Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Angular Reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Identification of a paramagnetic recombination center in silicon/silicon-dioxide interface

A paramagnetic recombination center having an orthorhombic symmetry with g[110] = 2.0095(2), g[001] = 2.0038(2), and g[110] = 2.0029(2) is found at the interface between silicon and native oxide. The center is referred to P{sub m} center and observed by a spin dependent recombination based electron paramagnetic resonance detection that has the sensitivity of {approx}10{sup 11} spins/cm{sup 2}. The employment of an isotopically enriched {sup 28}Si sample with the concentration of {sup 29}Si nuclear spins reduced to 0.017% leads to narrowing of the resonance line. This narrowing is the key for the accurate determination of the angular dependence of the g-factor.

36 MATERIALS SCIENCE↗

Non-local contribution from small scales in galaxy–galaxy lensing: comparison of mitigation schemes

ABSTRACT Recent cosmological analyses with large-scale structure and weak lensing measurements, usually referred to as 3 × 2pt, had to discard a lot of signal to noise from small scales due to our inability to accurately model non-linearities and baryonic effects. Galaxy–galaxy lensing, or the position–shear correlation between lens and source galaxies, is one of the three two-point correlation functions that are included in such analyses, usually estimated with the mean tangential shear. However, tangential shear measurements at a given angular scale θ or physical scale R carry information from all scales below that, forcing the scale cuts applied in real data to be significantly larger than the scale at which theoretical uncertainties become problematic. Recently, there have been a few independent efforts that aim to mitigate the non-locality of the galaxy–galaxy lensing signal. Here, we perform a comparison of the different methods, including the Y-transformation, the point-mass marginalization methodology, and the annular differential surface density statistic. We do the comparison at the cosmological constraints level in a combined galaxy clustering and galaxy–galaxy lensing analysis. We find that all the estimators yield equivalent cosmological results assuming a simulated Rubin Observatory Legacy Survey of Space and Time (LSST) Year 1 like set-up and also when applied to DES Y3 data. With the LSST Y1 set-up, we find that the mitigation schemes yield ∼1.3 times more constraining S8 results than applying larger scale cuts without using any mitigation scheme.

79 ASTRONOMY AND ASTROPHYSICS↗

STARlight: A Monte Carlo simulation program for ultra-peripheral collisions of relativistic ions

© 2016 Elsevier B.V. Ultra-peripheral collisions (UPCs) have been a significant source of study at RHIC and the LHC. In these collisions, the two colliding nuclei interact electromagnetically, via two-photon or photonuclear interactions, but not hadronically; they effectively miss each other. Photonuclear interactions produce vector meson states or more general photonuclear final states, while two-photon interactions can produce lepton or meson pairs, or single mesons. In these interactions, the collision geometry plays a major role. We present a program, STARlight, that calculates the cross-sections for a variety of UPC final states and also creates, via Monte Carlo simulation, events for use in determining detector efficiency. Program summary Program Title: STARlight (v2.2) Program Files doi: http://dx.doi.org/10.17632/xjpf4rxtbj.1 Licensing provisions: GNU GPLv3 Programming Language: C++ External Routines: PYTHIA 8.2 and DPMJET 3.0 are needed for some final states. Nature of problem: The cross-section for ultra-peripheral collisions is obtained by integrating the photon fluxes in transverse impact parameter space, subject to the requirement (which is also impact parameter dependent) that the colliding nuclei do not interact hadronically. The program is a two step process. First, it calculates the cross-sections for the reaction of interest, as a function of W (photon–Pomeron or two-photon center of mass energy), Y (final state rapidity) and pT (final state transverse momentum). Second, STARlight generates Monte Carlo events which can be used to determine cross-sections within specific kinematic constraints or for studies of detector efficiencies. The second step includes the decay of any unstable particles produced in the reaction, with appropriate consideration of particle spins and parity. It outputs these events in ASCII format. Solution method: The program generates a two dimensional look-up table of the production cross-section as a function of final state rapidity and mass. The dimensions of the table are selectable, allowing the user to choose the desired accuracy. For certain final states, a second two-dimensional look-up table, giving the transverse momentum distribution, as a function of rapidity, is also used. With these look-up tables, the program generates final states. Particle decays and the final angular distributions are calculated for each event. Restrictions: The program is focused on ultra-relativistic collisions at Brookhaven's RHIC (Relativistic Heavy Ion Collider) and CERN's LHC (Large Hadron Collider), with final states that are visible in a central detector. At lower energies (i.e., at the CERN SPS), caution should be exercised because STARlight does not account for the longitudinal momentum transfer to the nucleus; this is larger at low beam energies. References: http://starlight.hepforge.org and references in this article.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compilation and Evaluation of Isomeric Fission Yield Ratios

Fission yields are essential data for reactor physics, forensics, and astrophysics. In some cases, the fission yield of a fragment is divided between the ground state and a long-lived excited state, and the relative population of the two states is referred to as the isomeric ratio. In this work, we present a comprehensive compilation of experimental isomeric fission yield ratios for all target and projectile combinations. When possible, these data are combined to provide recommended isomeric fission yield ratios for low energy neutron-induced fission and spontaneous fission. The recommended ratios are compared to the traditional Madland-England model, which attempts to describe the isomeric ratios with a single parameter relating to the angular momentum of the fragment. It is found that the model does not reliably reproduce isomeric ratios outside the few nuclei it was fitted to, and its simplified treatment of the statistical process following population in fission results in average spin values, which are neither constant nor follow a recently observed saw-tooth pattern.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

hsrl (01)

High-spectral-resolution lidar (HSRL) systems collect data about clouds and aerosols. These systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are absolutely calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar, but unlike simple backscatter lidars such as the micropulse lidar, the HSRL can measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations also allow robust discrimination between ice and water clouds. In addition, rigorous error estimates can be computed for all measurements. A very narrow, angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. ARM operates two HSRL systems, one at the Barrow, North Slope of Alaska (NSA) site and the other in the second ARM Mobile Facility (AMF2), which is deployed at various locations on field campaigns.

54 ENVIRONMENTAL SCIENCES↗

hsrl (00)

High-spectral-resolution lidar (HSRL) systems collect data about clouds and aerosols. These systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are absolutely calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar, but unlike simple backscatter lidars such as the micropulse lidar, the HSRL can measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations also allow robust discrimination between ice and water clouds. In addition, rigorous error estimates can be computed for all measurements. A very narrow, angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. ARM operates two HSRL systems, one at the Barrow, North Slope of Alaska (NSA) site and the other in the second ARM Mobile Facility (AMF2), which is deployed at various locations on field campaigns.

54 ENVIRONMENTAL SCIENCES↗

Measuring the speed of light with ultra-compact radio quasars

In this paper, based on a 2.29 GHz VLBI all-sky survey of 613 milliarcsecond ultra-compact radio sources with 0.0035< z <3.787, we describe a method of identifying the sub-sample which can serve as individual standard rulers in cosmology. If the linear size of the compact structure is assumed to depend on source luminosity and redshift as l {sub m} = l L {sup β} (1+ z ) {sup n} , only intermediate-luminosity quasars (10{sup 27} W/Hz< L < 10{sup 28} W/Hz) show negligible dependence (| n |≅ 10{sup −3}, |β|≅ 10{sup −4}), and thus represent a population of such rulers with fixed characteristic length l =11.42 pc. With a sample of 120 such sources covering the redshift range 00.46< z <2.8, we confirm the existence of dark energy in the Universe with high significance under the assumption of a flat universe, and obtain stringent constraints on both the matter density Ω {sub m} =0.323{sup +0.245}{sub −0.145} and the Hubble constant H {sub 0}=66.30{sup +7.00}{sub −8.50} km sec{sup −1} Mpc{sup −1}. Finally, with the angular diameter distances D {sub A} measured for quasars extending to high redshifts (0 z ∼ 3.), we reconstruct the D {sub A} ( z ) function using the technique of Gaussian processes. This allows us to identify the redshift corresponding to the maximum of the D {sub A} ( z ) function: 0 z {sub m} =1.7 and the corresponding angular diameter distance D {sub A} ( z {sub m} )=1719.01±43.46 Mpc. Similar reconstruction of the expansion rate function H ( z ) based on the data from cosmic chronometers and BAO gives us H ( z {sub m} )=176.77±6.11 km sec{sup −1} Mpc{sup −1}. These measurements are used to estimate the speed of light: c =3.039(±0.180)× 10{sup 5} km/s. This is the first measurement of the speed of light in a cosmological setting referring to the distant past.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES↗

The Whole is Greater than the Sum of the Parts: Optimizing the Joint Science Return from LSST, Euclid and WFIRST

The scientific opportunity offered by the combination of data from LSST, WFIRST and Euclid goes well beyond the science enabled by any one of the data sets alone. The range in wavelength, angular resolution and redshift coverage that these missions jointly span is remarkable. With major investments in LSST and WFIRST, and partnership with ESA in Euclid, the US has an outstanding scientific opportunity to carry out a combined analysis of these data sets. It is imperative for us to seize it and, together with our European colleagues, prepare for the defining cosmological pursuit of the 21st century. The main argument for conducting a single, high-quality reference co-analysis exercise and carefully documenting the results is the complexity and subtlety of systematics that define this co-analysis. Falling back on many small efforts by different teams in selected fields and for narrow goals will be inefficient, leading to significant duplication of effort.

Jain, B.↗

Small-angle scattering interferometry with neutron orbital angular momentum states

Methods to prepare and characterize neutron helical waves carrying orbital angular momentum (OAM) were recently demonstrated at small-angle neutron scattering (SANS) facilities. These methods enable access to the neutron orbital degree of freedom which provides new avenues of exploration in fundamental science experiments as well as in material characterization applications. However, it remains a challenge to recover phase profiles from SANS measurements. We introduce and demonstrate a novel neutron interferometry technique for extracting phase information that is typically lost in SANS measurements. An array of reference beams, with complementary structured phase profiles, are put into a coherent superposition with the array of object beams, thereby manifesting the phase information in the far-field intensity profile. We demonstrate this by resolving petal-structure signatures of helical wave interference for the first time: an implementation of the long-sought recovery of phase information from small-angle scattering measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent spin dynamics in nanopatterned ferromagnet-semiconductor hybrids at room-temperature

We used time-resolved Kerr rotation to study the coherent spin dynamics of electrons in Py-GaAs hybrid structures up to room temperature. The geometry of the nanopatterned Py wires was varied in a wide range to modify the fringe field from the ferromagnets and thus the Larmor frequency of the precessing electron spins compared to a reference. At room temperature, the observed fringe field effect is in good agreement with theory while at low temperatures additional strain effects occur.

36 MATERIALS SCIENCE↗

Mass measurements in the vicinity of the doubly magic waiting point {sup 56}Ni

Masses of {sup 56,57}Fe, {sup 53}Co{sup m}, {sup 53,56}Co, {sup 55,56,57}Ni, {sup 57,58}Cu, and {sup 59,60}Zn have been determined with the JYFLTRAP Penning trap mass spectrometer at the Ion-Guide Isotope Separator On-Line facility with a precision of {delta}m/m{<=}3x10{sup -8}. The Q{sub EC} values for {sup 53}Co, {sup 55}Ni, {sup 56}Ni, {sup 57}Cu, {sup 58}Cu, and {sup 59}Zn have been measured directly with a typical precision of better than 0.7 keV and Coulomb displacement energies have been determined. The Q values for proton captures on {sup 55}Co, {sup 56}Ni, {sup 58}Cu, and {sup 59}Cu have been measured directly. The precision of the proton-capture Q value for {sup 56}Ni(p,{gamma}){sup 57}Cu, Q{sub (p,{gamma})}=689.69(51) keV, crucial for astrophysical rp-process calculations, has been improved by a factor of 37. The excitation energy of the proton-emitting spin-gap isomer {sup 53}Co{sup m} has been measured precisely, E{sub x}=3 174.3(10) keV, and a Coulomb energy difference of 133.9(10) keV for the 19/2{sup -} state has been obtained. Except for {sup 53}Co, the mass values have been adjusted within a network of 17 frequency ratio measurements between 13 nuclides, which allowed also a determination of the reference masses {sup 55}Co, {sup 58}Ni, and {sup 59}Cu.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlation between the spin-independent and spin-dependent direct detection of dark matter

We study the correlation between spin-independent and spin-dependent scattering in the context of minimal supersymmetric standard model neutralino dark matter for both thermal and nonthermal histories. We explore the generality of this relationship with reference to other models. We discuss why either fine-tuning or numerical coincidences are necessary for the correlation to break down. We derive upper bounds on spin-dependent scattering mediated by a Z{sup 0} boson.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Feasibility of vibro-acoustography with a quasi-2D ultrasound array transducer for detection and localizing of permanent prostate brachytherapy seeds: A pilot ex vivo study

Purpose: Effective permanent prostate brachytherapy (PPB) requires precise placement of radioactive seeds in and around the prostate. The impetus for this research is to examine a new ultrasound-based imaging modality, vibro-acoustography (VA), which may serve to provide a high rate of PPB seed detection while also effecting enhanced prostate imaging. The authors investigate the ability of VA, implemented on a clinical ultrasound (US) scanner and equipped with a quasi-2D (Q2D) array US transducer, to detect and localize PPB seeds in excised prostate specimens. Methods: Nonradioactive brachytherapy seeds were implanted into four excised cadaver prostates. A clinical US scanner equipped with a Q2D array US transducer was customized to acquire both US and C-scan VA images at various depths. The VA images were then used to detect and localize the implanted seeds in prostate tissue. To validate the VA results, computed tomography (CT) images of the same tissue samples were obtained to serve as the reference by which to evaluate the performance of VA in PPB seed detection. Results: The results indicate that VA is capable of accurately identifying the presence and distribution of PPB seeds with a high imaging contrast. Moreover, a large ratio of the PPB seeds implanted into prostate tissue samples could be detected through acquired VA images. Using CT-based seed identification as the standard, VA was capable of detecting 74%–92% of the implanted seeds. Additionally, the angular independency of VA in detecting PPB seeds was demonstrated through a well-controlled phantom experiment. Conclusions: Q2DVA detected a substantial portion of the seeds by using a 2D array US transducer in excised prostate tissue specimens. While VA has inherent advantages associated with conventional US imaging, it has the additional advantage of permitting detection of PPB seeds independent of their orientation. These results suggest the potential of VA as a method for PPB imaging that ultimately may allow US-based real-time intraoperative dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Angular dependence of the response of the nanoDot OSLD system for measurements at depth in clinical megavoltage beams

Purpose: The purpose of this investigation was to assess the angular dependence of a commercial optically stimulated luminescence dosimeter (OSLD) dosimetry system in MV x-ray beams at depths beyondd{sub max} and to find ways to mitigate this dependence for measurements in phantoms. Methods: Two special holders were designed which allow a dosimeter to be rotated around the center of its sensitive volume. The dosimeter's sensitive volume is a disk, 5 mm in diameter and 0.2 mm thick. The first holder rotates the disk in the traditional way. It positions the disk perpendicular to the beam (gantry pointing to the floor) in the initial position (0°). When the holder is rotated the angle of the disk towards the beam increases until the disk is parallel with the beam (“edge on,” 90°). This is referred to as Setup 1. The second holder offers a new, alternative measurement position. It positions the disk parallel to the beam for all angles while rotating around its center (Setup 2). Measurements with five to ten dosimeters per point were carried out for 6 MV at 3 and 10 cm depth. Monte Carlo simulations using GEANT4 were performed to simulate the response of the active detector material for several angles. Detector and housing were simulated in detail based on microCT data and communications with the manufacturer. Various material compositions and an all-water geometry were considered. Results: For the traditional Setup 1 the response of the OSLD dropped on average by 1.4% ± 0.7% (measurement) and 2.1% ± 0.3% (Monte Carlo simulation) for the 90° orientation compared to 0°. Monte Carlo simulations also showed a strong dependence of the effect on the composition of the sensitive layer. Assuming the layer to completely consist of the active material (Al{sub 2}O{sub 3}) results in a 7% drop in response for 90° compared to 0°. Assuming the layer to be completely water, results in a flat response within the simulation uncertainty of about 1%. For the new Setup 2, measurements and Monte Carlo simulations found the angular dependence of the dosimeter to be below 1% and within the measurement uncertainty. Conclusions: The dosimeter system exhibits a small angular dependence of approximately 2% which needs to be considered for measurements involving other than normal incident beams angles. This applies in particular to clinicalin vivo measurements where the orientation of the dosimeter is dictated by clinical circumstances and cannot be optimized as otherwise suggested here. When measuring in a phantom, the proposed new setup should be considered. It changes the orientation of the dosimeter so that a coplanar beam arrangement always hits the disk shaped detector material from the thin side and thereby reduces the angular dependence of the response to within the measurement uncertainty of about 1%. This improvement makes the dosimeter more attractive for clinical measurements with multiple coplanar beams in phantoms, as the overall measurement uncertainty is reduced. Similarly, phantom based postal audits can transition from the traditional TLD to the more accurate and convenient OSLD.

61 RADIATION PROTECTION AND DOSIMETRY↗

Breakup Reactions and Exclusive Measurements in the {sup 6,7}Li+{sup 144}Sm Systems

The breakup of the projectile-like nuclei in reactions induced by 30 MeV {sup 6}Li and {sup 7}Li beams on a {sup 144}Sm target have been measured through the coincident detection of the in-plane emitted light particles. The primary ion that undergoes breakup has been identified and the physically meaningful variables that characterize the reaction have been obtained on a purely experimental basis. Distributions have been obtained for both the binary emission angle and for the breakup emission angle in the reference frame of the breakup products.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scattering amplitudes for monopoles: pairwise little group and pairwise helicity

On-shell methods are particularly suited for exploring the scattering of electrically and magnetically charged objects, for which there is no local and Lorentz invariant Lagrangian description. In this paper we show how to construct a Lorentz-invariant S-matrix for the scattering of electrically and magnetically charged particles, without ever having to refer to a Dirac string. A key ingredient is a revision of our fundamental understanding of multi-particle representations of the Poincaré group. Surprisingly, the asymptotic states for electric-magnetic scattering transform with an additional little group phase, associated with pairs of electrically and magnetically charged particles. The corresponding “pairwise helicity” is identified with the quantized “cross product” of charges, e 1 g 2 - e 2 g 1 , for every charge-monopole pair, and represents the extra angular momentum stored in the asymptotic electromagnetic field. We define a new kind of pairwise spinor-helicity variable, which serves as an additional building block for electric-magnetic scattering amplitudes. We then construct the most general 3-point S-matrix elements, as well as the full partial wave decomposition for the 2 → 2 fermion-monopole S-matrix. In particular, we derive the famous helicity flip in the lowest partial wave as a simple consequence of a generalized spin-helicity selection rule, as well as the full angular dependence for the higher partial waves. Our construction provides a significant new achievement for the on-shell program, succeeding where the Lagrangian description has so far failed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging

Purpose: To achieve high temporal resolution in CT myocardial perfusion imaging (MPI), images are often reconstructed using filtered backprojection (FBP) algorithms from data acquired within a short-scan angular range. However, the variation in the central angle from one time frame to the next in gated short scans has been shown to create detrimental partial scan artifacts when performing quantitative MPI measurements. This study has two main purposes. (1) To demonstrate the existence of a distinct detrimental effect in short-scan FBP, i.e., the introduction of a nonuniform spatial image noise distribution; this nonuniformity can lead to unexpectedly high image noise and streaking artifacts, which may affect CT MPI quantification. (2) To demonstrate that statistical image reconstruction (SIR) algorithms can be a potential solution to address the nonuniform spatial noise distribution problem and can also lead to radiation dose reduction in the context of CT MPI. Methods: Projection datasets from a numerically simulated perfusion phantom and an in vivo animal myocardial perfusion CT scan were used in this study. In the numerical phantom, multiple realizations of Poisson noise were added to projection data at each time frame to investigate the spatial distribution of noise. Images from all datasets were reconstructed using both FBP and SIR reconstruction algorithms. To quantify the spatial distribution of noise, the mean and standard deviation were measured in several regions of interest (ROIs) and analyzed across time frames. In the in vivo study, two low-dose scans at tube currents of 25 and 50 mA were reconstructed using FBP and SIR. Quantitative perfusion metrics, namely, the normalized upslope (NUS), myocardial blood volume (MBV), and first moment transit time (FMT), were measured for two ROIs and compared to reference values obtained from a high-dose scan performed at 500 mA. Results: Images reconstructed using FBP showed a highly nonuniform spatial distribution of noise. This spatial nonuniformity led to large fluctuations in the temporal direction. In the numerical phantom study, the level of noise was shown to vary by as much as 87% within a given image, and as much as 110% between different time frames for a ROI far from isocenter. The spatially nonuniform noise pattern was shown to correlate with the source trajectory and the object structure. In contrast, images reconstructed using SIR showed a highly uniform spatial distribution of noise, leading to smaller unexpected noise fluctuations in the temporal direction when a short scan angular range was used. In the numerical phantom study, the noise varied by less than 37% within a given image, and by less than 20% between different time frames. Also, the noise standard deviation in SIR images was on average half of that of FBP images. In the in vivo studies, the deviation observed between quantitative perfusion metrics measured from low-dose scans and high-dose scans was mitigated when SIR was used instead of FBP to reconstruct images. Conclusions: (1) Images reconstructed using FBP suffered from nonuniform spatial noise levels. This nonuniformity is another manifestation of the detrimental effects caused by short-scan reconstruction in CT MPI. (2) Images reconstructed using SIR had a much lower and more uniform noise level and thus can be used as a potential solution to address the FBP nonuniformity. (3) Given the improvement in the accuracy of the perfusion metrics when using SIR, it may be desirable to use a statistical reconstruction framework to perform low-dose dynamic CT MPI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗