Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACUTE EXPOSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Below-Background Ionizing Radiation as an Environmental Cue for Bacteria

All organisms on earth grow under the influence of a natural and relatively constant dose of ionizing radiation referred to as background radiation, and so cells have different mechanisms to prevent the accumulation of damage caused by its different components. However, current knowledge of the deleterious effects of radiation on cells is based on the exposure to acute and high or to chronic, above background doses of radiation and therefore is not appropriate to explain the cellular and biochemical mechanisms that cells employ to sense and respond to chronic below-background levels. Studies at below-background radiation doses can provide insight into the biological role of radiation, as suggested by several examples of what appears to be a stress response in cells grown at doses that range from 10 to 79 times lower than background. Here, we discuss some of the technical constraints to shield cells from radiation to below-background levels, as well as different approaches used to detect and measure responses to such unusual environmental conditions. Then, we present data from Shewanella oneidensis and Deinococcus radiodurans experiments that show how two taxonomically distant bacterial species sense and respond to unnaturally low levels of radiation. Finally, in brief, we grew S. oneidensis and D. radiodurans in liquid culture at dose rates of 72.05 (control) and 0.91 (treatment) nGy hr -1 (including radon) for up to 72 h and measured cell density and the expression of stress-related genes. Our results suggest that a stress response is triggered in the absence of normal levels of radiation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Applying Deep Learning for Wildfire Identification: Economical and Accessible Solutions Leveraging Small Datasets

Wildfires significantly impact human health, air quality, visibility, weather, and climate change and cause substantial economic losses. While state and county-operated air quality monitors provide critical insights during wildfires, they are not available in all regions. This highlights the need for affordable, accessible tools that allow the general public to assess air quality impacts. In this study, we apply machine learning with deep neural networks to diagnose air quality rapidly from sky images taken at the Pacific Northwest National Laboratory in Richland, WA, USA. Using a convolutional neural network (CNN) framework, we trained a deep learning model to classify air quality indices based on sky images. By leveraging transfer learning, our approach fine-tunes a pre-trained model on a small dataset of sky images, significantly reducing training time while maintaining high accuracy. Our results demonstrate the potential of deep learning to provide rapid air quality diagnostics during wildfire episodes, offering early warnings to the public and enabling timely mitigation strategies, particularly for vulnerable populations. Additionally, we show that lower respiratory infections pose the highest health risk during acute smoke exposures. Reactive oxygen species (ROS) from wildfire particles further exacerbate health risks by triggering inflammation and other adverse effects.

54 ENVIRONMENTAL SCIENCES↗

Hypergravity induced prolactin surge in female rats

Acute initial exposure to hypergravity (HG) was previously found to induce prolonged diestrous in rats, which was followed by return to normal estrous cycling upon more prolonged exposure to continuous HG. Bromergocryptine was found to prevent this prolonged diestrous. In this study it is found that in female rats 20 h of 3.14 G exposure (D-1 1200 h until D-2 0800 h) can induce prolactin surge at D-2 1600 h. Shorter exposure time (8 h), or exposure during a different part of the estrous cycle (19 h: from D-1 0700 h until D-2 0200 h) could not elicit this prolactin surge. Similar exposure of male rats of HG did not alter significantly their prolactin levels. It is possible that the hypothalamus of male and female rats responds differently to stimulation by HG.

Megory, E.↗

Hypovolemia During Early Exposure to 2,800 m Altitude: Effect of Rehydration

The mechanism for reduction of total body water and plasma volume (PV) during initial exposure to acute attitude (ALT) is not clear. Ten man (25+/-SD 3yr. 1.99+/-0.l9sq m) were confined (sitting) for 12 hr in a chamber a 2800m ALT or at 305m(ground). They ate a controlled breakfast (450 kcal + 3ml/kg H2O) on the ground, and lunch and dinner at ALT for a total daily intake of 2,850 kcal (14%PRO, 67%CHO, 16%FAT, 26gNaCl). At hr 10 they consumed fluid-electrolyte drinks or water (12ml/kg, 948ml/day) with sessions at weekly intervals: (a) 185mEq/L Na, 283mOsm/kg; (b) 21.6Na, 365mOsm: and (c) water at ALT: and (d) water on the ground. After 10 hr at ALT%(Delta)PV(Hb-Hct) decreased (P<0.05) by (a) 9.0+/-SE1.5%, (b) 6.2+/-1.7%, (c) 7.4+/-2.2%. and (d) 9.0+/-2.4%. respectively. After drinking at 1200 hr PV increased by (a) 8.3% (P<0.05), (b) 2.8% (NS), (c) -0.9% (NS). and (d) by 0.8% (NS). respectively. The ground-induced hypovolemia suggests a confinement rather than an ALT effect. The increase in PV after the NaCl-NaCitrate drink (a) indicates that drink composition is mom important than as Osm for restoring PV in these Conditions.

Greenleaf, J. E.↗

CO2 Washout Testing of the REI and EM-ACES Space Suits

Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. The objective of this test was to characterize inspired oronasal ppCO2 in the Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES) across a range of workloads and flow rates for which ground testing is nominally performed. Three subjects were tested in each suit. In all but one case, each subject performed the test twice to allow for comparison between tests. Suit pressure was maintained at 4.3 psid. Subjects wore the suit while resting, performing arm ergometry, and walking on a treadmill to generate metabolic workloads of approximately 500 to 3000 BTU/hr. Supply airflow was varied at 6, 5 and 4 actual cubic feet per minute (ACFM) at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the total CO2 production measured by an additional gas analyzer at the air outlet from the suit. Real-time metabolic rate was used to adjust the arm ergometer or treadmill workload to meet target metabolic rates. In both suits, inspired CO2 was primarily affected by the metabolic rate of the subject, with increased metabolic rate resulting in increased inspired ppCO2. Suit flow rate also affected inspired ppCO2, with decreased flow causing small increases in inspired ppCO2. The effect of flow was more evident at metabolic rates greater than or equal to 2000 BTU/hr. Results were consistent between suits, with the EM-ACES demonstrating slightly better CO2 washout than the REI suit, but not statistically significant. Regression equations were developed for each suit to predict the mean inspired ppCO2 as a function of metabolic rate and suit flow rate. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future ground testing in the REI and EM-ACES.

Mitchell, Kate↗

CO2 Washout Testing of the REI and EM-ACES Space Suits

When a space suit is used during ground testing, adequate carbon dioxide (CO2) washout must be provided for the suited subject. Symptoms of acute CO2 exposure depend on partial pressure of CO2 (ppCO2), metabolic rate of the subject, and other factors. This test was done to characterize inspired oronasal ppCO2 in the Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES) for a range of workloads and flow rates for which ground testing is nominally performed. Three subjects were tested in each suit. In all but one case, each subject performed the test twice. Suit pressure was maintained at 4.3 psid. Subjects wore the suit while resting, performing arm ergometry, and walking on a treadmill to generate metabolic workloads of about 500 to 3000 BTU/hr. Supply airflow was varied between 6, 5, and 4 actual cubic feet per minute (ACFM) at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored in real time by gas analyzers with sampling tubes connected to the mask. Metabolic rate was calculated from the total CO2 production measured by an additional gas analyzer at the suit air outlet. Real-time metabolic rate was used to adjust the arm ergometer or treadmill workload to meet target metabolic rates. In both suits, inspired CO2 was affected mainly by the metabolic rate of the subject: increased metabolic rate significantly (P < 0.05) increased inspired ppCO2. Decreased air flow caused small increases in inspired ppCO2. The effect of flow was more evident at metabolic rates . 2000 BTU/hr. CO2 washout values of the EM-ACES were slightly but not significantly better than those of the REI suit. Regression equations were developed for each suit to predict the mean inspired ppCO2 as a function of metabolic rate and suit flow rate. This paper provides detailed descriptions of the test hardware, methodology, and results as well as implications for future ground testing in the REI-suit and EM-ACES.

Mitchell, Kathryn C.↗

CO2 Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. Computational Fluid Dynamic (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test is to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III space suit across a range of workload and flow rates. As a secondary objective, results will be compared to the predicted CO2 concentrations and used to refine existing CFD models. These CFD models will then be used to help design an inlet vent configuration for the Z-2 space suit, which maximizes oronasal CO2 washout. This test has not been completed, but is planned for January 2014. The results of this test will be incorporated into this paper. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES). Three subjects will be tested in the Mark-III space suit with each subject performing two test sessions to allow for comparison between tests. Six different helmet inlet vent configurations will be evaluated during each test session. Suit pressure will be maintained at 4.3 psid. Subjects will wear the suit while walking on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute (ACFM) will be tested at each workload. Subjects will wear an oronasal mask with an open port in front of the mouth and will be allowed to breathe freely. Oronasal ppCO2 will be monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate will be calculated from the total oxygen consumption and CO2 production measured by additional gas analyzers at the air outlet from the suit. Real-time metabolic rate measurements will be used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent design and ground testing in the Mark-III.

Korona, F. Adam↗

CO2 Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. Computational Fluid Dynamic (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test was to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III suit across a range of workload and flow rates. Data and trends observed during testing along with refined CFD models will be used to help design an inlet vent configuration for the Z-2 space suit. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES). Three subjects performed two test sessions each in the Mark-III suit to allow for comparison between tests. Six different helmet inlet vent configurations were evaluated during each test session. Suit pressure was maintained at 4.3 psid. Suited test subjects walked on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute (ACFM) were tested at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the total oxygen consumption and CO2 production measured by additional gas analyzers at the air outlet from the suit. Realtime metabolic rate measurements were used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent designs and ground testing.

Korona, F. Adam↗

CO2 Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. Computational Fluid Dynamic (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test was to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III suit across a range of workload and flow rates. Data and trends observed during testing along with refined CFD models will be used to help design an inlet vent configuration for the Z-2 space suit. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES). Three subjects performed two test sessions each in the Mark-III suit to allow for comparison between tests. Six different helmet inlet vent configurations were evaluated during each test session. Suit pressure was maintained at 4.3 psid. Suited test subjects walked on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute (ACFM) were tested at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the total oxygen consumption and CO2 production measured by additional gas analyzers at the air outlet from the suit. Real-time metabolic rate measurements were used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent designs and ground testing.

Korona, F. Adam↗

Carbon Dioxide Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy, and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject, and physiological differences between subjects. Computational Fluid Dynamics (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test was to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III suit across a range of workload and flow rates. Data and trends observed during testing along with refined CFD models will be used to help design an inlet vent configuration for the Z-2 space suit. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit, and the Enhanced Mobility Advanced Crew Escape Suit. Three subjects performed two test sessions each in the Mark-III suit to allow for comparison between tests. Six different helmet inlet vent configurations were evaluated during each test session. Suit pressure was maintained at 4.3 psid. Suited test subjects walked on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute were tested at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the CO2 production measured by an additional gas analyzer at the air outlet from the suit. Real-time metabolic rate measurements were used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent designs and ground testing.

Korona, F. Adam↗

CO2 Washout Testing of NASA Space Suits

During the presentation "CO2 Washout Testing of NASA Spacesuits," Jason Norcross discussed the results of recent carbon dioxide CO2 washout testing of NASA spacesuits including the Rear Entry I-suit (REI), Enhanced Mobility Advanced Crew Escape Suit (EM-ACES), and possibly the ACES and Z-1 EVA prototype. When a spacesuit is used during ground testing, adequate CO2 washout must be provided for the suited subject. Symptoms of acute CO2 exposure depend on the partial pressure of CO2 (ppCO2) available to enter the lungs during respiration. The primary factors during ground-based testing that influence the ppCO2 level in the oronasal area include the metabolic rate of the subject and air flow through the suit. These tests were done to characterize inspired oronasal ppCO2 for a range of workloads and flow rates for which ground testing is nominally performed. During this presentation, Norcross provided descriptions of the spacesuits, test hardware, methodology, and results, as well as implications for future ground testing and verification of flight requirements.

Norcross, Jason↗

Challenges in Clinical Management of Radiation-Induced Illnesses in Exploration Spaceflight

Historical solar particle events (SPEs) provide context for some understanding of acute radiation exposure risk to astronauts traveling outside of low Earth orbit. Modeling of potential doses delivered to exploration crewmembers anticipates limited radiation-induced health impacts, including prodromal symptoms of nausea, emesis, and fatigue, but suggests that more severe clinical manifestations are unlikely. Recent large animal-model research in space-analogs closely mimicking SPEs has identified coagulopathic events independent of the hematopoietic sequelae of higher radiation doses, similar in manifestation to disseminated intravascular coagulation (DIC). We explored the challenges of clinical management of radiation-related clinical manifestations, using currently accepted modeling techniques and anticipated physiological sequelae, to identify medical capabilities needed to successfully manage SPE-induced radiation illnesses during exploration spaceflight.

Blue, Rebecca↗

Effect of Carbon Dioxide Exposure on Physical and Cognitive Performance in a Simulated Spaceflight Contingency Scenario

Introduction: Carbon dioxide (CO2) produced by astronauts inside space suits can accumulate to levels that affect health and performance. The human health and performance risks associated with different levels of CO2 exposure in the flight environment remain an area of debate. The purpose of this study is to characterize the limit of acceptable performance (cognitive and physical) decrements and symptom severity for mission operations when subjected to elevated inspired CO2 levels in the spacesuit during contingency EVA scenarios. Methods: This study will create a simulation of a 1-hour contingency EVA walk back to the habitat, incorporating a passive treadmill and a fully immersive virtual reality (VR) simulation of a lunar EVA. Subjects will be asked to walk on a treadmill while breathing partial pressures of CO2 of 0, 5, 10, 15, 20, 25, 30mmHg for 1 hour at a time. Cognitive performance will be quantified using validated cognitive tests and measures of functional task performance embedded within the VR environment. Test subject symptoms and self-assessment of performance will be evaluated via survey. Results: This study currently has approval from NASA’s Institutional Review Board and has completed the Test Readiness Review process. Next steps for this research study include test subject recruitment, data collection, and analysis. Data collection is planned for calendar year 2022 and 2023. Discussion: This study will provide valuable information regarding how various partial pressures of CO2 exposure impact acute health, as well as cognitive and physical performance during simulated lunar EVA. This information will be vital in the assessment of overall risk associated with current hardware (vehicle and suit) design for upcoming exploration missions. It will also be invaluable for informing future standards and requirements.

carbon dioxide↗

Effect of Carbon Dioxide Exposure on Physical and Cognitive Performance in A Simulated Spaceflight Contingency Scenario

INTRODUCTION: Carbon dioxide (CO2) produced by astronauts inside space suits can accumulate to levels that may affect health and performance. The human health and performance risks associated with different levels of CO2 exposure in the flight environment remain an area of debate. The purpose of this study is to characterize the limit of acceptable performance (cognitive and physical) decrements and symptom severity for mission operations when subjected to elevated inspired CO2 levels in simulated contingency lunar extravehicular activity (EVA) scenarios. METHODS: This study will create a simulation of a 1-hour, ~2km contingency EVA walk back to a habitat, incorporating a passive treadmill and a fully immersive virtual reality (VR) simulation of a lunar EVA environment. Subjects will be asked to walk on a treadmill while breathing partial pressures of CO2 of 0, 5, 10, 15, 20, 25, 30mmHg for 1 hour at a time. Cognitive performance will be quantified using validated cognitive tests and measures of functional task performance embedded within the VR environment. Test subject symptoms and self-assessment of performance will be evaluated via survey. RESULTS: This study currently has approval from NASA’s Institutional Review Board and has completed the Test Readiness Review process. Next steps for this research study include test subject recruitment, data collection, and analysis. Data collection is planned for calendar year 2023 and 2024. DISCUSSION: This study will provide valuable information regarding how various partial pressures of CO2 exposure impact acute health, as well as cognitive and physical performance during simulated contingency lunar EVA. This information will enable assessment of health and performance risk associated with spacesuit systems and operations concepts for future exploration missions as well as informing definition of future standards and requirements.

D. M. Nusbaum↗

Neurobiological Outcomes of Mice Exposed to Combined Spaceflight Stressors

As NASA plans for exploration beyond Low-Earth Orbit, it is imperative to understand how deep spaceflight stressors impact human physiology. Deep space exposes crew members to multiple NASA-defined risks, including altered gravity, ionizing radiation, and social isolation. While the effects of individual stressors have been studied, there are still gaps in our understanding of their combined effects. In this study, we utilized the simulated five-ion galactic cosmic radiation (GCR) and isolation to assess the combinatorial effects of space stressors on the central nervous system (CNS) in mice. Our study captures sexually dimorphic responses by quantifying CNS outcomes in crewage-matched male and female mice. We assessed CNS responses in mice exposed to four days of isolation, followed by three different dosage of acute radiation exposure (5 cGy, 15 cGy, and 50 cGy 5-ion GCRsim). Comprehensive hippocampal cytokine biomarker analyses were conducted in both males and females at two weeks post-irradiation (intermediate cohort) and 124 days post-irradiation (delayed cohort). Proteomics on hippocampal lysates were conducted in the delayed cohort. Our results provide evidence for sex-specific differentially regulated hippocampal cytokines and proteomic profiles. Immunohistochemical analysis of the mice brain from intermediate and delayed cohorts is currently underway for multiple protein markers, including microglial activation, astrocytes, and dopaminergic neuronal population, among others. This project closely aligns with NASA’s efforts to characterize sex-specific risks associated with deep space exploration. We anticipate the results from this project will aid in our understanding of spaceflight stressors to ensure crew health and performance.

spaceflight↗