Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

The Environmental Impact of Deep Energy Retrofits in Residential Construction

Almost two thirds of the residential homes in the U.S. were constructed before the Department of Energy implemented energy conservation measures that were later formalized in the building codes. To reduce energy consumption and carbon emissions from the built environment, improvement to the existing housing stock is a prerequisite. However, improvements that lower energy consumption address carbon emissions related to heating, cooling and plug loads but not the embodied carbon of the building materials that also contribute to global carbon emissions. As the enclosure is made more efficient a larger portion of total carbon emissions is embodied carbon from the building materials. To mitigate carbon emissions, a holistic approach is required so that any improvement to the home results in a net reduction in carbon emissions. To understand the overall environmental impact of building enclosure improvements, the embodied and operational carbon emissions are calculated in this investigation and compared to the overall energy savings associated with enclosure improvements. The energy savings together with a reduction in operational carbon emissions are calculated using a novel building envelope metric. The net carbon emissions are then determined before and after the energy improvement measures. This approach allows or enables architects and builders to select designs that result in maximizing the overall reduction in energy and carbon emissions.

Aldykiewicz Jr, Antonio↗

Thermally anisotropic composites for thermal management in building environments

An improved system for thermal management is provided. The system includes thermally anisotropic composites coupled with a thermal loop to re-direct, reduce, and shape heat flows through a building envelope, having the potential to (1) significantly reduce envelope-generated heating and cooling loads and (2) provide grid services such as decreasing peak loads and shaping energy use. In one embodiment, the thermal management system includes an anisotropic composite that consists of alternating layers of thermal insulation and thermally conductive materials that are immediately adjacent to each other, including polyisocyanurate foam boards and aluminum sheets. The thermal management system also includes a thermal loop along the long edge or the entire the perimeter of the anisotropic composite, the thermal loop having dynamically controlled or floating temperature that is maintained at lower than an outdoor ambient temperature (for cooling). An interior wall structure is inwardly adjacent to the anisotropic composite.

Shrestha, Som S.↗

Thermal Performance of Spandrel Assemblies in Glazed Wall Systems: Laboratory Test Design – Challenges and Test Results

Accurate thermal performance calculation procedures for opaque spandrel areas in curtain wall and window wall systems are essential for rating systems when comparing spandrel systems. However, there is a lack of consensus in thermal modeling needed for accurately characterizing heat transfer through spandrel assemblies due to the complex arrangement of materials and structural components. Several studies indicate that conventional 2D thermal simulations may overestimate R-values by 30% compared to physical testing and 3D simulations. Detailed simulations and well-curated laboratory test data are necessary to build confidence in simulation models, which will later be used to develop correlations to improve widely used conventional 2D thermal simulations. This study aims to experimentally test heat transfer through various spandrel assemblies to validate 3D simulation models. Also, the challenges of conducting a thorough testing design along with the solutions would be documented. The team developed a design for testing spandrel assemblies, making appropriate modifications to the existing heat, air, and moisture (HAM) chamber to accommodate the testing needs. Two moveable baffles were designed and fabricated to guide airflow direction parallel to the test article surface. The data acquisition capabilities in the chamber were upgraded to add more than two hundred sensors to the climate and indoor side of the chamber. The goal is to provide a quality dataset for validating complex 3D modeling simulations, which will be used to develop improved thermal simulation techniques that more accurately represent the thermal behavior of spandrel assemblies and their integration within the building envelope. This paper will summarize the results for the boundary conditions of the testing and the temperature variation across different locations of the spandrel assemblies.

Kunwar, Niraj [ORNL] (ORCID:0000000263457652)↗

Building Science Advisor (BSA): A Tool to Assist in the Design and Education of Durable Envelopes

The moisture durability of a building envelope component can be difficult to predict. It depends on the materials used, the location in the assembly, the macro- and microclimate of the building, the air tightness of the interior environment and construction quality. Modern building codes require more insulation and tighter construction but provide little guidance about how to ensure these energy-efficient assemblies are designed and built to retain moisture durability. Furthermore, as new products are introduced to the market, builders are increasingly uncertain about the long-term durability of their building envelope designs. As building envelopes get tighter and better insulated, moisture management is key to a durable and high-performing wall assembly.

Desjarlais, Andre↗

Potential benefits and optimization of cool-coated office buildings: A case study in Chongqing, China

Increasing envelope facet albedos considerably reduces solar heat gain, thus yielding building cooling energy savings. Few studies have explored the potential benefits of utilizing cool coatings on building envelopes (“cool-coated buildings”) based on life-cycle cost analysis. A holistic approach integrating the field testing, building energy simulation, and a 20-year life-cycle-based optimization was developed to explore cool-coated building performance and the maximum net savings of optimal building envelope retrofit and design. Experimental results showed that applying cool coatings to a west wall of an office building in Chongqing, China reduced its exterior surface temperature by up to 9.3 °C in summer. Additionally, simulation results showed that in Chongqing, making the roof and walls cool could reduce annual HVAC electricity use by up to 11.9% in old buildings (with poorly insulated envelopes) and up to 5.9% in new buildings. Retrofitting old buildings with a cool roof provided the net savings per modified area with present values up to 42.8 CNY/m2; retrofitting a new building with a cool roof or cool walls was not cost-effective. Optimizing both envelope insulation and envelope albedo can achieve 5.6 times the net savings of optimizing the insulation only, and 1.6 times that of optimizing albedo only.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards Energy-Positive Buildings through a Quality-Matched Energy Flow Strategy

Current strategies for net-zero buildings favor envelopes with minimized aperture ratios and limiting of solar gains through reduced glazing transmittance and emissivity. This load-reduction approach precludes strategies that maximize on-site collection of solar energy, which could increase opportunities for net-zero electricity projects. To better leverage solar resources, a whole-building strategy is proposed, referred to as “Quality-Matched Energy Flows” (or Q-MEF): capturing, transforming, buffering, and transferring irradiance on a building’s envelope—and energy derived from it—into distributed end-uses. A mid-scale commercial building was modeled in three climates with a novel Building-Integrated, Transparent, Concentrating Photovoltaic and Thermal fenestration technology (BITCoPT), thermal storage and circulation at three temperature ranges, adsorption chillers, and auxiliary heat pumps. BITCoPT generated electricity and collected thermal energy at high efficiencies while transmitting diffuse light and mitigating excess gains and illuminance. The balance of systems satisfied cooling and heating demands. Relative to baselines with similar glazing ratios, net electricity use decreased 71% in a continental climate and 100% or more in hot-arid and subtropical-moderate climates. Total EUI decreased 35%, 83%, and 52%, and peak purchased electrical demands decreased up to 6%, 32%, and 20%, respectively (with no provisions for on-site electrical storage). Decreases in utility services costs were also noted. These results suggest that with further development of electrification the Q-MEF strategy could contribute to energy-positive behavior for projects with similar typology and climate profiles.

54 ENVIRONMENTAL SCIENCES↗

Performance analysis and comparison of data-driven models for predicting indoor temperature in multi-zone commercial buildings

Building thermal models, which characterize the properties of a building’s envelope and thermal mass, are essential for accurate indoor temperature and cooling/heating demand prediction. Because of their flexibility and ease of use, data-driven models are increasingly used. Here, this study compared and analyzed the performance of gray-box (resistance-capacitance) and black-box (recurrent neural network) models for predicting indoor air temperature in a real multi-zone commercial building. The developed resistance-capacitance model served as a benchmark model for which full sets of temporal data and building information were used as inputs. The recurrent neural network models were trained and tested assuming various available types and amounts of temporal data and known building physical information to investigate the effects of data and information availability. Feature importance analysis was conducted to select the key variables for different prediction targets under different scenarios. This research provides guidance in selecting an appropriate building thermal response modeling method based on the measured data availability, building physical information, and application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-efficient building technologies

Buildings consume one-third of the total final energy produced on the globe and are responsible for almost 40 percent of total carbon dioxide generation annually. The latest carbon dioxide burden of buildings approached 10 Gigatons in the year 2019. Energy-efficient building technologies are necessary to address the climate change induced by greenhouse gases and fulfill the growth in demand and continuously depleting energy reserves. To meet the net-zero carbon footprint goals, sustainable, renewable energy resources, efficient building technologies, and demand management strategies are needed. Achieving zero emissions will require buildings to be equipped with energy-efficient technologies while completely avoiding on-site fossil fuel consumption and being only powered by renewable energy. In this context, this chapter provides an overview of various building technologies, including envelopes, materials, equipment, appliances, and integration concepts, which will play a significant role in lowering the overall energy consumption in both existing building stock and new buildings. Specifically, the following areas are discussed in detail: emerging building envelope designs, thermal comfort and refrigeration equipment, bridging technologies for improved energy efficiency in the ongoing energy transition, hybrid renewable (photovoltaic) configurations, energy storage technologies, miscellaneous appliances, refrigerants, and renewable fuels. The influence of key design and operating characteristics on annual carbon footprint is presented.

Cheekatamarla, Praveen↗

Modeled Results of Four Residential Energy Efficiency Measure Packages for Deriving Advanced Building Construction Research Targets

The Advanced Building Construction (ABC) Initiative from the U.S. Department of Energy Building Technologies Office is working to accelerate industrialized construction innovations for decarbonizing buildings. To inform performance and cost targets for research under the ABC Initiative, this analysis used the ResStock™ tool to evaluate the energy savings, utility bill impacts, and carbon emissions impacts of four simulated upgrade packages with specific target performance levels on a large sample of residential dwelling units (approximately 550,000) representative of the U.S. housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A systematic review of building energy sufficiency towards energy and climate targets

Among the sufficiency, efficiency, and renewable frameworks for reducing energy use and energy-related carbon emissions, Building Energy Sufficiency (BES) is gaining attention from policy makers and engineers. Despite the significant role of the building sector in the success of national energy and climate plans, there is a lack of research on the drivers, technologies, and effective policy instruments required to achieve BES in the building operational phase. To fill this gap, this study presents a systematic review of the definition and paradigm of BES and concludes that BES should address both occupant demand and energy or emissions requirements simultaneously. The characteristics of occupant demand in building services are divided into four dimensions: time and space, quality and quantity, control and adjustment, and flexibility. Technical options regarding the building architecture, the envelope system, and the building energy system are reviewed. Finally, policy implications and recommendations are discussed. As a result, the multiple benefits and multidisciplinary nature of BES justify further research and accelerated policy implementation in developed and developing countries.

54 ENVIRONMENTAL SCIENCES↗

Grid-interactive Efficient Buildings Projects Summary

Through its grid-interactive efficient building (GEB) research, DOE’s Building Technologies Office seeks to build on existing energy-efficiency efforts to optimize the interplay among energy efficiency, demand response, behind-the-meter generation and energy storage to increase the flexibility of demand-side management. BTO envisions a future where buildings dynamically operate as part of a low cost, reliable electricity grid while meeting the needs and expectations of building occupants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance assessment of active insulation systems in residential buildings for energy savings and peak demand reduction

Active insulation systems (AISs) in buildings are envelopes that integrate thermal insulation, thermal energy storage, and controls. Although different designs for AISs have been proposed in the literature, a comprehensive analysis of feasible AISs is lacking. This paper discusses the energy performance, peak demand reduction potential, and performance characteristics of an AIS that uses a concrete wall as thermal mass sandwiched between two solid-state thermal switches (STSs). These STSs change their thermal conductivity using an on/off metal switch to create or break a thermal bridge across the STS. This paper first describes the experimental setup, used to determine the ratio of thermal resistance during R-high (low thermal conductivity) and R-low (high thermal conductivity) states of the STSs. This ratio was then used in whole-building energy simulations to evaluate the performance of AIS walls across different climate zones with/without a freeze timer of 60 min. The timer was added to reduce the number of switches of STSs from one state to another, and hence the energy needed for these switches. Analysis of the switching frequency and interval of STSs, thermal conductivity of walls, impact of wall orientation, and heat transfer through the wall from the use of AIS at different climate zones/locations were performed. The simulation results show that the AIS can achieve energy savings ranging from ~980 to 2,290 kWh in a single-family home with a floor area of ~220 m 2 compared with an IECC 2018 baseline. We found the energy savings was higher in dry climate zones which represent 17% of residential buildings in the United States, compared to humid or marine climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving air leakage prediction of buildings using the fan pressurization method with the Weighted Line of Organic Correlation

In many countries, the fan pressurization method is the most frequently chosen approach for measuring the air leakage of houses. The measurements are usually performed at pressures that far exceed pressures to which buildings are exposed to under normal conditions. A fit of these tests to the power-law formulation allows an extrapolation to data points outside the measured pressure range. With the Ordinary Least Square (OLS) fitting method, the pressure exponent and flow coefficient can be determined. However, the measurement results are highly sensitive to uncertainties induced by external factors like changing wind conditions during the tests, which is neglected by OLS. This may lead to errors in the prediction of flows at lower pressures. The Weighted Line of Organic Correlation (WLOC) is an alternative approach and takes measurement uncertainty into account. In this paper, a statistical analysis of an extensive data set of pressurization measurements has been performed. Both regression techniques have been compared for almost 7500 fan pressurization measurements of six houses in 109 different house leak configurations. The variability in predicting pressure exponent and flow coefficient for both WLOC and OLS regression was analyzed using probability density functions. It was found that the Weighted Line of Organic Correlation significantly decreases the uncertainty in predicting pressure exponent, flow coefficient, and other low-pressure air leakage metrics compared to the Ordinary Least Square fitting. Here, the authors highly recommend the implementation of WLOC in current measurement standards and test equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($\$$434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microencapsulation of bio-based phase change materials with silica coated inorganic shell for thermal energy storage

This study investigates the use of cenospheres to encapsulate a low-cost, bio-based phase change material (PCM) derived from refined edible vegetable oil. Chemical etching was applied on the cenospheres to create holes through which melted PCM was loaded to produce a PCM microcapsule. Subsequently, a silica-based coating was applied to seal the perforations and prevent leakage of PCM from the microcapsule. Microstructural, chemical compatibility, thermal, and leakage properties of the produced silica coated PCM microcapsule (SCPCM) were assessed. No leakage was found for this new microcapsule, and higher thermal stability and conductivity were noted. Thermal decomposition of the PCM in SCPCM was delayed by about 16 degrees C attributable to the silica coating. Additionally, an enhanced compressive strength performance was achieved at 10 vol% of sand replacement with SCPCM. 20-30 vol% replacement of sand with cenosphere microcapsules seems to be the optimal range for reasonable compressive strength. The workability of the mortar incorporated with SCPCM decreased when the replacement level increased to more than 30 vol% due to the hydrophilic nature of the silica deposit. This study has demonstrated the potential of cenospheres as inorganic shell for PCMs and the potential for incorporation of SCPCM into construction materials for thermal energy storage (TES).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantification of air leakage paths: a comparison of airflow and acoustic measurements

Today, the fan pressurization method is the most frequently used method to evaluate a building's airtightness. However, the localization and quantification of leaks remain difficult. In this paper, an acoustic method is introduced to estimate the leakage size of single leaks. Acoustic and airflow measurements were conducted and compared in laboratory tests within the same boundary conditions. This work aims to investigate if various leak sizes can be predicted using acoustic measurement methods. The test apparatus consists of two chambers, separated by a test wall. This wall represents a single characteristic air leakage path. Various types of wall structures with different slit geometries, wall thicknesses, and insulation materials were investigated. The acoustic measurements were performed with a sound source placed in one chamber and ultrasonic microphones located in both chambers. These results were compared to measured airflows through the test wall to provide estimates of uncertainty in the acoustic approach, which indicate a linear trend. Finally, these laboratory measurements were compared to the same measurements at a real office building. Finally, although the acoustic measurement uncertainty is still significant (greater than +/- 50%), the acoustic method has the potential to give an order of magnitude of single leak sizes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BESTEST-GSR (Building Energy Simulation Test - Generation Simulation and Reporting) 2023 [SWR 18-23]

Building Energy Simulation Test (BESTEST) is an NREL-developed method to validate the qualitative performance of different whole building simulations engines relative to each other. https://www.nrel.gov/docs/legosti/old/6231.pdf The purpose of this repository is to generate BESTEST test case models, run simulations, and populate data for ASHRAE Standard 140 reporting spreadsheets for EnergyPlus® based whole building simulation tools. It was originally setup for 2014 version of Standard 140. In May of 2022 it was updated to the 2020 version of Standard 140. This update included updates and additions to existing test suites, the bulk of which was in Section 5.2 (Building Thermal Envelope and Fabric Load Tests). We did not add Section 5.5 Airside HVAC Equipment Performance, but we hope to add that later in 2022. At some point we also hope to add Section 5.2.4 ground modeling, which is currently excluded. Supported Tools The default IDF generation is based on the OpenStudio® CLI, but the workflow supports a 'Bring your own IDF' use case. Additionally, for non-EnergyPlus® based tools the post processing scripts can be used if simulation results are provided as a CSV file.The scripts on this repository should work on Mac, Windows, and Linux. Dependencies Install OpenStudio® 3.4.0 make sure command line can recognize the 'openstudio' command This includes EnergyPlus® 22.1 Install Ruby on your system if it isn't already setup. 2.7 is used for development but other versions may work Since OpenStudio has its own embedded Ruby, which is used for running measures, you don't necessarily have to use a version of Ruby supported by OpenStudio. Install RubyXL Ruby gem This is used to modify Microsoft Excel spreadsheets Install Parallel Ruby gem This allows the CLI to run simulations in parallel

Goldwasser, David↗