Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Generation and manipulation of proton beams by ultra-short laser pulses

Applying a 21-channel Thomson spectrometer setup has revealed further insight to the connection between spatial and spectral beam characteristic of laser accelerated protons. Analyzing the central emission cone (plus/minus 3 degree) shows an increasing beam divergency for protons with increasing kinetic energies. This holds for protons emitted from the same source area at the target surface. The whole beam is a well ordered system with a clear functional dependence of trajectories on proton energy. This is a consequence of the source dynamics which is determined by the sheath development in time. Thus laser-driven ion beams can be advantageously manipulated for further propagation to an experiment. We demonstrate this capability with a magnetic quadrupole and obtain a nearly parallel and monochromatized beam. Furthermore we set our achievements in beam production efficiency into context with other laser systems and demonstrate the potential of very-thin target foils.

43 PARTICLE ACCELERATORS↗

An integral quality monitoring system for real-time verification of intensity modulated radiation therapy

Purpose: To develop an independent and on-line beam monitoring system, which can validate the accuracy of segment-by-segment energy fluence delivery for each treatment field. The system is also intended to be utilized for pretreatment dosimetric quality assurance of intensity modulated radiation therapy (IMRT), on-line image-guided adaptive radiation therapy, and volumetric modulated arc therapy. Methods: The system, referred to as the integral quality monitor (IQM), utilizes an area integrating energy fluence monitoring sensor (AIMS) positioned between the final beam shaping device [i.e., multileaf collimator (MLC)] and the patient. The prototype AIMS consists of a novel spatially sensitive large area ionization chamber with a gradient along the direction of the MLC motion. The signal from the AIMS provides a simple output for each beam segment, which is compared in real time to the expected value. The prototype ionization chamber, with a physical area of 22x22 cm{sup 2}, has been constructed out of aluminum with the electrode separations varying linearly from 2 to 20 mm. A calculation method has been developed to predict AIMS signals based on an elementwise integration technique, which takes into account various predetermined factors, including the spatial response function of the chamber, MLC characteristics, beam transmission through the secondary jaws, and field size factors. The influence of the ionization chamber on the beam has been evaluated in terms of transmission, surface dose, beam profiles, and depth dose. The sensitivity of the system was tested by introducing small deviations in leaf positions. A small set of IMRT fields for prostate and head and neck plans was used to evaluate the system. The ionization chamber and the data acquisition software systems were interfaced to two different types of linear accelerators: Elekta Synergy and Varian iX. Results: For a 10x10 cm{sup 2} field, the chamber attenuates the beam intensity by 7% and 5% for 6 and 18 MV beams, respectively, without significantly changing the depth dose, surface dose, and dose profile characteristics. An MLC bank calibration error of 1 mm causes the IQM signal of a 3x3 cm{sup 2} aperture to change by 3%. A positioning error in a single 5 mm wide leaf by 3 mm in 3x3 cm{sup 2} aperture causes a signal difference of 2%. Initial results for prostate and head and neck IMRT fields show an average agreement between calculation and measurement to within 1%, with a maximum deviation for each of the smallest beam segments to within 5%. When the beam segments of a prostate IMRT field were shifted by 3 mm from their original position, along the direction of the MLC motion, the IQM signals varied, on average, by 2.5%. Conclusions: The prototype IQM system can validate the accuracy of beam delivery in real time by comparing precalculated and measured AIMS signals. The system is capable of capturing errors in MLC leaf calibration or malfunctions in the positioning of an individual leaf. The AIMS does not significantly alter the beam quality and therefore could be implemented without requiring recommissioning measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pin diode calibration - beam overlap monitoring for low energy cooling

We were trying to address the question whether or not the Pin Diodes, currently installed approximately 1 meter downstream of the RHIC primary collimators, are suitable to monitor a recombination signal from the future RHIC low energy cooling section. A maximized recombination signal, with the Au+78 ions being lost on the collimator, will indicate optimal Au-electron beam overlap as well as velocity matching of the electron beam in the cooling section.

43 PARTICLE ACCELERATORS↗

A novel digitization scheme with FPGA-base TDC for beam loss monitors operating at cryogenic temperature

Recycling integrators are common current-to-frequency converting circuits for measurements of low current such as that produced by Fermilab's cryogenic ionization chambers. In typical digitization/readout schemes, a counter is utilized to accumulate the number of pulses generated by the recycling integrator to adequately digitize the total charge. In order to calculate current with reasonable resolution (e.g., 7-8 bits), hundreds of pulses must be accumulated which corresponds to a long sampling period, i.e., a very low sampling rate. In our new scheme, an FPGA-based Time-to-Digital Convertor (TDC) is utilized to measure the time intervals between the pulses output from the recycling integrator. Using this method, a sample point of the current can be made with good resolution (>10 bits) for each pulse. This effectively increases the sampling rates by hundreds of times for the same recycling integrator front-end electronics. This scheme provides a fast response to the beams loss and is potentially suitable for accelerator protection applications. Moreover, the method is also self-zero-suppressed, i.e., it produces more data when the beam loss is high while it produces significantly less data when the beam loss is low.

43 PARTICLE ACCELERATORS↗

Development of fast (sub-minute) micro-tomography

An x-ray fast micro-tomography system was developed at medical and imaging beamline BL20B2 in SPring-8. We attempted a 'continuous rotation method' whereby the sample keeps rotating in the beam during the measurement. The image acquisitions are synchronized with the trigger pulses branched from the stepper motor controller. An electron multiplier (EM)-CCD camera (C9100-02, 1000x1000 pixels, 30 fps, 8 {mu}m/pixel, Hamamatsu Photonics) and beam-monitor AA40P (Hamamatsu Photonics) were used as an image detector. The effective pixel size of the detector was 4.9 {mu}m/pixel and the spatial resolution was about 15 {mu}m. The total measurement time for 900 projections has been reduced to 36 s. The reconstruction time was also reduced using GPGPU and SSD system. Using these techniques, preliminary experiment for 4-D (time resolved 3-D) micro-imaging has also been performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Monitor for SuperKEKB HER/LER to Monitor Vertical Beam Size Bunch-by-Bunch

The beginning of the period of performance for this grant began after we had designed a Printed Circuit Board (PCB) for biasing and transporting signals from a new, thin Silicon strip sensor made at the Stanford Nanofabrication facility. This complex PCB was manufactured in mid-2017, and then work began on a preamplifier design that would take signals from the sensor and provide sufficient gain while maintaining fidelity, in terms of noise figure and signal speed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of experimental and computational frameworks to predict subcooled flow boiling in the LANL Isotope Production Facility

Cooling is crucial to maintain the integrity of target systems in isotope production facilities. At Los Alamos National Laboratory (LANL)’s Isotope Production Facility (IPF), multiple encapsulated targets are stacked and irradiated in tandem with a 100 MeV, ~250μA proton beam. To facilitate effective heat removal, these stacked targets are separated and cooled via a series of water channels. At these beam currents, this high-energy proton beam heats the target system, likely initiating subcooled flow boiling in the cooling channels. However, in-beam monitoring of the IPF target system is not possible due to the extreme radiation environment, and the necessarily significant shielding. To better understand high-power target performance, we developed ex-situ experimental and computational frameworks to predict the behavior of subcooled flow boiling at IPF. Subcooled flow boiling experiments on Inconel 625 samples under IPF conditions (2 bar pressure, 10 GPM flow rate (i.e., 2249 kg/m 2 /s), 85 K subcooling) revealed that IPF's average operating power is at the early stage of boiling with a heat transfer coefficient of 48,000 W/m 2 /s. The proposed modeling framework enables us to predict a complete boiling curve, i.e., single-phase heat transfer, onset of nucleate boiling, two-phase heat transfer, and critical heat flux (CHF), with specification of input boiling parameters up to intermediate heat flux levels. The estimated CHF under IPF conditions is 5.2 MW/m 2 . Experimental data under reduced conditions (2 bar pressure, 1.5 GPM flow rate (i.e., 337 kg/m 2 /s), 45 K subcooling) served as validation cases for the computational modeling. This computational model can be further extended to more complicated systems replicating the real IPF configuration, for instance, to study void distribution as a function of the incident proton beam profile and coolant velocity profile of multiple cooling channels. Finally, the proposed experimental and computational frameworks provide a means to better understand cooling systems in the isotope production facilities at different accelerators, where in-beam monitoring of the cooling process is not available.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of the proton beam from an IBA Cyclone 18/9 with radiochromic film EBT2

The use of radiochromic films is widespread in different areas of medical physics like radiotherapy and hadrontherapy; however, radiochromic films have been scarcely used in the characterization of proton or deuteron beams generated in biomedical cyclotrons. In this paper the radiochromic film EBT2 was used to study the beam size and the proton beam energy of an IBA Cyclone 18/9 cyclotron. The results indicate that the beam size can be easily measured at a very low expense; however, an accurate determination of the beam energy might require the implementation of certain experimental improvements.

43 PARTICLE ACCELERATORS↗

DarkLight radiation backgrounds

We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-on, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that need to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW CW beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, field emission inside the niobium cavities of the accelerator cryomodules is the primary source of ambient radiation.

43 PARTICLE ACCELERATORS↗