Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Blackbody”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

First Flight of ARCADE CMB Instrument

ARCADE (Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission) is a balloon-borne cryogenic instrument to measure the spectrum of the cosmic microwave background radiation at centimeter wavelengths. ARCADE compares the sky to an on-board external blackbody target to measure small differences between the sky spectrum and a known blackbody. The instrument uses a novel open-aperture cryogenic design to minimizes sources of systematic error. In particular, there are no windows between the cold (2.7 K) optics and the atmosphere during observations. We discuss the cryogenic performance of ARCADE during its first flight in November 2001.

Kogut, A.↗

Dip Spectroscopy of the Low Mass X-Ray Binary XB 1254-690

We observed the low mass X-ray binary XB 1254-690 with the Rossi X-ray Timing Explorer in 2001 May and December. During the first observation strong dipping on the 3.9-hr orbital period and a high degree of variability were observed, along with "shoulders" approx. 15% deep during extended intervals on each side of the main dips. The first observation also included pronounced flaring activity. The non-dip spectrum obtained using the PCA instrument was well-described by a two-component model consisting of a blackbody with kT = 1.30 +/- 0.10 keV plus a cut-off power law representation of Comptonized emission with power law photon index 1.10 +/- 0.46 and a cut-off energy of 5.9(sup +3.0, sub -1.4) keV. The intensity decrease in the shoulders of dipping is energy-independent, consistent with electron scattering in the outer ionized regions of the absorber. In deep dipping the depth of dipping reached 100%, in the energy band below 5 keV, indicating that all emitting regions were covered by absorber. Intensity-selected dip spectra were well-fit by a model in which the point-like blackbody is rapidly covered, while the extended Comptonized emission is progressively overlapped by the absorber, with the, covering fraction rising to 95% in the deepest portion of the dip. The intensity of this component in the dip spectra could be modeled by a combination of electron scattering and photoelectric absorption. Dipping did not occur during the 2001 December observation, but remarkably, both bursting and flaring were observed contemporaneously.

Smale, Alan P.↗

Broadband IR Measurements for Modis Validation

The primary objective of this research was the development and deployment of autonomous shipboard systems for infrared measurement of ocean surface skin temperature (SST). The focus was on demonstrating long-term, all-weather capability and supplying calibrated skin SST to the MODIS Ocean Science Team (MOCEAN). A secondary objective was to investigate and account for environmental factors that affect in situ measurements of SST for validation of satellite products. We developed and extensively deployed the Calibrated, InfraRed, In situ Measurement System, or CIRIMS, for at-sea validation of satellite-derived SST. The design goals included autonomous operation at sea for up to 6 months and an accuracy of +/- 0.1 C. We used commercially available infrared pyrometers and a precision blackbody housed in a temperature-controlled enclosure. The sensors are calibrated at regular interval using a cylindro-cone target immersed in a temperature-controlled water bath, which allows the calibration points to follow the ocean surface temperature. An upward-looking pyrometer measures sky radiance in order to correct for the non-unity emissivity of water, which can introduce an error of up to 0.5 C. One of the most challenging aspects of the design was protection against the marine environment. A wide range of design strategies to provide accurate, all-weather measurements were investigated. The CIRIMS uses an infrared transparent window to completely protect the sensor and calibration blackbody from the marine environment. In order to evaluate the performance of this approach, the design incorporates the ability to make measurements with and without the window in the optical path.

Jessup, Andrew T.↗

CoSSIR: A New Instrument for Exploring the Utility of Submillimeter-wave Radiometry for Earth Observation

The Conical Scanning Submillimeter-wave Imaging Radiometer (CoSSIR) has been developed to study the application of submillimeter-wave radiometry for remote sensing of cirrus clouds and humidity sounding. Measurements of the global distribution of ice cloud mass and particle size are important for understanding the Earth s energy budget and for evaluating global climate models. The spatial variability and the wide variety of cloud particle shapes and sizes make ice clouds particularly difficult to measure. Ice clouds are essentially undetectable at microwave frequencies due to the low dielectric of ice and small size of the particles relative to wavelength. However, submillimeter wavelengths demonstrate significant response to the presence of ice clouds thus this frequency regime is applicable to measuring ice clouds. Another potentially viable application for submillimeter-wave radiometry is humidity and temperature sounding. The principle of sounding at submillimeter wavelengths is similar to that at microwavelengths. Submillimeter-wave radiometry has the advantage of achieving finer spatial resolution using a smaller antenna aperture which is an important consideration for spaceborne observatories. Submillimeter-wave radiometry also offers the potential of sounding over land and as a surrogate measurement for precipitation. CoSSIR is a new instrument to explore these applications. The CoSSIR is designed to fly aboard the ER-2 aircraft and its modest size (approximately 100 kg) permits it to be configured for other aircraft. A dual-axes gimbals mechanism provides conical, across-track, and along-track scanning capability. In its present configuration CoSSIR has fifteen channels between 183 GHz and 640 GHz. Three channels are centered about the 183 GHz water vapor absorption line, four channels are centered about the 380 GHz water vapor absorption line, and three dual-polarized channels are centered about the 487 GHz oxygen absorption line. Two channels are located in atmospheric windows at 220 GHz and 640 GHz. All channels are single-linear polarized with the exception of those near 487 GHz. Calibration is achieved by periodically observing two blackbody radiators; one blackbody is heated to approximately 325 K and the other is approximately 250 K during flight. Details of the instrument design as well as measurements from the Cirrus Regional Study of Tropical Anvils and Cirrus Layers - Florida Area Cirrus Experiment will be presented.

Racette, P. E.↗

Discovery of a Three-Layered Atmospheric Structure in Accretion Disks around Stellar-Mass Black Holes

We have carried out systematic modeling of the X-ray spectra of the Galactic superluminal jet sources GRS 1915+105 and GRO J1655-40, using our newly developed spectral fitting methods. Our results reveal, for the first time, a three-layered structure of the atmosphere in the inner region of the accretion disks. Above the conanonly known, cold and optically thick disk of a blackbody temperature 0.2-0.5 keV, there is a layer of warm gas with a temperature of 1.0-1.5 keV and an optical depth of around 10. Compton scattering of the underlying disk blackbody photons produces the soft X-ray component we comonly observe. Under certain conditions, there is also a much hotter, optically thin corona above the warm layer, characterized by a temperature of 100 keV or higher and an optical depth of unity or less. The corona produces the hard X-ray component typically seen in these sources. We emphasize that the existence of the warm layer seem to be independent of the presence of the hot corona and, therefore, it is not due to irradiation of the disk by hard X-rays from the corona. Our results suggest a striking structural similarity between the accretion disks and the solar atmosphere, which may provide a new stimulus to study the common underlying physical processes operating in these vastly different systems. We also report the first unambiguous detection of an emission line around 6.4 keV in GRO J1655-40, which may allow further constraining of the accretion disk structure. We acknowledge NASA GSFC and MFC for partial financial support. (copyright) 1999: American Astronomical Society. All rights reverved.

Zhang, S. N.↗

EPIC Study of Two Enigmatic Sources: The Mouse and SNR 359.1-0.5

The objective of the original proposal was to observe the Mouse pulsar wind nebula (associated with PSR J1744-2958) and the nearby supernova remnant G359.1-0.5, where the pulsar was probably born, with the XMM-Newton observatory to study the properties of these objects. SNR G359.1-0.5 was accepted as a Category C target and has not been observed. The Mouse was observed on April 27,2003 for 52 ks. The image analysis has shown that the Mouse is extended in the East-West direction, possibly along the direction of the pulsar's proper motion. The spectrum of this pulsar wind nebula can be described as an absorbed power law with the photon index GAMMA = 1.9 plus or minus 0.1, effective hydrogen column density n(sub H) = (2.6 plus or minus 0.1) x 10(exp 22) per square centimeter, and flux F = 1.8 x 10(exp -11) erg per square centimeter per second in the 1-10 keV energy range. Based on the n(sub H) value, the distance to the source is about 5 kpc, which results in the luminosity 3.7 x 10(exp 34) erg per second. We conclude that PSR J1744-2958 and the Mouse are not physically associated with G359.1-0.5, which lies at a larger distance. In addition to the Mouse, we also detected two Low-Mass X-ray Binaries, SLX 1744-299 and 1744-300, in the EPIC MOS and PN fields of view. The latter of these objects showed a Type I X-ray burst during our observation, with a rise time of 5 s and decay time of 60 s. A very strong pileup during the burst made the analysis of the burst properties unreliable. The spectral analysis of the persistent radiation from SLX 1744-299 and 1744-300 yields the hydrogen column densities of 3.2 plus or minus 0.1 and (3.6 plus or minus 0.2) x 10(exp 22) per square centimeter, respectively, which suggests that the sources are close to the Galactic center (d = 8-9 kpc). The spectra can be reasonably well fitted with a blackbody plus thin disk model, with the blackbody temperatures of 1.7 plus or minus 0.2 and 1.8 plus or minus 0.2 keV, respectively.

Pavlov, George↗

Discovery of Soft Spectral Component and Transient 22.7s Quasi Periodic Oscillations of SAX J2103.5+4545

XMM-Newton observed SAX J2103.5+4545 on January 6, 2003, while RXTE was monitoring the source. Using RXTE-PCA dataset between December 3, 2002 and January 29, 2003, the spin period and average spin-up rate during the XMM-Newton observations were found to be 354.7940+/-0.0008 s and (7.4 +/- 0.9) x 10(exp -13) Hz/s respectively. In the power spectrum of the 0.9-11 keV EPIC-PN lightcurve, we found quasi periodic oscillations around 0.044 Hz (22.7 s) with an rms fractional amplitude approx. 6.6 %. We interpreted this QPO feature as the Keplerian motion of inhomogeneities through the inner disk. In the X-ray spectrum, in addition to the power law component with high energy cutoff and approx. 6.4 keV fluorescent iron emission line, we discovered a soft component consistent with a blackbody emission with kT approx. 1.9 keV. The pulse phase spectroscopy of the source revealed that the blackbody flux peaked at the peak of the pulse with an emission radius approx. 0.3 km, suggesting the polar cap on the neutron star approx. 6.42 keV was shown to peak at the off-pulse phase, supporting the idea that this feature arises from fluorescent emission of the circumstellar material around the neutron star rather than the hot region in the vicinity of the neutron star polar cap.

Inam, S. C.↗

XMM TOO Observation

The primary research goal of this project is to perform follow-up observations of a recurrent ultraluminous supersoft X-ray source (SSS) in Ml0l. The source was first discovered by ROSAT and was confirmed as a SSS with a blackbody temperature of about l00eV by Chandra. During 2000 March, Chandra detected it at Lx=4e39 erg per second, and then in 2000 October, its luminosity dropped to around le39 erg per second. During 2004, Chandra is conducting a monitoring program for Ml0l. The SSS was near the detection limit during January, March, and May; the X-ray spectra were harder with a power-law shape, and the X-ray luminosity was about 3e37 erg/second, a factor of greater than 200 fainter than that in the previous high state. The source was found to be in outburst again during the July 5 observation, with an X-ray luminosity of about 7e39 erg/second. Data taken on July 6,7, and 8 show that the source was in a strong outburst with a peak bolometric luminosity of about 7e39 erg/second. In general, the X-ray spectra are best described with an absorbed blackbody model with temperatures of approximately 50-100eV. In addition, we found absorption edges at 0.33, 0.57, 0.66, and 0.88 keV in two of the high state spectra. These features may signal the presence of highly ionized gas in the vicinity of the accretor (e.g., warm absorber). In order to study an ultraluminous SSS in outburst in detail, we proposed a TOO XMM observation to observe the source. The observation was taken on July 23 and the source was fainter with a luminosity of 6e38 ergs, and a harder X-ray spectrum with a power-law tail seen up to 7 keV. This clearly indicates that the source was in the decline stage with spectral change. In addition to the XMM observation, we also arranged radio observation and a simultaneous CFHT observation. The X-ray results were published in ATel and ApJL. There were several more Chandra observations taken after 2004 July. The source was in a low luminosity state but it underwent another X-ray outburst in 2004 December. We are arranging more follow-up observations for this intriguing source.

Kong, Albert↗

How to Distinguish Neutron Star and Black Hole X-ray Binaries? Spectral Index and Quasi-Periodic Oscillation Frequency Correlation

Recent studies have revealed strong correlations between 1-10 Hz frequencies of quasiperiodic oscillations (QPOs) and the spectral power law index of several Black Hole (BH) candidate sources when seen in the low/hard state, the steep power-law (soft) state, and in transition between these states. In the soft state these index-QPO frequency correlations show a saturation of the photon index GAMMA approximately equal to 2.7 at high values of the low frequency nu(sub L). This saturation effect was previously identified as a black hole signature. In this paper we argue that this saturation does not occur, at least for one neutron star (NS) source 4U 1728-34, for which the index GAMMA monotonically increases with nu(sub L) to the values of 6 and higher. We base this conclusion on our analysis of approximately 1.5 Msec of RXTE archival data for 4U 1728-34. We reveal the spectral evolution of the Comptonized blackbody spectra when the source transitions from the hard to soft states. The hard state spectrum is a typical thermal Comptonization spectrum of the soft photons which originate in the disk and the NS outer photospheric layers. The hard state photon index is GAMMA approximately 2. The soft state spectrum consists of two blackbody components which are only slightly Comptonized. Thus we can claim (as expected from theory) that in NS sources thermal equilibrium is established for the soft state. To the contrary in BH sources, the equilibrium is never established due to the presence of the BH horizon. The emergent BH spectrum, even in the high/soft state, has a power law component. We also identify the low QPO frequency nu(sub L) as a fundamental frequency of the quasi-spherical component of the transition layer (presumably related to the corona and the NS and disk magnetic closed field lines). The lower frequency nu(sub SL) is identified as the frequency of oscillations of a quasi-cylindrical configuration of the TL (presumably related to the NS and disk magnetic open field lines). We also show that the presence of Fe K(sub alpha), emission-line strengths, QPOs, and the link between them does not depend on radio flux in 4U 1728-34.

Titarchuk, Lev↗

High Resolution Spectroscopy And Timing Of The Isolated Neutron Star RBS 1774

The 2004 May 31 XMM-Newton observation was reprocessed using SASv6.0.0 and times of high background were filtered out. The net exposure time remaining was 23 ks. The source was clearly detected in MOS1, MOS2 and PN chips. We performed both timing and spectroscopic analysis on the data. We performed a spectral analysis by fitting data from the three EPIC detectors simultaneously, finding that the broadband spectrum can be represented by a single absorbed blackbody, with kT = 0.10 keV. The fitting revealed the presence of an absorption feature at 0:7 keV, but the data did have enough resolution to allow us to discriminate between an absorption line and an edge. We also tested magnetized models of Pavlov et a1 and Zavlin et al, but found that fits with these models were considerably worse than with a blackbody. For the timing analysis, we extracted the counts within a 3000 radius aperture in both PN and MOS 1 and MOS2 but with the aperture truncated by a chord where it approached the edge of the CCD window in each case: this maximized the counts while avoiding any edge effects. We analyzed PN, MOSl and MOS2 data both individually and combined using the Maximum Likelihood Periodogram technique of Zane et al. (2002) and Cropper et al. (2004). Periods from 10000 s to 30 ms were searched, ensuring that in each case the period grid was 2.5 times better sampled than the Nyquist frequency. The search revealed a significant period at 9.437s. Taken overall, we found the characteristics of RBS 1774 to be remarkably similar to those of another X-ray faint isolated neutron stars. These results were written up for the Astrophysical Journal, and the paper has recently been accepted for publication.

Mushotzky, Richard↗

The Observed Galactic Annihilation Line: Possible Signature of Accreting Small Mass Black Holes in the Galactic Center

Various balloon and satellite observatories have revealed what appears to be an extended source of 0.511 MeV annihilation radiation with flux of approx. 10(exp -3) photons/sq cm/s centered on the Galactic Center. Positrons from radioactive products of stellar explosions can account for a significant fraction of the emission. We discuss an additional source for this emission: namely e(+)e(-) pairs produced when X-rays generated from the approx. 2.6 x 10(exp 6) solar mass Galactic Center Black Hole interact with approx. 10 MeV temperature blackbody emission from 10(exp 17) g black holes within 10(exp 14-l5) cm of the center. The number of such Small Mass Black Holes (SMMBHs) can account for the production of the 10(exp 42) e(+)/s that produces the observed annihilation in the inner Galaxy when transport effects are taken into account. We consider the possibility for confirming the presence of these SMMBHs in the Galactic Center region with future generations of gamma-ray instruments if a blackbody like emission of approx. 10 MeV temperature would be detected by them. Small Mass Black Hole can be a potential candidate for dark (invisible) matter hal

Titarchuk, Lev↗

Experimental and Numerical Characterization of Transient Insertion of Heat Flux Gages in a Cylindrical Black Body Cavity at 1100 C

Initial transient thermal models have been developed to simulate a heat flux gage calibration process capable of generating high heat flux levels of interest to reciprocating and gas turbine engine industries as well as the aerospace industry. These transient models are based on existing, experimentally validated, steady state models of the cylindrical blackbody calibration system. The steady state models were modified to include insertion of a heat flux gage into the hot zone of the calibration system and time varying electrical current passing through the resistance heated blackbody. Heat fluxes computed using the initial transient models were compared to experimental measurements. The calculated and measured transient heat fluxes were within 5% indicating that the major physical phenomena in the transient calibration had been captured by the models. The predicted and measured transient heat fluxes were also compared at two different gage insertion depths. These results indicated that there is an optimum insertion position which maximizes heat flux and minimizes cavity disturbance.

Abdelmessih, A. N.↗

Results and Lessons from MODIS Thermal Emissive Bands Calibration: Pre-launch to On-orbit

MODIS is a major instrument for the NASA EOS Terra (launched in December 1999) and Aqua (launched in May 2002) missions. It was designed and built to enhance and extend its heritage sensors' measurements and data records with applications covering a wide range of studies of the Earth's land, oceans, and atmosphere. Its 16 thermal emissive bands (TEB), each with 10 detectors, are located on the two cold focal plane assemblies (FPAs) controlled by a passive radiative cooler. Because of instrument design complexity and stringent calibration requirements, extensive calibration and characterization activities were conducted pre-launch by the sensor vendor for both Terra and Aqua MODIS. For TEB, these activities include characterization of detectors' noise and non-linearity and evaluation of their radiometric performance in thermal vacuum at difference instrument temperatures and FPA temperatures. In addition TEB system level response versus scan-angle (RVS) and relative spectral response (RSR) were characterized. MODIS TEB radiometric calibration transfer from pre-launch to on-orbit was performed using spectral bands' responses to the instrument on-board blackbody and a laboratory blackbody calibration source (BCS) traceable to NIST standards. This paper provides a summary of MODIS TEB pre-launch and on-orbit calibration and characterization activities, challenges, data analysis results, and lessons learned with focus on sensors' radiometric performance. A comparison between Terra and Aqua MODIS TEB performance is also presented. A similar summary for the reflective solar bands (RSB) is reported in a separate paper in these proceedings.

Xiong, X.↗

Detector Noise Characterization and Performance of MODIS Thermal Emissive Bands

MODIS has 16 thermal emissive bands, a total of 160 individual detectors (10 for each spectral bands), located on the two cold focal plane assemblies (CFPA). MODIS TEB detectors were fully characterized pre-launch in a thermal vacuum (TV) environment using a NIST traceable blackbody calibration source (BCS) with temperatures ranging from 170 to 340K. On-orbit the TEB detectors are calibrated using an on-board blackbody (BB) on a scan-by-scan basis. For nominal on-orbit operation, the on-board BB temperature is typically controlled at 285K for Aqua MODIS and 290K for Terra MODIS. For the MODIS TEB calibration, each detector's noise equivalent temperature difference (NEdT) is often used to assess its performance and this parameter is a major contributor to the calibration uncertainty. Because of its impact on sensor calibration and data product quality, each MODIS TEB detector's NEdT is monitored on a daily basis at a fixed BB temperature and completely characterized on a regular basis at a number of BB temperatures. In this paper, we describe MODIS on-orbit TEB NEdT characterization activities, approaches, and results. We compare both pre-launch and on-orbit performance with sensor design specification and examine detector noise characterization impact on the calibration uncertainty. To date, 135 TEB detectors (out of a total of 160 detectors) in Terra MODIS (launched in December 1999) and 158 in Aqua MODIS (launched in May 2002) continue to perform with their NEdT below (or better than) their design specifications. A complete summary of all TEB noisy detectors, identified both pre-launch and on-orbit, is provided.

Xiong, X.↗

The 2006-2007 Active Phase Of Anomalous X-Ray Pulsar 4U 0142+61: Radiative and Timing Changes, Bursts, and Burst Spectral Features

After at least 6 years of quiescence, Anomalous X-ray Pulsar (AXP) 4U 0142+61 entered an active phase in 2006 March that lasted several months and included six X-ray bursts as well as many changes in the persistent X-ray emission. The bursts, the first seen from this AXP in >11 years of Rossi X-ray Timing Explorer monitoring, all occurred in the interval between 2006 April 6 and 2007 February 7. The burst durations ranged from 8-3x10(exp 3)s. The first five burst spectra are well modeled by blackbodies, with temperatures kT approx. 2 - 6 keV. However, the sixth burst had a complicated spectrum that is well characterized by a blackbody plus three emission features whose amplitude varied throughout the burst. The most prominent feature was at 14.0 keV. Upon entry into the active phase the pulsar showed a significant change in pulse morphology and a likely timing glitch. The glitch had a total frequency jump of (1.9+/-0.4)x10(exp -7) Hz, which recovered with a decay time of 17+/-2 days by more than the initial jump, implying a net spin-down of the pulsar. We discuss these events in the context of the magnetar model.

Gavril, Fotis P.↗

Ultra-high Temperature Emittance Measurements for Space and Missile Applications

Advanced modeling and design efforts for many aerospace components require high temperature emittance data. Applications requiring emittance data include propulsion systems, radiators, aeroshells, heatshields/thermal protection systems, and leading edge surfaces. The objective of this work is to provide emittance data at ultra-high temperatures. MSFC has a new instrument for the measurement of emittance at ultra-high temperatures, the Ultra-High Temperature Emissometer System (Ultra-HITEMS). AZ Technology Inc. developed the instrument, designed to provide emittance measurements over the temperature range 700-3500K. The Ultra-HITEMS instrument measures the emittance of samples, heated by lasers, in vacuum, using a blackbody source and a Fourier Transform Spectrometer. Detectors in a Nicolet 6700 FT-IR spectrometer measure emittance over the spectral range of 0.4-25 microns. Emitted energy from the specimen and output from a Mikron M390S blackbody source at the same temperature with matched collection geometry are measured. Integrating emittance over the spectral range yields the total emittance. The ratio provides a direct measure of total hemispherical emittance. Samples are heated using lasers. Optical pyrometry provides temperature data. Optical filters prevent interference from the heating lasers. Data for Inconel 718 show excellent agreement with results from literature and ASTM 835. Measurements taken from levitated spherical specimens provide total hemispherical emittance data; measurements taken from flat specimens mounted in the chamber provide near-normal emittance data. Data from selected characterization studies will be presented. The Ultra-HITEMS technique could advance space and missile technologies by advancing the knowledge base and the technology readiness level for ultra-high temperature materials.

Rogers, Jan↗

Discovery of Photon Index Saturation in the Black Hole Binary GRS 1915+105

We present a study of the correlations between spectral, timing properties and mass accretion rate observed in X-rays from the Galactic Black Hole (BH) binary GRS 1915+105 during the transition between hard and soft states. We analyze all transition episodes from this source observed with Rossi X-ray Timing Explorer (RXTE), coordinated with Ryle Radio Telescope (RT) observations. We show that broad-band energy spectra of GRS 1915+105 during all these spectral states can be adequately presented by two Bulk Motion Comptonization (BMC) components: a hard component (BMC1, photon index Gamma(sub 1) = 1.7 -- 3.0) with turnover at high energies and soft thermal component (BMC2, Gamma(sub 2) = 2.7 -- 4.2) with characteristic color temperature < or = 1 keV, and the red-skewed iron line (LAOR) component. We also present observable correlations between the index and the normalization of the disk "seed" component. The use of "seed" disk normalization, which is presumably proportional to mass accretion rate in the disk, is crucial to establish the index saturation effect during the transition to the soft state. We discovered the photon index saturation of the soft and hard spectral components at values of < or approximately equal 4.2 and 3 respectively. We present a physical model which explains the index-seed photon normalization correlations. We argue that the index saturation effect of the hard component (BMC1) is due to the soft photon Comptonization in the converging inflow close to 1311 and that of soft component is due to matter accumulation in the transition layer when mass accretion rate increases. Furthermore we demonstrate a strong correlation between equivalent width of the iron line and radio flux in GRS 1915+105. In addition to our spectral model components we also find a strong feature of "blackbody-like" bump which color temperature is about 4.5 keV in eight observations of the intermediate and soft states. We discuss a possible origin of this "blackbody-like" emission.

Titarchuk, Lev↗

Comparison of VIIRS Prelaunch RVS Among Independent Studies

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor carried on the NPOESS (National Polar-orbiting Operational Environmental Satellite System), upgraded and developed recently from heritage instruments including AVHRR, OLS, MODIS, and SeaWiFS. It has on-board calibration components including a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view (SV) port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and will be used on-orbit to characterize the response for the all scan angles relative to the calibrator scan angle (SD for RSB and blackbody for TEB). Since the RVS is vitally important to the quality of calibrated radiance products, several independent studies were performed and their results were compared and validated. This document provides RVS results from three groups: the NPP Instrument Calibration Support Team (NICST), Raytheon, and the Aerospace Corporation. A comparison of the RVS results obtained using a 2nd order polynomial fit to measurement data is conducted for each band, detector, and half angle mirror (HAM) side. The associated RVS fitting residuals are examined and compared with the relative differences in RVS found between independent studies. Results show that the agreement is within 0.1% and comparable with fitting residuals for all bands except for RSB band M9, where a difference of 0.2% results from the application of the atmospheric water vapor correction for laboratory conditions during the test by Raytheon. NICST has slightly larger RSB RVS uncertainties but still well within the 0.3% total uncertainty allowed for the RVS characterization defined in the Performance Verification Plan.

Wu, Aisheng↗