Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Average Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Discontinuous Spectral Difference Method for Conservation Laws on Unstructured Grids

A new, high-order, conservative, and efficient discontinuous spectral finite difference (SD) method for conservation laws on unstructured grids is developed. The concept of discontinuous and high-order local representations to achieve conservation and high accuracy is utilized in a manner similar to the Discontinuous Galerkin (DG) and the Spectral Volume (SV) methods, but while these methods are based on the integrated forms of the equations, the new method is based on the differential form to attain a simpler formulation and higher efficiency. Conventional unstructured finite-difference and finite-volume methods require data reconstruction based on the least-squares formulation using neighboring point or cell data. Since each unknown employs a different stencil, one must repeat the least-squares inversion for every point or cell at each time step, or to store the inversion coefficients. In a high-order, three-dimensional computation, the former would involve impractically large CPU time, while for the latter the memory requirement becomes prohibitive. In addition, the finite-difference method does not satisfy the integral conservation in general. By contrast, the DG and SV methods employ a local, universal reconstruction of a given order of accuracy in each cell in terms of internally defined conservative unknowns. Since the solution is discontinuous across cell boundaries, a Riemann solver is necessary to evaluate boundary flux terms and maintain conservation. In the DG method, a Galerkin finite-element method is employed to update the nodal unknowns within each cell. This requires the inversion of a mass matrix, and the use of quadratures of twice the order of accuracy of the reconstruction to evaluate the surface integrals and additional volume integrals for nonlinear flux functions. In the SV method, the integral conservation law is used to update volume averages over subcells defined by a geometrically similar partition of each grid cell. As the order of accuracy increases, the partitioning for 3D requires the introduction of a large number of parameters, whose optimization to achieve convergence becomes increasingly more difficult. Also, the number of interior facets required to subdivide non-planar faces, and the additional increase in the number of quadrature points for each facet, increases the computational cost greatly.

Liu, Yen↗

Use of scan overlap redundancy to enhance multispectral aircraft scanner data

Two criteria were suggested for optimizing the resolution error versus signal-to-noise-ratio tradeoff. The first criterion uses equal weighting coefficients and chooses n, the number of lines averaged, so as to make the average resolution error equal to the noise error. The second criterion adjusts both the number and relative sizes of the weighting coefficients so as to minimize the total error (resolution error plus noise error). The optimum set of coefficients depends upon the geometry of the resolution element, the number of redundant scan lines, the scan line increment, and the original signal-to-noise ratio of the channel. Programs were developed to find the optimum number and relative weights of the averaging coefficients. A working definition of signal-to-noise ratio was given and used to try line averaging on a typical set of data. Line averaging was evaluated only with respect to its effect on classification accuracy.

Lindenlaub, J. C.↗

One-way Doppler extractor

This paper presents a feasibility analysis, tradeoffs, and implementation for a one-way Doppler extractor system. A Doppler error analysis is discussed which shows that quantization error is a primary source of Doppler measurement error. Several competing extraction techniques are compared, and a 'Vernier' technique is presented which obtains high Doppler resolution with low-speed logic. Parameter tradeoffs and sensitivities for this Vernier technique are discussed, leading to a hardware design configuration. Also presented is a performance evaluation of the resulting breadboard model that verifies the theoretical performance predictions. The breadboard model contains the circuitry to interface with an S-band transponder, to extract the Doppler and time-interval counts, to compute navigational parameters by means of a microprocessor, and to display the results. Performance tests have verified that the breadboard is capable of extracting Doppler, on an S-band signal, to an accuracy of better than 0.02 hertz for a one-second averaging period. This corresponds to a range rate error of no more than 3 millimeters per second.

Nossen, E. J.↗

An intercomparison of ground-based total ozone instruments

Five ground-based total ozone spectrophotometers were intercompared at Wallops Island, VA between October 1979 and January 1981. The tests were conducted to evaluate the stability and accuracy of each instrument over an extended time period. Acceptable performance regarding these two characteristics is essential if an instrument is to be useful in field measurements and network monitoring of the atmospheric total ozone content. The Dobson spectrophotometer was used as the standard of comparison for the Brewer grating spectrophotometer, the USSR M-83 ozonometer, the Canterbury filter photometer, and the SenTran filter photometer. The grating instrument was found to be potentially the equal of the Dobson but was subject to unreliable performance by its rather sophisticated electronic components. The filter photometers performed acceptably for short periods but filter aging and eventual degradation rendered both units unusable before the end of the intercomparison. Finally, the M-83 results were found to be in acceptable agreement with the Dobson throughout the period when certain qualifications are invoked. The accuracy of a single M-83 ozone measurement may be low. Averages tend to improve its agreement with the Dobson.

Parsons, C. L.↗

Improving the Effectiveness of Integral Property Calculation in a CSG Solid Modeling System by Exploiting Predictability

Integral property calculation is an important application for solid modeling systems. Algorithms for computing integral properties for various solid representation schemes are fairly well known. It is important to deigners and users of solid modeling systems to understand the behavior of such algorithms. Specifically the trade-off between execution time and accuracy is critical to effective use of integral property calculation. The average behavior of two algorithms for Constructive Solid Geometry (CSG) representations is investigated. Experimental results from the PADL-2 solid modeling system show that coarse decompositions can be used to predict execution time and error estimates for finer decompositions. Exploiting this predictability allow effective use of the algorithms in a solid modeling system.

Clark, A. L.↗

El Nino and outgoing longwave radiation - Observations from Nimbus-7 ERB

Nimbus-7 longwave radiation data are analyzed with respect to temporal and spatial changes in the anomalies induced by the El Nino event of 1982-1983. The components and functions of the earth radiation budget (ERB) instruments, which record satellite-altitude irradiances, are described. Local-noon analyses of outgoing longwave radiation (OLR) are presented; interannual variability is observed. El Nino-induced perturbations in the planetary-scale fields which affect OLR are studied. The onset, intensification, expansion, and decay of the OLR associated with El Nino are examined. A comparison of the ERS data with a three month average OLR anomaly map reveals that the ERS data have sufficient accuracy and stability with which to observe OLR anomalies induced by El Nino.

Ardanuy, P. E.↗

Transient natural convection heat and mass transfer in crystal growth

A numerical analysis of transient combined heat and mass transfer across a rectangular cavity is performed by a numerical method based on the SIMPLE algorithm. The physical parameters are selected to represent a range of possible crystal growth in solutions. Numerical results are compared with available experimental data to confirm the accuracy of the results. Good qualitative agreements are obtained for the average mass transfer rate across the cavity. Also, qualitative agreements are observed for the global development of thermal and solute fields. It is found that the thermal and solute fields become highly oscillatory when the thermal and solute Grashof numbers are large. Oscillations are probably caused by a number of different instability mechanisms. By reducing the gravity some of these instabilities were made to disappear at the lower Grashof numbers. Transient temperature and solute distribution near the crystal growing surface are highly non-uniform at the higher Grashof numbers. These non-uniformities are less severe in the reduced gravity environments but still exist. The effects of convection on the rate of average mass transfer are more than one order of magnitude higher than those of conduction in the range of Grashof numbers studied. Dependency of mass transfer rate on the Grashof number indicates that the convection effects many not be negligible even in the microgravity environments for the range of parameters investigated.

Han, Samuel S.↗

Sensitivity of mesoscale-model forecast skill to some initial-data characteristics, data density, data position, analysis procedure and measurement error

The effects of horizontal and vertical data resolution, data density, data location, different objective analysis algorithms, and measurement error on mesoscale-forecast accuracy are studied with observing-system simulation experiments. Domain-averaged errors are shown to generally decrease with time. It is found that the vertical distribution of error growth depends on the initial vertical distribution of the error itself. Larger gravity-inertia wave noise is produced in forecasts with coarser vertical data resolution. The use of a low vertical resolution observing system with three data levels leads to more forecast errors than moderate and high vertical resolution observing systems with 8 and 14 data levels. Also, with poor vertical resolution in soundings, the initial and forecast errors are not affected by the horizontal data resolution.

Warner, Thomas T.↗

Determination of Flame Temperatures from 2000 to 3000 K by Microwave Absorption

Equations are derived for the measurement of flame temperatures from the attenuation of a microwave beam by temperature-induced free electrons from chemical elements introduced in the flame. Corrections are developed to account for the electron distribution in the flame. Procedure for obtaining the temperature from absorption is outlined. The free electron collision frequency and an effective ionization potential for four alkali elements were determined experimentally. The data were taken on a gas burner with a temperature range from 1900deg to 2400deg K. The effective ionization potential of sodium agrees with the spectral-line limit value. From these experimental ionization potentials and the experimental collision frequency, an accuracy of +/-600 K in the temperature was obtained. Fluctuating and average temperature data of a liquid propellant burner are presented primarily from 1.25-centimeter-wavelength microwave measurements in comparison with simultaneous two-color pyrometer and sound intensity measurements in the region from 2200deg to 2900deg K.

Kuhns, Perry W↗

Miyun 232 MHz survey 1: Fields centered at: alpha:00(h)41(m), delta:41 deg 12 min and alpha: 07(h)00(m),delta:35 deg 00 min

A new meter-wave survey of sky region north of declination +30 deg is carried out with the Miyun 232 MHz Synthesis Radio Telescope (MSRT). The instrument, observation, and method of data reduction are briefly described. A preliminary catalog, first of a series, for two 8 deg. x 8 deg. regions centered respectively at 35 deg. is presented. On the average 4 - 5 sources per square degree are recorded with position accuracy of 5 sec. / S(Jy). BGPW scale is adopted for the flux density calibration. The accuracy of flux determination is limited by background fluctuation which is about 30 mJy. The catalog is complete for sources with flux larger than 0.25 Jy. The total number of sources listed in the paper amounts to 687. Several extended sources, sources with convex spectra, and one GPS source were found. Spectra of sources with flux larger than 0.5 Jy were also given.

Zhang, Xiz-Hen↗

Large eddy simulation of a boundary layer with concave streamwise curvature

One of the most exciting recent developments in the field of large eddy simulation (LES) is the dynamic subgrid-scale model. The dynamic model concept is a general procedure for evaluating model constants by sampling a band of the smallest scales actually resolved in the simulation. To date, the procedure has been used primarily in conjunction with the Smagorinsky model. The dynamic procedure has the advantage that the value of the model constant need not be specified a priori, but rather is calculated as a function of space and time as the simulation progresses. This feature makes the dynamic model especially attractive for flows in complex geometries where it is difficult or impossible to calibrate model constants. The dynamic model was highly successful in benchmark tests involving homogeneous and channel flows. Having demonstrated the potential of the dynamic model in these simple flows, the overall direction of the LES effort at CTR shifted toward an evaluation of the model in more complex situations. The current test cases are basic engineering-type flows for which Reynolds averaged approaches were unable to model the turbulence to within engineering accuracy. Flows currently under investigation include a backward-facing step, wake behind a circular cylinder, airfoil at high angles of attack, separated flow in a diffuser, and boundary layer over a concave surface. Preliminary results from the backward-facing step and cylinder wake simulations are encouraging. Progress on the LES of a boundary layer on a concave surface is discussed. Although the geometry of a concave wall is not very complex, the boundary layer that develops on its surface is difficult to model due to the presence of streamwise Taylor-Gortler vortices. These vortices arise as a result of a centrifugal instability associated with the convex curvature.

Lund, Thomas S.↗

Ensemble Forecasting of Coronal Mass Ejections Using the WSA-ENLIL with CONED Model

The combination of the Wang-Sheeley-Arge (WSA) coronal model, ENLIL heliospherical model version 2.7, and CONED Model version 1.3 (WSA-ENLIL with CONED Model) was employed to form ensemble forecasts for 15 halo coronal mass ejections (halo CMEs). The input parameter distributions were formed from 100 sets of CME cone parameters derived from the CONED Model. The CONED Model used image processing along with the bootstrap approach to automatically calculate cone parameter distributions from SOHO/LASCO imagery based on techniques described by Pulkkinen et al. (2010). The input parameter distributions were used as input to WSA-ENLIL to calculate the temporal evolution of the CMEs, which were analyzed to determine the propagation times to the L1 Lagrangian point and the maximum Kp indices due to the impact of the CMEs on the Earth's magnetosphere. The Newell et al. (2007) Kp index formula was employed to calculate the maximum Kp indices based on the predicted solar wind parameters near Earth assuming two magnetic field orientations: a completely southward magnetic field and a uniformly distributed clock-angle in the Newell et al. (2007) Kp index formula. The forecasts for 5 of the 15 events had accuracy such that the actual propagation time was within the ensemble average plus or minus one standard deviation. Using the completely southward magnetic field assumption, 10 of the 15 events contained the actual maximum Kp index within the range of the ensemble forecast, compared to 9 of the 15 events when using a uniformly distributed clock angle.

coronal mass↗

Multimodel Ensembles of Wheat Growth: Many Models are Better than One

Crop models of crop growth are increasingly used to quantify the impact of global changes due to climate or crop management. Therefore, accuracy of simulation results is a major concern. Studies with ensembles of crop model scan give valuable information about model accuracy and uncertainty, but such studies are difficult to organize and have only recently begun. We report on the largest ensemble study to date, of 27 wheat models tested in four contrasting locations for their accuracy in simulating multiple crop growth and yield variables. The relative error averaged over models was 2438 for the different end-of-season variables including grain yield (GY) and grain protein concentration (GPC). There was little relation between error of a model for GY or GPC and error for in-season variables. Thus, most models did not arrive at accurate simulations of GY and GPC by accurately simulating preceding growth dynamics. Ensemble simulations, taking either the mean (e-mean) or median (e-median) of simulated values, gave better estimates than any individual model when all variables were considered. Compared to individual models, e-median ranked first in simulating measured GY and third in GPC. The error of e-mean and e-median declined with an increasing number of ensemble members, with little decrease beyond 10 models. We conclude that multimodel ensembles can be used to create new estimators with improved accuracy and consistency in simulating growth dynamics. We argue that these results are applicable to other crop species, and hypothesize that they apply more generally to ecological system models.

model intercomparison↗

Multimodel Ensembles of Wheat Growth: More Models are Better than One

Crop models of crop growth are increasingly used to quantify the impact of global changes due to climate or crop management. Therefore, accuracy of simulation results is a major concern. Studies with ensembles of crop models can give valuable information about model accuracy and uncertainty, but such studies are difficult to organize and have only recently begun. We report on the largest ensemble study to date, of 27 wheat models tested in four contrasting locations for their accuracy in simulating multiple crop growth and yield variables. The relative error averaged over models was 24-38% for the different end-of-season variables including grain yield (GY) and grain protein concentration (GPC). There was little relation between error of a model for GY or GPC and error for in-season variables. Thus, most models did not arrive at accurate simulations of GY and GPC by accurately simulating preceding growth dynamics. Ensemble simulations, taking either the mean (e-mean) or median (e-median) of simulated values, gave better estimates than any individual model when all variables were considered. Compared to individual models, e-median ranked first in simulating measured GY and third in GPC. The error of e-mean and e-median declined with an increasing number of ensemble members, with little decrease beyond 10 models. We conclude that multimodel ensembles can be used to create new estimators with improved accuracy and consistency in simulating growth dynamics. We argue that these results are applicable to other crop species, and hypothesize that they apply more generally to ecological system models.

wheat↗

Uniformly high order accurate essentially non-oscillatory schemes 3

In this paper (a third in a series) the construction and the analysis of essentially non-oscillatory shock capturing methods for the approximation of hyperbolic conservation laws are presented. Also presented is a hierarchy of high order accurate schemes which generalizes Godunov's scheme and its second order accurate MUSCL extension to arbitrary order of accuracy. The design involves an essentially non-oscillatory piecewise polynomial reconstruction of the solution from its cell averages, time evolution through an approximate solution of the resulting initial value problem, and averaging of this approximate solution over each cell. The reconstruction algorithm is derived from a new interpolation technique that when applied to piecewise smooth data gives high-order accuracy whenever the function is smooth but avoids a Gibbs phenomenon at discontinuities. Unlike standard finite difference methods this procedure uses an adaptive stencil of grid points and consequently the resulting schemes are highly nonlinear.

Harten, A.↗

The effect of sensor sheltering and averaging techniques on wind measurements at the Shuttle Landing Facility

This document presents results of a field study of the effect of sheltering of wind sensors by nearby foliage on the validity of wind measurements at the Space Shuttle Landing Facility (SLF). Standard measurements are made at one second intervals from 30-feet (9.1-m) towers located 500 feet (152 m) from the SLF centerline. The centerline winds are not exactly the same as those measured by the towers. A companion study, Merceret (1995), quantifies the differences as a function of statistics of the observed winds and distance between the measurements and points of interest. This work examines the effect of nearby foliage on the accuracy of the measurements made by any one sensor, and the effects of averaging on interpretation of the measurements. The field program used logarithmically spaced portable wind towers to measure wind speed and direction over a range of conditions as a function of distance from the obstructing foliage. Appropriate statistics were computed. The results suggest that accurate measurements require foliage be cut back to OFCM standards. Analysis of averaging techniques showed that there is no significant difference between vector and scalar averages. Longer averaging periods reduce measurement error but do not otherwise change the measurement in reasonably steady flow regimes. In rapidly changing conditions, shorter averaging periods may be required to capture trends.

Merceret, Francis J.↗

Calculations of multiple scattering-induced errors in the GLAS mission

The Geoscience Lidar Altimeter System (GLAS) is a laser altimeter designed to measure temporal changes in the topography and mass balance of the Earth's ice sheets. GLAS is scheduled to be launched as part of the Earth Observing System (EOS) in 2001. Due to the large pulse width of GLAS and the slope (and roughness) of the ice sheets, the mean elevation of the laser's surface spot will be estimated from the centroid of the return pulse. While the accuracy of individual altimetry measurements is expected to be 15 cm, a cross-over technique that averages the elevation differences at selected points on the ice sheets will allow GLAS to detect mean ice elevation changes as small as 2 cm per year. One factor that may degrade the proposed accuracy of the altimeter measurements is the effect of multiple scattering by thin clouds and aerosols over the ice sheets. In the return pulse, some photons from the lidar are slightly deflected by cloud particles but still return to the instrument detector. Since these photons travel a longer path than photons that pass directly to and from the surface, the mean travel time of the pulse is lengthened and the centroid of the return pulse is shifted toward a later time . This study intends to determine the importance of this source of altimetry error in the GLAS measurements. Two methods will be used to estimate path delays in the GLAS lidar for a range of cloud conditions. An analytic expression of a doubly scattered return signal (Eloranta, 1972) will be compared to Monte Carlo simulations that estimate path delays by cloud, aerosol and molecular scattering. The results from both methods will be discussed in relationship to current knowledge of Arctic cloud climatology, and the impact of multiple scattering on GLAS altimeter measurements will be evaluated.

Duda, David P.↗

Construction and Use of Resting 12-Lead High Fidelity ECG "SuperScores" in Screening for Heart Disease

We investigated the accuracy of several conventional and advanced resting ECG parameters for identifying obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. Multiple conventional and advanced ECG parameters were studied for their individual and combined retrospective accuracies in detecting underlying disease, the advanced parameters falling within the following categories: 1) Signal averaged ECG, including 12-lead high frequency QRS (150-250 Hz) plus multiple filtered and unfiltered parameters from the derived Frank leads; 2) 12-lead P, QRS and T-wave morphology via singular value decomposition (SVD) plus signal averaging; 3) Multichannel (12-lead, derived Frank lead, SVD lead) beat-to-beat QT interval variability; 4) Spatial ventricular gradient (and gradient component) variability; and 5) Heart rate variability. Several multiparameter ECG SuperScores were derivable, using stepwise and then generalized additive logistic modeling, that each had 100% retrospective accuracy in detecting underlying CM or CAD. The performance of these same SuperScores was then prospectively evaluated using a test set of another 120 individuals (40 new individuals in each of the CM, CAD and control groups, respectively). All 12-lead ECG SuperScores retrospectively generated for CM continued to perform well in prospectively identifying CM (i.e., areas under the ROC curve greater than 0.95), with one such score (containing just 4 components) maintaining 100% prospective accuracy. SuperScores retrospectively generated for CAD performed somewhat less accurately, with prospective areas under the ROC curve typically in the 0.90-0.95 range. We conclude that resting 12-lead high-fidelity ECG employing and combining the results of several advanced ECG software techniques shows great promise as a rapid and inexpensive tool for screening of heart disease.

Schlegel, T. T.↗