Computational Fluid Dynamics Simulations to Assess Spatial Variability and Optimal Ventilation Scenarios for Biological Laboratory Exposures

A significant amount of uncertainty exists regarding potential human exposure to laboratory biomaterials and organisms in Biosafety Level 2 (BSL-2) research laboratories. Computational fluid dynamics (CFD) modeling is proposed as a way to better understand potential impacts of different combinations of biomaterials, laboratory manipulations, and exposure routes on risks to laboratory workers. Here, in this study, we use CFD models to simulate airborne concentrations of contaminants in an actual BSL-2 laboratory under different configurations. Results show that ventilation configuration, sampling location, and contaminant source location can significantly impact airborne concentrations and exposures. Depending on the source location and airflow patterns, the transient and time-integrated concentrations varied by several orders of magnitude. Contaminant plumes from sources located near a return vent (or exhaust like a fume hood or ventilated biosafety cabinet) are likely to be more contained than sources that are further from the exhaust. Having a direct flow between the source and the exhaust (through-flow condition) may reduce potential exposures to individuals outside the air flow path. Designing a BSL-2 room with ventilation and airflow patterns that maximize through-flow conditions to the return/exhaust vents and minimize dispersion and mixing throughout the room is, therefore, recommended. CFD simulations can also be used to assist in characterizing the impacts of supply and return vent locations, room layout, and source locations on spatial and temporal contaminant concentrations. In addition, proper placement of particle sensors can also be informed by CFD simulations to provide additional characterization and monitoring of potential exposures in BSL-2 facilities.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Indoor air quality in California homes with code-required mechanical ventilation

Data were collected in 70 detached houses built in 2011-2017 in compliance with the mechanical ventilation requirements of California's building energy efficiency standards. Each home was monitored for a 1-week period with windows closed and the central mechanical ventilation system operating. Pollutant measurements included time-resolved fine particulate matter (PM 2.5 ) indoors and outdoors and formaldehyde and carbon dioxide (CO 2 ) indoors. Time-integrated measurements were made for formaldehyde, NO 2 , and nitrogen oxides (NO X ) indoors and outdoors. Operation of the cooktop, range hood, and other exhaust fans was continuously recorded during the monitoring period. Onetime diagnostic measurements included mechanical airflows and envelope and duct system air leakage. All homes met or were very close to meeting the ventilation requirements. On average, the dwelling unit ventilation fan moved 50% more airflow than the minimum requirement. Pollutant concentrations were similar to or lower than those reported in a 2006-2007 study of California new homes built in 2002-2005. Mean and median indoor concentrations were lower by 44% and 38% for formaldehyde and 44% and 54% for PM 2.5 . Ventilation fans were operating in only 26% of homes when first visited, and the control switches in many homes did not have informative labels as required by building standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Power Reclamation of Micro Hydro Turbines in WWTPs Aeration Basins

Abstract This study investigates the optimum operating conditions and design configurations that can optimize the power reclaimed by small hydro turbines derived by the rising water-bubble current. The rising current is generated by the compressed air introduced by the diffusers at the bottom of aeration basins of Wastewater Treatment Plants (WWTPs). While optimizing the power production, the standard oxygen transfer efficiency (SOTE) is monitored since it is a significant parameter that cannot be sacrificed in the operation of WWTPs. Using one set of turbine blades, it was found out that the highest velocity is obtained in the upper half of the water column (70% - 80%). In contrast, the lowest velocities were obtained just above the air diffuser and at the water surface. Testing started with using a single turbine (ST) to determine the location of the optimum power reclaimed at each tested airflow (1.18, 1.42, 1.65, and 1.89 L/s). Then using double turbine (DT) and triple turbine (TT) to compare their performance to the ST’s maximum power increased power reclamation. The maximum percentage of increase in power reclamation for DT is 19.59%, while it is 20.24% in the case of TT. At a commonly used airflow in WWTPs (1.42 L/s), the optimum configurations of DTs and TTs were selected to investigate the effect of having the proposed setup on the SOTE. For membrane diffusers, DTs and TTs limited the dispersion of the air bubbles in the tank, therefore, reducing the SOTE (8.3% for DT and 3.7% for the TT). The ceramic and sharp-nub diffusers were also tested versus rubber membrane ones to determine the effect of using the ceramic and sharp-nub diffusers on the power reclamation and SOTE. Ceramic diffusers neither achieve higher power reclamation than the membrane nor increases the SOTE. In contrast, sharp-nub diffusers increase the SOTE for all configurations compared to membranes, but this came into account of power reclamation, where sharp-nub diffusers cause a DT and a TT to produce less power than ST does.

Energy & Fuels↗

Numerical Modeling of Atmospheric Rime Ice Accretion on an Airfoil Using an Eulerian Approach

This paper presents an approach to numerically simulate the inherently unsteady rime ice accretion problem on a two-dimensional airfoil and elucidate the associated variations under different icing conditions. The airflow field and the water impingement on the airfoil are obtained based on an Eulerian two-phase model. A dynamic mesh strategy is employed to unsteadily account for the changes in the ice profile and its impact on the air and droplet flow by continuously reconstructing the computational grid at each time-step through smoothing and layering mechanisms. All main icing modules including the airflow field, droplet trajectory, icing thickness profile, and mesh management are fully coupled within the same computational framework without resorting to any external tools. Classical icing theory is employed to model the rime ice roughness, and it is assumed that the ice accretes in a direction normal to the airfoil surface. The governing Reynolds-averaged Navier–Stokes (RANS) conservation equations along with the energy and continuity equations are solved to produce the velocity and temperature fields. A convective film heat transfer coefficient is computed based on the surface heat flux and a recovery temperature which takes into account the dissipative heat release in the boundary layer in the vicinity of the airfoil surface. With the implemented strategy and calculating the convective heat transfer coefficient, the water film thickness is also calculated along with the ice shape. Furthermore, the model is validated by comparing the local collection efficiency distribution and ice shape with experimental data, and the results show that the implemented approach provides acceptable predictions of ice accretion profiles and rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deeplynx Dag Repository

The DeepLynx DAG repository will contain several Airflow DAGs (Directed Acyclic Graphs) which will be used in the context of DeepLynx's deployed Apache Airflow instance. These DAGs will be used for multiple data management tasks for DeepLynx data, including but not limited to: - bringing data from various sources and tools into DeepLynx - managing sequential data workflows, such as running Python scripts on data to perform analysis and returning the results to DeepLynx - performing any necessary transformation or pre-processing on data coming into DeepLynx from external sources or out of DeepLynx to go to external applications

Brownlee, JarenM.↗

Enhancing Short-Range Weather Forecasts through Temporal Variation Encoding: A Multiperiod Embedding Approach

Machine learning (ML) techniques have emerged as promising approaches to improve regional weather forecast accuracy and reliability through data-driven methods. We propose a novel ML-based weather forecasting model, the Multiperiod Embed Net (MPENet). A key distinguishing feature of MPENet is its explicit utilization of the inherent cyclic nature in weather dynamics, unlike the autoregressive strategies commonly used in other ML weather forecasting approaches. Critical cyclic structures are identified via Fourier analyses of dynamic time series. Cyclicity in the convolutional representation is achieved by transforming one-dimensional time series of meteorological variables into two-dimensional tensors based on identified periods. This approach enables the model to leverage intrinsic weather patterns, enhancing regional forecast performance. To demonstrate the effectiveness of MPENet, we conduct a comparative analysis with Nvidia’s FourCastNet. Both models are trained on High-Resolution Rapid Refresh (HRRR) data from 2015 to 2022, over a 192 km × 192 km region in Tennessee. The comparisons are performed locally at two specific locations known to have different weather dynamics due to orographic effects: Crossville, on the relatively flat Cumberland Plateau with fewer topographic airflow disruptions, and Oak Ridge, in the ridge-and-valley region, where airflow is heavily influenced by surrounding valleys and mountains. Our results indicate that FourCastNet achieves strong accuracy at very short lead times, while MPENet maintains competitive skill and shows advantages in capturing temporal evolution over longer periods. Cross-correlation analyses of MPENet and FourCastNet predictions with the HRRR data suggest that encoding critical cyclicity into the network architecture leads to improvements in the forecasting skill.

Artificial intelligence↗

Dual-Fuel Ammonia Equivalence Ratio Sweep Data

Ammonia (NH3) has garnered significant interest as an alternative fuel for meeting international emissions reduction mandates in sectors with high weight and distance requirements, such as shipping. Technical barriers and unanswered questions remain on the combustion strategies that can maximize ammonia utilization and minimize emissions. Prior research studies at the US Department of Energy’s Oak Ridge National Laboratory have shown strong performance with NH3 under dual-fuel mode using conventional diesel combustion (CDC) manifold air pressure settings. Diesel airflow was initially used to simplify retrofitting (no turbocharger modification), which resulted in air-fuel equivalence ratios (λ) greater than 1.5. To characterize potential improvements in dual-fuel NH3 combustion performance at richer in-cylinder conditions, a global λ sweep compared the use of early (E-pilot) and late (L-pilot) single diesel injections. The experiments were conducted at 1200 RPM and 12.8 ± 0.2 bar (75 % load), and λ was varied by decreasing the commanded air flow to the engine at greater than 90 % ammonia energy substitution level. A diesel injection timing sweep was conducted for both the injection strategies at fixed λ, and the timing with the lowest engine-out N2O emissions was identified. The results indicated an optimal balance between CO2,eq and thermal efficiency benefits both E-pilot and L-pilot injection strategy cases compared with CDC at a λ of 1.4. The indicated nitrogen-based emissions exhibited a strong correlation to the ratio of CA5–50 and ignition delay for L-pilot, but no apparent trend emerged for the E-pilot injection strategy at the tested boundary conditions. This dataset includes the raw experimental data and documentation of the experiment conditions and methods.

30 DIRECT ENERGY CONVERSION↗

NUMERICAL INVESTIGATION OF AIR DEHUMIDIFICATION THROUGH WATER DROPLETS DIELECTROPHORESIS

This paper numerically investigated the dehumidification of moist airflow in a converging rectangular duct with electrically enhanced condensation. The aim was to develop a condensation model that predicted water vapor condensation by employing the dielectrophoresis principle. The charged droplets were injected into the computational domain to produce a gradient electric field. The dielectrophoretic interaction between the droplets and vapor molecules of the humid air resulted in local water vapor condensation at the vapor and liquid droplet interface. This phenomenon is described in detail in this paper. A hybrid Eulerian-Lagrangian solver SprayFoam was developed based on OpenFOAM® to simulate condensation in two-phase gas-liquid mixtures. The following developments were made based on the standard compressible multiphase flow solver SprayFoam in OpenFOAM®: (1) Eulerian solver for gas phase (2) multi-component species transport, and (3) Lagrangian solver for gas-droplet two-phase flows and sub-models for liquid droplets. The newly developed numerical model was experimentally validated with data from a series of tests conducted in the authors' laboratory. The results showed that the simulations followed the same trends as the data, and the model predicted the condensation due to the electro-spray injection process in the air stream. The injected water droplets, which are electrically charged to their Rayleigh limits, increased in size while wiping out the humidity from the air. The simulations indicated that the dehumidification was about 1% for 0.5 cubic feet per minute airflow rate. Scaling up to larger flows is a future follow-up work.

Yel Mahi, *Maliha↗

Ventilation in Residential Care Environments

The purpose of this study was to evaluate the effect of ventilation rate, directional airflow (e.g. pressure relationships) and airflow barriers on bioaerosol concentration and movement within assisted-living and residential care environments. Included within this report is a comprehensive literature review, field data collection test plan and, an evaluation of commercially available mitigation technologies related to the transmission of COVID-19 in LTC environments. Additionally, this report includes aerosol testing in an actual LTC facility using the test plan developed herein. Nearly 1.5 million people live in 16,000 nursing homes in the U.S. As of December 20, 2020 the Centers for Medicare and Medicaid Services (CMS) identified a total of 662,549 confirmed and suspected COVID-19 cases in these and other long-term care (LTC) facilities resulting in 92,373 deaths. At this time, COVID-19 cases in LTC facilities accounted for only 3% of the U.S. total of 21M confirmed cases yet nearly a third of the 350,000 total U.S. deaths. Preliminary studies have found little correlation between the quality of care and transmission of COVID-19 in these facilities, suggesting that even the best infection control practices may not be effective in containing the spread of this potentially airborne disease. As a result, many LTC facilities have implemented quarantine procedures and other measures to isolate infectious residents from the general population. Unfortunately, most LTC facilities were not designed for airborne infection control and guidance for retrofitting existing LTC spaces for airborne isolation is limited.

42 ENGINEERING↗

Technical analysis of filter testing at the U.S. Department of Energy Filter Test Facility

The U.S. Department of Energy (DOE) technical standard DOE-STD-3020-2015 requires verification testing at the Filter Test Facility (FTF) of high-efficiency particulate air (HEPA) filters to be installed in nuclear facility (Hazard Category 1, 2, 3, and radiological facilities) confinement ventilation systems, or to be installed in habitability systems (e.g., filters for protection of workers required to act for the control and mitigation of emergency situations). Filters in these applications perform a safety function in accident situations, are designated as important to safety, or are necessary for habitability systems. Different FTFs have operated for decades, and results of tests are available to examine the need for and benefits of continued execution of 100 percent QA verification testing. The objective of this study and resulting report was to assess the need for 100 percent QA testing at the current FTF in Maryland, based on an examination of a database of test results from 2013 to August 2020. Filters that require independent testing per DOE-STD-3020-2015 to be installed in nuclear facilities are sent to the FTF before being shipped to the facilities. The FTF examines the documentation (e.g., certificates of compliance, results of particle penetration and airflow resistance testing by the manufacturers, labels affixed to filters and packages, and other requirements specified in purchase orders by the nuclear facility operators), implements visual inspections of the physical state of the filters, and checks the dimensions of frames. Filters that meet the documentation and visual inspection requirements are subjected to particle penetration and airflow resistance testing. In case of rejections, the filters are shipped back to the manufacturers, at the cost of the manufacturers, for replacement. Filters that pass all tests are shipped to the nuclear facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Statistical Analysis of Imaging Laser Scan Data of an Exhaust Tunnel at the SRS

• The SRS H-Canyon Building is a critical facility under the responsibility of DOE-EM. • It includes an Air Exhaust Tunnel (HCAEX) that allows for ventilation of the process airflow. • Inspections are performed remotely because of hazards, e.g. radioactivity, debris, high airflow, and nitric acid vapors.

Wells, William Willie [Savannah River National Lab↗

New Thermochemical Salt Hydrate System for Energy Storage in Buildings

This paper introduces an innovative design for an “inorganic salt-expanded graphite” composite thermochemical system. The storage unit is made of a perforated, compressed, expanded graphite block impregnated with molten CaCl 2 ∙6H 2 O; the humid air passes through the holes that allow the moisture to diffuse and react with the salt. The prepared block underwent 90 hydration-dehydration cycles. Although most of the performed cycles were carried out with salt overhydration and deliquescence, the treated samples have remained mechanically and thermally stable with no drop in energy density. The volumetric energy density of the composite ranged from 135.5 to 277.6 kWh/m 3 , depending on airflow rate and absolute humidity. To ensure composite material cycling stability, the energy density of the block was measured during hydration at similar conditions of absolute humidity, inlet temperature, and airflow rate (0.01 kg water /kg air , 20 °C, 400 l/min). The average energy density at these conditions was sustained at 219 kWh/m 3 . The block integrity was monitored by visual inspection after removing it from the reactor chamber every few cycles. Both the composite material and its manufacturing process are simple and easy to scale up for future commercialization.

25 ENERGY STORAGE↗

The mechanisms and seasonal differences of the impact of aerosols on daytime surface urban heat island effect

The urban heat island intensity (UHII) is the temperature difference between urban areas and their rural surroundings. It is commonly attributed to changes in the underlying surface structure caused by urbanization. Air pollution caused by aerosol particles can affect the UHII through changing (1) the surface energy balance by the aerosol radiative effect (ARE) and (2) planetary-boundary-layer (PBL) stability and airflow intensity by modifying thermodynamic structure, which is referred to as the aerosol dynamic effect (ADE). By analyzing satellite data and ground-based observations collected from 2001 to 2010 at 35 cities in China and using the WRF-Chem model, we find that the impact of aerosols on UHII differs considerably: reducing the UHII in summer but increasing the UHII in winter. This seasonal contrast is proposed to be caused by the different strengths of the ARE and ADE between summer and winter. In summer, the ARE on UHII is dominant over the ADE, cooling down surface temperature more strongly in urban areas than in rural areas because of much higher aerosol loading, and offsets the urban heating, therefore weakening UHII. In winter, however, the ADE is more dominant, because aerosols stabilize the PBL more in the polluted condition, weakening the near-surface heat transport over urban areas in both vertical and horizontal directions. This means that the heat accumulated in urban areas is dispersed less effectively, and thus the UHII is enhanced. These findings shed new light on the impact of the interaction between urbanization-induced surface changes and air pollution on urban climate.urban areas and their rural surroundings. It is commonly attributed to changes in the underlying surface structure caused by urbanization. Air pollution caused by aerosol particles can affect the UHII through changing (1) the surface energy balance by the aerosol radiative effect (ARE) and (2) planetary-boundary-layer (PBL) stability and airflow intensity by modifying thermodynamic structure, which is referred to as the aerosol dynamic effect (ADE). By analyzing satellite data and ground-based observations collected from 2001 to 2010 at 35 cities in China and using the WRF-Chem model, we find that the impact of aerosols on UHII differs considerably: reducing the UHII in summer but increasing the UHII in winter. This seasonal contrast is proposed to be caused by the different strengths of the ARE and ADE between summer and winter. In summer, the ARE on UHII is dominant over the ADE, cooling down surface temperature more strongly in urban areas than in rural areas because of much higher aerosol loading, and offsets the urban heating, therefore weakening UHII. In winter, however, the ADE is more dominant, because aerosols stabilize the PBL more in the polluted condition, weakening the near-surface heat transport over urban areas in both vertical and horizontal directions. This means that the heat accumulated in urban areas is dispersed less effectively, and thus the UHII is enhanced. These findings shed new light on the impact of the interaction between urbanization-induced surface changes and air pollution on urban climate.

54 ENVIRONMENTAL SCIENCES↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electron beam seals outer surfaces of porous bodies

Porous tungsten plugs provide even airflow for frictionless bearings used in air bearing supported gyros. The plugs have their outer cylindrical surface sealed by an electron beam process to ensure unidirectional airflow through their exit ends.

Herz, W. H.↗

Experimental techniques for evaluating steady-state jet engine performance in an altitude facility

Jet engine calibration tests were conducted in an altitude facility using a contoured bellmouth inlet duct, four fixed-area water-cooled exhaust nozzles, and an accurately calibrated thrust measuring system. Accurate determination of the airflow measuring station flow coefficient, the flow and thrust coefficients of the exhaust nozzles, and the experimental and theoretical terms in the nozzle gross thrust equation were some of the objectives of the tests. A primary objective was to develop a technique to determine gross thrust for the turbojet engine used in this test that could also be used for future engine and nozzle evaluation tests. The probable error in airflow measurement was found to be approximately 0.6 percent at the bellmouth throat design Mach number of 0.6. The probable error in nozzle gross thrust measurement was approximated 0.6 percent at the load cell full-scale reading.

Smith, J. M.↗