Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM FOCUSING MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Aberration of a negative ion beam caused by space charge effect

Aberrations are inevitable when the charged particle beams are extracted, accelerated, transmitted, and focused with electrostatic and magnetic fields. In this study, we investigate the aberration of a negative ion accelerator for a neutral beam injector theoretically, especially the spherical aberration caused by the negative ion beam expansion due to the space charge effect. The negative ion current density profiles with the spherical aberration are compared with those without the spherical aberration. It is found that the negative ion current density profiles in a log scale are tailed due to the spherical aberration.

43 PARTICLE ACCELERATORS↗

Final-focus Superconducting Magnets for SuperKEKB

The SuperKEKB collider aims at 40 times higher luminosity than that achieved at KEKB, based on the nano-beam scheme. The vertical beta function at the interaction point will be squeezed to 300μmeter. Final-focus superconducting magnet system which consists of eight main quadrupole magnets, 43 corrector windings, and compensation solenoids is a key component to achieve high luminosity. This invited talk presents the construction and commissioning of the final-focus magnet system.

43 PARTICLE ACCELERATORS↗

Gantry for medical particle therapy facility

A particle therapy gantry for delivering a particle beam to a patient includes a beam tube having a curvature defining a particle beam path and a plurality of fixed field magnets sequentially arranged along the beam tube for guiding the particle beam along the particle path. In a method for delivering a particle beam to a patient through a gantry, a particle beam is guided by a plurality of fixed field magnets sequentially arranged along a beam tube of the gantry and the beam is alternately focused and defocused with alternately arranged focusing and defocusing fixed field magnets.

60 APPLIED LIFE SCIENCES↗

Gantry for medical particle therapy facility

A particle therapy gantry for delivering a particle beam to a patient includes a beam tube having a curvature defining a particle beam path and a plurality of superconducting, variable field magnets sequentially arranged along the beam tube for guiding the particle beam along the particle path. In a method for delivering a particle beam to a patient through a gantry, a particle beam is guided by a plurality of variable field magnets sequentially arranged along a beam tube of the gantry and the beam is alternately focused and defocused with alternately arranged focusing and defocusing variable field magnets.

43 PARTICLE ACCELERATORS↗

Nuclear structure analysis using the Orange Spectrometer

Recently, an Orange spectrometer, a focusing iron-free magnetic spectrometer, has been installed at a beam line of the 10 MV Tandem accelerator of the IKP of the University of Cologne. The high efficiency of 15% of 4{pi} for the detection of conversion electrons and the energy resolution of 1% makes the Orange spectrometer a powerful instrument. From the conversion electron spectrum, transition multipolarities can be determined using the so called K to L ratio. In combination with an array of germanium and lanthanum bromide detectors, e{sup -}-{gamma}-coincidences can be performed to investigate the level scheme. Moreover, the very fast lanthanum bromide scintillator with an energy resolution of 3% allows e{sup -}-{gamma} lifetime measurements down to 0.3 ns. A second Orange spectrometer can be added to build the Double Orange Spectrometer for e{sup -}-e{sup -}-coincidences. It is indispensable for lifetime measurements of low intensity or nearby lying transitions as often occur in odd-A and odd-odd nuclei. The capabilities are illustrated with several examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma Lens for a US Based Super Neutrino Beam

The plasma lens concept is examined as an alternative to focusing horns and solenoids for a neutrino beam facility. The concept is based on a combined high-current lens/target configuration. Current is fed at an electrode located downstream from the beginning of the target where pion capturing is needed. The current is carried by plasma outside the target. A second plasma lens section, with an additional current feed, follows the target. The plasma is immersed in a solenoidal magnetic field to facilitate its current profile shaping to optimize pion capture. Simulations of the not yet fully optimized configuration yielded a 25% higher neutrino flux at a detector situated at 3 km from the target than the horn system for the entire enegry spectrum and a factor of 2.47 higher flux for neutrinos with energy larger than 3 GeV. A major advantage of plasma lenses is in background reduction. In anti-neutrino operation, neutrino background is reduced by a factor of close to 3 for the whole spectrum, and for and for energy larger than 3 GeV; neutrino background is reduced by a factor of 3.6. Plasma lens advantages are due to: larger axial currents, high signal purity: minimal neutrino background in anti-neutrino runs. Additionally the lens medium consists of plasma, consequently, particle absorption and scattering is negligible. Withstanding high mechanical and thermal stresses in a plasma is not an issue.

43 PARTICLE ACCELERATORS↗

Reasonable Beam Deviation Envelope for Ray-tracing

At NSLS-II the unused dipole radiation is intercepted by the photon absorbers installed inside the vacuum chamber. The water-cooled absorbers are designed to take away the heat therefore the temperature is kept within the safety limit. However, if the beam orbit is severely perturbed, the radiation fan could pass through the geometry and strikes on the vacuum chamber components. This ray-leakage is a possible reason of the accelerator component temperature rise observed during the high-current operations. The goal of this work is to find the maximum beam deviation at the dipole hence ray-tracing can be re-examined under the operational constraints. The beam is confined to the orbit by the bending and focusing magnets. At NSLS-II the orbit is further controlled by a real time orbit feedback loop. Beam could be lost in any unpredictable direction if the magnet malfunctions. Consequently reasonable assumptions must be made to define the deviation envelope. It was determined that the dipole radiation is not powerful enough to cause damage within 10 ms, for example, if the rf power is shut off and the beam deviates from the orbit. Therefore we consider the radiation produced by the stored beam only; temporarily processes, such as unstable oscillating beam, should not be a concern. The orbit of the stored beam can be altered during magnet failures. The dipole current is interlocked to a small range of ±2% from the nominal value. If the dipole current changes slowly the beam energy automatically adjusts and the orbit remains the same. If the dipole current changes rapidly the beam will not be stable. Therefore dipole variation need not to be considered. For the other magnets we consider one magnet failure at a time because it is unlikely that two fail at the same time. It was found that the beam lifetime drops dramatically if one quadrupole power supply is turned off; therefore this scenario does not meet the stable beam condition. The current of one quadrupole could drop but will not result in orbit change with the feedback on. Beam could survive if one sextupole power supply is turned off, but the orbit will not be changed. Magnet could partially fail, for example, one or part of the coil shorts due to break-down. This is a low probability event and will not be considered. During daily operations the orbit is changed by the correctors and the rf frequency. In this work the correctors and the rf frequency are varied to explore the deviation envelope.

36 MATERIALS SCIENCE↗

The RHIC Polarized Source Upgrade

The basic limitations on the high-intensity H - ion beam production were experimentally studied in charge-exchange collisions of the neutral atomic hydrogen beam in the Na- vapor jet ionizer cell. These studies are the part of the polarized source upgrade (to 10 mA peak current and 85% polarization) project for RHIC. In the source the atomic hydrogen beam of a 5-10 keV energy and total (equivalent) current up to 5 A is produced by neutralization of proton beam in pulsed hydrogen gas target. Formation of the proton beam (from the surface of the plasma emitter with a low transverse ion temperature ~0.2 eV) is produced by four-electrode spherical multi-aperture ion-optical system with geometrical focusing. The hydrogen atomic beam intensity up t o 1.0 A /cm 2 (equivalent) was obtained in the Na-jet ionizer aperture of a 2.0 cm diameter. At the first stage of the experiment H- beam with 36 mA current, 5 keV energy and ~1.0 cm·mrad normalized emittance was obtained using the flat grids and magnetic focusing. The experimental results of the high-intensity neutral hydrogen beam generation and studies of the charge-exchange polarization processes of this intense beam will be presented.

43 PARTICLE ACCELERATORS↗

Periodic permanent magnet focused klystron

A periodic permanent magnet (PPM) klystron has beam transport structures and RF cavity structures, each of which has permanent magnets placed substantially equidistant from a beam tunnel formed about the central axis, and which are also outside the extent of a cooling chamber. The RF cavity sections also have permanent magnets which are placed substantially equidistant from the beam tunnel, but which include an RF cavity coupling to the beam tunnel for enhancement of RF carried by an electron beam in the beam tunnel.

43 PARTICLE ACCELERATORS↗

Electron Accelerator Lattice Design for LHeC with Permanent Magnets

We present a new ’green energy’ approach to the Energy Recovery Linac (ERL) the future Electron Ion Collider at LHeC using single beam line made of very strong focusing combined function permanent magnets and the Fixed Field Alternating Linear Gradient (FFA-LG) principle. We are basing our design on recent very successful commissioning results of the Cornell University and Brookhaven National Laboratory ERL Test Accelerator-CBETA.

Trbojevic, D.↗

Spatially resolved measurements of electron cyclotron resonance ion source beam profile characteristics

Simulations predict that the concentric rings and the triangular structures in the profiles of strongly focused ion beams that are found in different experiments should be dominated by ion species with the same or at least similar m/q-ratio. To verify these theoretical predictions we have tuned our ECR ion source to deliver a beam consisting of multiple ion species whose particular m/q-depending focusing ranges from weakly focused to overfocused. We then recorded spatially resolved charge-state distributions of the beam profile at characteristic positions in the plane perpendicular to the beam line. The results validate theoretical predictions and are summarized in this paper. To achieve the required beam profile characteristics we moved the extraction along the beam line to achieve stronger focusing than by only changing the extraction voltage. To fit the regions of interest of the beam profile into the transmission area of the sector magnet, we steered the beam by moving the extraction in the plane perpendicular to the beam axis. The results of both investigations, beam focusing and beam steering by using a 3D-movable extraction, are also reported in this paper. A brief overview of the new beam monitor extensively used during these measurements, the Faraday cup array, is also given.

43 PARTICLE ACCELERATORS↗

Artificial dense lattice of magnetic bubbles

Co/Pt multilayers with perpendicular magnetic anisotropy are irradiated by focused He{sup +} ion beam to locally reduce the anisotropy value. The irradiated spots with a diameter of 100 nm are arranged in a square lattice with 200 nm period. The formation of the nonuniform periodic magnetic structure is observed without changes in the film topography. The spatial symmetry of the magnetic force microscopy signal and the specific shape of magnetization curves indicate the formation of the magnetic bubbles or magnetic vortices within the irradiated spot depending on the irradiation dose. The experimental data are in a good agreement with micromagnetic simulations of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calculation of the parameters of the X-ray diffraction station with adaptive segmented optics on the side beam from the wiggler of the Sibir'-2 storage ring

The mounting of an X-ray diffraction station on the side beam of a 19-pole superconducting wiggler makes it possible not only to use the central synchrotron radiation beam with a wavelength of 0.5 Angstrom-Sign , but also to solve problems requiring softer X rays at a synchrotron radiation (SR) intensity exceeding that for the beams from the bending magnet. A numerical simulation of the formation of photon beams from a source and their transmission through the elements of the station (and through the station as a whole) allows one to calculate the parameters of the station, compare it with the existing analogs, determine its potential and actual efficiency of its elements, and estimate the adjustment quality. A numerical simulation of the SR source on the side beam from the wiggler and the focusing channel (segmented condenser mirror, monochromator with sagittal focusing by the segmented second crystal, and segmented focusing mirror) has been performed. The sizes of the focus and the divergence of rays in it are determined with allowance for the finite sizes of segments. The intensity of radiation with a wavelength {lambda} = 1.0 Angstrom-Sign in the focus is determined taking into account the loss in the SR extraction channel and in the focusing channel. The values of the critical wavelength for the side beam from the wiggler and the wavelength resolution are calculated. The intensities in the X-ray diffraction pattern and its angular resolution are found.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Status of MICE

The Muon Ionization Cooling Experiment (MICE) is an experiment currently under construction at the Rutherford Appleton Laboratory (RAL) in the UK. The aim of the experiment is to demonstrate the concept of ionization cooling for a beam of muons, crucial for the requirements of a Neutrino Factory and a Muon Collider. Muon cooling is achieved by measuring the reduction of the four dimensional transverse emittance for a beam of muons passing through low density absorbers and then accelerating the longitudinal component of the momentum using RF cavities. The absorbers are maintained in a focusing magnetic field to reduce the beta function of the beam and the RF cavities are kept inside coupling coils. The main goal of MICE is to measure a fractional drop in emittance, of order -10% for large emittance beams, with an accuracy of 1%(which imposes a requirement that the absolute emittance be measured with an accuracy of 0.1%). This paper will discuss the status of MICE, including the progress in commissioning the muon beam line at the ISIS accelerator at RAL, the construction of the different detector elements in MICE and the prospects for the future.

43 PARTICLE ACCELERATORS↗

Transport of a Low-Energy Beam from the Scorpius Accelerator to the Final-Focus Solenoid

It may be required to use Scorpius for low-energy radiography of hydrodynamic experiments, perhaps as low as the 2-MeV injected beam kinetic energy. As presently designed, the downstream transport (DST) system will not work for energies less than about 4.5 MeV due to space-charge defocusing. For energies less than that the beam envelope expands to the wall before the first magnet can catch and focus it. More solenoids would have to be added to the DST lattice in order to transport a beam with KE < 4.5 MeV to the final focus.

43 PARTICLE ACCELERATORS↗

W-Band Sheet Beam Klystron Design

Sheet beam devices provide important advantages for very high power, narrow bandwidth RF sources like accelerator klystrons [1]. Reduced current density and increased surface area result in increased power capabi1ity, reduced magnetic fields for focusing and reduced cathode loading. These advantages are offset by increased complexity, beam formation and transport issues and potential for mode competition in the ovennoded cavities and drift tube. This paper will describe the design issues encountered in developing a 100 kW peak and 2 kW average power sheet beam k1ystron at W-band including beam formation, beam transport, circuit design, circuit fabrication and mode competition.

43 PARTICLE ACCELERATORS↗

DESIGN OF VISIBLE DIAGNOSTIC BEAMLINE FOR NSLS2 STORAGE RING

A visible synchrotron light monitor (SLM) beam line has been designed at the NSLS2 storage ring, using the bending magnet radiation. A retractable thin absorber will be placed in front of the first mirror to block the central x-rays. The first mirror will reflect the visible light through a vacuum window. The light is guided by three 6-inch diameter mirrors into the experiment hutch. In this paper, we will describe design work on various optical components in the beamline. The ultra high brightness NSLS-II storage ring is under construction at Brookhaven National Laboratory. It will have 3GeV, 500mA electron beam circulating in the 792m ring, with very low emittance (0.9nm.rad horizontal and 8pm.rad vertical). The ring is composed of 30 DBA cells with 15 fold symmetry. Three damping wigglers will be installed in long straight sections 8, 18 and 28 to lower the emittance. While electrons pass through the bending magnet, synchrotron radiation will be generated covering a wide spectrum. There are other insertion devices in the storage ring which will generate shorter wavelength radiation as well. Synchrotron radiation has been widely used as diagnostic tool to measure the transverse and longitudinal profile. Three synchrotron light beam lines dedicated for diagnostics are under design and construction for the NSLS-II storage ring: two x-ray beam lines (pinhole and CRL) with the source points from Cell 22 BM{_}A (first bending in the DBA cell) and Cell22 three-pole wiggler; the third beam line is using visible part of radiation from Cell 30 BM{_}B (second bending magnet from the cell). Our paper focuses on the design of the visible beam line - SLM.

43 PARTICLE ACCELERATORS↗

Design Features of a Planar Hybrid/Permanent Magnet Strong Focusing Undulator for Free Electron Laser (FEL) And Synchrotron Radiation (SR) Applications

Insertion devices for Angstrom-wavelength Free Electron Laser (FEL) amplifiers driven by multi-GeV electron beams generally require distributed focusing substantially stronger than their own natural focusing fields. Over the last several years a wide variety of focusing schemes and configurations have been proposed for undulators of this class, ranging from conventional current-driven quadrupoles external to the undulator magnets to permanent magnet (PM) lattices inserted into the insertion device gap. In this paper we present design studies of a flexible high-field hybrid/PM undulator with strong superimposed planar PM focusing proposed for a 1.5 Angstrom Linac Coherent Light Source (LCLS) driven by an electron beam with a 1 mm-mr normalized emittance. Attainable field parameters, tuning modes, and potential applications of the proposed structure are discussed.

43 PARTICLE ACCELERATORS↗