SIT Makeup Effect on the Loss of Residual Heat Removal during Mid-loop Operation

For the loss of cooling during the mid-loop operation, the plant needs to have a sufficient time for operator action without active makeup measures such as a loss of alternating current (AC) power. This concern is raised after the Fukushima accident. Especially, in addition to the loss of residual heat removal (LORHR), if the AC power or active makeup measures are unavailable, the passive makeup using gravity feed or pressurized feed will provide sufficient time before core uncovery. This paper investigates means of the passive makeup measures using safety injection tank (SIT) after the LORHR event to prevent or delay the core uncovery and fuel failure for the typical advanced power reactor 1400 (APR1400). Unfortunately, the refueling water storage tank of APR1400 cannot be used for gravity makeup since it is located on the bottom of the containment with a lower elevation than the reactor vessel. So, the SIT makeup and the effect on the core uncovery are investigated. The results show that gravity makeup of a SIT provides insufficient means but the slightly pressurized SIT is required for sufficient operator action time for the LORHR with the station black out (SBO) during the mid-loop operation for the APR1400. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Transmission characteristics of microwave in a glow-discharge dusty plasma

In this study, the propagation characteristics of electromagnetic wave in a glow discharge plasma with dust particles are experimentally investigated. A helium alternating current glow discharge plasmas have been successfully generated. Measurements of the plasma parameters using Langmuir probes, in the absence of dust particles, provide plasma densities (n{sub e}) of 10{sup 17 }m{sup −3} and electron temperatures (T{sub e}) ranging from 2 to 4 eV. Dusty plasmas are made by adding 30 nm radius aluminum oxide (Al{sub 2}O{sub 3}) particles into the helium plasma. The density of the dust particle (n{sub d}) in the device is about 10{sup 11}–10{sup 12 }m{sup −3}. The propagation characteristics of electromagnetic waves are determined by a vector network analyzer with 4–6 GHz antennas. An apparent attenuation by the dust is observed, and the measured attenuation data are approximately in accordance with the theoretical calculations. The effects of gas pressure and input power on the propagation are also investigated. Results show that the transmission attenuation increases with the gas pressure and input power, the charged dust particles play a significant role in the microwave attenuation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Review of Permanent Magnet Stirring During Metal Solidification

Rather than using conventional electromagnetic stirring (EMS) with three-phase alternating current, permanent magnet stirring (PMS), based on the use of sintered NdFeB material which has excellent magnetic characteristics, can be employed to generate a magnetic field for the stirring of liquid metal during solidification. Recent experience with steel casting indicates that PMS requires less than 20 pct of the total energy compared with EMS. Despite the excellent magnetic density properties and low power consumption, this relatively new technology has received comparatively little attention by the metal casting community. This paper reviews simulation modeling, experimental studies, and industrial trials of PMS conducted during recent years. With the development of magnetic simulation software, the magnetic field and associated flow patterns generated by PMS have been evaluated. Based on the results obtained from laboratory experiments, the effects of PMS on metal solidification structures and typical defects such as surface pinholes and center cavities are summarized. The significance of findings obtained from trials of PMS within the metals processing sector, including the continuous casting of steel, are discussed with the aim of providing an overview of the relevant parameters that are of importance for further development and industrial application of this innovative technology.

36 MATERIALS SCIENCE↗

Effect of crystallization water on the structural and electrical properties of CuWO{sub 4} under high pressure

The effect of crystallization water on the structural and electrical properties of CuWO{sub 4} under high pressure has been investigated by in situ X-ray diffraction and alternating current impedance spectra measurements. The crystallization water was found to be a key role in modulating the structural stability of CuWO{sub 4} at high pressures. The anhydrous CuWO{sub 4} undergoes two pressure-induced structural transitions at 8.8 and 18.5 GPa, respectively, while CuWO{sub 4}·2H{sub 2}O keeps its original structure up to 40.5 GPa. Besides, the crystallization water makes the electrical transport behavior of anhydrous CuWO{sub 4} and CuWO{sub 4}·2H{sub 2}O quite different. The charge carrier transportation is always isotropic in CuWO{sub 4}·2H{sub 2}O, but anisotropic in the triclinic and the third phase of anhydrous CuWO{sub 4}. The grain resistance of CuWO{sub 4}·2H{sub 2}O is always larger than that of anhydrous CuWO{sub 4} in the entire pressure range. By analyzing the relaxation response, we found that the large number of hydrogen bonds can soften the grain characteristic frequency of CuWO{sub 4}·2H{sub 2}O over CuWO{sub 4} by one order of magnitude.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of AC target power on AlN film quality

The influence of alternating current (AC) target power on film stress, roughness, and x-ray diffraction rocking curve full width half maximum (FWHM) was examined for AlN films deposited using S-gun magnetron sputtering on insulative substrates consisting of Si wafers with 575 nm thermal oxide. As the AC target power was increased from 5 to 8 kW, the deposition rate increased from 9.3 to 15.9 A/s, film stress decreased from 81 to −170 MPa, and the rocking curve FWHM increased from 0.98 to 1.03°. AlN film behavior is observed to change with target life; films deposited at 200 kWh target life were approximately 40 MPa more compressive and had 0.02° degree higher rocking curve FWHM values than films deposited at 130 kWh. AlN films deposited in two depositions were compared with films deposited in a single deposition, in order to better characterize the growth behavior and properties of AlN films deposited on an existing AlN film, which is not well understood. Two deposition films, when compared with single deposition films, showed no variation in residual stress trends or grain size behavior, but the average film roughness increased from 0.7 to 1.4 nm and rocking curve FWHM values increased by more than 0.25°.

36 MATERIALS SCIENCE↗

Temporal evolution characteristics of an annular-mode gliding arc discharge in a vortex flow

An annular-mode gliding arc discharge powered by a 50 Hz alternating current (ac) supply was studied in a vortex flow of dry and humid air. Its temporal evolution characteristics were investigated by electrical measurement, temporally resolved imaging, and temporally resolved optical emission spectroscopic measurements. Three discharge stages of arc-ignition, arc-gliding, and arc-extinction were clearly observed in each half-cycle of the discharge. During the arc-gliding stage, the intensity of light emission from the arc root at the cathode was remarkably higher than that at other areas. The spectral intensity of N{sub 2}(C{sup 3}Π{sub u}−B{sup 3}Π{sub g}) during the arc-ignition stage was much higher than that during the arc-gliding stage, which was contrary to the temporal evolutions of spectral intensities for N{sub 2}{sup +}(B{sup 2}Σ{sub u}{sup +}−X{sup 2}Σ{sub g}{sup +}) and OH(A{sup 2}Σ{sup +}−X{sup 2}Π{sub i}). Temporally resolved vibrational and rotational temperatures of N{sub 2} were also presented and decreased with increasing the water vapor content.

54 ENVIRONMENTAL SCIENCES↗

Topological circuits of inductors and capacitors

Alternating current (ac) circuits can have electromagnetic edge modes protected by symmetries, analogous to topological band insulators or semimetals. How to make such a topological circuit? This paper illustrates a particular design idea by analyzing a series of topological circuits consisting purely of inductors (L) and capacitors (C) connected to each other by wires to form periodic lattices. All the examples are treated using a unifying approach based on Lagrangians and the dynamical H-matrix. First, the building blocks and permutation wiring are introduced using simple circuits in one dimension, the SSH transmission line and a braided ladder analogous to the ice-tray model also known as the π-flux ladder. Then, more general building blocks (loops and stars) and wiring schemes (m-shifts) are introduced. The key concepts of emergent pseudo-spin degrees of freedom and synthetic gauge fields are discussed, and the connection to quantum lattice Hamiltonians is clarified. A diagrammatic notation is introduced to simplify the design and presentation of more complicated circuits. These building blocks are then used to construct topological circuits in higher dimensions. The examples include the circuit analog of Haldane’s Chern insulator in two dimensions and quantum Hall insulator in four dimensions featuring finite second Chern numbers. The topological invariants and symmetry protection of the edge modes are discussed based on the H-matrix.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Systems Engineering (SE) Approach of Developing A Passive Safety Injection System (PSIS) to Cope with APR1400 Extended Station Black-Out (SBO) Accident Using RELAP5

On 11 March 2011 the power supply and cooling of the three Fukushima Daiichi reactors were disabled by a major earthquake followed by a relatively high tsunami waves. The earthquake damaged the electrical grid which is the normal power supply for the reactors, then the tsunami waves disabled the emergency diesel generators of the Fukushima Daiichi reactors, which left the plant with no alternating current (AC) source. This condition is called 'Station Black-Out'. The reactors were tripped immediately, but due to the nuclear physics phenomena, the reactor cores were still producing thermal power, which is generated by the decay of radioactive fission products in the reactor core, known as decay heat. The decay heat had not been circulated to an external heat sink and eventually the accumulative heat produced in the core led to damage to the reactor cores. After the Fukushima Daiichi accident, Design Extension Condition (DEC) such as total loss of feed water (TLOFW), and prolonged Station Black-Out (SBO) attracted the attention of nuclear experts. The attention focuses on the defense in depth concept, redundancy and sustainability of the systems, and development of the passive safety systems, which rely on natural physics laws. The topic of this paper is to discuss the possibility of attaching a Passive Safety Injection System (PSIS) to the APR1400. The PSIS is a safety system which provides adequate cooling water to the steam generators after the loss of the Auxiliary Feed Water System (AFWS) during an extended SBO accident. The PSIS will be available while the power supply of the plant is being recovered and the active safety systems take over the functionality. The anticipated PSIS will be automatically actuated to enhance the engineered safety feature and to reduce the human errors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimal Power Dispatch of DGs in Radial and Mesh AC Grids: A Hybrid Solution Methodology between the Salps Swarm Algorithm and Successive Approximation Power Flow Method

In this paper, we address the problem of the optimal power dispatch of Distributed Generators (DGs) in Alternating Current (AC) networks, better known as the Optimal Power Flow (OPF) problem. We used, as the objective function, the minimization of power losses (P loss ) associated with energy transport, which are subject to the set of constraints that compose AC networks in an environment of distributed generation. To validate the effectiveness of the proposed methodology in solving the OPF problem in any network topology, we employed one 10-node mesh test system and three radial text systems: 10, 33, and 69 nodes. In each test system, DGs were allowed to inject 20%, 40%, and 60% of the power supplied by the slack generator in the base case. To solve the OPF problem, we used a master–slave methodology that integrates the optimization method Salps Swarm Algorithm (SSA) and the load flow technique based on the Successive Approximation (SA) method. Moreover, for comparison purposes, we employed some of the algorithms reported in the specialized literature to solve the OPF problem (the continuous genetic algorithm, the particle swarm optimization algorithm, the black hole algorithm, the antlion optimization algorithm, and the Multi-Verse Optimizer algorithm), which were selected because of their excellent results in solving such problems. The results obtained by the proposed solution methodology demonstrate its superiority and convergence capacity in terms of minimization of P loss in both radial and mesh systems. It provided the best reduction in minimum P loss in short processing times and showed excellent repeatability in each test system and scenario under analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dry coupled magnetostrictive transducers for robotic inspection of dry storage casks - 15304

The lack of a national repository for used nuclear fuel has lead to the usage of dry storage casks as the de facto long term storage solution, the usage of which is prevalent throughout the United States. Furthermore, as shown in figure 3, the usage of dry storage is only expected to increase over time. Because these casks were originally intended as only an interim measure, there is an urgent need to develop methods to monitor their structural health over the long-term. Additionally, when concerns about the susceptibility of these casks to cracking is considered, the need for inspection becomes even more apparent. The use of robotic devices to inspect the interior of these casks for signs of damage has been proposed, but in order for this to be realized, advances in sensing technology must occur. We develop a novel type of transducer for non-destructive evaluation to aid in these efforts. We construct a prototype sensor, demonstrate simple defect detection with it, and present a design for an inspection robot equipping these transducers. Ultrasonic inspection is a well known method of non-destructive evaluation which works by measuring the response of ultrasonic waves propagating through a material. In through-transmission inspection, a transmitter and receiver are used to generate and detect waves in the material to be inspected. The presence of a crack or defect in the material will scatter some of the transmitted wave's energy, reducing the strength of the response at the receiver. Magnetostrictive transducers are often used to generate and detect guided waves. These transducers depend on the magnetostrictive effect, where certain materials will deform in the presence of a magnetic field. The typical construction of one of these transducers is shown in figure 5, consisting of a magnetostrictive foil, meandering coil, and a biasing magnet. Materials typically used for the foil include Fe-Co and Terfenol-D. For wave generation, a high-frequency alternating current is supplied to the coil of the transducer, which generates an oscillating magnetic field that causes the foil to deform. For reception, the inverse occurs: deformation of the foil results in a current in the coil that can be detected. The deformation of the foil is usually coupled to the material to be inspected with an adhesive, and waves are transmitted through this bond. Obviously, an inspection robot cannot have its sensors bound to the surface of the cask. A robot is being designed for inspection, and it must deal with many challenges inside the cask, including tight confines, right-angle transitions, high temperatures, and radiation. For our initial design, we consider only the geometrical constraints, and present a design for a prototype that can be assembled from COTS components. The robot needs to be articulated to navigate the bends in the cask, so each wheel is individually actuated. The robot is controlled via a tether, which also supplies electrical power and compressed air. For localization, ultrasonic range-finders and a camera are equipped. Using the basic transducer, we experimented with various configurations of materials and geometry. In order to gather relevant data, we used force sensitive resistors to measure applied force, and a Matec computer system to generate and measure ultrasonic waves. A testing rig was constructed to simulate the geometrical constraints of the interior of the cask, and we experimented using deadweights, a pneumatic cylinder, and an air bladder to apply the force. It was discovered early in the testing process that the performance of the transducer was very sensitive to the alignment of the components, and the method by which the foil was attached. To maximize performance, we designed an enclosure that would hold the components in alignment while still allowing the foil to float. To test the effectiveness of our new transducer, we cut circular holes of varying diameter in 2 mm aluminum plate, and measured the response across them. It can be seen that there is a clear relationship between the strength of the received signal and the force applied, and to a lesser extent, the size of the defect. This design performs adequately as a proof of concept, and a more precisely fabricated enclosure should further increase the accuracy of its measurements.

42 ENGINEERING↗

Solar Photovoltaics: Supply Chain Deep Dive Assessment

This is one of a series of reports and deep dive assessments produced in response to Executive Order 14017 “America’s Supply Chains,” which directs the Secretary of Energy to submit a report on supply chains for the energy sector industrial base. The Executive Order is helping the federal government to build more secure and diverse U.S. supply chains, including energy supply chains. Over the past decade, solar power has gone from an emerging, niche technology to a mature energy industry. By 2035, solar power could supply 40% or more of U.S. electricity demand, dramatically accelerating the decarbonization of buildings, transportation, and industry; and, if current technology trends continue, it could do so without increasing the price of electricity. The rapid expansion of solar energy has the potential to yield broad benefits in the form of economic activity and workforce development. The solar industry already employs roughly 230,000 people in the United States, at an average wage that is higher than the national average for most comparable positions. By decarbonizing the electricity sector by 2035, the U.S. solar industry could employ 500,000–1,500,000 people by 2030. The components that are assembled to install a photovoltaic power system are produced by a global supply chain. Photovoltaic (PV) modules (also called panels) are made of cells that use a variety of technologies. There are two leading types of solar modules used in the United States, with crystalline silicon (c-Si) modules representing 84% of the market and cadmium telluride (CdTe) modules representing 16% of the market. Modules of either type require mounting structures to provide mechanical support (racking), which may be configured to follow the sun (tracking). The output of any PV module is direct current (dc), which is almost always converted to alternating current (ac) by an inverter.

14 SOLAR ENERGY↗

Selection of Alternator Voltage for Dynamic Radioisotope Power Systems

In this paper, we present a study to select an appropriate alternator voltage of the free-piston Stirling convertors (FPSC) for efficient and light Dynamic Radioisotope Power Systems (DRPS). With a system thermal-to-electrical efficiency 3-4 times greater than radioisotope thermoelectric generator (RTG) systems and a higher power density than Brayton systems in the power range of interest for radioisotope-powered systems, Stirling-based DRPS is uniquely suited to benefit upcoming NASA missions. Much effort has been invested in the design and optimization of the thermal, mechanical, and materials aspects of FPSCs, but the electrical aspect has been more nebulous. Therefore, in this paper, a preliminary study will be presented to select the appropriate Stirling alternator voltage to develop a light and efficient system using available flight components. Power conversion systems face a trade between efficiency and system volume/mass with the optimal trade being determined by the application. Neglecting non-idealities related to insulation thickness and winding packing factor and assuming a constant winding area, alternator efficiency is independent of alternator voltage. Because wire size and alternator current can be traded against turn count and alternator voltage without impacting efficiency, the guidance on the optimal design comes from analysis of the controller power electronics and the remainder of the system. Properties of available flight-qualified electrical components, such as rated voltage/current and on-resistance, typically come in discrete values instead of a continuous range of values. With multiple components being required to form the power conversion stage of the controller, each limited to incremental values, a continuous optimization is of little benefit. Instead of a continuous optimization, a random process using properties of the available components can be used to develop a Pareto design front indicating the optimized trade space. The most advantageous trade between system efficiency and mass for the system at hand can then be selected from the range of feasible designs. In the final paper, the design process, assumptions, and preliminary results will be presented.

Free-Piston Stirling Convertor Controller, Dynamic↗

2022 Small Turbine Certification Awardee: NPS Solutions

Inverters convert the direct current power generated by wind turbines into the alternating current needed to serve local loads and feed onto the electricity grid. Although distributed wind systems typically supply electricity for homes and businesses near the turbines, these systems can also provide clean power to strengthen grid resilience. Certification to UL 1741 SA ensures that inverters will enable distributed wind turbines to provide grid support services and stay online when the grid experiences stability issues. Small companies often find the electrical listing process too complex and expensive to undertake on their own, so few distributed wind turbine inverters are certified to this standard. A U.S. Department of Energy (DOE) Competitiveness Improvement Project (CIP) award is helping NPS Solutions (NPS) secure this critical certification for the inverter in its 100-kilowatt NPS 100C wind turbine, which is optimized for on-site generation at farms, businesses, schools, hospitals, and remote locations.

CIP↗

Hall-Effect Current Sensors For Integrated Circuits

Built-in devices measure direct or alternating currents. Hall-effect sensors placed near constriction in conductor strip. Differential configuration reduces effects of stray magnetic fields, nonlinearities, and changes in temperature. Preliminary design studies and experiments with macroscopic commercial Hall-effect sensors conducted to assess feasibility, limitations, and need for further research and development of this concept. Potential applications include programmable power supplies and protective circuitry.

Rippel, Wally E.↗

Alternate-Fueled Combustion-Sector Emissions

In order to meet rapidly growing demand for fuel, as well as address environmental concerns, the aviation industry has been testing alternate fuels for performance and technical usability in commercial and military aircraft. Currently, alternate aviation fuels must satisfy MIL-DTL- 83133F(2008) (military) or ASTM D 7566- Annex(2011) (commercial) standards and are termed drop-in fuel replacements. Fuel blends of up to 50% alternative fuel blended with petroleum (JP-8), which have become a practical alternative, are individually certified on the market. In order to make alternate fuels (and blends) a viable option for aviation, the fuel must be able to perform at a similar or higher level than traditional petroleum fuel. They also attempt to curb harmful emissions, and therefore a truly effective alternate fuel would emit at or under the level of currently used fuel. This paper analyzes data from gaseous and particulate emissions of an aircraft combustor sector. The data were evaluated at various inlet conditions, including variation in pressure and temperature, fuel-to-air ratios, and percent composition of alternate fuel. Traditional JP-8+100 data were taken as a baseline, and blends of JP- 8+100 with synthetic-paraffinic-kerosene (SPK) fuel (Fischer-Tropsch (FT)) were used for comparison. Gaseous and particulate emissions, as well as flame luminosity, were assessed for differences between FT composition of 0%, 50%, and 100%. The data showed that SPK fuel (a FT-derived fuel) had slightly lower harmful gaseous emissions, and smoke number information corroborated the hypothesis that SPK-FT fuels are cleaner burning fuels.

Saxena, Nikita T.↗

An active homopolar magnetic bearing with high temperature superconductor (HTS) coils and ferromagnetic cores

A proof-of-feasibility demonstration showed that high temperature superconductor (HTS) coils can be used in a high-load, active magnetic bearing in liquid nitrogen. A homopolar radial bearing with commercially wound HTS (Bi 2223) bias and control coils produced over 200 lb (890 N) radial load capacity (measured non-rotating) and supported a shaft to 14000 rpm. The goal was to show that HTS coils can operate stably with ferromagnetic cores in a feedback controlled system at a current density similar to that in Cu in liquid nitrogen. Design compromises permitted use of circular coils with rectangular cross section. Conductor improvements will eventually permit coil shape optimization, higher current density and higher bearing load capacity. The bias coil, wound with non-twisted, multifilament HTS conductor, required negligible power to carry its direct current. The control coils were wound with monofilament HTS sheathed in Ag. These dissipated negligible power for direct current (i.e. for steady radial load components). When an alternating current (AC) was added, the AC component dissipated power which increased rapidly with frequency and quadratically with AC amplitude. In fact at frequencies above about 2 hz, the effective resistance of the control coil conductor actually exceeds that of the silver which is in electrical parallel with the oxide superconductor. This is at least qualitatively understandable in the context of a Bean-type model of flux and current penetration into a Type II superconductor. Fortunately the dynamic currents required for bearing stability are of small amplitude. These results show that while twisted multifilament conductor is not needed for stable levitation, twisted multifilaments will be required to reduce control power for sizable dynamic loads, such as those due to unbalance.

Brown, G. V.↗

Current Regulator For Sodium-Vapor Lamps

Regulating circuit maintains nearly-constant alternating current in sodium-vapor lamp. Regulator part of dc-to-ac inverter circuit used to supply power to street lamp from battery charged by solar-cell array.

Mclyman, W. T.↗

Optimal Planning and Operation of Multi-Frequency HVac Transmission Systems

Low-frequency high-voltage alternating-current (LF-HVac) transmission scheme has been recently proposed as an alternative solution to conventional 50/60-Hz HVac and high-voltage direct-current (HVdc) schemes for bulk power transfer. This paper proposes an optimal planning and operation for loss minimization in a multi-frequency HVac transmission system. In such a system, conventional HVac and LF-HVac grids are interconnected using back-to-back (BTB) converters. The dependence of system MW losses on converter dispatch as well as the operating voltage and frequency in the LF-HVac is discussed and compared with that of HVdc transmission. Based on the results of the loss analysis, multi-objective optimization formulations for both planning and operation stages are proposed. The planning phase decides a suitable voltage level for the LF-HVac grid, while the operation phase determines the optimal operating frequency and power dispatch of BTB converters, generators, and shunt capacitors. A solution approach that effectively handles the variations of transmission line parameters with the rated voltage and operating frequency in the LF-HVac grid is proposed. The proposed solutions of the planning and operation stages are evaluated using a multi-frequency HVac system. The results show a significant loss reduction and improved voltage regulation during a 24-hour simulation.