Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Balloon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Evolution of the NASA long-duration balloon program

The development of long-duration ballooning techniques to support flights of 1-2 ton payloads for periods up to 2 weeks, possibly even longer, offers a near-space scientific mission capability with an order of magnitude improvement over traditional balloon flights. This revolution in scientific research ballooning began with the solution of the manufacturing difficulties that plagued the program in the first half of the 1980's, and it has culminated in the early 1990's with three successive circumnavigations of the Antarctic continent in 9 to 14 day flights. A complementary capablity in the Northern hemisphere, which would approximately double the number of flights that could be supported each year, is needed to accommodate the trend for conventional payloads to be modified, or developed, for long-duration flights. Plans are already underway to employ the order-of-magnitude increased flight time for support of multi-flight research programs that will produce results comparable to some space missions. An overview of the current status and near-term plans for ballooning will be presented, along with a discussion of some major science initiatives that have been enabled.

Jones, W. Vernon↗

Global electrodynamics from superpressure balloons

Electric field and conductivity measurements in the stratosphere between November 1992 and March 1993 have been made using superpressure balloons in the southern hemisphere. Over 400 payload-days of data have been made during a record setting experiment called ELBBO (Extended Life Balloon Borne Observatories). This experiment resulted in 4 flights aloft simultaneously for over 2 months including one flight which lasted over 4 months. Electrodynamical coupling between the atmosphere and ionosphere is studied using the measured electric fields, and a simple empirical model of the stratospheric conductivity. Altitude profiles of conductivity have been obtained from several superpressure balloon flights using the large end-of-flight altitude swings on the last few days of each flight (as the balloon begins to loose superpressure). Coupling between the fields and atmospheric inertial waves has been observed. Effects and dynamics of the global circuit suggest that standard models are missing significant phenomena. Large scale ionospheric convection activity has been studied from the polar cap to the middle latitudes. Cusp latitude fields have been continuously measured for many days in a row.

Holzworth, R. H.↗

Substances To Fill Lighter-Than-Air Balloons

Various combinations of solid and liquid chemicals proposed as sources of hydrogen and other gases for inflating lighter-than-air balloons. In all cases energy used to propel balloon upward or downward comes from temperature differences in planet's atmosphere itself. Phase changes and/or reversible chemical reactions used to vary quantities of gases in balloons as functions of pressure and temperature and, as functions of altitude: provides means to control altitude of balloon.

Jones, Jack A.↗

Use of a Magnetic Azimuth-Indicator System Developed for Balloon Payloads of the Planetary Entry Parachute Program

An azimuth-sensing system was used for continuous ground monitoring of the azimuth orientation of the balloon-borne Planetary Entry Parachute Program (PEPP) spacecraft. The system utilized two magnetic field sensors located in the spacecraft so as to produce a unique set of voltage outputs for any azimuth. Electronics onboard the spacecraft encoded the magnetometer outputs and fed the encoded signal to a C-band modulator which imposed the intelligence onto the radar tracking beacon pulses. A conveniently located ground radar received the modulated pulses and the magnetometer outputs were reproduced after demodulation. For fast, direct readout, an X-Y plotter was calibrated to cross plot the reproduced signal of the two magnetometers on a combination rectangular-polar graph indicating the correct true azimuth in real time. The method was used successfully on three of the PEPP balloon-borne spacecraft to determine when the spacecraft was pointed in the most advantageous direction for release from the balloon, at 130,000 ft altitude. The use of such a system of azimuth monitoring is suitable to balloon payloads which are virtually stable with respect to the horizontal but may be rotating about the vertical axis. Angular accuracies within plus or minus 10 deg. could generally be expected.

Darnell, Wayne L.↗

Gamma Ray Large Area Space Telescope (GLAST) Balloon Flight Engineering Model: Overview

The Gamma Ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT) is a pair-production high-energy (greater than 20 MeV) gamma-ray telescope being built by an international partnership of astrophysicists and particle physicists for a satellite launch in 2006, designed to study a wide variety of high-energy astrophysical phenomena. As part of the development effort, the collaboration has built a Balloon Flight Engineering Model (BFEM) for flight on a high-altitude scientific balloon. The BFEM is approximately the size of one of the 16 GLAST-LAT towers and contains all the components of the full instrument: plastic scintillator anticoincidence system (ACD), high-Z foil/Si strip pair-conversion tracker (TKR), CsI hodoscopic calorimeter (CAL), triggering and data acquisition electronics (DAQ), commanding system, power distribution, telemetry, real-time data display, and ground data processing system. The principal goal of the balloon flight was to demonstrate the performance of this instrument configuration under conditions similar to those expected in orbit. Results from a balloon flight from Palestine, Texas, on August 4, 2001, show that the BFEM successfully obtained gamma-ray data in this high-background environment.

Thompson, D. J.↗

CdZnTe Background Measurements at Balloon Altitudes with PoRTIA

Measurements of the CdZnTe internal background at balloon altitudes are essential to determine which physical processes make the most important background contributions. We present results from CdZnTe background measurements made by PoRTIA, a small CdZnTe balloon instrument that was flown three times in three different shielding configurations. PoRTIA was passively shielded during its first flight from Palestine, Texas and actively shielded as a piggyback instrument on the GRIS balloon experiment during its second and third flights from Alice Springs, Australia, using the thick GRIS Nal anticoincidence shield. A significant CdZnTe background reduction was achieved during the third flight with PoRTIA placed completely inside the GRIS shield and blocking crystal, and thus completely surrounded by 15 cm of Nal. A unique balloon altitude background data set is provided by CdZnTe and Ge detectors simultaneously surrounded by the same thick anticoincidence shield; the presence of a single coxial Ge detector inside the shield next to PoRTIA allowed a measurement of the ambient neutron flux inside the shield throughout the flight. These neutrons interact with the detector material to produce isomeric states of the Cd, Zn and Te nuclei that radiatively decay; calculations are presented that indicate that these decays may explain most of the fully shielded CdZnTe background.

Parsons, A.↗

Lavoisier: A Low Altitude Balloon Network for Probing the Deep Atmosphere and Surface of Venus

The in-situ exploration of the low atmosphere and surface of Venus is clearly the next step of Venus exploration. Understanding the geochemistry of the low atmosphere, interacting with rocks, and the way the integrated Venus system evolved, under the combined effects of inner planet cooling and intense atmospheric greenhouse, is a major challenge of modern planetology. Due to the dense atmosphere (95 bars at the surface), balloon platforms offer an interesting means to transport and land in-situ measurement instruments. Due to the large Archimede force, a 2 cubic meter He-pressurized balloon floating at 10 km altitude may carry up to 60 kg of payload. LAVOISIER is a project submitted to ESA in 2000, in the follow up and spirit of the balloon deployed at cloud level by the Russian Vega mission in 1986. It is composed of a descent probe, for detailed noble gas and atmosphere composition analysis, and of a network of 3 balloons for geochemical and geophysical investigations at local, regional and global scales.

Chaasefiere, E.↗

Balloon-Borne, High-Energy Astrophysics: Experiences from the 1960s to the 1980s

Observational high-energy astrophysics in the hard-x-ray and gamma-ray regions owes its development and initial successes to the balloon-borne development of detector systems, as well as pioneering observations, primarily in the timeframe from the 1960s to the 1990s. I will describe some of the first observations made by the Rice University balloon group in the 1960s, including the impetus for these observations. The appearance of SN 1987a led to several balloon-flight campaigns, sponsored by NASA, from Alice Springs, Australia in 1987 and 1988. During the 1980s, prototypes of instruments for the Compton Gamma Ray Observatory were flown on many balloon flights, which greatly enhanced the success of that mission.

Fishman, Gerald J.↗

Meshed-Pumpkin Super-Pressure Balloon Design

An improved, lightweight design has been proposed for super-pressure balloons used to carry scientific instruments at high altitudes in the atmosphere of Earth for times as long as 100 days. [A super-pressure balloon is one in which the pressure of the buoyant gas (typically, helium) is kept somewhat above ambient pressure in order to maintain approximately constant density and thereby regulate the altitude.] The proposed design, called "meshed pumpkin," incorporates the basic concept of the pumpkin design, which is so named because of its appearance. The pumpkin design entails less weight than does a spherical design, and the meshed-pumpkin design would reduce weight further. The basic idea of the meshed-pumpkin design is to reinforce the membrane of a pumpkin balloon by attaching a strong, lightweight fabric mesh to its outer surface. The reinforcement would make it possible to reduce the membrane mass to one-third or less of that of the basic pumpkin design while retaining sufficient strength to enable the balloon to remain at approximately constant altitude for months.

Jones, Jack↗

Development of a Display Tool to Quality Control Weather Balloon Data for Space Launch Vehicles Using Python

Continuous atmospheric data analysis is an important factor for space launch vehicle design and operations. The balloon quality control tool was developed by NASA’s Marshall Space Flight Center (MSFC) Natural Environments Branch (NEB) for monitoring quality control processes and verifying the automated flags created on the balloon data sets analyzed. The data sets currently analyzed are comprised of high-resolution and low-resolution balloon data from NASA Kennedy Space Center (KSC), co-located on the United States Air Force’s Eastern range (ER) at the Cape Canaveral Air Force Station. The NEB was tasked to perform a quality assessment of these data sets and needed a tool to confirm the quality control (QC) flags produced from an automated process and add additional QC flags if necessary. This Graphical User Interface (GUI) was developed to visualize all of the data from these balloon sets, display any flags from the automated QC process, and add additional flags to variables if necessary. The GUI was developed in Python 3.6 utilizing different packages available such as pandas for data analysis and manipulation, NumPy for high-performance multidimensional array and tools to compute with and manipulate arrays, Matplotlib for plotting data and Tkinter to build the GUI.

Jessica K Headley↗

Development of a Display Tool to Quality Control Weather Balloon Data for Space Launch Vehicles

Continuous atmospheric data analysis is an important factor for space launch vehicle design and operations. The balloon quality control tool was developed by NASA’s Marshall Space Flight Center (MSFC) Natural Environments Branch (NEB) for monitoring quality control processes and verifying the automated flags created on the balloon data sets analyzed. The data sets currently analyzed are comprised of high-resolution and low-resolution balloon data from NASA Kennedy Space Center (KSC), co-located on the United States Air Force’s Eastern range (ER) at the Cape Canaveral Air Force Station. The NEB was tasked to perform a quality assessment of these data sets and needed a tool to confirm the quality control (QC) flags produced from an automated process and add additional QC flags if necessary. This Graphical User Interface (GUI) was developed to visualize all of the data from these balloon sets, display any flags from the automated QC process, and add additional flags to variables if necessary. The GUI was developed in Python 3.6 utilizing different packages available such as pandas for data analysis and manipulation, NumPy for high-performance multidimensional array and tools to compute with and manipulate arrays, Matplotlib for plotting data and Tkinter to build the GUI.

Jessica K Headley↗

SuperHERO (Super - High Energy Replicated Optics) Balloon Mission Concept

The SuperHERO hard-x-ray telescope is a proposed high-angular resolution successor to Marshall Space Flight Center’s (MSFC) successful High Energy Replicated Optic (HERO) and the HERO to Explore the Sun (HEROES) balloon missions. By utilizing recent advancements in MSFC’s replicated full shell, NiCo x-ray optic technology, SuperHERO will achieve its technical goal of demonstrating better than 10 arcseconds (arcsecs) angular resolution in half-power diameter (HPD) on a balloon platform. This represents a 6-fold improvement to the current state-of-the-art resolution for hard-x-ray, astrophysical telescopes and will allow for the observation of the high-energy-universe in unprecedented spatial detail. The SuperHERO balloon observatory will consist of seven coaligned, identical telescopes with a total focal length of 12-meters. Each telescope will pair a Mirror Module Assembly (MMA) comprised of NiCo shell optics matched to a CdTe Double-sided Strip Detector (CdTe-DSD) plane provided by iMAGINE-X Inc. and Kavli Institute for the Physics and Mathematics of the Universe (Kavli-IPMU). Iridium coating applied directly to each shell will boost reflectivity into the hard-x-ray regime. Employing additional high-heritage technology, SuperHERO will have an open-truss carbon-composite gondola similarly used on the XL-Calibur balloon mission and will use the Wallops Arc-Second Pointer (WASP) system for attitude control

NickThomas↗

Radio frequency tuning of dressed multicell cavities using pressurized balloons

Methods and systems for non-invasively tuning dressed multicell cavities. A multicell cavity can be plastically deformed as result of introducing a customized balloon to a cavity and then pressurizing the balloon to a targeted cell while applying a global force on the cavity flanges. The pressurized balloons localize the plastic deformation to the targeted cells using prescribed values of both global force and balloon pressure. Such an approach allows for the tuning of dressed cavities without removal of the helium vessel.

43 PARTICLE ACCELERATORS↗

Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54-86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Intrahepatic Biliary Leak: A Modified Occlusion Balloon Technique

PurposeTo report a novel modified occlusion balloon technique to treat biliary leaks.MethodsA 22-year-old female patient underwent liver transplantation with biliary-enteric anastomosis. She developed thrombosis of the common hepatic artery and extensive ischemia in the left hepatic lobe. Resection of segments II and III was performed and a biliary-cutaneous leak originating at the resection plane was identified in the early postoperative period. Initial treatment with percutaneous transhepatic drainage was unsuccessful. Therefore, an angioplasty balloon was coaxially inserted within the biliary drain and positioned close to the leak.ResultsThe fistula output abruptly decreased after the procedure and stopped on the 7th day. At the 3-week follow-up, cholangiography revealed complete resolution of the leakage.ConclusionThis novel modified occlusion balloon technique was effective and safe. However, greater experience and more cases are necessary to validate the technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transjugular Intrahepatic Portosystemic Shunt Flow Reduction with Adjustable Polytetrafluoroethylene-Covered Balloon-Expandable Stents Using the “Sheath Control” Technique

PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloon retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Software-Assisted Hemodynamic Evaluation of Pelvic Flow During Chemoperfusion of Pelvic Arteries for Bladder Cancer: Double- Versus Single-Balloon Technique

PurposeApproximately 83 % of patients with bladder cancer have achieved a complete response after undergoing a novel bladder preservation therapy involving balloon-occluded intra-arterial infusion chemotherapy (BOAI) using a four-lumen double-balloon catheter, known as the Osaka Medical College regimen. This study aimed to show the quantitative difference in hemodynamics of the bladder arteries using syngo iFlow (Siemens Healthcare, Erlangen, Germany), which provides an automatic tool for quantitative blood flow analysis between double BOAI (D-BOAI) and conventional single BOAI (S-BOAI).Materials and MethodsFifty patients were included. The catheters were introduced into both posterior trunks of the internal iliac arteries via contralateral femoral artery access. A side hole between the distal and proximal balloons was placed at the origin of each bladder artery to allow clear visualization of angiographic flow of the injected agent into the urinary bladder. Digital subtraction angiography was used during analysis with the syngo iFlow to evaluate the hemodynamics of the contrast medium in the pelvic arteries during BOAI. The comparative change in the amount of contrast medium in the bladder arteries between D-BOAI and S-BOAI was assessed using syngo iFlow.ResultsOne-hundred pelvic sides were analyzed. The amount of contrast medium in the bladder arteries using D-BOAI was more than twice that using S-BOAI (right, 3.03-fold; left, 2.81-fold).ConclusionThe amount of contrast medium in the bladder arteries using D-BOAI was higher than that using conventional S-BOAI. This may increase the anticancer drug concentration in the affected bladder, leading to a good clinical response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pharmacokinetic Evaluation of Two Paclitaxel-Coated Balloons with Different Drug Load in a Short-Term Porcine Study

PurposeThe aim of the study was to evaluate the pharmacokinetics and tissue absorption of 2 paclitaxel (PTX) drug-coated balloons (DCB) using different drug loads in a porcine-injured iliac artery model.Materials and MethodsTwenty-eight pigs were randomized into 2 groups. In group B1, angioplasty was performed with a 1.0 µg/mm{sup 2} DCB with PTX and in group B3, with a 3.0 µg/mm{sup 2} DCB with PTX. An overstretched model of the iliac artery was used for angioplasty under fluoroscopy. Blood and vessel wall PTX were measured with liquid-chromatography mass spectrometry at 1, 5, 30 min, 1, 7, and 28 days. Remaining drug in the balloon was analyzed.ResultsMean PTX in blood was significantly higher in the group B3 0.269 ± 0.085 µg/ml compared with the B1 0.218 ± 0.085 µg/ml; p = 0.01. Peak blood PTX concentration was detected at 1 min, and PTX was undetectable 24 h post-angioplasty. There were no statistically significant differences in the mean arterial wall concentration from the treated iliac artery between group-B1 (15.24 ± 21.29 ng/mg) and B3 (15.68 ± 16.33 ng/mg), or in the PTX wall concentration measured at different time points. Mean remaining drug in assayed balloons was lower for group-B1 and represented 8 % of the initial dose.ConclusionsBlood PTX was higher when using 3.0 µg/mm{sup 2} DCB, with a peak drug concentration at 1-min, although the drug was undetectable at 24 h, independently of the loading dose. This study demonstrates no difference in arterial wall uptake of a low dose DCB (1.0 µg/mm{sup 2}), when compared to a common dose DCB (3.0 µg/mm{sup 2}) suggesting that the dose of drug in the DCB could be reduced obtaining a similar clinical effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗