted into a format that was compatible with BEAMnrc. Second, BEAMnrc was used to create field size specific phase spaces located underneath the jaws. Third, doses were calculated with DOSXYZnrc in a water phantom for fields ranging from 1 Multiplication-Sign 1 to 40 Multiplication-Sign 40 cm{sup 2}. Calculated percent depth doses (PDD), transverse profiles, and output factors were compared with measurements for all the fields simulated. After completing the benchmarking study, three stereotactic body radiotherapy (SBRT) VMAT plans created with the Eclipse treatment planning system (TPS) were calculated with Monte Carlo. Ion chamber and film measurements were also performed on these plans. 3D gamma analysis was used to compare Monte Carlo calculation with TPS calculations and with film measurement. Results: For the benchmarking study, MC calculated and measured values agreed within 1% and 1.5% for PDDs and in-field transverse profiles, respectively, for field sizes >1 Multiplication-Sign 1 cm{sup 2}. Agreements in the 80%-20% penumbra widths were better than 2 mm for all the fields that were compared. With the exception of the 1 Multiplication-Sign 1 cm{sup 2} field, the agreement between measured and calculated output factors was within 1%. It is of note that excellent agreement in output factors for all field sizes including highly asymmetric fields was achieved without accounting for backscatter into the beam monitor chamber. For the SBRT VMAT plans, the agreement between Monte Carlo and ion chamber point dose measurements was within 1%. Excellent agreement between Monte Carlo, treatment planning system and Gafchromic film dose distribution was observed with over 99% of the points in the high dose volume passing the 3%, 3 mm gamma test. Conclusions: The authors have presented a method for making the Varian IAEA compliant 6 MV FFF phase space file of the TrueBeam linac compatible with BEAMnrc/DOSXYZnrc. After benchmarking the modified phase space against measurement, they have demonstrated its potential for use in MC based quality assurance of complex delivery techniques.

60 APPLIED LIFE SCIENCES↗

SU-E-T-222: Computational Optimization of Monte Carlo Simulation On 4D Treatment Planning Using the Cloud Computing Technology

Purpose: This study evaluated the efficiency of 4D lung radiation treatment planning using Monte Carlo simulation on the cloud. The EGSnrc Monte Carlo code was used in dose calculation on the 4D-CT image set. Methods: 4D lung radiation treatment plan was created by the DOSCTP linked to the cloud, based on the Amazon elastic compute cloud platform. Dose calculation was carried out by Monte Carlo simulation on the 4D-CT image set on the cloud, and results were sent to the FFD4D image deformation program for dose reconstruction. The dependence of computing time for treatment plan on the number of compute node was optimized with variations of the number of CT image set in the breathing cycle and dose reconstruction time of the FFD4D. Results: It is found that the dependence of computing time on the number of compute node was affected by the diminishing return of the number of node used in Monte Carlo simulation. Moreover, the performance of the 4D treatment planning could be optimized by using smaller than 10 compute nodes on the cloud. The effects of the number of image set and dose reconstruction time on the dependence of computing time on the number of node were not significant, as more than 15 compute nodes were used in Monte Carlo simulations. Conclusion: The issue of long computing time in 4D treatment plan, requiring Monte Carlo dose calculations in all CT image sets in the breathing cycle, can be solved using the cloud computing technology. It is concluded that the optimized number of compute node selected in simulation should be between 5 and 15, as the dependence of computing time on the number of node is significant.

60 APPLIED LIFE SCIENCES↗

SU-E-T-519: Investigation of the CyberKnife MultiPlan Monte Carlo Dose Calculation Using EBT3 Film Absolute Dosimetry for Delivery in a Heterogeneous Thorax Phantom

Purpose To characterize the Cyberknife (CK) robotic system’s dosimetric accuracy of the delivery of MultiPlan’s Monte Carlo dose calculations using EBT3 radiochromic film inserted in a thorax phantom. Methods The CIRS XSight Lung Tracking (XLT) Phantom (model 10823) was used in this study with custom cut EBT3 film inserted in the horizontal (coronal) plane inside the lung tissue equivalent phantom. CK MultiPlan v3.5.3 with Monte Carlo dose calculation algorithm (1.5 mm grid size, 2% statistical uncertainty) was used to calculate a clinical plan for a 25-mm lung tumor lesion, as contoured by the physician, and then imported onto the XLT phantom CT. Using the same film batch, the net OD to dose calibration curve was obtained using CK with the 60 mm fixed cone by delivering 0– 800 cGy. The test films (n=3) were irradiated using 325 cGy to the prescription point. Films were scanned 48 hours after irradiation using an Epson v700 scanner (48 bits color scan, extracted red channel only, 96 dpi). Percent absolute dose and relative isodose distribution difference relative to the planned dose were quantified using an in-house QA software program. Multiplan Monte Carlo dose calculation was validated using RCF dosimetry (EBT3) and gamma index criteria of 3%/3mm and 2%/2mm for absolute dose and relative isodose distribution measurement comparisons. Results EBT3 film measurements of the patient plans calculated with Monte Carlo in MultiPlan resulted in an absolute dose passing rate of 99.6±0.4% for the Gamma Index of 3%/3mm, 10% dose threshold, and 95.6±4.4% for 2%/2mm, 10% threshold criteria. The measured central axis absolute dose was within 1.2% (329.0±2.5 cGy) of the Monte Carlo planned dose (325.0±6.5 cGy) for that same point. Conclusion MultiPlan’s Monte Carlo dose calculation was validated using the EBT3 film absolute dosimetry for delivery in a heterogeneous thorax phantom.

60 APPLIED LIFE SCIENCES↗

Monte Carlo simulations of {sup 3}He ion physical characteristics in a water phantom and evaluation of radiobiological effectiveness

Purpose: {sup 3}He ions may hold great potential for clinical therapy because of both their physical and biological properties. In this study, the authors investigated the physical properties, i.e., the depth-dose curves from primary and secondary particles, and the energy distributions of helium ({sup 3}He) ions. A relative biological effectiveness (RBE) model was applied to assess the biological effectiveness on survival of multiple cell lines. Methods: In light of the lack of experimental measurements and cross sections, the authors used Monte Carlo methods to study the energy deposition of {sup 3}He ions. The transport of {sup 3}He ions in water was simulated by using three Monte Carlo codes—FLUKA, GEANT4, and MCNPX—for incident beams with Gaussian energy distributions with average energies of 527 and 699 MeV and a full width at half maximum of 3.3 MeV in both cases. The RBE of each was evaluated by using the repair-misrepair-fixation model. In all of the simulations with each of the three Monte Carlo codes, the same geometry and primary beam parameters were used. Results: Energy deposition as a function of depth and energy spectra with high resolution was calculated on the central axis of the beam. Secondary proton dose from the primary {sup 3}He beams was predicted quite differently by the three Monte Carlo systems. The predictions differed by as much as a factor of 2. Microdosimetric parameters such as dose mean lineal energy (y{sub D}), frequency mean lineal energy (y{sub F}), and frequency mean specific energy (z{sub F}) were used to characterize the radiation beam quality at four depths of the Bragg curve. Calculated RBE values were close to 1 at the entrance, reached on average 1.8 and 1.6 for prostate and head and neck cancer cell lines at the Bragg peak for both energies, but showed some variations between the different Monte Carlo codes. Conclusions: Although the Monte Carlo codes provided different results in energy deposition and especially in secondary particle production (most of the differences between the three codes were observed close to the Bragg peak, where the energy spectrum broadens), the results in terms of RBE were generally similar.

61 RADIATION PROTECTION AND DOSIMETRY↗

Diagnosing Undersampling Biases in Monte Carlo Eigenvalue and Flux Tally Estimates

Here, this study focuses on understanding the phenomena in Monte Carlo simulations known as undersampling, in which Monte Carlo tally estimates may not encounter a sufficient number of particles during each generation to obtain unbiased tally estimates. Steady-state Monte Carlo simulations were performed using the KENO Monte Carlo tools within the SCALE code system for models of several burnup credit applications with varying degrees of spatial and isotopic complexities, and the incidence and impact of undersampling on eigenvalue and flux estimates were examined. Using an inadequate number of particle histories in each generation was found to produce a maximum bias of ~100 pcm in eigenvalue estimates and biases that exceeded 10% in fuel pin flux tally estimates. Having quantified the potential magnitude of undersampling biases in eigenvalue and flux tally estimates in these systems, this study then investigated whether Markov Chain Monte Carlo convergence metrics could be integrated into Monte Carlo simulations to predict the onset and magnitude of undersampling biases. Five potential metrics for identifying undersampling biases were implemented in the SCALE code system and evaluated for their ability to predict undersampling biases by comparing the test metric scores with the observed undersampling biases. Finally, of the five convergence metrics that were investigated, three (the Heidelberger-Welch relative half-width, the Gelman-Rubin $\hat{R}_c$ diagnostic, and tally entropy) showed the potential to accurately predict the behavior of undersampling biases in the responses examined.

97 MATHEMATICS AND COMPUTING↗

A multi-group Monte Carlo core analysis method and its application in SCWR design

Complex geometry and spectrum have been the characteristics of many newly developed nuclear energy systems, so the suitability and precision of the traditional deterministic codes are doubtable while being applied to simulate these systems. On the contrary, the Monte Carlo method has the inherent advantages of dealing with complex geometry and spectrum. The main disadvantage of Monte Carlo method is that it takes long time to get reliable results, so the efficiency is too low for the ordinary core designs. A new Monte Carlo core analysis scheme is developed, aimed to increase the calculation efficiency. It is finished in two steps: Firstly, the assembly level simulation is performed by continuous energy Monte Carlo method, which is suitable for any geometry and spectrum configuration, and the assembly multi-group constants are tallied at the same time; Secondly, the core level calculation is performed by multi-group Monte Carlo method, using the assembly group constants generated in the first step. Compared with the heterogeneous Monte Carlo calculations of the whole core, this two-step scheme is more efficient, and the precision is acceptable for the preliminary analysis of novel nuclear systems. Using this core analysis scheme, a SCWR core was designed based on a new SCWR assembly design. The core output is about 1,100 MWe, and a cycle length of about 550 EFPDs can be achieved with 3-batch refueling pattern. The average and maximum discharge burn-up are about 53.5 and 60.9 MWD/kgU respectively. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Monte Carlo burnup code acceleration with the correlated sampling method. Preliminary test on an UOX cell with TRIPOLI-4{sup R}

For several years, Monte Carlo burnup/depletion codes have appeared, which couple a Monte Carlo code to simulate the neutron transport to a deterministic method that computes the medium depletion due to the neutron flux. Solving Boltzmann and Bateman equations in such a way allows to track fine 3 dimensional effects and to get rid of multi-group hypotheses done by deterministic solvers. The counterpart is the prohibitive calculation time due to the time-expensive Monte Carlo solver called at each time step. Therefore, great improvements in term of calculation time could be expected if one could get rid of Monte Carlo transport sequences. For example, it may seem interesting to run an initial Monte Carlo simulation only once, for the first time/burnup step, and then to use the concentration perturbation capability of the Monte Carlo code to replace the other time/burnup steps (the different burnup steps are seen like perturbations of the concentrations of the initial burnup step). This paper presents some advantages and limitations of this technique and preliminary results in terms of speed up and figure of merit. Finally, we will detail different possible calculation scheme based on that method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

GPU Acceleration of History-Based Multigroup Monte Carlo

Accurate solutions of the radiation transport equation play an important role in the analysis of many nuclear systems. Because there is no need to discretize the problem, Monte Carlo methods offer the most accurate possible solutions to the transport equation. However, significant computational effort is required to reduce the stochastic noise inherent to Monte Carlo methods. Current trends in high performance computing are moving towards vectorized, single instruction multiple data (SIMD), architectures such as Intel Xeon Phis and graphics processing units (GPUs) due to their favorable ratio of performance to power consumption. The challenge of adapting Monte Carlo transport to vectorized computing architectures was first addressed by Brown with an algorithm known as event-based Monte Carlo. In this approach, rather than simulating individual particle histories from birth to death, groups of particles are processed one event at a time. This allows each event batch to perform the same operations in lockstep, enabling use of the vector hardware. Although modern vectorized hardware is more versatile than the early vector machines, reducing so-called thread divergence is nonetheless still an important consideration for algorithm design. Many of the algorithms proposed so far for Monte Carlo transport on advanced architectures have focused on variants of event-based transport. Some evidence, however, suggests that low-level thread divergence, resulting from short-lived branching statements, may not be detrimental to overall performance on GPUs as long as the effect on achievable memory bandwidth is considered. This paper characterizes the performance of a traditional history-based Monte Carlo algorithm on GPUs. We show that with only minor modifications to traditional algorithms, significant performance gains relative to CPUs are possible. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo Direct Simulation Method for Initiation Probability Problems

During the early period of a supercritical system, the growth of fission chains shows a significant stochastic feature. In multiplying medium, it is a probability issue of fail-pass type for a single neutron to sponsor a divergent fission chain, and the probability of success is named as single neutron initiation probability. Meanwhile, in the presence of a weak neutron source, the time at which fission burst occurs also exhibits a stochastic nature, which can be observed on experiments of pulsed reactors such as GODIVA I and GODIVA II. The initiation probability and burst waiting time reflect the dynamic feature of a supercritical system, which are very important for nuclear criticality safety concerns. It is desirable that a supercritical system has an initiation probability very close to zero and releases limited energy in case of criticality accidents. The stochastic process of neutron population evolution in early age in a multiplying system is governed by Bell's equation in the form of an adjoint neutron transport equation with a non-linear fission term. In order to solve this stochastic neutron transport equation, the deterministic method discretizing the phase space was proposed long ago and has been implemented in several SN codes such as Partisn, Ardra and PANDA. However, the deterministic method is of limited usage, due to its poor ability to precisely describe real-world 3D complex geometries and continuous energy neutron spectrum. Recently, Monte Carlo methods have gradually gained attention for solving Bell's equation. Greenman from LLNL proposed an analog Monte Carlo forward-transport method for calculating initiation probability in 2007. He implemented this method by introducing the maximum age parameter, the time sub-interval and the neutron progenitor tag into Mercury in time-dependent fixed-source simulation mode. This method is only suitable for initiation probability calculations, however not for analyzing the randomness of burst waiting time. Later, GANG in 2011 developed the GSMP (Generalized Semi-Markov Process method) Monte Carlo method according to Bell's equation. While the GSMP method, which can deal with both initiation probability and burst waiting time, is flexible and powerful for zero-dimensional problems, it is not favorable when extended to 3D and continuous energy problems due to severe lack of computational efficiency. In 2015, a direct Monte Carlo simulation method for stochastic systems problems was implemented in MCATK, yet this method has not been applied specifically to the burst waiting time. In this work, a new and efficient 3D Monte Carlo direct simulation method for calculating both the initiation probability and the burst waiting time is developed. By taking random factors during evolvement of fission chains into account in dynamic Monte Carlo simulation, this new method has the potential of simulating the whole process from source neutron injection to exponential growth of the neutron population, and finally to extinction of the neutron pulse. This capability is useful in criticality accidents evaluation and pulsed reactor experiments explanation. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modern Monte Carlo methods for efficient uncertainty quantification and propagation: A survey

Uncertainty quantification (UQ) includes the characterization, integration, and propagation of uncertainties that result from stochastic variations and a lack of knowledge or data in the natural world. Monte Carlo (MC) method is a sampling-based approach that has widely used for quantification and propagation of uncertainties. However, the standard MC method is often time-consuming if the simulation-based model is computationally intensive. This article gives an overview of modern MC methods to address the existing challenges of the standard MC in the context of UQ. Specifically, multilevel Monte Carlo (MLMC) extending the concept of control variates achieves a significant reduction of the computational cost by performing most evaluations with low accuracy and corresponding low cost, and relatively few evaluations at high accuracy and corresponding high cost. Multifidelity Monte Carlo (MFMC) accelerates the convergence of standard Monte Carlo by generalizing the control variates with different models having varying fidelities and varying computational costs. Multimodel Monte Carlo method (MMMC), having a different setting of MLMC and MFMC, aims to address the issue of UQ and propagation when data for characterizing probability distributions are limited. Multimodel inference combined with importance sampling is proposed for quantifying and efficiently propagating the uncertainties resulting from small data sets. All of these three modern MC methods achieve a significant improvement of computational efficiency for probabilistic UQ, particularly uncertainty propagation. Finally, an algorithm summary and the corresponding code implementation are provided for each of the modern MC methods. The extension and application of these methods are discussed in detail.

97 MATHEMATICS AND COMPUTING↗

RASPA3

RASPA3, a molecular simulation code for computing adsorption and diffusion in nanoporous materials and thermodynamic and transport properties of fluids. It implements force field based classical Monte Carlo/molecular dynamics in various ensembles. RASPA3 is rewritten from the ground up in C++23 with speed and code readability in mind. Transition-matrix Monte Carlo is added to compute the density of states and free energies. The Monte Carlo code for rigid molecules is based on quaternions, and the atomic positions needed in the energy evaluation are recreated from the center of mass position and quaternion orientation. The expanded ensemble methodology for fractional molecules, with a scaling parameter λ between 0 and 1, now also keeps track of analytic expressions of dU/dλ, allowing independent verification of the chemical potential using thermodynamic integration. The source code is freely available under the MIT license on GitHub.

Dubbeldam, David↗

Uncertainty Underprediction in Monte Carlo Eigenvalue Calculations

It is well-known that statistical estimates obtained from Monte Carlo criticality simulations can be adversely affected by cycle-to-cycle correlations in the fission source, which can lead to estimates of statistical uncertainties that are lower than the true uncertainty by a factor of 5 or more. However, several other more fundamental issues such as adequate source sampling over the fissionable regions and source convergence can have a significant impact on the uncertainties for the calculated eigenvalue and localized tally means, and these issues may be mistaken for effects resulting from cycle-to-cycle correlations. In worst-case scenarios, the uncertainty may be underpredicted by a factor of 40 or more. Since Monte Carlo methods are widely used in criticality safety applications and are increasingly being used for benchmarking reactor analyses, an in-depth understanding of the effects of these issues must be developed in order to support the practical use of Monte Carlo software packages. A rigorous statistical analysis of eigenvalue and localized tally results in Monte Carlo criticality calculations is presented using the SCALE/KENO-VI (continuous-energy version) and MCNP codes. The purpose of this analysis is to investigate the underprediction of uncertainty and its sensitivity to problem characteristics and calculational parameters using two of the most widely used Monte Carlo criticality codes. For the problems considered here, which are fuel rod and fuel assembly problems with reflecting boundary conditions on all four horizontal sides, we show that adequate source convergence along with proper specification of Monte Carlo parameters can reduce the magnitude of uncertainty underprediction to reasonable levels, below a factor of 2 in most cases.

Mervin, Brenden T↗

Advanced Mesh-Enabled Monte Carlo Capability for Multi-Physics Reactor Analysis

This project will accumulate high-precision fluxes throughout reactor geometry on a non-orthogonal grid of cells to support multi-physics coupling, in order to more accurately calculate parameters such as reactivity coefficients and to generate multi-group cross sections. This work will be based upon recent developments to incorporate advanced geometry and mesh capability in a modular Monte Carlo toolkit with computational science technology that is in use in related reactor simulation software development. Coupling this capability with production-scale Monte Carlo radiation transport codes can provide advanced and extensible test-beds for these developments. Continuous energy Monte Carlo methods are generally considered to be the most accurate computational tool for simulating radiation transport in complex geometries, particularly neutron transport in reactors. Nevertheless, there are several limitations for their use in reactor analysis. Most significantly, there is a trade-off between the fidelity of results in phase space, statistical accuracy, and the amount of computer time required for simulation. Consequently, to achieve an acceptable level of statistical convergence in high-fidelity results required for modern coupled multi-physics analysis, the required computer time makes Monte Carlo methods prohibitive for design iterations and detailed whole-core analysis. More subtly, the statistical uncertainty is typically not uniform throughout the domain, and the simulation quality is limited by the regions with the largest statistical uncertainty. In addition, the formulation of neutron scattering laws in continuous energy Monte Carlo methods makes it difficult to calculate adjoint neutron fluxes required to properly determine important reactivity parameters. Finally, most Monte Carlo codes available for reactor analysis have relied on orthogonal hexahedral grids for tallies that do not conform to the geometric boundaries and are thus generally not well-suited to coupling with the unstructured meshes that are used in other physics simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Monte Carlo simulation of particle acceleration at astrophysical shocks

A Monte Carlo code was developed for the simulation of particle acceleration at astrophysical shocks. The code is implemented in Turbo Pascal on a PC. It is modularized and structured in such a way that modification and maintenance are relatively painless. Monte Carlo simulations of particle acceleration at shocks follow the trajectories of individual particles as they scatter repeatedly across the shock front, gaining energy with each crossing. The particles are assumed to scatter from magnetohydrodynamic (MHD) turbulence on both sides of the shock. A scattering law is used which is related to the assumed form of the turbulence, and the particle and shock parameters. High energy cosmic ray spectra derived from Monte Carlo simulations have observed power law behavior just as the spectra derived from analytic calculations based on a diffusion equation. This high energy behavior is not sensitive to the scattering law used. In contrast with Monte Carlo calculations diffusive calculations rely on the initial injection of supra-thermal particles into the shock environment. Monte Carlo simulations are the only known way to describe the extraction of particles directly from the thermal pool. This was the triumph of the Monte Carlo approach. The question of acceleration efficiency is an important one in the shock acceleration game. The efficiency of shock waves efficient to account for the observed flux of high energy galactic cosmic rays was examined. The efficiency of the acceleration process depends on the thermal particle pick-up and hence the low energy scattering in detail. One of the goals is the self-consistent derivation of the accelerated particle spectra and the MHD turbulence spectra. Presumably the upstream turbulence, which scatters the particles so they can be accelerated, is excited by the streaming accelerated particles and the needed downstream turbulence is convected from the upstream region. The present code is to be modified to include a better description of particle scattering (pitch-angle instead of hard-sphere) and as iterative procedure for treating the self-excitation of the MHD turbulence.

Campbell, Roy K.↗