Scheduling and flexible control of bandwidth and in-transit services for end-to-end application workflows
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not Available
Future silicon trackers will be operated in an intense radiation environment and require large volumes of data to be transmitted off detector. In addition, the optical modules must be of low mass in order to limit multiple scattering and nuclear interactions that would degrade the overall performance of the detector. Here, we present a miniature optical engine that satisfies these constraints. The optical engine consists of an ASIC driving a VCSEL (Vertical Cavity Surface Emitting Laser) array in an optical package. Two ASICs are designed to operate a 12-channel VCSEL array at 1.28 or 5.12 Gb/s per channel, which yields a total data rate of up to 60 Gb/s. The core transistors are fabricated in a 65 nm CMOS process which enhance the radiation-hardness. Each channel contains equalizer (CTLE) and clock-data recovery circuits (CDR) so that the ASIC can restore the highly distorted electrical signal after propagating through several meters of cables of small diameter. The equalizer, CDR, and VCSEL driver are configured via a digital I 2 C chip interface with triple redundant memory to mitigate single event upset (SEU) effects. The bias and modulation currents are controlled by a digital-to-analog converter (DAC). We present the design of the circuit together with the results of the simulations and preliminary measurements.
Not Available
Rayleigh–Taylor instability experiments are performed using both immiscible and miscible incompressible liquid combinations having a relatively large Atwood number of $A\equiv ({\it\rho}_{2}-{\it\rho}_{1})/({\it\rho}_{2}+{\it\rho}_{1})=0.48$ . The liquid-filled tank is attached to a test sled that is accelerated downwards along a vertical rail system using a system of weights and pulleys producing approximately $1g$ net acceleration. The tank is backlit and images are digitally recorded using a high-speed video camera. The experiments are either initiated with forced initial perturbations or are left unforced. The forced experiments have an initial perturbation imposed by vertically oscillating the liquid-filled tank to produce Faraday waves at the interface. The unforced experiments rely on random interfacial fluctuations, resulting from background noise, to seed the instability. The main focus of this study is to determine the effects of forced initial perturbations and the effects of miscibility on the growth parameter, ${\it\alpha}$ . Measurements of the mixing-layer width, $h$ , are acquired, from which ${\it\alpha}$ is determined. It is found that initial perturbations of the form used in this study do not affect measured ${\it\alpha}$ values. However, miscibility is observed to strongly affect ${\it\alpha}$ , resulting in a factor of two reduction in its value, a finding not previously observed in past experiments. In addition, all measured ${\it\alpha}$ values are found to be smaller than those obtained in previous experimental studies.
Explore the source record for details and available documents.
First results from IRENI, a new beamline at the Synchrotron Radiation Center, demonstrate that synchrotron chemical imaging, which combines the characteristics of bright, stable, broadband synchrotron source with a multi-element detector, produces diffraction-limited images at all wavelengths simultaneously. A single cell of Micrasterias maintained in a flow cell has been measured, and results show high quality spectra and images demonstrating diffraction limited, and therefore wavelength-dependent, spatial resolution.
Bright narrow band emission observed in optically thin plasmas of high-Z elements in the extreme ultraviolet spectral region follows a quasi-Moseley's law. The peak wavelength can be expressed as λ=(21.86±12.09)×R{sub ∞}{sup −1}×(Z−(23.23±2.87)){sup −(1.52±0.12)}, where R{sub ∞} is the Rydberg constant. The wavelength varies from 13.5 nm to 4.0 nm as the atomic number, Z, increases from Z = 50 to Z = 83. The range of emission wavelengths available from hot optically thin plasmas permits the development of bright laboratory-scale sources for applications including x-ray microscopy and x-ray absorption fine structure determination.
In order to improve both the density and particularly the temporal resolution beyond previous dispersion interferometers (DIs), a heterodyne technique based on an acousto-optic (AO) cell has been added to the DI. A 40 MHz drive frequency for the AO cell allows density fluctuation measurements into the MHz range. A CO 2 laser-based heterodyne DI (HDI) installed on DIII-D has demonstrated that the HDI is capable of tracking the density evolution throughout DIII-D discharges, including disruption events and other rapid transient phenomena. The data also show good agreement with independent density measurements obtained with the existing DIII-D two-color interferometer. The HDI line-integrated density resolution sampled over a 1 s interval is ~9 × 10 17 m -2 . Density fluctuations induced by MHD instabilities are also successfully measured by the HDI.
Explore the source record for details and available documents.
In inertial confinement fusion, hydrogen isotopes are fused together under high pressures and temperatures. Typically, the duration of these experiments is incredibly short, on the order of around 60–150 ps. Due to the high radiation environment, a detector’s signal is typically data linked far distances to a protected location. The diagnostic challenge for fusion reaction history measurements is to measure signals of interest maximizing dynamic range while also maintaining time resolution on the order of 10 ps. In this work, we present a new experimental optical data link used to efficiently transport diagnostic signals over great distances to the recording system while not restricting the dynamic range. The concept of a three phase Mach–Zehnder modulator system is introduced as well as a description of the physical prototype. The initial results from testing at the OMEGA facility show that this system is a viable method for signal transportation.
Conditions of the applicability of equations in the quasi-static approximation for studying the parametric interaction of frequency-modulated light beams in multistage amplifiers are considered. This approximation is used to simulate numerically processes in a multistage DKDP crystal amplifier with the output power exceeding 10 PW and suppressed luminescence. (lasers and amplifiers)
Using bismuth/erbium-doped optical fibre, we have fabricated the first optical amplifier with a gain of ∼10 dB in a wide spectral range (1520−1770 nm), which covers the C-, L- and U-bands. (letters)
One of the challenges of electron density measurements of an atmospheric pressure plasma (APP) with a laser interferometer is the significant and unwanted phase shift caused by changes in the neutral gas density. These unwanted phase shifts can be mitigated and plasma density measured using an interferometer architecture called a dispersion interferometer (DI). A DI is composed of two nonlinear orientation patterned GaAs crystals for frequency doubling and measures the phase shift induced by a plasma in the interference signal between two second-harmonic beams. Measurement of plasma dynamics or a short plasma pulse in less than a millisecond is enabled with heterodyne detection in a DI using an acousto-optic cell with a frequency of 40 MHz. This heterodyne DI (HDI) is targeted to measure APPs in an electron density range of 10 20 –10 24 m −3 . Finally, the HDI achieves a line-integrated density resolution of 2 × 10 15 m −2 (a phase resolution of 0.005°) with a time constant of 1 μs using ensemble averaging techniques.
Explore the source record for details and available documents.
Abstract The PCI diagnostic is an internal reference interferometer that creates an image of absolutely calibrated electron density fluctuations integrated along the line of sight of the probing light beam. While conventional PCI diagnostics installed on fusion experiments worldwide employ light of wavelength equal to 10.59 μm, the same system using light at 1.55 μm wavelength would extend the spectral response in wave-number and frequency by factors of seven and over one hundred, respectively, thereby potentially providing quantitative measurements of the internal structure of density perturbations induced by either turbulent or radio-frequency waves, simultaneously covering ion to electron gyro-radius scales up to the GHz frequency region. Based on a previously developed 1.55 μm PCI prototype system, constraints to the design for such a diagnostic in fusion grade devices are presented and compared to those faced with the conventional method.