Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTERIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Absence of arterial baroreflex modulation of skin sympathetic activity and sweat rate during whole-body heating in humans

1. Prior findings suggest that baroreflexes are capable of modulating skin blood flow, but the effects of baroreceptor loading/unloading on sweating are less clear. Therefore, this project tested the hypothesis that pharmacologically induced alterations in arterial blood pressure in heated humans would lead to baroreflex-mediated changes in both skin sympathetic nerve activity (SSNA) and sweat rate. 2. In seven subjects mean arterial blood pressure was lowered (approximately 8 mmHg) and then raised (approximately 13 mmHg) by bolus injections of sodium nitroprusside and phenylephrine, respectively. Moreover, in a separate protocol, arterial blood pressure was reduced via steady-state administration of sodium nitroprusside. In both normothermia and heat-stress conditions the following responses were monitored: sublingual and mean skin temperatures, heart rate, beat-by-beat blood pressure, skin blood flow (laser-Doppler flowmetry), local sweat rate and SSNA (microneurography from peroneal nerve). 3. Whole-body heating increased skin and sublingual temperatures, heart rate, cutaneous blood flow, sweat rate and SSNA, but did not change arterial blood pressure. Heart rate was significantly elevated (from 74 +/- 3 to 92 +/- 4 beats x min(-1); P < 0.001) during bolus sodium nitroprusside-induced reductions in blood pressure, and significantly reduced (from 92 +/- 4 to 68 +/- 4 beats x min(-1); P < 0.001) during bolus phenylephrine-induced elevations in blood pressure, thereby demonstrating normal baroreflex function in these subjects. 4. Neither SSNA nor sweat rate was altered by rapid (bolus infusion) or sustained (steady-state infusion) changes in blood pressure regardless of the thermal condition. 5. These data suggest that SSNA and sweat rate are not modulated by arterial baroreflexes in normothermic or moderately heated individuals.

Clinical Trial↗

External artery heat pipe

An improved heat pipe with an external artery. The longitudinal slot in the heat pipe wall which interconnects the heat pipe vapor space with the external artery is completely filled with sintered wick material and the wall of the external artery is also covered with sintered wick material. This added wick structure assures that the external artery will continue to feed liquid to the heat pipe evaporator even if a vapor bubble forms within and would otherwise block the liquid transport function of the external artery.

Gernert, Nelson J.↗

Arterial Structure and Function in Women and Men Following Long Duration Bed Rest

Orthostatic intolerance is a well-recognized consequence of space flight and bed rest (BR), with a greater incidence reported in women. We hypothesized that leg, but not arm, arterial structure and function would be altered following prolonged BR, as a model of space flight, and that women would be more susceptible to BR-induced deconditioning than men. METHODS: Ten volunteers (5 males, 5 females) completed 90 d of 6 head-down BR. Subjects participated in tests of brachial (BA) and anterior tibial (AT) artery endothelium-dependent (flow mediated dilation [FMD] following 5-7 min of arterial occlusion) and endothelium-independent (0.4 mg sublingual nitroglycerin [SN]) vasodilation before BR (PRE) and on days 7 (BR7), 21 (BR21), and 90 (BR90) of BR. Vessel diameter and intimal medial thickness (IMT) were measured by ultrasound. IMT, baseline diameter, and percent change in diameter from baseline during FMD and SN tests were compared across BR and between genders using repeated measures two-way ANOVA with Bonferroni post-hoc tests in which PRE and women were control conditions. RESULTS: Baseline vessel diameter was lower in women than in men in both the BA (p=0.005) and AT (p=0.01) across all days. Baseline AT diameter decreased during BR (p=0.01) and tended to be more profound in women (interaction, p=0.06). AT diameter was reduced in women at BR21 and BR90 (p<0.01) but not in men. In contrast, there was no BR effect on baseline BA diameter. IMT also decreased in the AT (p<0.001) but not in the BA during BR; AT IMT was reduced by BR21 (p<0.05). As a group, there was no effect of BR on AT FMD, BA FMD, and AT SN-dilation, although BA SN-dilation was significantly reduced on BR21 (p=0.01). Across all BR days, women exhibited higher AT FMD (p=0.03), BA FMD (p=0.02), and BA SN-dilation (p=0.01) and tended to demonstrate greater AT SN-dilation (p=0.11). CONCLUSIONS: These preliminary results suggest that arterial remodeling occurs during BR in the leg (decreased diameter and IMT), but not in the arm, and that women appear to be more responsive to BR than men. These changes in the leg, coupled with larger responses to direct and indirect stimulation of the arterial smooth muscle, may be related to the greater incidence of orthostatic intolerance in women after BR and space flight.

Lee, Stuart M. C.↗

Analysis of Arterial Mechanics During Head-Down-Tilt Bed Rest

Carotid, brachial, and tibial arteries reacted differently to HDTBR. Previous studies have not analyzed the mechanical properties of the human brachial or anterior tibial arteries. After slight variations during bed-rest, arterial mechanical properties and IMT returned to pre-bed rest values, with the exception of tibial stiffness and PSE, which continued to be reduced post-bed rest while the DC remained elevated. The tibial artery remodeling was probably due to decreased pressure and volume. Resulting implications for longer duration spaceflight are unclear. Arterial health may be affected by microgravity, as shown by increased thoracic aorta stiffness in other ground based simulations (Aubert).

Elliott, Morgan B.↗

Offline Arterial Signal Timing Optimization based on Virtual Phase Link Model - A Real-world Case Study

Conventional signal timing for arterial usually takes bottom-up approaches. Engineers optimize each individual intersection first and then coordinate them by adjusting the offsets. This work is based on the Virtual Phase-Link (VPL) model, a street traffic model designed for online traffic model predictive control, to obtain a top-down offline arterial signal timing. We Studied the Shallowford Rd. in Chattanooga, TN and found that the inconsistency in intersection capacities along the arterial could lead to some intersections becoming bottlenecks. Signal timing is a significant factor that affect the intersection capacities. We realized that the VPL-based model can guarantee the consistency in intersections along an arterial. We therefore adopted the VPL-based model and developed an offline signal timing optimization approach. The proposed timing derived from the VPL-based offline signal timing optimization showed very good results in simulation. The Chattanooga Department of Transportation adopted the optimized timing obtained from the proposed approach and gave positive feedbacks to the research team. We also collected field experiment data, which demonstrated overall energy reductions and speed improvements on some sections of the Shallowford Rd. arterial. We will continue the experiment when the COVID-19 pandemic impact subsides to have a more robust quantitative evaluation.

Wang, Qichao↗

Continuous Intra-Arterial Nimodipine for the Treatment of Cerebral Vasospasm

Two patients with refractory symptomatic cerebral vasospasm after aneurysmal subarachnoid hemorrhage (SAH) were treated by continuous intra-arterial nimodipine infusion via a catheter placed in the internal carotid artery or vertebral artery for 3 and 12 days, respectively. Recovery of the neurological deficits, normalization of MR perfusion, a decrease in the elevated mean flow velocity measured by transcranial duplex sonography, and angiographic recanalization were observed. Continuous intra-arterial nimodipine might be a treatment option in severe refractory vasospasm following SAH.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carotid Artery Stenting Using a Novel Self-Expanding Braided Nickel-Titanium Stent: Feasibility and Safety Porcine Trial

We studied the deliverability and safety of a braided, self-expanding, closed-cell nickel-titanium (NiTi) stent (E-volution, Jotec GmbH, Hechingen, Germany) especially designed for the endovascular treatment of carotid artery bifurcation stenosis with special regard to in-stent stenosis and thrombosis compared with a laser-cut reference nitinol stent in a porcine model of percutaneous vascular interventions. We aimed to assess histopathologic response in minipig carotid and subclavian arteries. Eight minipigs received a total of 42 stents: 14 reference stents and 28 E-volution stents. Eleven of the E-volution stents were additionally coated with heparin. Control angiography was obtained immediately before and after vascular intervention as well as 4 weeks after the procedure. Primary endpoints were 28 days of angiographic analyses as well as histomorphometric analysis, including injury score, inflammation score, luminal diameter, vessel diameter, maximal neointimal thickness, and area of in-stent stenosis. Secondary end points were procedural success, 28-day mortality, and stent thrombosis. All stents could be delivered successfully without procedural complications, morbidity, or mortality during our observation time. As confirmed by histology, no in-stent thrombosis was observed. Compared with common carotid arteries, subclavian arteries are significantly more vulnerable to developing in-stent stenosis caused by neointima proliferation (p < 0.05). Compared with the use of 1 single stent/artery, serial application of two stents leads to a more excessive but not significantly different neointimal proliferation (p > 0.05). The E-volution stent, especially when heparin coated, is in line with the comparison to the laser-cut reference stent displaying similar results of angiographic, histologic, and histomorphometric analyses (p > 0.05). Compared with the reference laser-cut stent, the self-expanding nitinol stent (E-volution) with its advanced braiding technology is feasible and safe. In our opinion, the high radial resistive force and the advanced braided design with tight stent-strut interstices may be beneficial in terms of plaque stabilization. Further studies are necessary and warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carotid Artery Stenting: Single-Center Experience Over 11 Years

This article reports the results of carotid artery stenting during an 11-year period. Data from 168 carotid artery stenting procedures (symptomatic, n = 55; asymptomatic, n = 101; symptoms not accessible, n = 12) were retrospectively collected. Primary technical success rate, neurological events in-hospital, access-site complications, and contrast-induced nephropathy (n = 118) were evaluated. To evaluate the influence of experience in carotid artery stenting on intraprocedural neurologic complications, patients were divided into two groups. Group 1 included the first 80 treated patients, and group 2 the remainder of the patients (n = 88). In-stent restenoses at last-follow-up examinations (n = 89) were assessed. The overall primary technical success rate was 95.8%. The in-hospital stroke-death rate was 3.0% (n = 5; symptomatic, 5.4%; asymptomatic, 2.0%; p = 0.346). Neurologic complications were markedly higher in group 1 (4.2%; three major strokes; symptomatic, 2.8%, asymptomatic, 1.4%) compared to group 2 (2.4%; one major and one minor stroke-symptomatic, 1.2%, asymptomatic 1.2%), but this was not statistically significant. Further complications were access-site complications in 12 (7.1%), with surgical revision required in 1 (0.6%) and mild contrast-induced nephropathy in 1 (0.85%). Twenty-one (23.6%) patients had >50% in-stent restenosis during a mean follow-up of 28.2 months. In conclusion, advanced experience in carotid artery stenting leads to an acceptable periprocedural stroke-death rate. In-stent restenosis could be a critical factor during the follow-up course.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Stroke and Obstruction of the Extracranial Carotid Artery Combined with Intracranial Tandem Occlusion: Results of Interventional Revascularization

PurposeDue to high thrombus load, acute stroke patients with tandem obstructions of the extra- and intracranial carotid arteries or the middle cerebral artery show a very limited response to systemic thrombolysis. Interventional treatment with mechanical thrombectomy—often in combination with acute stenting of underlying atherosclerotic stenosis or dissection—is increasingly used. It has been shown that such complex interventions are technically feasible. The lack of optimal management strategies and clinical data encouraged us to review our acute stroke interventions in patient with anterior circulation tandem lesions to determine lesion patterns, interventional approaches, and angiographic or clinical outcomes.Patients and MethodsWe retrospectively analyzed a series of 39 consecutive patients with intracranial vessel occlusion of the anterior circulation simultaneously presenting with high-grade cervical internal carotid artery (ICA) stenosis or occlusion.ResultsEmergency ICA stent implantation was technically feasible in all patients, and intracranial recanalization with TICI ≥ 2b was reached in a large number of patients (64 %). Good clinical outcomes (mRS ≤ 2 at 3 months) were achieved in one third of the patients (36 %). Symptomatic hemorrhages occurred in four patients (10 %). Mortality was 10 %.ConclusionEndovascular recanalization of acute cervical carotid artery occlusion was technically feasible in all patients, and resulted in high extra- and intracranial revascularization rates. A trend for favorable clinical outcome was seen in a higher TICI score, younger age, good collateral status, and combined IV rTPA and endovascular therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Upregulation of contractile endothelin type B receptors by lipid-soluble cigarette smoking particles in rat cerebral arteries via activation of MAPK

Cigarette smoke exposure increases the risk of stroke. However, the underlying molecular mechanisms are poorly understood. Endothelin system plays key roles in the pathogenesis of stroke. The present study was designed to examine if lipid-soluble (dimethyl sulfoxide-soluble) cigarette smoke particles (DSP) induces upregulation of contractile endothelin type B (ET{sub B}) receptors in rat cerebral arteries and if activation of mitogen activated protein kinase (MAPK) and nuclear factor-kappaB (NF-{kappa}B) mediate the upregulation of contractile endothelin receptors in the cerebral arteries. Rat middle cerebral arteries were isolated and organ cultured in serum free medium for 24 h in the presence of DSP with or without specific inhibitors: MEK specific (U0126), p38 specific (SB202190), JNK specific (SP600125), NF-{kappa}B specific (BMS-345541) or (IMD-0354), transcription inhibitor (actinomycin D), or translation blocker (cycloheximide). Contractile responses to the ET{sub B} receptor agonist sarafotoxin 6c were investigated by a sensitive myograph. The expression of the ET{sub B} receptors were studied at mRNA and protein levels using quantitative real time PCR and immunohistochemistry, respectively. Results show that organ culture per se induced transcriptional upregulation of contractile ET{sub B} receptors in the cerebral vascular smooth muscle cells. This upregulation was further increased at the translational level by addition of DSP to the organ culture, but this increase was not seen by addition of nicotine or water-soluble cigarette smoke particles to the organ culture. The increased upregulation of contractile ET{sub B} receptors by DSP was abrogated by U0126, SP600125, actinomycin D, and cycloheximide, suggesting that the underlying molecular mechanisms involved in this process include activation of MEK and JNK MAPK-mediated transcription and translation of new contractile ET{sub B} receptors. Thus, the MAPK-mediated upregulation of contractile ET{sub B} receptors in cerebral arteries might be a pharmacological target for the treatment of smoke-associated cerebral vascular disease like stroke.

60 APPLIED LIFE SCIENCES↗

Patient Presentation and Management of Labial Ulceration Following Uterine Artery Embolization

Uterine artery embolization is a safe and effective procedure for the treatment of symptomatic uterine fibroids. Nontarget embolization of adjacent internal iliac artery branches is a reported complication of uterine artery embolization. The following report describes the presentation and management of ulcerations of the labium minora due to nontarget embolization of the internal pudendal artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gadolinium-Enhanced Angiography for Diagnosis and Interventional Treatment of Subclavian Artery Stenosis Prior to Fistula Creation

We report the use of gadolinium-based contrast agent for both diagnostic and interventional subclavian angiography in two azotemic patients, presenting with an asymptomatic, high-grade stenosis of the left subclavian artery, ipsilateral to the site of choice for native fistula creation. Angiographic imaging performed with diluted gadolinium-based contrast material was clear enough to perform successful subclavian artery stenting, resulting in normalization of the arterial blood pressure in the afferent artery of the dialysis fistula. Clinically, no decrease in residual renal function and no other complication were noted immediately or a longer period after the interventional treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Common Iliac Occlusion in the Presence of Persistent Sciatic Artery

Persistent sciatic artery is a rare congenital anomaly. It is associated with increased incidence of aneurysmal dilatation, thrombosis, distal embolization, and atherosclerotic change. We describe the case of a patient with persistent sciatic artery who presented with a critically ischemic left leg as a result of an occluded left common iliac artery, which was treated by angioplasty and stenting, and discuss the endovascular iliac recanalization in the presence of a persistent sciatic artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photodynamic Therapy of the Canine Prostate: Intra-arterial Drug Delivery

Purpose. Interstitial photodynamic therapy (PDT) selectively destroys tissue targeted with a photosensitizer and then exposed to light of a specific wavelength. We report a novel delivery method-intra-arterial drug delivery for PDT of the prostate-in a canine model.Methods. To evaluate drug distribution, the prostatovesical artery was selectively cannulated and photosensitizers alone or in conjunction with 99m-technetium-labeled macro-aggregated albumin ({sup 99m}Tc-MAA) were injected via a 3 Fr microcatheter in 8 animals. One dog was followed for 3 months to determine tolerance and toxicity. The remaining animals were euthanized and imaged with whole-body single photon emission CT and gamma counting for radioactivity distribution. Photosensitizer distribution was further analyzed by fluorescence confocal microscopy and tissue chemical extraction. To evaluate PDT, the photosensitizer QLT0074 was infused in 3 animals followed by interstitial illumination with 690 nm laser light. Results. Intra-arterial infusion selectively delivered drugs to the prostate, with both radioactivity and photosensitizer levels significantly higher (up to 18 times) than in the surrounding organs (i.e., rectum). With unilateral injection of {sup 99m}Tc-MAA, only the injected half of the prostate showed activity whereas bilateral administration resulted in drug delivery to the entire prostate. PDT resulted in comprehensive damage to the prostate without severe complications or systemic toxicity. Conclusion. Injection of radiolabeled MAA into the prostatovesical artery results in distribution within the prostate with negligible amounts reaching the adjacent organs. PDT also demonstrates selective damage to the prostate, which warrants clinical application in targeted prostate therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Coil Embolization of Splenic Artery Aneurysm

The purpose of this study was to evaluate clinical results and technical problems of transcatheter coil embolization for splenic artery aneurysm. Subjects were 16 patients (8 men, 8 women; age range, 40-80 years) who underwent transcatheter embolization for splenic artery aneurysm (14 true aneurysms, 2 false aneurysms) at one of our hospitals during the period January 1997 through July 2005. Two aneurysms (12.5%) were diagnosed at the time of rupture. Multiple splenic aneurysms were found in seven patients. Aneurysms were classified by site as proximal (or strictly ostial) (n = 3), middle (n = 3), or hilar (n = 10). The indication for transcatheter arterial embolization was a false or true aneurysm 20 mm in diameter. Embolic materials were fibered coils and interlocking detachable coils. Embolization was performed by the isolation technique, the packing technique, or both. Technically, all aneurysms were devascularized without severe complications. Embolized aneurysms were 6-40 mm in diameter (mean, 25 mm). Overall, the primary technical success rate was 88% (14 of 16 patients). In the remaining 2 patients (12.5%), partial recanalization occurred, and re-embolization was performed. The secondary technical success rate was 100%. Seven (44%) of the 16 study patients suffered partial splenic infarction. Intrasplenic branching originating from the aneurysm was observed in five patients. We conclude that transcatheter coil embolization should be the initial treatment of choice for splenic artery aneurysm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microballoon Occlusion Test to Predict Colonic Ischemia After Transcatheter Embolization of a Ruptured Aneurysm of the Middle Colic Artery

A 76-year-old woman presented with sudden massive melena, and superior mesenteric arteriography showed an aneurysm in the middle colic artery (MCA). Because she had a history of right hemicolectomy and ligation of the inferior mesenteric artery (IMA) during open abdominal aortic aneurysm repair, embolization of the MCA aneurysm was considered to pose a risk comparable to that of colonic ischemia. A microballoon occlusion test during occlusion of the MCA confirmed retrograde visualization of the IMA branches through the collateral arteries by way of the left internal iliac artery, and embolization was successfully performed using microcoils. No colonic ischemia or aneurysm rupture occurred after embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Central Retinal and Posterior Ciliary Artery Occlusion After Intralesional Injection of Sclerosant to Glabellar Subcutaneous Hemangioma

The aim of this study is to describe vision loss caused by central retinal artery and posterior ciliary artery occlusion as a consequence of sclerotherapy with a polidocanol injection to a glabellar hemangioma. An 18-year-old man underwent direct injection with a 23-gauge needle of 1 mL of a polidocanol-carbon dioxide emulsion into the glabellar subcutaneous hemangioma under ultrasound visualization of the needle tip by radiologists. He developed lid swelling the next day, and 3 days later at referral, the visual acuity in the left eye was no light perception. Funduscopy revealed central retinal artery occlusion and fluorescein angiography disclosed no perfusion at all in the left fundus, indicating concurrent posterior ciliary artery occlusion. The patient also showed mydriasis, blepharoptosis, and total external ophthalmoplegia on the left side. Magnetic resonance imaging demonstrated the swollen medial rectus muscle. In a month, blepharoptosis and ophthalmoplegia resolved but the visual acuity remained no light perception. Sclerosing therapy for facial hemangioma may develop a severe complication such as permanent visual loss.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a New Balloon Catheter for Difficult Calcified Lesions in Infrainguinal Arterial Disease: Outcome of a Multicenter Registry

The purpose of this study was to assess the technical performance and immediate procedure outcome of a new balloon catheter in the treatment of calcified lesions in infrainguinal arterial disease. Seventy-five patients with infrainguinal arterial disease were prospectively entered into the registry. The catheter (ReeKross Clearstream, Ireland) is a 5- to 6-Fr balloon catheter with a rigid shaft intended for enhanced pushability. Only technical procedural outcome was recorded. Treated calcified lesions (range: 5-30 cm), assessed angiographically, were located in the superficial femoral, popliteal, and crural arteries. In 67 patients the lesion was an occlusion. Guidewire passage occurred subintimally in 68 patients. In 24 patients a standard balloon catheter was chosen as first treatment catheter: 5 failed to cross the lesion, 8 balloons ruptured, and in 11 patients there was an inadequate dilatation result. In only one of the five patients did subsequent use of the ReeKross catheter also fail in lesion crossing. The ReeKross was successful as secondary catheter in the other 23 cases. In 50 patients the ReeKross was used as primary catheter. In total the ReeKross crossed the lesions in 74 patients. After passage and dilatation with this catheter in 73 patients (1 failed true-lumen reentry), 19 had >30% residual lesions, of which 11 were not treated and 8 were successfully stented. No ReeKross balloons ruptured. We conclude that in the treatment of difficult calcified lesions in arterial stenotic or occlusive disease, the choice of a high-pushability angioplasty catheter, with more calcification-resistant balloon characteristics, like the ReeKross, warrants consideration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗