Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Acoustics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Density of molten oxides measured in an aero-acoustic levitator

Knowing the thermophysical properties of high-temperature melts can aid the design of melt processes and validate atomic structural models, such as those used in studying glass formation. Property measurements on such melts are challenging, however, due to container-related contamination and heterogeneous nucleation. Containerless processing techniques that employ levitation can be used to avoid these obstacles. In that context, we demonstrate here the application of silhouette imaging to measure the density of molten oxides in an aero-acoustic levitation instrument (AAL). The AAL combines gas jet levitation with actively controlled acoustic positioning to enable full optical access to samples ca. 2–4 mm in diameter, which are laser beam heated and melted. The cross sections of molten drops are imaged using a monochromatic light source and narrowband-filtered camera. Melt volume is calculated from the cross sections and used to find density at several temperatures ranging 1530–1920 K, including up to 350 K of supercooling. We report densities for CaAl 2 O 4 , Ca 12 Al 14 O 33 , CaSiO 3 , their Fe 2 O 3 -bearing analogs, and 83TiO 2 -17RE 2 O 3 (RE = La or Nd). These provide important benchmarks of the capabilities, measurement uncertainties, and future outlook for this technique.

36 MATERIALS SCIENCE↗

DESI 2024 VI: cosmological constraints from the measurements of baryon acoustic oscillations

We present cosmological results from the measurement of baryon acoustic oscillations (BAO) in galaxy, quasar and Lyman-α forest tracers from the first year of observations from the Dark Energy Spectroscopic Instrument (DESI), to be released in the DESI Data Release 1. DESI BAO provide robust measurements of the transverse comoving distance and Hubble rate, or their combination, relative to the sound horizon, in seven redshift bins from over 6 million extragalactic objects in the redshift range 0.1 < z < 4.2. To mitigate confirmation bias, a blind analysis was implemented to measure the BAO scales. DESI BAO data alone are consistent with the standard flat ΛCDM cosmological model with a matter density Ω m =0.295±0.015. Paired with a baryon density prior from Big Bang Nucleosynthesis and the robustly measured acoustic angular scale from the cosmic microwave background (CMB), DESI requires H 0 =(68.52±0.62) km s -1 Mpc -1 . In conjunction with CMB anisotropies from Planck and CMB lensing data from Planck and ACT, we find Ω m =0.307± 0.005 and H 0 =(67.97±0.38) km s -1 Mpc -1 . Extending the baseline model with a constant dark energy equation of state parameter w, DESI BAO alone requirew=-0.99 +0.15 -0.13 . In models with a time-varying dark energy equation of state parametrised by w 0 and w a , combinations of DESI with CMB or with type Ia supernovae (SN Ia) individually prefer w 0 > -1 and w a < 0. This preference is 2.6σ for the DESI+CMB combination, and persists or grows when SN Ia are added in, giving results discrepant with the ΛCDM model at the 2.5σ, 3.5σ or 3.9σ levels for the addition of the Pantheon+, Union3, or DES-SN5YR supernova datasets respectively. For the flat ΛCDM model with the sum of neutrino mass ∑ m ν free, combining the DESI and CMB data yields an upper limit ∑ m ν < 0.072 (0.113) eV at 95% confidence for a ∑ m ν > 0 (∑ m ν > 0.059) eV prior. These neutrino-mass constraints are substantially relaxed if the background dynamics are allowed to deviate from flat ΛCDM.

79 ASTRONOMY AND ASTROPHYSICS↗

Reconsidering tympanal-acoustic interactions leads to an improved model of auditory acuity in a parasitoid fly

Although most binaural organisms locate sound sources using neurological structures to amplify the sounds they hear, some animals use mechanically coupled hearing organs instead. One of these animals, the parasitoid fly Ormia ochracea (O. ochracea), has astoundingly accurate sound localization abilities. It can locate objects in the azimuthal plane with a precision of 2°, equal to that of humans, despite an intertympanal distance of only 0.5 mm, which is less than 1/100th of the wavelength of the sound emitted by the crickets that it parasitizes. O. ochracea accomplishes this feat via mechanically coupled tympana that interact with incoming acoustic pressure waves to amplify differences in the signals received at the two ears. In 1995, Miles et al developed a model of hearing mechanics in O. ochracea that represents the tympana as flat, front-facing prosternal membranes, though they lie on a convex surface at an angle from the flies' frontal and transverse planes. The model works well for incoming sound angles less than ±30° but suffers from reduced accuracy (up to 60% error) at higher angles compared to response data acquired from O. ochracea specimens. Despite this limitation, it has been the basis for bio-inspired microphone designs for decades. Here, we present critical improvements to this classic hearing model based on information from three-dimensional reconstructions of O. ochracea's tympanal organ. We identified the orientation of the tympana with respect to a frontal plane and the azimuthal angle segment between the tympana as morphological features essential to the flies' auditory acuity, and hypothesized a differentiated mechanical response to incoming sound on the ipsi- and contralateral sides that depend on these features. We incorporated spatially-varying model coefficients representing this asymmetric response, making a new quasi-two-dimensional (q2D) model. The q2D model has high accuracy (average errors of under 10%) for all incoming sound angles. This improved biomechanical model may inform the design of new microscale directional microphones and other small-scale acoustic sensor systems.

36 MATERIALS SCIENCE↗

Surface acoustic waves and lattice vibrations in two-dimensional Ti 3 ⁢C 2 ⁢𝑇 𝑥 (𝑇 =O, F) MXene films

We investigated surface acoustic wave (SAW) propagation and lattice vibrations in two-dimensional (2D) titanium carbide (Ti 3 ⁢C 2 ⁢𝑇 x ) MXene films as a function of surface termination and layer stacking, using atomistic simulations. We found that SAW propagation velocity is highly sensitive to both single-layer properties and interlayer bonding. Surface terminations significantly modulate wave behavior, with oxygen and fluorine terminations producing distinct effects on wave propagation, with oxygen-terminated monolayers exhibiting 20% higher wave speeds than fluorine counterparts due to strengthened intralayer bonds. Key observations include the transition from one to two layers causing wave speed variations, and the development of interlayer modes that generate more dispersed lattice vibrations. As the film layer thickness increases, SAW propagation becomes predominantly confined to the upper surface, with coherence of vibrational modes diminishing in multilayer structures. These findings suggest MXene terminations and layer stacking are crucial parameters for controlling SAW behavior, offering promising avenues for novel acoustic wave device applications.

2-dimensional systems↗

DESI DR2 results. II. Measurements of baryon acoustic oscillations and cosmological constraints

We present baryon acoustic oscillation (BAO) measurements from more than 14 million galaxies and quasars drawn from the Dark Energy Spectroscopic Instrument (DESI) Data Release 2 (DR2), based on three years of operation. For cosmology inference, these galaxy measurements are combined with DESI Lyman-𝛼 forest BAO results presented in a companion paper (M. Abdul-Karim et al., companion paper, Phys. Rev. D 112, 083514 2025.). The DR2 BAO results are consistent with DESI DR1 and the Sloan Digital Sky Survey, and their distance-redshift relationship matches those from recent compilations of supernovae (SNe) over the same redshift range. The results are well described by a flat Λ cold dark matter (Λ⁢CDM) model, but the parameters preferred by BAO are in mild, 2.3⁢𝜎 tension with those determined from the cosmic microwave background (CMB), although the DESI results are consistent with the acoustic angular scale 𝜃 * that is well measured by Planck. This tension is alleviated by dark energy with a time-evolving equation of state parametrized by 𝑤0 and 𝑤𝑎, which provides a better fit to the data, with a favored solution in the quadrant with 𝑤 0 >−1 and 𝑤 𝑎 <0. This solution is preferred over Λ ⁢CDM at 3.1⁢𝜎 for the combination of DESI BAO and CMB data. When also including SNe, the preference for a dynamical dark energy model over Λ⁢ CDM ranges from 2.8 − 4.2⁢𝜎 depending on which SNe sample is used. We present evidence from other data combinations which also favor the same behavior at high significance. From the combination of DESI and CMB we derive 95% upper limits on the sum of neutrino masses, finding ∑𝑚 𝜈 < 0.064 eV assuming Λ ⁢CDM and ∑𝑚 𝜈 < 0.16 eV in the 𝑤0⁢𝑤𝑎 model. Unless there is an unknown systematic error associated with one or more datasets, it is clear that Λ⁢ CDM is being challenged by the combination of DESI BAO with other measurements and that dynamical dark energy offers a possible solution.

Baryon acoustic oscillations↗

Environmental cell for in situ X-ray synchrotron micro-CT imaging with simultaneous acoustic measurements

Synchrotron radiation provides the necessary spatial and temporal resolution for non-invasive operando studies of dynamic processes under complex environmental conditions. Here a new environmental cell for simultaneous in situ dynamic X-ray imaging and measuring acoustic properties of geological samples is presented. The primary purpose of this cell is to study gas-hydrate formation in porous geo-materials and its influence on their acoustic properties. The cell is designed for cylindrical samples of 9 mm in diameter, confining and pore pressures up to 12 MPa, and temperatures from –20°C to room temperature. The cell is portable and can be easily assembled and operated at different X-ray sources. This cell enables a wide range of experiments studying physical/chemical processes in the Earth subsurface that change the mechanical properties of rocks (geochemical reactions, phase transitions, etc.).

47 OTHER INSTRUMENTATION↗

Evaluation of a coastal acoustic buoy for cetacean detections, bearing accuracy and exclusion zone monitoring

Abstract There is strong socio‐political support for offshore wind development in US territorial waters and construction is planned off several east coast states. Some of the planned development sites coincide with important habitat for critically endangered North Atlantic right whales. Both exclusion zones and passive acoustic monitoring are important tools for managing interactions between marine mammals and human activities. Understanding where animals are with respect to exclusion zones is important to avoid costly construction delays while minimizing the potential for negative impacts. Impact piling from construction of hundreds of offshore wind turbines likely require exclusion zones as large as 10 km. We have developed a three‐hydrophone passive acoustic monitoring system that provides bearing information along with marine mammal detections to allow for informed management decisions in real‐time. Multiple units form a monitoring system designed to determine whether marine mammal calls originate from inside or outside of an exclusion zone. In October 2021, we undertook a full system validation, with a focus on evaluating the detection range and bearing accuracy of the system with respect to right whale upcalls. Five units were deployed in Mid‐Atlantic waters and we played more than 3500 simulated right whale upcalls at known locations to characterize the detection function and bearing accuracy of each unit. The modelled results of the detection function error were then used to compare the effectiveness of a bearing‐based system to a single sensor that can only detect a signal but not ascertain directivity. Field trials indicated maximum detection ranges from 4–7.3 km depending on source and ambient noise levels. Simulations showed that incorporating bearing detections provide a substantial improvement in false alarm rates (6 to 12 times depending on number of units, placement and signal to noise conditions) for a small increase in the risk of missed detections inside of an exclusion zone (1%–3%). We show that the system can be used for monitoring exclusion zones and clearly highlight the value of including bearing estimation into exclusion zone monitoring plans while noting that placement and configuration of units should reflect anticipated ambient noise conditions.

17 WIND ENERGY↗

Survival, healing, and swim performance of juvenile migratory sea lamprey ( Petromyzon marinus ) implanted with a new acoustic microtransmitter designed for small eel-like fishes

Background: Little is known about the transformer stage of the parasitic lampreys, a brief but critical period that encompasses juvenile out-migration from rivers to lakes or oceans to begin parasitic feeding. Information about this life stage could have significant conservation implications for both imperiled and invasive lampreys. We investigated tag retention, survival, wound healing, and swim performance of newly transformed sea lamprey (Petromyzon marinus) implanted with a new micro-acoustic transmitter, the eel–lamprey acoustic transmitter (ELAT), in a controlled laboratory environment. Results: The 61-day survival of our tagged subjects was 71%, within the range reported in similar studies of juvenile lampreys. However, survival was significantly lower in the tagged animals (vs control), with no effect statistically attributable to measures of animal length, mass, condition, or population of origin (Great Lakes vs. Atlantic drainage). Mortality in tagged fish was concentrated in the first four days post-surgery, suggesting injury from the surgical process. An unusually long recovery time from anesthesia may have contributed to the increased mortality. In a simple burst swim assay, tagged animals swam significantly slower (– 22.5%) than untagged animals, but were not significantly different in endurance swim tests. A composite wound healing score at day four was a significant predictor of maximum burst swim speed at day 20, and wound condition was related to animal mass, but not length, at the time of tagging. Conclusions: Impairments to survival and swim performance of juvenile sea lamprey implanted with the ELAT transmitter were within currently reported ranges for telemetry studies with small, difficult to observe fishes. Our results could be improved with more refined anesthesia and surgical techniques. The ability to track migratory movements of imperiled and pest populations of parasitic lampreys will improve our ability to estimate vital rates that underlie recruitment to the adult population (growth, survival) and to investigate the environmental factors that regulate the timing and rates of movement, in wild populations.

59 BASIC BIOLOGICAL SCIENCES↗

A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process

Recent progress in sensing techniques and data analytics tools have significantly accelerated the development of Wire Arc Additive Manufacturing (WAAM) systems. This data centric approach emphasizes leveraging available data throughout the production process to optimize performance. Integration of extensive data analysis provides the opportunity to improve precision, reduce waste, and enhance the quality of produced parts. This method relies on AI/ML models and optimization techniques, which are developed using the data collected from various sources, including in-situ sensors, ex-situ imaging, and manufacturing process parameters. The quality and diversity of this data, along with the alignment between different data streams (achieved through spatiotemporal registration) are critical for the successful development of AI/ML and optimization models. In this work, we present a spatiotemporally registered dataset generated during the WAAM process of deposition of a rectangular block. The dataset includes the comprehensive description of deposition process, process parameters, in-situ collected welding characteristics, acoustic data, and X-Ray Computed Tomography analysis data for the build. Dataset A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process has arisen under UT-Battelle, LLC’s Prime Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy (DOE) to manage and operate the Oak Ridge National Laboratory. UT-Battelle, LLC will not assert any rights under United States law or under the Prime Contract it has in the dataset against any user of the dataset, including any copyrights or patent rights. UT-Battelle, LLC requests that attribution to the dataset is provided as academically appropriate.

42 ENGINEERING↗

Utah FORGE Project 3-2417: Simulations for Distributed Acoustic Sensing Strain Signatures as an Indicator of Fracture Connectivity

This dataset encompasses simulations of strain signatures from both hydraulically connected and "near-miss" fractures in enhanced geothermal systems (EGS). The files and results are presented from the perspective of digital acoustic sensing's (DAS) potential to differentiate the two fracture types. This dataset was acquired by the FOGMORE R&D project (Fiber Optic Geophysical MOnitoring of Reservoir Evolution), under Utah FORGE R&D Project 3-2417. Included are simulation and results via MatLab and COMSOL files, as well as a thesis and paper summarizing the results. Some stimulated fractures may be incomplete, approaching but not intersecting the production well. These "near-miss" fractures can be addressed in future stimulation stages or re-stimulated to complete the connection. We propose the use of fiber optic distributed acoustic sensing (DAS) as a method by which near-miss stimulated fractures may be identified and distinguished from hydraulically connected fractures. The low-frequency sub-nanostrain signatures of both complete and near-miss fractures in DAS data are simulated in this study using a hydrogeomechanical discrete fracture network model. The spatial distribution of strain was found to be an accurate indicator. However, this indicator must be evaluated in the context of DAS gauge length and spatial sampling. These simulations are a precursor to tests conducted at FORGE in 2023.

15 GEOTHERMAL ENERGY↗

ARIS Acoustic Camera Data Around a 5kW In-River Turbine from Tanana River Test Site

Four days (June 14-17, 2021) of ARIS acoustic camera data from the main research barge of the Tanana River Test Site operated by UAF. Data are collected sidelooking with the turbine in part of the field of view. This data was collected as part of a fish collision risk study. An acoustic camera was used rather than a traditional underwater camera due to the high levels of suspended sediments at the Tanana River Test Site.

16 TIDAL AND WAVE POWER↗

Integrated Harsh Environment Gas / Temperature Wireless Microwave Acoustic Sensor System for Fossil Energy Applications

There is a significant need for sensors capable of detecting gases, such as H 2 , O 2 , NO x , SO x within harsh environments encountered in power plants, industrial manufacturing, oil and gas exploration, and aerospace applications. This project successfully demonstrated the use of wireless microwave acoustic sensor technology for the detection of gases (H 2 or O 2 ) from ambient temperatures up to 650°C. The work focused on langasite (LGS) based surface acoustic wave resonator (SAWR) sensors as the harsh-environment sensor platform and explored multiple combinations of high-temperature thin films and device structures which were used to increase the sensor platform stability and detection capability at temperatures in the operational range of 150°C to 700°C. Specific material configurations that were investigated include: yttria-stabilized-zirconia (YSZ) decorated with Pt nanoparticles, atomic layer deposited (ALD) Al 2 O 3 , palladium, and Pt/Al 2 O 3 co-deposited electrode alloys. Through the deposition of YSZ at temperatures as high as 850°C and the use of graded alloy concentrations of Pt in the fabrication of the Pt/Al 2 O 3 electrode structures, film stress problems were mitigated, and sensor operation and stability achieved. To test and evaluate SAWR sensor performance for the detection of H 2 and O 2 under the influence of temperature variations, a comprehensive gas sensor control system and test apparatus was created to operate within a laboratory box furnace-controlled environment. In addition to the advancement in thin film materials through the deposition and fabrication techniques mentioned above, the work characterized the performance of sensors containing these films in the presence of oxidizing and reducing gases between 25°C and 700°C. In particular, the work revealed that the exposure of the SAWR sensor surfaces to oxidizing environments significantly improve the sensor response to H 2 , whereas the exposure of the sensor to reducing environments at high temperatures (≈ 500°C) renders the sensor irresponsive to H 2 , requiring sensor surface treatment at high temperatures (above 500°C) to recover the responsiveness to H 2 . The SAWR sensors have been also tested for wireless operation and array operation using multiple orientations to resolve the detection of gases under temperature variations. The work developed at the University of Maine was aided by a collaboration with the NETL Research and Innovation Center, Pittsburgh, PA, where thin film materials and device structures fabricated at UMaine were tested and characterized using NETL gas reactors and surface analysis techniques. SAWR sensors fabricated at UMaine were exposed multiple times to temperatures up to 700°C and H 2 concentrations up to 100% in the NETL facilities to measure the sensor performance. Environetix Technologies Corporation, a UMaine harsh-environment sensor spin-off company, also provided support and assistance in sensor system testing and implementation. The sensor small size and configuration allows flexible sensor placement and embedding of multiple sensor arrays into a variety of components within power systems and other aerospace or industrial settings that need to be interrogated wirelessly. The SAW platform is an attractive option for high-temperature harsh-environment gas sensing applications due to its inherent features, namely small size, capability of battery-free and wireless operation, and cost effective scale production using well-established production techniques from the semiconductor industry. The research findings achieved in this work, particularly advances regarding the fabrication and performance of the SAWR gas sensor platform, can be adapted and transferred to industrial power plants and other harsh environments.

01 COAL, LIGNITE, AND PEAT↗

Sodium Hydrogen Sensor and Acoustic Flow Sensor Development

This report documents the development of diffusion-type hydrogen meters (DTHMs) as part of a steam generator leak detection system (SGLDS) of sodium-cooled fast reactors (SFR) and the demonstration of the capabilities of acoustic flowmeters, including a commercial UTFM (Flexim FLUXUS F721) and an Argonne HT acoustic flowmeter running on shear-to-longitudinal mode. It also evaluates two Argonne permanent magnet flowmeters (PMFMs).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Surface Acoustic Wave Sensors for Refrigerant Leak Detection: Compact, Inexpensive, Selective and Sensitive Sensors

Pacific Northwest National Laboratory (PNNL), in collaboration with Parker and Hannifin, is developing a compact, inexpensive, and highly sensitive and selective surface acoustic wave sensor coated with fluorophillic sorbent for detecting fluorocarbon leaks from HVAC systems. Having a highly effective sorbent sensitive to fluorocarbon refrigerant vapors provides a means to develop a sensing device for leak detection. Surface acoustic wave (SAW) sensors with a gas sensing film deposited between the delay lines or on the interdigital transducer have been used to detect gas and vapor molecules in harsh environments with high sensitivity. As part of this project, PNNL screened several sorbent materials that are shown to be selective towards fluorocarbon refrigerant (R32) molecule. The identified sorbent materials were synthesized, characterized, and tested towards R32 using various spectroscopic technique. Next, the sorbent material was coated on a SAW sensor as a thin film using vapor deposition and drop coating methods. The coated thin film was further characterized and tested towards the detection of pure R32 and R32 in ambient air at room temperature to demonstrate the SAW response towards R32 in presence of other competing gases and vapors in air.

42 ENGINEERING↗

Classification of Ultrasonic Weld Quality using Acoustic Signatures Acquired During Manufacture

Ultrasonic welding is a process is based on generating a solid-state bond between two metals by applying moderate pressure and high intensity sound waves (20-70 kHz frequencies) at their interface. During the solid-state process numerous material, surface, instrument, and environmental factors contribute to bond formation, strength, and durability. The inherent difficulty of measuring and controlling each of these factors has, to date, made predicting bond quality elusive. In this work, a Sonics model MWB20 ultrasonic spot welder with integral base, was used to produce a variety of welds of different metal foils under varying weld conditions. Acoustic measurements were recorded throughout the measurement process. Subsequent analysis of the signals using metrics that approximate the energy dispersed during the weld proved to successfully predict weld quality. Two metrics based on normalized energy differential and Renyi entropy were developed into Python and C++ scripts for direct analysis of weld acoustic data.

36 MATERIALS SCIENCE↗

Acoustic Tomography System (CRADA Final Report)

NREL will install the CU/CIRES acoustic tomography array at the National Wind Technology Center (NWTC). The system consists of 9 freestanding towers of 9.1m height that are currently located at the NWTC. On these towers are installed a series of microphones and speakers. One center tower holds a sonic anemometer and temperature probe. The purpose of the acoustic tomography system is to measure complex flow fields surrounding wind turbine arrays that influence wind farm energy production and reliability. There is currently no funding to test and research the system (just install it), but NREL and CU researchers will write proposals that will fund the actual research with this unique measurement technology.

17 WIND ENERGY↗

Acoustic and Genetic Data Can Reduce Uncertainty Regarding Populations of Migratory Tree-Roosting Bats Impacted by Wind Energy

Wind turbine-related mortality may pose a population-level threat for migratory tree-roosting bats, such as the hoary bat (Lasiurus cinereus) in North America. These species are dispersed within their range, making it impractical to estimate census populations size using traditional survey methods. Nonetheless, understanding population size and trends is essential for evaluating and mitigating risk from wind turbine mortality. Using various sampling techniques, including systematic acoustic sampling and genetic analyses, we argue that building a weight of evidence regarding bat population status and trends is possible to (1) assess the sustainability of mortality associated with wind turbines; (2) determine the level of mitigation required; and (3) evaluate the effectiveness of mitigation measures to ensure population viability for these species. Long-term, systematic data collection remains the most viable option for reducing uncertainty regarding population trends for migratory tree-roosting bats. We recommend collecting acoustic data using the statistically robust North American Bat Monitoring Program (NABat) protocols and that genetic diversity is monitored at repeated time intervals to show species trends. There are no short-term actions to resolve these population-level questions; however, we discuss opportunities for relatively short-term investments that will lead to long-term success in reducing uncertainty.

17 WIND ENERGY↗