Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerator Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Towards Automated Generation of Chiplet-Based Systems

The Software Defined Architectures (SODA) Synthesizer is an open-source compiler-based tool able to automatically generate domain-specialized systems targeting Application- Specific Integrated Circuits (ASICs) or Field Programmable Gate Arrays (FPGAs) starting from high-level programming. SODA is composed of a high-level frontend, SODA-OPT, which leverages the multilevel intermediate representation (MLIR) framework to interface with productive programming tools (e.g., machine learning frameworks), identify kernels suitable for acceleration, and perform high-level optimizations, and of a state-of-the-art high-level synthesis backend, Bambu from the PandA framework, to generate custom accelerators. One specific application of the SODA Synthesizer is the generation of accelerators to enable ultra-low latency inference and control on autonomous systems for scientific discovery (e.g., electron microscopes, sensors in particle accelerators, etc.). This talk will discuss ongoing work on the SODA synthesizer to enable no-human-in-the-loop generation and design space exploration of the chiplets for highly specialized artificial intelligence accelerators. Connecting these highly specialized chiplets to general-purpose cores or programmable accelerators will allow to quickly deploy autonomous systems for scientific discovery.

Limaye, Ankur M.↗

Operation at Reduced Atmospheric Pressure and Concept of Reliability Redundancy for Optimized Design of Insulation Systems

Electrified transportation is calling for insulation design criteria that is adequate to provide elevated levels of power density, power dynamics and reliability. Increasing voltage levels are expected to cause accelerated intrinsic and extrinsic aging effects which will not be easily predictable at the design stage due to a lack of suitable modeling. Designing reliable insulation systems would require finding solutions able to control accelerated aging due to an unpredictable increase of intrinsic stresses and the onset of extrinsic stresses as partial discharges. This paper proposes the concept of reliability redundancy for the insulation design of aerospace electrical asset components, which is also validated at lower-than-standard atmospheric pressure. The principle is that extrinsic-aging-free design might be achieved upon determining the aging stress or abnormal service stresses distribution and being sure that aging will not generate conditions that can incept extrinsic aging (partial discharges) during operation life. However, such information is never, in practice, fully available to insulation system designers. Hence, especially in critical applications such as electrified aircraft, aerospace, and combat ships a further level of reliability should be added to a partial-discharge-free design, which can consist of the use of corona-resistant materials and/or of life models able to consider the accelerated aging effect of partial discharges (or any other type of extrinsic-accelerated aging factor). Innovative life modeling considering both extrinsic and intrinsic aging stresses, insulating material testing to estimate model parameters, and a metric for quantifying the extent of corona (or partial discharge) resistance can lead to establishing feasibility and limit conditions for optimized or fully reliability-redundant design. It is shown in the paper that if an extrinsic-aging-free design is not feasible, and it is therefore replaced by a redundant design, a further level of reliability redundancy can be provided by effective condition monitoring plans.

Montanari, Gian Carlo↗

A Data Science and Machine Learning Platform Supporting Large Particle Accelerator Control and Diagnostics Applications Final Report: SBIR Initial Phase II DE-SC0022583

The Machine Learning Data Platform (MLDP) is a product providing full-stack support for data science, Machine Learning, and Artificial Intelligence (ML/AI) applications at particle accelerator and large experimental physics facilities. It supports ML/AI applications from front-end, high-speed acquisition of heterogeneous, time-series data, through data archiving and management, to back-end analysis. The MLDP embodies a “data-science ready” platform for data analysis and ML/AI applications in diagnosis, modelling, control, and optimization of these facilities. It provides data scientists and applications a consistent, datacentric interface to archive data standardizing implementation and deployment of ML/AI algorithms to different operations configurations within the same facility, or between facilities. Being an open-source, public-domain project, the MLDP is intended for broadest possible impact by increasing accessibility and minimizing the required expertise for installation and operation. The MLDP can also be deployed at user facilities for experimental data collection, archiving, and analysis. It is capable of acquisition and archiving of heterogeneous data from experimental equipment (e.g., images, arrays, structures, etc.) along with system hardware configurations (e.g., scalars, tables), control system process variables, and any metadata required for provenance. Thus, the MLDP can manage experimental data through its entire lifecycle, from acquisition and archiving, through analysis and investigation, to release and final publication.

43 PARTICLE ACCELERATORS↗

Resonance Control System for the CEBAF Separator Upgrade

Abstract The Continuous Electron Beam Accelerator Facility (CEBAF) energy upgrade from 6 GeV to 12 GeV includes the installation of four new 748.5 MHz normal conducting deflecting cavities in the 5th pass extraction region. The RF system employs two digital LLRF systems controlling four normal conducting cavities in a vector sum setting. Cavity tune information of the individual cavities is obtained using a multiplexing scheme of the forward and reflected RF signals. Water skids equipped with heaters and valves are used to control resonance. A new FPGA-based hardware and EPICS-based predictive control algorithm has been developed to support reliable operation of the beam extraction process. This paper presents the architecture design of the existing hardware and software as well as a plan to develop a model predictive control system.

Plawski, Tomasz↗

Features Of The J-PARC Linac

Japan Proton Accelerator Research Complex (J-PARC) will be one of the highest intensity proton accelerators in the world aiming to realize 1 MW class of the beam power. The accelerator consists of a 400-MeV linac, a 3-GeV rapid-cycling synchrotron (RCS) and a main ring synchrotron (MR), and the accelerated beam is applied to several experimental facilities. The linac, which is the injector for the RCS, has about 50 cavity modules to accelerate the beam up to 400 MeV. The acceleration field error in all of them should be within {+-}1% in amplitude and {+-}1 degree in phase because the momentum spread of the RCS injection beam is required to be within 0.1%. For the cavity field stabilization, a high-stable optical signal distribution system is used as the RF reference, and sophisticated digital feedback and feed-forward system is working well in the low level RF control system. Consequently the providing beam to the RCS is very stable, and the beam commissioning and the experiments of the application facilities have been progressed steadily.

43 PARTICLE ACCELERATORS↗

Re-visit local coupling correction in the interaction regions of RHIC

In this article we will re-visit the local coupling correction in the interaction regions (IRs) of the Relativistic Heavy Ion Collider (RHIC). We will review the measurement data of triplet quadrupole rolls, the local coupling correction strengths in the RHIC control system, and the methods for the local coupling correction with local skew quadrupole correctors. Based on the in-turnnel measurement data of triplet roll errors in 2011, we will analytically calculate and simulate IR-bump method to find out the local skew correction strengths and compare them at store and at injection with the Blue and Yellow ring lattices in the 2011 polarized proton (p-p) and Au-Au runs. The vertical dispersion from the triplet roll errors, local and global coupling correction skew quadrupoles, and the vertical dipole correctors are calculated and discussed.

43 PARTICLE ACCELERATORS↗

Performance of the LLRF System for the Fermilab PIP-II Injector Test

PIP-II IT is a test facility for the PIP-II project where the injector, warm front-end, and the first two superconducting cryomodules are being tested. The 8-cavity half-wave-resonator (HWR) cryomodule operating at 162.5 MHz is followed by the 8-cavity single-spoke resonator(SSR1) cryomodule operating at 325 MHz. The LLRF systems for both cryomodules are based on a common SOC FPGA-based hardware platform. The resonance control systems for the two cryomodules are quite different, the first being a pneumatic system based on helium pressure and the latter a piezo/stepper motor type control. The data acquisition and control system can support both CW and Pulsed mode operations. Beam loading compensation is available which can be used for both manual/automatic control in the LLRF system. The user interfaces include EPICS, Labview, and ACNET. Testing of the RF system has progressed to the point of being ready for a 2 mA beam to be accelerated to 25 MeV. The design and performance of the field control and resonance control system operation with beam are presented in this paper.

43 PARTICLE ACCELERATORS↗

RHIC PERFORMANCE DURING THE FY10 200 GeV Au+Au HEAVY ION RUN

Since the last successful RHIC Au+Au run in 2007 (Run-7), the RHIC experiments have made numerous detector improvements and upgrades. In order to benefit from the enhanced detector capabilities and to increase the yield of rare events in the acquired heavy ion data a significant increase in luminosity is essential. In Run-7 RHIC achieved an average store luminosity of <L> = 12 x 10{sup 26} cm{sup -2} s{sup -1} by operating with 103 bunches (out of 111 possible), and by squeezing to {beta}* = 0.85 m. This year, Run-10, we achieved <L> = 20 x 10{sup 26} cm{sup -2} s{sup -1}, which put us an order of magnitude above the RHIC design luminosity. To reach these luminosity levels we decreased {beta}* to 0.75 m, operated with 111 bunches per ring, and reduced longitudinal and transverse emittances by means of bunched-beam stochastic cooling. In addition we introduced a lattice to suppress intra-beam scattering (IBS) in both RHIC rings, upgraded the RF control system, and separated transition crossing times in the two rings. We present an overview of the changes and the results of Run-10 performance.

43 PARTICLE ACCELERATORS↗

SU-E-T-495: Neutron Induced Electronics Failure Rate Analysis for a Single Room Proton Accelerator

Purpose: To determine the failure rate as a function of neutron dose of the range modulator's servo motor controller system (SMCS) while shielded with Borated Polyethylene (BPE) and unshielded in a single room proton accelerator. Methods: Two experimental setups were constructed using two servo motor controllers and two motors. Each SMCS was then placed 30 cm from the end of the plugged proton accelerator applicator. The motor was then turned on and observed from outside of the vault while being irradiated to known neutron doses determined from bubble detector measurements. Anytime the motor deviated from the programmed motion a failure was recorded along with the delivered dose. The experiment was repeated using 9 cm of BPE shielding surrounding the SMCS. Results: Ten SMCS failures were recorded in each experiment. The dose per monitor unit for the unshielded SMCS was 0.0211 mSv/MU and 0.0144 mSv/MU for the shielded SMCS. The mean dose to produce a failure for the unshielded SMCS was 63.5 ± 58.3 mSv versus 17.0 ±12.2 mSv for the shielded. The mean number of MUs between failures were 2297 ± 1891 MU for the unshielded SMCS and 2122 ± 1523 MU for the shielded. A Wilcoxon Signed Ranked test showed the dose between failures were significantly different (P value = 0.044) while the number of MUs between failures were not (P value = 1.000). Statistical analysis determined a SMCS neutron dose of 5.3 mSv produces a 5% chance of failure. Depending on the workload and location of the SMCS, this failure rate could impede clinical workflow. Conclusion: BPE shielding was shown to not reduce the average failure of the SMCS and relocation of the system outside of the accelerator vault was required to lower the failure rate enough to avoid impeding clinical work flow.

07 ISOTOPE AND RADIATION SOURCES↗

Neural networks for modeling and control of particle accelerators

Charged particle accelerators support a wide variety of scientific, industrial, and medical applications. They range in scale and complexity from systems with just a few components for beam acceleration and manipulation, to large scientific user facilities that span many kilometers and have hundreds-to-thousands of individually-controllable components. Specific operational requirements must be met by adjusting the many controllable variables of the accelerator. Meeting these requirements can be challenging, both in terms of the ability to achieve specific beam quality metrics in a reliable fashion and in terms of the time needed to set up and maintain the optimal operating conditions. One avenue toward addressing this challenge is to incorporate techniques from the fields of machine learning (ML) and artificial intelligence (AI) into the way particle accelerators are modeled and controlled. While many promising approaches within AI/ML could be used for particle accelerators, this dissertation focuses on approaches based on neural networks. Neural networks are particularly well-suited to modeling, control, and diagnostic analysis of nonlinear systems, as well as systems with large parameter spaces. They are also very appealing for their ability to process high-dimensional data types, such as images and time series (both of which are ubiquitous in particle accelerators). In this work, key studies that demonstrated the potential utility of modern neural network-based approaches to modeling and control of particle accelerators are presented. The context for this work is important: at the start of this work in 2012, there was little interest in AI/ML in the particle accelerator community, and many of the advances in neural networks and deep learning that enabled its present success had not yet been made at that time. As such, this work was both an exploration of possible application areas and a generator of proof-of-concept demonstrations in these areas.

43 PARTICLE ACCELERATORS↗

Development and Application of the STARS-based Beamline Control System at the Photon Factory

STARS{sup [1-2]}(Simple Transmission and Retrieval System) is a message transferring software for small-scale control systems with TCP/IP sockets, originally developed at the Photon Factory (PF). Because it has a server-client architecture using TCP/IP sockets and can work on various types of operating systems, the design and application are quite flexible. We have developed a common low-level beamline control system based on the STARS technology. Many kinds of useful STARS clients (device drivers, data acquisitions, user interfaces etc.) are available now, and so far, the system has been installed at 22 PF beamlines. We will describe the development and generalize of the STARS-based beamline control system at the PF.

43 PARTICLE ACCELERATORS↗

I. Final Report for DOE SBIR Phase I Project DE-SC0013795 Final Report for DOE SBIR Phase I Project DE-SC0013795 Microtron-based Compact, Portable Gamma-Ray Source

Microtron-based Compact, Portable Gamma-Ray Source. The objective of Phase I of this project was to produce a conceptual design of a prototype compact microtron electron accelerator, which could be designed, built, and demonstrated in Phase II of the project. The conceptual design study included an analysis of the parameters of the microtron and its components, and the expected performance of the prototype microtron as a source of x-rays and/or RF neutrons in the MeV energy range. The major components of the microtron are the magnet, the accelerating system, the power system, the vacuum system, the control system, the beam extraction system and the targets to produce x-rays (and/or neutrons). Our objectives for the design of the prototype were for it to be compact, cost-effective, capable of producing high intensity x-ray (an/or neutron) fluxes. In addition, the prototype was to be easily assembled and disassembled so that components could be easily replaced. The main parameters for the prototype are the following: the range of electron kinetic energies, the output power, the RF frequency band (X-band, C-band, or S-Band), the type of injection (Type I or Type II), the magnet type, i.e. permanent magnet, electromagnet, or a hybrid combination of permanent and electromagnet. The results of the Phase I study and analysis for a prototype microtron are the following: The electron energy range can be varied from below 6 MeV to 9 MeV, the optimal frequency range is S-Band (2-4 GHz) RF frequency, Type II injection (described below), and the magnet type is the hybrid version. The prototype version will be capable of producing gamma ray doses of ~1800 R/min-m and neutron fluxes of up to ~6 x 10 10 n/s with appropriate targets. The results of the Phase I study and analysis are provided below. The proposed Phase II plan was to demonstrate the prototype at low beam power. In the subsequent Phase III, high power tests would be performed, and the design of commercial versions of microtrons with various energies, sizes and types would be produced and marketed, including a more compact and more portable 6 MeV battery-powered model that more closely meets the requirements in the original FOA topic description. In the course of the Phase I study, we also identified another microtron version, one that was larger (not compact) and more powerful than that of the Phase II prototype, which could serve as an intense source of photo- neutrons, up to 4 x 10 12 n/s for use in nuclear medicine, short-lived isotope production, or other applications. In addition, it could produce gamma dose rates up to 130 kR/min-m with a heavy metal bremsstrahlung target. The results and specifications of this were submitted to IPAC16 (Reference [12]) the paper is included in Addendum B. Because this version was beyond the scope of the Phase I project, there is no additional description in the Final Report.

43 PARTICLE ACCELERATORS↗

The Continuous Electron Beam Accelerator Facility at 12 GeV

This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of 20 MV / m . After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Machine learning-enabled prediction of chemical durability of A 2 B 2 O 7 pyrochlore and fluorite

Pyrochlore-structure type and its derivative in a general formula A 2 B 2 O 7 (A = rare earth elements and actinides; B = Ti, Sn, Zr, Hf, Pb, Si, etc.) display excellent structural flexibility and rich crystal chemistry as promising nuclear waste form materials capable of immobilizing actinides and fission products. It is essential to understand these materials’ chemical durability and element release of radionuclides in order to evaluate their performance in near-field environment. However, it is a formidable grand technological challenge to experimentally perform durability testing across hundreds of thousands of possibilities resulting from their extreme compositional complexities due to cation substitutions at both A and B-sites. In this work, we demonstrate a machine learning approach to determine the key materials parameters and structural characteristics governing the leaching behaviors from a small set of selected compositions as model systems, enabling a science-based prediction of their chemical durability that can be extended to a wide range of chemical compositions. The combination of four key structural characteristics and materials parameters, including ionic radius size difference , ionic potential difference , electronegativity difference , and lattice parameter , creates features an optimized prediction of the chemical durability. Two machine learning models, linear regression and Kernel ridge regression models, are trained on the randomly-split training dataset derived from the experimentally-determined elemental release rates, and subsequently tested on the testing dataset. The predicted leaching rates from both machine learning models show an excellent agreement with the experimental data, demonstrating the feasibility of rapidly evaluating the material properties of new compositions. These results highlight the immense potential of synergizing informatics through machine learning-based models and well-controlled experiments of selected model systems to accelerate materials design and discovery with optimized compositions and performance of promising materials for effective nuclear waste management.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TH-EF-204-00: AAPM-AMPR (Russia)-SEFM (Spain) Joint Course On Challenges and Advantages of Small Field Radiation Treatment Techniques

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.

60 APPLIED LIFE SCIENCES↗

TH-EF-204-01: Introduction

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.

60 APPLIED LIFE SCIENCES↗