Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ablator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

FDG-MicroPET and Diffusion-Weighted MR Image Evaluation of Early Changes After Radiofrequency Ablation in Implanted VX2 Tumors in Rabbits

The objective of this study was to evaluate the early changes after radiofrequency ablation (RFA) in VX2 rabbit tumors implanted into the back muscles by diffusion-weighted magnetic resonance (MR) imaging and {sup 18}F-2-fluoro-2-deoxy-D-glucose positron emission tomography ({sup 18}F-FDG PET). Percutaneous CT-guided RFA was conducted in seven rabbits with implanted VX2 tumors. VX2 tumors on the other side were untreated and served as the control. MR imaging was performed with a clinical 1.5-T instrument 2 days after RFA, and FDG-PET, using a high-resolution PET scanner for small animals, was obtained 3 days after the procedure. The mean apparent diffusion coefficient (ADC) values and radioactivity count of untreated and ablated tumors were calculated. Untreated VX2 tumors showed hyperintensity on T1-, T2-, and diffusion-weighted MR images, ring-enhanced on contrast-enhanced T1-weighted imaging, and ring-shaped FDG accumulation on FDG-PET. Ablated VX2 tumors showed slight hyperintensity on T1-, T2-, and diffusion-weighed images, slight enhancement on contrast-enhanced T1-weighted images, and low accumulation on FDG-PET. The ADC value of ablated VX2 tumors (1.52 {+-} 0.24 x 10{sup -3} mm{sup 2}/s) was significantly higher than that of untreated tumors (1.09 {+-} 0.12 x 10{sup -3}; p < 0.05). The tumor/muscle ratio of ablated tumors (0.5 {+-} 0.3) was significantly lower than that of untreated tumors (11.6 {+-} 3.2; p < 0.05). Histopathological examination confirmed the lack of viable tumor cells in the ablated lesions. The results indicate that both ADC value and FDG-PET are potentially useful markers for monitoring the early effects of RFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave Ablation of Pulmonary Malignancies Using a Novel High-energy Antenna System

To evaluate the technical success, safety, and imaging follow-up of malignant pulmonary nodules treated with a novel high-energy percutaneous microwave ablation (MWA) system. Between July 2010 and September 2011, a total of 23 patients, 12 men, mean age 68 (range 30-87) years with 29 pulmonary malignancies of median diameter 19 (range 8-57) mm, underwent computed tomography (CT)-guided MWA with a 16G microwave needle antenna enabling power up to 180 W. Technical success was defined as needle placement in the intended lesion without death or serious injury. Adequacy of ablation was assessed at 24 h on contrast-enhanced CT. Circumferential solid or ground glass opacification >5 mm was used to define an ideal ablation. Local tumor recurrence was assessed at 1, 3, and 6 months after ablation on contrast-enhanced CT. MWA was technically successful in 93 % (n = 27). Mean ablation duration was 3.6 (range 1-9) min. Ten patients (43 %) developed a pneumothorax as a result of the MWA; only 3 (13 %) required placement of a chest drain. Thirty-day mortality rate was 0 %. The mean hospital stay was 1.5 (range 1-7) days. A total of 22 lesions (75 %) were surrounded by {>=}5 mm ground glass or solid opacification after the procedure. At a median follow-up of 6 months, local recurrence was identified in 3 out of 26 lesions, giving a local control rate of 88 %. MWA using a high-power antenna of pulmonary malignancies is safe, technically achievable, and enables fast ablation times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging Features of Radiofrequency Ablation with Heat-Deployed Liposomal Doxorubicin in Hepatic Tumors

IntroductionThe imaging features of unresectable hepatic malignancies in patients who underwent radiofrequency ablation (RFA) in combination with lyso-thermosensitive liposomal doxorubicin (LTLD) were determined.Materials and MethodsA phase I dose escalation study combining RFA with LTLD was performed with peri- and post- procedural CT and MRI. Imaging features were analyzed and measured in terms of ablative zone size and surrounding penumbra size. The dynamic imaging appearance was described qualitatively immediately following the procedure and at 1-month follow-up. The control group receiving liver RFA without LTLD was compared to the study group in terms of imaging features and post-ablative zone size dynamics at follow-up.ResultsPost-treatment scans of hepatic lesions treated with RFA and LTLD have distinctive imaging characteristics when compared to those treated with RFA alone. The addition of LTLD resulted in a regular or smooth enhancing rim on T1W MRI which often correlated with increased attenuation on CT. The LTLD-treated ablation zones were stable or enlarged at follow-up four weeks later in 69 % of study subjects as opposed to conventional RFA where the ablation zone underwent involution compared to imaging acquired immediately after the procedure.ConclusionThe imaging features following RFA with LTLD were different from those after standard RFA and can mimic residual or recurrent tumor. Knowledge of the subtle findings between the two groups can help avoid misinterpretation and proper identification of treatment failure in this setting. Increased size of the LTLD-treated ablation zone after RFA suggests the ongoing drug-induced biological effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ex Vivo Liver Experiment of Hydrochloric Acid-Infused and Saline-Infused Monopolar Radiofrequency Ablation: Better Outcomes in Temperature, Energy, and Coagulation

ObjectiveTo compare temperature, energy, and coagulation between hydrochloric acid-infused radiofrequency ablation (HAIRFA) and normal saline-infused radiofrequency ablation (NSIRFA) in ex vivo porcine liver model.Materials and Methods30 fresh porcine livers were excised in 60 lesions, 30 with HAIRFA and the other 30 with NSIRFA. Both modalities used monopolar perfusion electrode connected to a RF generator set at 103 °C and 30 W. In each group, ablation time was set at 10, 20, or 30 min (10 lesions from each group at each time). We compared tissue temperatures (at 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 cm away from the electrode tip), average power, deposited energy, deposited energy per coagulation volume (DEV), coagulation diameters, coagulative volume, and spherical ratio between the two groups.ResultsTemperature–time curves showed that HAIRFA provided progressively greater heating than that of NSIRFA. At 30 min, mean average power, deposited energy, coagulation volumes (113.67 vs. 12.28 cm{sup 3}) and diameters, and increasing in tissue temperature were much greater with HAIRFA (P < 0.001 for all), except DEV was lower (456 vs. 1396 J/cm{sup 3}, P < 0.001). The spherical ratio was closer to 1 with HAIRFA (1.23 vs. 1.46). Coagulation diameters, volume, and average power of HAIRFA increased significantly with longer ablation times. While with NSIRFA, these characteristics were stable till later 20 min, except the power decreased with longer ablation times.ConclusionsHAIRFA creates much larger and more spherical lesions by increasing overall energy deposition, modulating thermal conductivity, and transferring heat during ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Avoiding Complications in Bone and Soft Tissue Ablation

As with percutaneous ablation of tumors in the liver, lungs, and kidneys, ablation of bone and non-visceral soft tissue tumors carries risk, primarily from collateral damage to vital structures in proximity to the target tumor. Certain risks are of particular interest when ablating bone and non-visceral soft tissue tumors, namely neural or skin injury, bowel injury, fracture, and gas embolism from damaged applicators. Ablation of large volume tumors also carries special risk. Many techniques may be employed by the interventional radiologist to minimize complications when treating tumors in the musculoskeletal system. These methods include those to depict, displace, or monitor critical structures. Thus, measures to provide thermoprotection may be active, such as careful ablation applicator placement and use of various displacement techniques, as well as passive, including employment of direct temperature, radiographic, or neurophysiologic monitoring techniques. Cementoplasty should be considered in certain skeletal locations at risk of fracture. Patients treated with large volume tumors should be monitored for renal dysfunction and properly hydrated. Finally, ablation applicators should be cautiously placed in the constrained environment of intact bone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Dose and Risk Estimates of CT-Guided Percutaneous Liver Ablations and Factors Associated with Dose Reduction

PurposeTo determine the radiation dose associated with CT-guided percutaneous liver ablations and identify potential risk factors that result in higher radiation doses.Materials and MethodsBetween June 2011 and June 2015, 245 consecutive patients underwent 304 CT-guided liver ablation treatments. Patient demographics, tumor characteristics and procedural parameters were identified and analyzed. The peak skin dose and effective dose were assessed for each procedure. Excess relative risk related to radiation effects was calculated. A logistic regression model was prepared by means of stepwise logistic regression to identify variables predictive of increased radiation exposure.ResultsTumor ablations were performed with microwave (n = 220), radiofrequency (n = 74) or irreversible electroporation (IRE) (n = 10). The mean peak skin dose for ablations was 239.2 ± 136.4 mGy, and the mean effective dose was 36.6 ± 22.3 mSv. Of the patient and procedural parameters that were analyzed, increasing weight, use of intravenous contrast and/or hydrodissection during the procedure, together with treatment of multiple lesions in the same sitting were all associated with higher radiation exposure. The mean increase in the absolute risk of fatal malignancy from a single procedure was 0.18% (range 0.02–0.9%). No deterministic skin changes were identified in the patient cohort.ConclusionThe overall risk of stochastic and deterministic effects from radiation associated with CT-guided ablations is low compared with other inherent procedural complications. This study identifies several factors that are associated with higher radiation dose in percutaneous liver ablation procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vitro Bovine Liver Experiment of Cisplatin-Infused and Normal Saline-Infused Radiofrequency Ablation with an Internally Cooled Perfusion Electrode

Purpose: To evaluate the efficacy of cisplatin-infused and normal saline-infused radiofrequency ablation (RFA) with internally cooled perfusion (ICP) electrode. Materials and Methods: Using a 200 W generator, thirty ablation zones were created and divided into three groups of 10 each as follows: group A, RFA alone with 16 gauge monopolar internally cooled (IC) electrode; group B, cisplatin-infused RFA with 16 gauge ICP electrode; and group C, normal saline-infused RFA with 16 gauge ICP electrode. Radiofrequency was applied to the explanted bovine liver for 12 min. During RFA, cisplatin and normal saline were injected into tissue at a rate of 0.5 mL/min through the ICP electrode by injection pump. Dimensions of the ablation zone and technical parameters were compared between the three groups. Result: In the cisplatin-infused RFA group, the ablation zone size was significantly larger than that of the RFA-alone group but significantly smaller than normal saline-infused RFA group. The width of longitudinal section and volume were 3.39 ± 0.22 cm{sup 2} and 26.55 ± 4.62 cm{sup 3} in RFA-alone group, 3.88 ± 0.32 cm{sup 2} and 36.45 ± 5.46 cm{sup 3} in cisplatin-infused RFA group, and 4.52 ± 0.50 cm{sup 2} and 49.44 ± 7.55 cm{sup 3} in normal saline-infused RFA group, respectively (p < 0.05 between any two groups). The mean impedance in group A, B, and C were 60.0 ± 7.2, 50.3 ± 2.5, and 40.3 ± 4.0 Ω, respectively (p < 0.05 between any two groups). Conclusion: Cisplatin-infused RFA with ICP electrode created the larger size of ablation zone than that of monopolar RFA with an IC electrode, but created the smaller size of ablation zone than that of normal saline-infused RFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High resolution selective multilayer laser processing by nanosecond laser ablation of metal nanoparticle films

Ablation of gold nanoparticle films on polymer was explored using a nanosecond pulsed laser, with the goal to achieve feature size reduction and functionality not amenable with inkjet printing. The ablation threshold fluence for the unsintered nanoparticle deposit was at least ten times lower than the reported threshold for the bulk film. This could be explained by the combined effects of melting temperature depression, lower conductive heat transfer loss, strong absorption of the incident laser beam, and the relatively weak bonding between nanoparticles. The ablation physics were verified by the nanoparticle sintering characterization, ablation threshold measurement, time resolved ablation plume shadowgraphs, analysis of ablation ejecta, and the measurement and calculation of optical properties. High resolution and clean feature fabrication with small energy and selective multilayer processing are demonstrated.

36 MATERIALS SCIENCE↗

Spectroscopic diagnostics for ablation cloud of tracer-encapsulated solid pellet in LHD

In the Large Helical Device (LHD), various spectroscopic diagnostics have been applied to study the ablation process of an advanced impurity pellet, tracer-encapsulated solid pellet (TESPEL). The total light emission from the ablation cloud of TESPEL is measured by photomultipliers equipped with individual interference filters, which provide information about the TESPEL penetration depth. The spectra emitted from the TESPEL ablation cloud are measured with a 250 mm Czerny-Turner spectrometer equipped with an intensified charge coupled device detector, which is operated in the fast kinetic mode. This diagnostic allows us to evaluate the temporal evolution of the electron density in the TESPEL ablation cloud. In order to gain information about the spatial distribution of the cloud parameters, a nine image optical system that can simultaneously acquire nine images of the TESPEL ablation cloud has recently been developed. Several images of the TESPEL ablation cloud in different spectral domains will give us the spatial distribution of the TESPEL cloud density and temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental scaling law for mass ablation rate from a Sn plasma generated by a 1064 nm laser

The ablation depth in planar Sn targets irradiated with a pulsed 1064 nm laser was investigated over laser intensities from 3x10{sup 11} to 2x10{sup 12} W/cm{sup 2}. The ablation depth was measured by irradiating a thin layer of Sn evaporated onto a Si wafer, and looking for signatures of Si ions in the expanding plasma with spectroscopic and particle diagnostics. It was found that ablation depth scales with laser intensity to the (5/9)th power, which is consistent with analytical models of steady-state laser ablation, as well as empirical formulae from previous studies of mass ablation rate in overlapping parameter space. In addition, the scaling of mass ablation rate with atomic number of the target as given by empirical formulae in previous studies using targets such as C and Al, are shown to remain valid for the higher atomic number of the target (Z=50) used in these experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics of the plumes produced by ultrafast laser ablation of metals

We have analyzed ultrafast laser ablation of a metallic target (Nickel) in high vacuum addressing both expansion dynamics of the various plume components (ionic and nanoparticle) and basic properties of the ultrafast laser ablation process. While the ion temporal profile and ion angular distribution were analyzed by means of Langmuir ion probe technique, the angular distribution of the nanoparticulate component was characterized by measuring the thickness map of deposition on a transparent substrate. The amount of ablated material per pulse was found by applying scanning white light interferometry to craters produced on a stationary target. We have also compared the angular distribution of both the ionic and nanoparticle components with the Anisimov model. While the agreement for the ion angular distribution is very good at any laser fluence (from ablation threshold up to {approx_equal}1 J/cm{sup 2}), some discrepancies of nanoparticle plume angular distribution at fluencies above {approx_equal}0.4 J/cm{sup 2} are interpreted in terms of the influence of the pressure exerted by the nascent atomic plasma plume on the initial hydrodynamic evolution of the nanoparticle component. Finally, analyses of the fluence threshold and maximum ablation depth were also carried out, and compared to predictions of theoretical models. Our results indicate that the absorbed energy is spread over a length comparable with the electron diffusion depth L{sub c} ({approx_equal}30 nm) of Ni on the timescale of electron-phonon equilibration and that a logarithmic dependence is well-suited for the description of the variation in the ablation depth on laser fluence in the investigated range.

36 MATERIALS SCIENCE↗

High Current Cathodes Fabricated by KrF Laser Ablation

In this paper we review several high power laser ablation techniques that have been utilized to fabricate high current (1-80 kA) electron beam cathodes for accelerators and microwave sources: 1) Projection Ablation Lithography (PAL) cathodes, 2) Ablation Line Focus (ALF) cathodes, and 3) Metal-Oxide-Junction (MOJ) cathodes. Laser-ablative micromachining techniques (PAL and ALF) have been utilized to generate micron-scale features on metal substrates that provide electric field (beta) enhancement for Fowler-Nordheim emission and plasma cathodes. Since these laser-ablated patterns are directly, laser-written on the substrate metal they exhibit much higher thermal conductivity for higher current capability and increased damage thresholds. Metal-Oxide-Junction (MOJ) cathodes exploit the triple-point electron emission that occurs at the interface between metal, insulator and vacuum.The ablation laser is a KrF excimer laser with a pulse energy of 600 mJ and pulselength of 20 ns. Cathode experiments were performed on the MELBA-C accelerator: V = -300 kV, pulselength = 0.5 microsecond. Data will be presented for PAL, ALF and MOJ cathodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Update On CO{sub 2} Laser Ablation Of Polyoxymethylene At 101 kPa

Recent work has brought about a renewed interest in CO{sub 2} laser ablation studies of polyoxymethylene, due to its potential as a test target for enhancing modern understanding of the laser ablation process. In this paper, new results taken in air at atmosphere pressure are reported, including data measured at institutions in Germany and Japan, which increase the body of literature data on CO{sub 2} laser ablation of polyoxymethylene. The results are discussed in terms of aerospace parameters such as the momentum coupling coefficient and specific impulse, and are compared to a previous literature study. The threshold fluence is specified for ablation of polyoxymethylene by CO{sub 2} laser radiation. Fluences higher (and lower) than previously tested for CO{sub 2} laser ablation were studied herein, and record specific impulse values for CO{sub 2} laser ablation of flat polyoxymethylene are also reported here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling CO{sub 2} Laser Ablative Impulse with Polymers

Laser ablation vaporization models have usually ignored the spatial dependence of the laser beam. Here, we consider effects from modeling using a Gaussian beam for both photochemical and photothermal conditions. The modeling results are compared to experimental and literature data for CO{sub 2} laser ablation of the polymer polyoxymethylene under vacuum, and discussed in terms of the ablated mass areal density and momentum coupling coefficient. Extending the scope of discussion, laser ablative impulse generation research has lacked a cohesive strategy for linking the vaporization and plasma regimes. Existing models, mostly formulated for ultraviolet laser systems or metal targets, appear to be inappropriate or impractical for applications requiring CO{sub 2} laser ablation of polymers. A recently proposed method for linking the vaporization and plasma regimes for analytical modeling is addressed here along with the implications of its use. Key control parameters are considered, along with the major propulsion parameters needed for laser ablation propulsion modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser Ablation of Biological Tissue Using Pulsed CO{sub 2} Laser

Laser scalpels are currently used as a form of laser treatment. However, their ablation mechanism has not been clarified because laser excision of biological tissue occurs over a short time scale. Biological tissue ablation generates sound (laser-induced sound). This study seeks to clarify the ablation mechanism. The state of the gelatin ablation was determined using a high-speed video camera and the power reduction of a He-Ne laser beam. The aim of this study was to clarify the laser ablation mechanism by observing laser excision using the high-speed video camera and monitoring the power reduction of the He-Ne laser beam. We simulated laser excision of a biological tissue by irradiating gelatin (10 wt%) with radiation from a pulsed CO{sub 2} laser (wavelength: 10.6 {mu}m; pulse width: 80 ns). In addition, a microphone was used to measure the laser-induced sound. The first pulse caused ablation particles to be emitted in all directions; these particles were subsequently damped so that they formed a mushroom cloud. Furthermore, water was initially evaporated by laser irradiation and then tissue was ejected.

42 ENGINEERING↗

Preheating ablation effects on the Rayleigh-Taylor instability in the weakly nonlinear regime

The two-dimensional Rayleigh-Taylor instability (RTI) with and without thermal conduction is investigated by numerical simulation in the weakly nonlinear regime. A preheat model {kappa}(T)={kappa}{sub SH}[1+f(T)] is introduced for the thermal conduction [W. H. Ye, W. Y. Zhang, and X. T. He, Phys. Rev. E 65, 057401 (2002)], where {kappa}{sub SH} is the Spitzer-Haerm electron thermal conductivity coefficient and f(T) models the preheating tongue effect in the cold plasma ahead of the ablation front. The preheating ablation effects on the RTI are studied by comparing the RTI with and without thermal conduction with identical density profile relevant to inertial confinement fusion experiments. It is found that the ablation effects strongly influence the mode coupling process, especially with short perturbation wavelength. Overall, the ablation effects stabilize the RTI. First, the linear growth rate is reduced, especially for short perturbation wavelengths and a cutoff wavelength is observed in simulations. Second, the second harmonic generation is reduced for short perturbation wavelengths. Third, the third-order negative feedback to the fundamental mode is strengthened, which plays a stabilization role. Finally, on the contrary, the ablation effects increase the generation of the third harmonic when the perturbation wavelengths are long. Our simulation results indicate that, in the weakly nonlinear regime, the ablation effects are weakened as the perturbation wavelength is increased. Numerical results obtained are in general agreement with the recent weakly nonlinear theories as proposed in [J. Sanz, J. Ramirez, R. Ramis et al., Phys. Rev. Lett. 89, 195002 (2002); J. Garnier, P.-A. Raviart, C. Cherfils-Clerouin et al., Phys. Rev. Lett. 90, 185003 (2003)].

36 MATERIALS SCIENCE↗

Observations of multimode perturbation decay at non-accelerating, soft x-ray driven ablation fronts

Minimizing the growth of hydrodynamic instabilities is a fundamental design issue facing the achievement of thermonuclear ignition and burn with Inertial Confinement Fusion (ICF). The thin capsules and extreme accelerations found in ICF make it an inherently unstable system primarily to Rayleigh-Taylor (RT) occurring at the ablation front. A potential mechanism by which perturbations at the outer capsule surface can be reduced lies in the already present ablative Richtmyer-Meshkov (RM) effect, which operates during the first shock transit of the ablator. At present, the available Equation of State (EOS) models predict a wide range of behavior for the ablative RM oscillations of multimode isolated defects on plastic (CH) capsules. To resolve these differences, we conducted experiments at the OMEGA Laser Facility [T. R. Boehly et al., Optics Comm. 133 (1997)] that measured the evolution of gaussian-shaped bumps driven by soft x-ray ablation from a halfraum. Shock speeds in the CH target were measured to reach 15 {mu}m/ns for halfraum radiation temperatures of 70 eV lasting for up to 7 ns. The evolution of gaussian-shaped bumps of different widths and heights were measured using on-axis x-ray radiography at up to 37 Multiplication-Sign magnification. Bumps with initial widths of 34 and 44 {mu}m FWHM were found to grow by 3 Multiplication-Sign their initial areal density and then saturate out to 6 ns due to lateral compression of the bump characteristic of the formation of a rippled shock front propagating into the solid target. Narrower 17 {mu}m FWHM bumps, on the other hand, grew by roughly 2 Multiplication-Sign followed immediately by a decrease back to initial values of areal density out to 7 ns, which largely agrees with both LEOS 5310 and SESAME 7592 EOS predictions. The difference in observed behavior suggests that high spatial frequency modes found in narrower bumps are needed to significantly affect the ablation front profile on shorter time scales.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Doping He droplets by laser ablation with a pulsed supersonic jet source

Laser ablation offers the possibility to study a rich number of atoms, molecules, and clusters in the gas phase. By attaching laser ablated materials to helium nanodroplets, one can gain highly resolved spectra of isolated species in a cold, weakly perturbed system. Here, we present a new setup for doping pulsed helium nanodroplet beams by means of laser ablation. In comparison to more well-established techniques using a continuous nozzle, pulsed nozzles show significant differences in the doping efficiency depending on certain experimental parameters (e.g., position of the ablation plume with respect to the droplet formation, nozzle design, and expansion conditions). In particular, we demonstrate that when the ablation region overlaps with the droplet formation region, one also creates a supersonic beam of helium atoms seeded with the sample material. The processes are characterized using a surface ionization detector. The overall doping signal is compared to that of conventional oven cell doping showing very similar dependence on helium stagnation conditions, indicating a comparable doping process. Finally, the ablated material was spectroscopically studied via laser induced fluorescence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗