Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerator facilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Simulations of neutron unbound physics for Geant4

The study of neutron unbound systems via the invariant mass technique is the primary focus of the MoNA Collaboration, which built and operates the Modular Neutron Array (MoNA) and the Large multi-Institutional Scintillator Array (LISA) at FRIB. Advancements in nuclear structure from theory and experiment along the neutron dripline have presented opportunities to understand the nature of unbound systems in higher mass nuclei. The GEometry ANd Tracking (Geant4) platform has been used in high-energy and nuclear physics to simulate particle interactions with as much detail as the user desires. Geant4 currently does not have a physics class to simulate neutron unbound systems. Given the advancement of accelerator facilities and active searches along the neutron dripline, detailed simulations to study the breakup of neutron unbound systems, are necessary. Furthermore, the implementation of the breakup of neutron unbound systems in Geant4 will be presented.

Neutron dripline↗

Beam-spin asymmetry Σ for Σ – hyperon photoproduction off the neutron

We report a new measurement of the beam-spin asymmetry $\boldsymbol{\Sigma}$ for the $\vec{\gamma} n \rightarrow K^+\Sigma^-$ reaction using quasi-free neutrons in a liquid-deuterium target. The new dataset includes data at previously unmeasured photon energy and angular ranges, thereby providing new constraints on partial wave analyses used to extract properties of the excited nucleon states. The experimental data were obtained using the CEBAF Large Acceptance Spectrometer (CLAS), housed in Hall B of the Thomas Jefferson National Accelerator Facility (JLab). The CLAS detector measured reaction products from a liquid-deuterium target produced by an energy-tagged, linearly polarised photon beam with energies in the range 1.1 to 2.3 GeV. Predictions from an isobar model indicate strong sensitivity to $N(1720)3/2^+$, $\Delta(1900)1/2^-$, and $N(1895)1/2^-$, with the latter being a state not considered in previous photoproduction analyses. When our data are incorporated in the fits of partial-wave analyses, one observes significant changes in $\gamma$-$n$ couplings of the resonances which have small branching ratios to the $\pi N$ channel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics with CEBAF at 12 GeV and future opportunities

Here, we summarize the ongoing scientific program of the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) and give an outlook into future opportunities. The program addresses important topics in nuclear, hadronic, and electroweak physics, including nuclear femtography, meson and baryon spectroscopy, quarks and gluons in nuclei, precision tests of the standard model and dark sector searches. Potential upgrades of CEBAF and their impact on scientific reach are discussed, such as higher luminosity, the addition of polarized and unpolarized positron beams, and doubling the beam energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Highly efficient photoelectric effect in halide perovskites for regenerative electron sources

Electron sources are a critical component in a wide range of applications such as electron-beam accelerator facilities, photomultipliers, and image intensifiers for night vision. We report efficient, regenerative and low-cost electron sources based on solution-processed halide perovskites thin films when they are excited with light with energy equal to or above their bandgap. We measure a quantum efficiency up to 2.2% and a lifetime of more than 25 h. Importantly, even after degradation, the electron emission can be completely regenerated to its maximum efficiency by deposition of a monolayer of Cs. The electron emission from halide perovskites can be tuned over the visible and ultraviolet spectrum, and operates at vacuum levels with pressures at least two-orders higher than in state-of-the-art semiconductor electron sources.

36 MATERIALS SCIENCE↗

Heavy-ion production of 77 Br and 76 Br

Many radioisotopes with potential medical applications are difficult to produce routinely, especially those on the proton-rich side of the valley of stability. Current production methods typically use light-ion (protons or deuteron) reactions on materials of similar mass to the target radioisotope, which limits the elemental target material available and may require the use of targets with poor thermal properties (as is the case for the production of radiobromine). These reactions may also create significant amounts of proton-rich decay products which require chemical separation from the desired product in a highly radioactive environment. A promising alternative method using heavy-ion fusion-evaporation reactions for the production of the medically relevant bromine radioisotopes 76 Br (t 1/2 = 16.2 h) and 77 Br (t 1/2 = 57.0 h) is presented. Heavy-ion beams of 28 Si and 16 O were used to bombard natural chromium and copper targets just above the Coulomb barrier at the University of Notre Dame's Nuclear Science Laboratory to produce these bromine and precursor radioisotopes by fusion-evaporation reactions. Production yields for these reactions were measured and compared to PACE4 calculations. In addition to using more robust targets for irradiation, a simple physical–chemical separation method is proposed that will lead to very high radiopurity yields. A summary of accelerator facility requirements needed for routine production of these radioisotopes is also presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Heavy Photon Search (HPS) Software Environment

The Heavy Photon Search (HPS) is an experiment at the Thomas Jefferson National Accelerator Facility (JLab) designed to search for a hidden sector photon (A’) in fixed-target electro-production. It uses a silicon microstrip tracking and vertexing detector placed inside a dipole magnet to measure charged particle trajectories and a fast lead-tungstate crystal calorimeter located just downstream of the magnet to provide a trigger and to identify electromagnetic showers. The HPS experiment uses both invariant mass and secondary vertex signatures to search for the A’. The experimental collaboration is small and quite heterogeneous: it is composed of members of the nuclear physics as well as particle physics communities, from universities and national labs from around the US and Europe. Enabling such a disparate group to concentrate on the physics aspects of the experiment required that the software be easy to install and use, and having such limited manpower meant that existing solutions had to be exploited. HPS has successfully completed two engineering runs and completed its first physics run in the summer of 2019. We begin with an overview of the physics goals of the experiment followed by a short description of the detector design. We then describe the software tools used to design the detector layout and simulate the expected detector performance. Event reconstruction involving track, cluster and vertex finding and fitting for both simulated and real data was, to first order, adopted from existing software originally developed for Linear Collider studies. Bringing it all together into a cohesive whole involved the use of multiple software solutions with common interfaces.

Graf, Norman↗

High-intensity polarized electron gun featuring distributed Bragg reflector GaAs photocathode

The polarized electron source is a critical component in accelerator facilities such as the electron–ion collider, which requires a polarized electron gun with higher voltage and higher bunch charge than existing sources. One challenge we faced was the surface charge limit of the distributed Bragg reflector GaAs/GaAsP superlattice (DBR-SL-GaAs) photocathode. We suppressed this effect by optimizing the surface doping and heat cleaning procedures. We achieved up to 11.6 nC bunch charge of polarized electron beam. In this report, we discuss the performance of tests of a DBR-SL-GaAs photocathode in the high voltage direct current gun. Possible reasons for the observed peak quantum efficiency wavelength shift are analyzed, and we addressed it by using a wavelength tunable laser. In addition, the impact of the DBR layer and laser on the lifetime is investigated in this paper. The optimal DBR-SL-GaAs operating zone has been proposed, which gave us a long lifetime and high polarization at 30 μA operation. Finally, the success of this polarized gun will be key to the future of the nuclear sciences.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark of Neutron Thermalization in Graphite Using a Pulsed Slowing-Down-Time Experiment

A benchmark has been developed using a pulsed slowing-down-time experiment to isolate the thermalization process in graphite. The experiment was conducted at the Oak Ridge Electron Linear Accelerator facility at Oak Ridge National Laboratory, and it measured the time spectrum of neutrons leaking from a graphite pile during slowing down and thermalization within graphite. Simulations of the benchmark experiment were performed using the MCNP6.1 Monte Carlo code and the ENDF/B-VII.1 and ENDF/B-VIII.0 cross-section databases. The benchmark provides a time spectrum (i.e., time-dependent counts in a detector) that allows for validation of the graphite thermal scattering libraries (TSLs). The impact on the simulations using a suite of graphite TSLs was compared with the experimental results. Given the density of nuclear graphite, the TSL corresponding to graphite with 30% porosity, as implemented in ENDF/B-VIII.0, was found to most accurately represent the measured time spectrum corresponding to the thermal energy range with an average deviation of ±1.7%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photonuclear Production of 67 Cu From Gallium

Copper-67 is a radioisotope of interest for medical imaging and therapy as well as for under- standing stellar and interstellar evolution pertaining to the formation of proton-rich nuclei. Since 67 Cu decays 100% to 67 Zinc, understanding this reaction can shed light on the abundance of this and other p-nuclei elements in the universe. Here, the photonuclear production of 67 Cu from 71 Ga and natural gallium is examined as an alternative to its photoproduction from zinc. Two research and development production runs were performed at Thomas Jefferson National Accelerator Facility using an electron linac. During the first run, an 805-W, 30.9-MeV beam was used to irradiate a 1-mm tungsten radiator to create a bremsstrahlung flux. The resulting gamma photons irradiated 50.9 g of natural gallium encased in a graphite crucible for 24.2 h; 7.02 Bq/W∙s∙kg of 67 Cu activity was produced. During the second run, a 4380-W, 31.5-MeV beam was used for 12.0 h on the same target containing 60 g of natural gallium; 6.41 Bq/W∙s∙kg of 67 Cu activity was produced. Because of the difficulties in spectroscopically differentiating 67 Cu from 67 Ga, prior to each run, an isotopically pure 71 Ga disk was irradiated using a 100-W beam for 1 h, at the same respective energies. Finally, these baseline irradiations allowed for separation of 67 Cu from 67 Ga in the spectroscopic measurements of the natural gallium targets.

07 ISOTOPE AND RADIATION SOURCES↗

The solenoidal large intensity device (SoLID) for JLab 12 GeV

The solenoidal large intensity device (SoLID) is a new experimental apparatus planned for Hall A at the Thomas Jefferson National Accelerator Facility (JLab). SoLID will combine large angular and momentum acceptance with the capability to handle very high data rates at high luminosity. With a slate of approved high-impact physics experiments, SoLID will push JLab to a new limit at the QCD intensity frontier that will exploit the full potential of its 12 GeV electron beam. In this paper, we present an overview of the rich physics program that can be realized with SoLID, which encompasses the tomography of the nucleon in 3D momentum space from semi-inclusive deep inelastic scattering, expanding the phase space in the search for new physics and novel hadronic effects in parity-violating DIS, a precision measurement of J/ψ production at threshold that probes the gluon field and its contribution to the proton mass, tomography of the nucleon in combined coordinate and momentum space with deep exclusive reactions, and more. To meet the challenging requirements, the design of SoLID described here takes full advantage of recent progress in detector, data acquisition and computing technologies. In addition, we outline potential experiments beyond the currently approved program and discuss the physics that could be explored should upgrades of CEBAF become a reality in the future.

3D imaging↗

Imaging and dosimetric characteristics of 67 Cu

In recent years the use of beta-emitting radiopharmaceuticals for cancer therapy has expanded rapidly following development of therapeutics for neuroendocrine tumors, prostate cancer, and other oncologic malignancies. One emerging beta-emitting radioisotope of interest for therapy is 67 Cu (t 1/2 : 2.6 d) due to its chemical equivalency with the widely-established positron-emitting isotope 64 Cu (t 1/2 : 12.7 h). Here we evaluate both the imaging and dosimetric characteristics of 67 Cu, as well as producing the first report of SPECT/CT imaging using 67 Cu. To this end, 67 Cu was produced by photon-induced reactions on isotopically-enriched 68 Zn at the Low-Energy Accelerator Facility (LEAF) of Argonne National Laboratory, followed by bulk separation of metallic 68 Zn by sublimation and radiochemical purification by column chromatography. Gamma spectrometry was performed by efficiency-calibrated high-purity germanium (HPGe) analysis to verify absolute activity calibration and establish radionuclidic purity. Absolute activity measurements corroborated manufacturer-recommended dose-calibrator settings and no radionuclidic impurities were observed. Using the Clinical Trials Network anthropomorphic chest phantom, SPECT/CT images were acquired. Medium Energy (ME) SPECT collimation was found to provide the best image quality from the primary 185 keV gamma emission of 67 Cu. Reconstructed images of 67 Cu were similar in quality to images acquired using 177 Lu. Recovery coefficients were calculated and compared against quantitative images of 99m Tc, 177 Lu, and 64 Cu within the same anthropomorphic chest phantom. Production and clinical imaging of 67 Cu appears feasible, and future studies investigating the therapeutic efficacy of 67 Cu-based radiopharmaceuticals are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a direct-sampling RF receiver for precision beam charge measurements in the MOLLER experiment

Here, we have developed and tested a direct-sampling RF receiver capable of measuring the amplitude of a 1497 MHz sinusoidal beam signal in 0.5 ms integration windows with a relative uncertainty of better than 10 parts per million. The receiver is intended for measuring signals from beam current monitoring cavities on the beamline of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. The beam signal strength, frequency, and integration window fulfill the thus far unmet requirements of the upcoming MOLLER experiment to measure the beam charge for different helicity states.

47 OTHER INSTRUMENTATION↗

Performance of a coarsely pixelated LAPPD photosensor for the SoLID gas Cherenkov detectors

The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed across 32 sectors, to serve the light-gas and heavy-gas Cherenkov counters, respectively. To assess the viability of a pixelated INCOM Large Area Picosecond Photodetector (LAPPD TM ) as an alternative photosensor to replace MaPMT arrays in either detector, we evaluated its performance under realistic SoLID running conditions in Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The results of this test confirmed that the coarse-pixelated (2.5 × 2.5 cm 2 pixel size) LAPPD is capable of handling the total projected signal and background rates of the three pillar SoLID experiments. The tested photosensor detected Cherenkov signals with the capability of separating single-electron events from pair production events while rejecting background. Although the design was not aimed at ring-imaging Cherenkov detectors, Cherenkov disk images were captured in two different gas radiators. Through a direct comparison with a GEANT4 simulation, we confirmed the experimental performance of the LAPPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of a replacement subatmospheric cold box for Jefferson Lab’s Central Helium Liquefier

Jefferson Lab’s Cryogenics Department has designed, fabricated, installed, and commissioned a new subatmospheric cold box to replace one of the two existing units within our Central Helium Liquefier (CHL). The replacement cold box, dubbed SC1R, pumps saturated helium vapor at 0.0385 atm from Jefferson Lab’s continuous electron beam accelerator facility (CEBAF) cryomodules to maintain an operating temperature of nominally 2.1 K. This is accomplished using a five-stage cryogenic centrifugal compressor (cold compressor) system and a brazed aluminum plate-fin heat exchanger operating between 2.1 K and 4.5 K. In this paper we will describe our experience commissioning the SC1R cold box. We will discuss pump-down of the system to 2.1 K and steady-state operation at the cold compressor design flow rates of 170, 200, and 250 g/s. Performance of the heat exchanger and cold compressors has been mapped across a range of flow rates and optimized for CEBAF operations. This commissioning data will be used to monitor future performance and adapt to changing load requirements.

Mastracci, B.↗

Neutron-Resonance Transmission Analysis with a Compact Deuterium-Tritium Neutron Generator

Neutron Resonance Transmission Analysis (NRTA) is a spectroscopic technique which uses the resonant absorption of neutrons in the epithermal range to infer the isotopic composition of an object. This spectroscopic technique has relevance in many traditional fields of science and nuclear security. NRTA in the past made use of large, expensive accelerator facilities to achieve precise neutron beams, significantly limiting its applicability. Here, we describe a series of NRTA experiments where we use a compact, low-cost deuterium-tritium (DT) neutron generator to produce short neutron beams (2.6 m) along with a 6 Li-glass neutron detector. The time-of-flight spectral data from five elements – silver, cadmium, tungsten, indium, and 238 U – clearly show the corresponding absorption lines in the 1-30 eV range. The experiments show the applicability of NRTA in this simplified configuration, and prove the feasibility of this compact and low-cost approach. This could significantly broaden the applicability of NRTA, and make it practical and applicable in many fields, such as material science, nuclear engineering, and arms control.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First measurement of direct photoproduction of the a 2 (1320) 0 meson on the proton

We present the first measurement of the reaction γ p → a 2 ( 1320 ) 0 p in the photon energy range 3.5– 5.5 Ge V and four-momentum transfer squared 0.2 < - t < 2.0 Ge V 2 . Data were collected with the CEBAF Large Acceptance Spectrometer detector at the Thomas Jefferson National Accelerator Facility. The a 2 resonance was detected by measuring the reaction γ p → π 0 η p and reconstructing the π 0 η invariant mass. The most prominent feature of the differential cross section is a dip at -t ≈ 0.55 Ge V 2 . This can be described in the framework of Regge phenomenology, where the exchange degeneracy hypothesis predicts a zero in the reaction amplitude for this value of the four-momentum transfer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stellar s-process neutron capture cross sections on 78,80,84,86 Kr determined via activation, atom trap trace analysis and decay counting

We present a detailed account of neutron capture experiments of astrophysical relevance on 78,80,84,86 Kr (n, γ) reactions at the border between weak and main s process. The experiments were performed with quasi-Maxwellian neutrons from the Liquid-Lithium Target (LiLiT) and the mA-proton beam at 1.93 MeV (2-3 kW) of the Soreq Applied Research Accelerator Facility (SARAF). The setup yields high-intensity approximate to 40 keV quasi-Maxwellian neutrons (3-5 x10 10 n/s) closely reproducing the conditions of s-process stellar nucleosynthesis. A sample of 100 mg of atmospheric, pre-nuclear-age Kr gas contained in a Ti spherical shell was activated in the LiLiT neutron field. The abundances of long-lived Kr isotopes ( 81,85g Kr) were measured by atom counting via atom trap trace analysis (ATTA) at Argonne National Laboratory and low-level counting (LLC) at University of Bern. This work is the first measurement of a nuclear cross section using atom counting via ATTA. The activities of short-lived Kr isotopes ( 79,85m,87 Kr) were measured by gamma-decay counting with a high-purity germanium detector. Maxwellian-averaged cross sections for s-process thermal energies are extracted. By comparison to reference values, our nucleosynthesis network calculations show that the experimental cross sections have a strong impact on calculated abundances of krypton and neighboring nuclides, in some cases improving agreement between theory and observations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the EMC effect in light and heavy nuclei

In this work, inclusive electron scattering from nuclear targets has been measured to extract the nuclear dependence of the inelastic cross section in Hall C at the Thomas Jefferson National Accelerator facility. Results are presented for 2 H, 3 He, 4 He, 9 B, 12 C, 63 Cu and 197 Au at an incident electron beam energy of 5.77 GeV for a range of momentum transfer from Q 2 = 2 to 7 (GeV/c) 2 . These data improve the precision of the existing measurements of the EMC effect in the nuclear targets at large x, and allow for more detailed examinations of the A dependence of the EMC effect.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗