Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Comparison of near-background concentrations of Argon-37 and Xenon-133 in the Atmosphere

Radioisotopes of noble gases xenon and argon can be important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133Xe, 135Xe, 131mXe and 133mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010) and with a higher signal to background ratio, depending on the radioxenon background levels. Therefore, inclusion of 37Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations may represent an improvement in the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37Ar to evaluate the range of background concentrations. Samples were collected at multiple locations, with approximately half coming from a sampler co-located with an IMS xenon monitoring station (RN75). The range of 37Ar concentrations measured in atmospheric air samples was relatively narrow; for samples considered detectable, the minimum and maximum measured concentrations were 0.56 and 2.3 mBq/m3, respectively. Comparison of 37Ar and 133Xe concentrations measured at the IMS station indicated some correlation between the measured concentrations. The results presented here demonstrate the capability to detect background concentrations of 37Ar in atmospheric air and provide a basis for potential implementation of 37Ar monitoring at IMS stations.

Fritz, Brad G.↗

Nanopore Sequencing-Based Microbial Air Profiling Method for Crewed Spacecraft

Microbial monitoring of the International Space Station (ISS) atmosphere is vital to maintaining the health of the spacecraft and crew. Key to NASA’s microbial risk assessment is the identity of contaminating microorganisms in the environment. Historically, this has been achieved through impaction-based air sampling followed by culture. Identification of the microorganisms present requires sample return to Earth and lab-based analyses. While this culture-based approach has served to provide alerts to anomalies and overall confidence in the controls in place, it is not suitable for exploration missions with no sample return. Recently, significant advancements in molecular-based microbial monitoring via nanopore sequencing have been implemented onboard the ISS. Building on this work, multiple commercially available air samplers, compatible with downstream molecular analysis, were evaluated for use in the spaceflight environment. Through this assessment, the Coriolis Compact (Bertin Technologies), which uses cyclonic technology to collect bioaerosols onto the surface of a sterile cone, was selected for a larger-scale comparison to the current culture-based monitoring method. Using the Coriolis Compact, 1000 L of air was collected from the breakroom of an office building and a fitness center. The buffer used to dissociate the microbial cells from the surface of the cone was split between the NASA Microbiology Laboratory’s standard culture and Sanger sequencing-based method and the culture-independent nanopore sequencing method. The bacteria identified through culture were present in the nanopore data, with Micrococcus, Staphylococcus, and Moraxella being the most common cultured isolates, which is expected based on the media and growth conditions. Not surprisingly, the nanopore data yielded much higher diversity and paralleled that of previous atmospheric microbiome studies of human-occupied built environments. As compared to the culture-based data where the breakroom and fitness center data sets cluster in proximity, the nanopore data depicts the contrast of these atmospheric microbiomes. Moreover, the nanopore data were sufficient to meet NASA’s risk assessment needs and noted the culturable isolates routinely observed. This nanopore-based atmospheric microbial profiling method will enable near real-time environmental monitoring of crewed spacecraft as future missions extend beyond low-Earth orbit.

Brandon Dunbar↗

Measurements of concentrations of chlorofluoromethanes (CFMs) carbon dioxide and carbon isotope ratio in stratospheric and tropospheric air by grab-sampling systems

Measurements of concentrations of chlorofluoromethanes (CFMs), carbon dioxide and carbon isotope ratio in stratospheric and tropospheric air by grab-sampling systems are reported. The balloon-borne grab-sampling system has been launched from Sanriku Balloon Center three times since 1981. It consists of: (1) six sampling cylinders, (2) eight motor driven values, (3) control and monitor circuits, and (4) pressurized housing. Particular consideration is paid to the problem of contamination. Strict requirements are placed on the choice of materials and components, construction methods, cleaning techniques, vacuum integrity, and sampling procedures. An aluminum pressurized housing and a 4-m long inlet line are employed to prevent the sampling air from contamination by outgassing of sampling and control devices. The sampling is performed during the descent of the system. Vertical profiles of mixing ratios of CF2Cl2, CFCl3 and CH4 are given. Mixing ratios of CF2Cl2 and CFCl3 in the stratosphere do not show the discernible effect of the increase of those in the ground level background, and decrease with altitude. Decreasing rate of CFCl3 is larger than that of CF2Cl2. CH4 mixing ratio, on the other hand, shows diffusive equilibrium, as the photodissociation cross section of CH4 is small and concentrations of OH radical and 0(sup I D) are low.

Itoh, T.↗

Precision Gas System (PGS) Instrument Handbook

This precision gas system (PGS) makes high-accuracy, high-precision measurements of CO2 mixing ratio (ppmv dry air) in air sampled at 2, 4, 25, and 60 m above the ground.

54 ENVIRONMENTAL SCIENCES↗

Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) Winter Intensive Operational Period: Aerodynamic Particle Sizer Field Campaign Report

An aerodynamic particle sizer spectrometer (APS, model 3321 by TSI Inc., Shoreview, Minnesota) was deployed at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Eastern North Atlantic (ENA) observatory during the second (winter) intensive operational period (IOP) of the Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) field campaign. Data were collected from January 9 through February 26, 2018, covering the second deployment of the ARM Aerial Facility (AAF) aircraft within ACE-ENA. The standard ENA instrument suite does not provide measurements of aerosol particle size distribution for diameters greater than one micron. Properties of coarse-mode (super-micron) aerosols are rarely measured, although super-micron particles can play an important role in the aerosol life cycle, affecting aerosol optical properties and cloud nuclei activity (e.g., Clarke et al. 2003). The APS was deployed to fill this gap in particle size measurements: it is capable of measuring size-resolved concentration of the aerosols in the 0.5-20 μm range (aerodynamic diameter). The APS was installed in the aerosol trailer to sample through the main stack. Special attention was given to selection of the instrument location (just below the main stack) to minimize particle losses in the connecting lines. Most atmospheric aerosols are hygroscopic, so the measurement of the aerosol size distributions should either be performed in a controlled humidity environment or accompanied by concurrent measurement of the temperature and humidity of the sample air. The latter strategy was used during this deployment: a high-precision humidity/temperature transmitter (model EE08 by E+E Elektonik GMBH, Engerwitzdorf, Germany) was mounted in the APS sampling line immediately upstream of the APS inlet. A dedicated laptop computer was used for data collection and communications. The APS was controlled with vendor-supplied software (Aerosol Instrument Manager, ver. 10.1, TSI); aerosol size distribution data were collected over a period of 55 seconds and converted to one-minute averages. Temperature and humidity analog signals were acquired via analog-to-digital converter (ADC) module (model WTAIN-M by Weeder Technologies, Fort Walton Beach, Florida) using vendor-supplied software (ModCom) with 1- sec resolution. In post-processing, the APS data were exported from TSI proprietary format into “comma-separated value” American Standard Code for Information Interchange (ASCII) files and matched with appropriately averaged temperature and humidity data. Two significant periods of missing data were caused by local power outages. Vendor-supplied software was not designed for unattended operation: it needs to be manually restarted including sensor configuration setup.

ACE-ENA, Azores, ultra-high-sensitivity aerosol sp↗

Rapid System to Quantitatively Characterize the Airborne Microbial Community

Bioaerosols have been linked to a wide range of different allergies and respiratory illnesses. Currently, microorganism culture is the most commonly used method for exposure assessment. Such culture techniques, however, generally fail to detect between 90-99% of the actual viable biomass. Consequently, an unbiased technique for detecting airborne microorganisms is essential. In this Phase II proposal, a portable air sampling device his been developed for the collection of airborne microbial biomass from indoor (and outdoor) environments. Methods were evaluated for extracting and identifying lipids that provide information on indoor air microbial biomass, and automation of these procedures was investigated. Also, techniques to automate the extraction of DNA were explored.

Macnaughton, Sarah J.↗

Microbiological Contamination of Spacecraft

The International Space Station (ISS) Phase1 Program resulted in seven US astronauts residing aboard the Russian Space Station Mir between March 1995 and May 1998. Collaboration between U.S. and Russian scientists consisted of collection and analyses of samples from the crewmembers and the Mir and Shuttle environments before, during, and after missions that lasted from 75 to 209 days in duration. The effects of long-duration space flight on the microbial characteristics of closed life support systems and the interactions of microbes with the spacecraft environment and crewmembers were investigated. Air samples were collected using a Russian or U.S.-supplied sampler (SAS, RCS, or Burkard,) while surface samples were collected using contact slides (Hycon) or swabs. Mir recycled condensate and stored potable water sources were analyzed using the U.S.-supplied Water Experiment Kit. In-flight analysis consisted of enumeration of levels of bacteria and fungi. Amounts of microorganisms seen in the air and on surfaces were mostly within acceptability lin1its; observed temporal fluctuations in levels of microbes probably reflect changes in environmental conditions (e.g., humidity). All Mir galley hot water samples were within the standards set for Mir and the ISS. Microbial isolates were returned to Earth for identification of bacterial and fungal isolates. Crew samples (nose, throat, skin, urine, and feces) were analyzed using methods approved for the medical evaluations of Shuttle flight crews. No significant changes in crew microbiota were found during space flight or upon return relative to preflight results. Dissemination of microbes between the crew and environment was demonstrated by D A fingerprinting. Some biodegradation of spacecraft materials was observed. Accumulation of condensate allowed for the recovery of a wide range of bacteria and fungi as well as some protozoa and dust mites.

Pierson, D. L.↗

Industrial Hygiene Asbestos Negative Exposure Assessment Flooring Material Penetration and Sampling

This negative exposure assessment (NEA) for asbestos is a certification stating that a specific type of work involving one or more hazardous materials has been evaluated and found not to result in exposure in excess of applicable standards. This assessment included the collection of personal exposure air samples and a review of the operation by an Industrial Hygienist. Work which deviates from the provisions below falls outside of the scope of this NEA and may result in exposure of personnel to hazardous materials in excess of applicable standards. Such operations must be independently evaluated.

54 ENVIRONMENTAL SCIENCES↗

Water vapor measurement system in global atmospheric sampling program, appendix

The water vapor measurement system used in the NASA Global Atmospheric Sampling Program (GASP) is described. The system used a modified version of a commercially available dew/frostpoint hygrometer with a thermoelectrically cooled mirror sensor. The modifications extended the range of the hygrometer to enable air sample measurements with frostpoint temperatures down to -80 C at altitudes of 6 to 13 km. Other modifications were made to permit automatic, unattended operation in an aircraft environment. This report described the hygrometer, its integration with the GASP system, its calibration, and operational aspects including measurement errors. The estimated uncertainty of the dew/frostpoint measurements was + or - 1.7 Celsius.

Englund, D. R.↗

Space Shuttle exhausted aluminum oxide - A measured particle size distribution

Aluminum oxide (A2O3) particles were collected from the Space Shuttle exhaust plume immediately following the launch of STS-34 on October 18, 1989. A2O3 samples were obtained at 2.4, 3.0, 3.2, and 7.4 km in altitude. The samples were analyzed using SEM to develope particle size distributions. There were no indications that the particle size distribution changed as a function of altitude. The particle number concentrations per cubic meter of air sampled for the four collections was found to fit an exponential expression.

Cofer, W. R., III↗

Acetone in theGlobal Troposphere: Its Possible Role as a Global Source of PAN

Oxygenated hydrocarbons are thought to be important components of the atmosphere but, with the exception of formaldehyde, very little about their distribution and fate is known. Aircraft measurements of acetone (CH3COCH3), PAN (CH3CO3NO2) and other organic species (e. g. acetaldehyde, methanol and ethanol) have been performed over the Pacific, the southern Atlantic, and the subarctic atmospheres. Sampled areas extended from 0 to 12 km altitude over latitudes of 70 deg N to 40 deg S. All measurements are based on real time in-situ analysis of cryogenically preconcentrated air samples. Substantial concentrations of these oxygenated species (10-2000 ppt) have been observed at all altitudes and geographical locations in the troposphere. Important sources include, emissions from biomass burning, plant and vegetation, secondary oxidation of primary non-methane hydrocarbons, and man-made emissions. Direct measurements within smoke plumes have been used to estimate the biomass burning source. Photochemistry studies are used to suggest that acetone could provide a major source of peroxyacetyl radicals in the atmosphere and play an important role in sequestering reactive nitrogen. Model calculations show that acetone photolysis contributes significantly to PAN formation in the middle and upper troposphere.

Singh, H. B.↗

SCILLA Secondary Aerosol Volume Concentration Airborne Data

This data set contains secondary aerosol volume concentration in cubic micrometers per cubic centimeter (um^3/cm^3). The aerosol was generated in an oxidation flow reactor (OFR) and its volume concentration measured with a scanning mobility particle sizer (SMPS). Both components were designed and built at the University of California Riverside. Ambient particles were removed with a Teflon filter upstream of the OFR and then pure ammonium sulfate particles were added to create a stable aerosol surface area on which low-volatility oxidation products condense. High concentrations of hydroxyl radical (OH) formed inside the OFR accelerate the oxidative chemistry that would typically occur over a period of several days in the atmosphere, resulting in the production of secondary aerosol from precursor gases present in the ambient air. Concentrations of added ozone and water vapor were controlled to produce the desired and approximately constant level of photochemical aging. The reactor temperature was controlled, while the pressure was not, and was always slightly lower than that of the sampled outside air. Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between the OFR and several gas analyzers (NOx, CO, O3, and H2O). Though not contained in these files, data from an aerosol mass spectrometer intermittently operated downstream of the OFR are also available.

{"secondary aerosol concentration",aerosol_concent↗

Respirable particulate monitoring with remote sensors. (Public health ecology: Air pollution)

The feasibility of monitoring atmospheric aerosols in the respirable range from air or space platforms was studied. Secondary reflectance targets were located in the industrial area and near Galveston Bay. Multichannel remote sensor data were utilized to calculate the aerosol extinction coefficient and thus determine the aerosol size distribution. Houston Texas air sampling network high volume data were utilized to generate computer isopleth maps of suspended particulates and to establish the mass loading of the atmosphere. In addition, a five channel nephelometer and a multistage particulate air sampler were used to collect data. The extinction coefficient determined from remote sensor data proved more representative of wide areal phenomena than that calculated from on site measurements. It was also demonstrated that a significant reduction in the standard deviation of the extinction coefficient could be achieved by reducing the bandwidths used in remote sensor.

Severs, R. K.↗

Comprehensive analysis of airborne contaminants from recent Spacelab missions

The Shuttle experiences unique air contamination problems because of microgravity and the closed environment. Contaminant build-up in the closed atmosphere and the lack of a gravitational settling mechanism have produced some concern in previous missions about the amount of solid and volatile airborne contaminants in the Orbiter and Spacelab. Degradation of air quality in the Orbiter/Spacelab environment, through processes such as chemical contamination, high solid-particulate levels, and high microbial levels, may affect crew performance and health. A comprehensive assessment of the Shuttle air quality was undertaken during STS-40 and STS-42 missions, in which a variety of air sampling and monitoring techniques were employed to determine the contaminant load by characterizing and quantitating airborne contaminants. Data were collected on the airborne concentrations of volatile organic compounds, microorganisms, and particulate matter collected on Orbiter/Spacelab air filters. The results showed that STS-40/42 Orbiter/Spacelab air was toxicologically safe to breathe, except during STS-40 when the Orbiter Refrigerator/Freezer unit was releasing noxious gases in the middeck. On STS-40, the levels of airborne bacteria appeared to increase as the mission progressed; however, this trend was not observed for the STS-42 mission. Particulate matter in the Orbiter/Spacelab air filters was chemically analyzed in order to determine the source of particles. Only small amounts of rat hair and food bar (STS-40) and traces of soiless medium (STS-42) were detected in the Spacelab air filters, indicating that containment for Spacelab experiments was effective.

Matney, M. L.↗

ARM Carbon Cycle Gases Flasks at SGP Site

Data from flasks are sampled at the Atmospheric Radiation Measurement Program ARM, Southern Great Plains Site and analyzed by the National Oceanic and Atmospheric Administration NOAA, Earth System Research Laboratory ESRL. The SGP site is included in the NOAA Cooperative Global Air Sampling Network. The surface samples are collected from a 60 m tower at the ARM SGP Central Facility, usually once per week in the afternoon. The aircraft samples are collected approximately weekly from a chartered aircraft, and the collection flight path is centered over the tower where the surface samples are collected. The samples are collected by the ARM and LBNL Carbon Project.

54 ENVIRONMENTAL SCIENCES↗

Low-frequency sound absorption measurements in air

Thirty sets of sound absorption measurements in air at a pressure of 1 atmosphere are presented at temperatures from 10 C to 50 C, relative humidities from 0 to 100 percent, and frequencies from 10 to 2500 Hz. The measurements were conducted by the method of free decay in a resonant tube having a length of 18.261 m and bore diameter of 0.152 m. Background measurements in a gas consisting of 89.5 percent N2 and 10.5 percent Ar, a mixture which has the same sound velocity as air, permitted the wall and structural losses of the tube to be separated from the constituent absorption, consisting of classical rotational and vibrational absorption, in the air samples. The data were used to evaluate the vibrational relaxation frequencies of N2 and/or O2 for each of the 30 sets of meteorological parameters. Over the full range of humidity, the measured relaxation frequencies of N2 in air lie between those specified by ANSI Standard S1.26-1978 and those measured earlier in binary N2H2O mixtures. The measured relaxation frequencies could be determined only at very low values of humidity, reveal a significant trend away from the ANSI standard, in agreement with a prior investigation.

Zuckerwar, A. J.↗

Low-frequency absorption of sound in air

Thirty sets of sound absorption measurements in air at a pressure of 1 atmosphere are presented at temperatures from 10 C to 50 C, relative humidities from 0 to 100 percent, and frequencies from 10 to 2500 Hz. The measurements were conducted by the method of free decay in a resonant tube having a length of 18.261 m and bore diameter of 0.152 m. Background measurements in a gas consisting of 89.5 percent N2 and 10.5 percent Ar, a mixture which has the same sound velocity as air, permitted the wall and structural losses of the tube to be separated from the constituent absorption, consisting of classical rotational and vibrational absorption, in the air samples. The data were used to evaluate the vibrational relaxation frequencies of N2 and/or O2 for each of the 30 sets of meteorological parameters. Over the full range of humidity, the measured relaxation frequencies of N2 in air lie between those specified by ANSI Standard S1.26-1978 and those measured earlier in binary N2H2O mixtures. The measured relaxation frequencies could be determined only at very low values of humidity, reveal a significant trend away from the ANSI standard, in agreement with a prior investigation.

Zuckerwar, A. J.↗