Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACOUSTIC MEASUREMENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Towards direct realisation of the SI unit of sound pressure in the audible hearing range based on optical free-field acoustic particle measurements

Since the introduction of the International System of Units (the SI system) in 1960, weights, measures, standardised approaches, procedures, and protocols have been introduced, adapted, and extensively used. A major international effort and activity concentrate on the definition and traceability of the seven base SI units in terms of fundamental constants, and consequently those units that are derived from the base units. In airborne acoustical metrology and for the audible range of frequencies up to 20 kHz, the SI unit of sound pressure, the pascal, is realised indirectly and without any knowledge or measurement of the sound field. Though the principle of reciprocity was originally formulated by Lord Rayleigh nearly two centuries ago, it was devised in the 1940s and eventually became a calibration standard in the 1960s; however, it can only accommodate a limited number of acoustic sensors of specific types and dimensions. International standards determine the device sensitivity either through coupler or through free-field reciprocity but rely on the continuous availability of specific acoustical artefacts. Here, we show an optical method based on gated photon correlation spectroscopy that can measure sound pressures directly and absolutely in fully anechoic conditions, remotely, and without disturbing the propagating sound field. It neither relies on the availability or performance of any measurement artefact nor makes any assumptions of the device geometry and sound field characteristics. Most importantly, the required units of sound pressure and microphone sensitivity may now be experimentally realised, thus providing direct traceability to SI base units.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of acoustic properties of microalgae and implications for the performance of ultrasonic harvesting systems

Microalgae are a promising feedstock for biofuel production, but difficulties associated with harvesting suspended cultures contribute to the high costs of algal feedstock production. Ultrasonic harvesting has been identified as a potential low-cost technique, but limited data are available on the response of microalgae cells in the presence of an acoustic field. The acoustic radiation force acting on a cell depends upon cell size and the acoustic contrast factor (ACF) of the cell in the media. The ACF depends upon the density and compressibility of the cell and the media. Cell size and ACF were measured for Microchloropsis gaditana, Nannochloropsis oculata, Phaeodactylum tricornutum, and Chlamydomonas reinhardtii. The average ACFs, which were determined by measuring the densities and sound velocities of suspensions containing varying concentrations of cells in growth media, were 0.04 (range = 0.03–0.05) for M. gaditana, 0.02 (range = 0.01–0.04) for N. oculata, 0.05 (range = 0.04–0.07) for P. tricornutum, and 0.05 (range = 0.049–0.053) for C. reinhardtii. The ratio of the acoustic radiation force to the drag force would be highest for C. reinhardtii cells due to their larger effective radius (5.6 μm compared to 1.9–2.7 μm for the other species). The effective ACF of C. reinhardtii was also evaluated by recording the motion of cells in the presence of an acoustic field, using particle tracking velocimetry, and then modeling the recorded motion using COMSOL Multiphysics software. The result (ACF = 0.04) demonstrated agreement with the density/sound velocity meter method. Experiments with starch null sta6 mutant C. reinhardtii cells demonstrated that the effective ACF can transition from positive to zero and eventually become negative as microalgae cells accumulate lipids. Furthermore, the dynamic nature of the ACF represents an opportunity and a challenge for acoustic harvesting of algal cells.

09 BIOMASS FUELS↗

Measurements of Acoustic Properties of Porous and Granular Materials and Application to Vibration Control

For application of porous and granular materials to vibro-acoustic controls, a finite dynamic strength of the solid component (frame) is an important design factor. The primary goal of this study was to investigate structural vibration damping through this frame wave propagation for various poroelastic materials. A measurement method to investigate the vibration characteristics of the frame was proposed. The measured properties were found to follow closely the characteristics of the viscoelastic materials - the dynamic modulus increased with frequency and the degree of the frequency dependence was determined by its loss factor. The dynamic stiffness of hollow cylindrical beams containing porous and granular materials as damping treatment was measured also. The data were used to extract the damping materials characteristics using the Rayleigh-Ritz method. The results suggested that the acoustic structure interaction between the frame and the structure enhances the dissipation of the vibration energy significantly.

Park, Junhong↗

GE MOD-1 noise study

Noise studies of the MOD-1 Wind Turbine Generator are summarized, and a simple mathematical noise is presented which is adequate to correlate the sound levels found near the machine. A simple acoustic measure is suggested for use in evaluating far field sound levels. Use of this measure as input to a currently available sound complaint prediction program is discussed. Results of a recent statistical survey relative to the far field variation of this acoustic measure because of atmospheric effects are described.

Wells, R. J.↗

On the possibility of baryon acoustic oscillation measurements at redshift z > 7.6 with the Roman space telescope

ABSTRACT The Nancy Grace Roman Space Telescope (RST), with its field of view and high sensitivity will make surveys of cosmological large-scale structure possible at high redshifts. We investigate the possibility of detecting baryon acoustic oscillations (BAO) at redshifts z > 7.6 for use as a standard ruler. We use data from the hydrodynamic simulation bluetides in conjunction with the gigaparsec-scale Outer Rim simulation and a model for patchy reionization to create mock RST High Latitude Survey grism data for Lyman α emission line selected galaxies at redshifts z = 7.4 to z = 10, covering 2280 deg2. We measure the monopoles of galaxies in the mock catalogues and fit the BAO features. We find that for a line flux of $L = 7\times 10^{-17} \ {\rm erg\, s^{-1}\, cm}^{-2}$, the 5σ detection limit for the current design, the BAO feature is partially detectable (measured in three out of four survey quadrants analysed independently). The resulting root mean square error on the angular diameter distance to z = 7.7 is 7.9 ${{\ \rm per\ cent}}$. If we improve the detection sensitivity by a factor of two (i.e. $L = 3.5\times 10^{-17} \ {\rm erg\, s^{-1}\, cm}^{-2}$), the distance error reduces to $1.4{{\ \rm per\ cent}}$. We caution that many more factors are yet to be modelled, including dust obscuration, the damping wing due to the intergalactic medium, and low redshift interlopers. If these issues do not strongly affect the results, or different observational techniques (such as use of multiple lines) can mitigate them, RST, or similar instruments may be able to constrain the angular diameter distance to the high redshift universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Traversing Microphone Track Installed in NASA Lewis' Aero-Acoustic Propulsion Laboratory Dome

The Aero-Acoustic Propulsion Laboratory is an acoustically treated, 65-ft-tall dome located at the NASA Lewis Research Center. Inside this laboratory is the Nozzle Acoustic Test Rig (NATR), which is used in support of Advanced Subsonics Technology (AST) and High Speed Research (HSR) to test engine exhaust nozzles for thrust and acoustic performance under simulated takeoff conditions. Acoustic measurements had been gathered by a far-field array of microphones located along the dome wall and 10-ft above the floor. Recently, it became desirable to collect acoustic data for engine certifications (as specified by the Federal Aviation Administration (FAA)) that would simulate the noise of an aircraft taking off as heard from an offset ground location. Since nozzles for the High-Speed Civil Transport have straight sides that cause their noise signature to vary radially, an additional plane of acoustic measurement was required. Desired was an arched array of 24 microphones, equally spaced from the nozzle and each other, in a 25 off-vertical plane. The various research requirements made this a challenging task. The microphones needed to be aimed at the nozzle accurately and held firmly in place during testing, but it was also essential that they be easily and routinely lowered to the floor for calibration and servicing. Once serviced, the microphones would have to be returned to their previous location near the ceiling. In addition, there could be no structure could between the microphones and the nozzle, and any structure near the microphones would have to be designed to minimize noise reflections. After many concepts were considered, a single arched truss structure was selected that would be permanently affixed to the dome ceiling and to one end of the dome floor.

Bauman, Steven W.↗

In-flight near- and far-field acoustic data measured on the Propfan Test Assessment (PTA) testbed and with an adjacent aircraft

Flight tests to define the far-field tone source at cruise conditions were completed on the full-scale SR-7L advanced turboprop that was installed on the left wing of a Gulfstream 2 aircraft. This program, designated Propfan Test Assessment (PTA), involved aeroacoustic testing of the propeller over a range of test conditions. These measurements defined source levels for input into long-distance propagation models to predict en route noise. In-flight data were taken for seven test cases. Near-field acoustic data were taken on the Gulfstream fuselage and on a microphone boom that was mounted on the Gulfstream wing outboard of the propeller. Far-field acoustic data were taken by an acoustically instrumented Learjet that flew in formation with the Gulfstream. These flight tests were flown from El Paso, Texas, and from the NASA Lewis Research Center. A comprehensive listing of the aeroacoustic results from these flight tests which may be used for future analysis are presented.

Woodward, Richard P.↗

A Study of Acoustic Reflections in Full-Scale Rotor Low Frequency Noise Measurements Acquired in Wind Tunnels

Difficulties in obtaining full-scale rotor low frequency noise measurements in wind tunnels are addressed via residual sound reflections due to non-ideal anechoic wall treatments. Examples illustrated with the Boeing-SMART rotor test in the National Full-Scale Aerodynamics Complex (NFAC) 40- by 80-Foot Wind Tunnel facility demonstrated that these reflections introduced distortions in the measured acoustic time histories that are not representative of free-field rotor noise radiation. A simplified reflection analysis, based on the method of images, is used to examine the sound measurement quality in such "less-than-anechoic" environment. Predictions of reflection-adjusted acoustic time histories are qualitatively shown to account for some of the spurious fluctuations observed in wind tunnel noise measurements

Barbely, Natasha L.↗

Issues on Reproducibility/Reliability of Magnetic NDE Methods

One of the critical elements related to the practicality of any NDE technique is its reproducibility under nominally the same inspection conditions. The results of certain test methodologies, however, are not always repeatable and understanding the origin of the irreproducibility is often as critical as obtaining reproducible results. One example is the characterization of residual stress in structural ferromagnets using the magnetoacoustic (MAC) method. Although it has not been widely publicized, the test results of this method are known to be time-dependent. Two distinct types of time dependencies have been observed during testing. The first type has a clearly definable relaxation time, while no such trend has been observed for the second. The purpose of the present study is to systematically investigate the time dependence of the second type, to find out the range and, if possible, the origin of the variation in the test results. For this, MAC curves were obtained under various stress levels and the tests were repeated over time. Particular attention was given to whether noise in the measuring device or a change in the laboratory environment could have been a contributing factor. The steel samples used for the study were cut from C- and U-class railroad wheels. The MAC behavior of these samples was reported previously. Each steel sample was first machined to be a cylindrical rod of 3.175 cm (1.25 in) in diameter and 26.67 cm (10.5 in) in length. The center portion of the samples were further machined to form a pair of flat and parallel surfaces for the launch and reflection of the ultrasonic pulses. Data acquisition involved two major elements; magnetic and acoustic measurements. Throughout the experiment the net magnetic induction, B, was measured by integrating the induction pickup coil output using an integrating fluxmeter. The acoustic measurements employed the phase-locked technique which will be described in the following.

Namkung, M.↗

ATK Launch Vehicle (ALV-X1) Liftoff Acoustic Environments: Prediction vs. Measurement

The ATK Launch Vehicle (ALV-X1) provided an opportunity to measure liftoff acoustic noise data. NASA Marshall Space Flight Center (MSFC) engineers were interested in the ALV-X1 launch because the First Stage motor and launch pad conditions, including a relativity short deflector ducting, provide a potential analogue to future Ares I launches. This paper presents the measured liftoff acoustics on the vehicle and tower. Those measured results are compared to predictions based upon the method described in NASA SP-8072 "Acoustic Loads Generated by the Propulsion System" and the Vehicle Acoustic Environment Prediction Program (VAEPP) which was developed by MSFC acoustics engineers. One-third octave band sound pressure levels will be presented. This data is useful for the ALV-X1 in validating the pre-launch environments and loads predictions. Additionally, the ALV-X1 liftoff data can be scaled to define liftoff environments for the NASA Constellation program Ares vehicles. Vehicle liftoff noise is caused by the supersonic jet flow interaction with surrounding atmosphere or more simply, jet noise. As the vehicle's First Stage motor is ignited, an acoustic noise field is generated by the exhaust. This noise field persists due to the supersonic jet noise and reflections from the launch pad and tower, then changes as the vehicle begins to liftoff from the launch pad. Depending on launch pad and adjacent tower configurations, the liftoff noise is generally very high near the nozzle exit and decreases rapidly away from the nozzle. The liftoff acoustic time range of interest is typically 0 to 20 seconds after ignition. The exhaust plume thermo-fluid mechanics generates sound at approx.10 Hz to 20 kHz. Liftoff acoustic noise is usually the most severe dynamic environment for a launch vehicle or payload in the mid to high frequency range (approx.50 to 2000 Hz). This noise environment can induce high-level vibrations along the external surfaces of the vehicle and surrounding launch facility structures. The acoustic pressure fluctuations will induce severe vibrations in relatively large lightweight structures. Consequently, there is the potential for failure of the structure or attached electrical components. Due to these potential failures, the liftoff acoustic noise is one of the noise source inputs used to determine the vibro-acoustic qualification environment for a launch vehicle and its components.

Houston, Janice↗

Slow-Wave Acoustic Isolation For Measurement Of Flow

Propagation of interfering signals delayed. Experiments demonstrated utility of slow-wave isolation between transmitting and receiving transducers in acoustic measurements of sound speed and/or flow velocity in ducts. Specifically, finding pertains to acoustic measurements of speeds of flow of low-molecular-weight gases at pressures low enough to be contained in thin-walled metal conduits.

Lynnworth, Lawrence C.↗

Acoustic building infiltration measurement system

Systems and methods of detecting and identifying a leak from a container or building. Acoustic pressure and velocity are measured. Acoustic properties are acquired from the measured values. The acoustic properties are converted to infiltration/leakage information. Nearfield Acoustic Holography (NAH) may be one method to detect the leakages from a container by locating the noise sources.

47 OTHER INSTRUMENTATION↗

Acoustic Emission Measurement with Fiber Bragg Gratings for Structure Health Monitoring

Structural Health monitoring (SHM) is a way of detecting and assessing damage to large scale structures. Sensors used in SHM for aerospace structures provide real time data on new and propagating damage. One type of sensor that is typically used is an acoustic emission (AE) sensor that detects the acoustic emissions given off from a material cracking or breaking. The use of fiber Bragg grating (FBG) sensors to provide acoustic emission data for damage detection is studied. In this research, FBG sensors are used to detect acoustic emissions of a material during a tensile test. FBG sensors were placed as a strain sensor (oriented parallel to applied force) and as an AE sensor (oriented perpendicular to applied force). A traditional AE transducer was used to collect AE data to compare with the FBG data. Preliminary results show that AE with FBGs can be a viable alternative to traditional AE sensors.

Banks, Curtis E.↗

Acoustic Emission Measurement with Fiber Bragg Gratings for Structure Health Monitoring

Structural Health monitoring (SHM) is a way of detecting and assessing damage to large scale structures. Sensors used in SHM for aerospace structures provide real time data on new and propagating damage. One type of sensor that is typically used is an acoustic emission (AE) sensor that detects the acoustic emissions given off from a material cracking or breaking. The use of fiber Bragg grating (FBG) sensors to provide acoustic emission data for damage detection is studied. In this research, FBG sensors are used to detect acoustic emissions of a material during a tensile test. FBG sensors were placed as a strain sensor (oriented parallel to applied force) and as an AE sensor (oriented perpendicular to applied force). A traditional AE transducer was used to collect AE data to compare with the FBG data. Preliminary results show that AE with FBGs can be a viable alternative to traditional AE sensors.

Banks, Curtis E.↗

Measurements of acoustic responses of gaseous propellant injectors

Results are presented for an investigation intended to provide experimental data that can quantitatively describe the way in which various coaxial injector designs affect the stability of gaseous propellant rocket motors. The response factors of configurations that simulate the flow conditions in a gaseous-fuel injector element and a gaseous-oxidizer injector element are measured by using a modified impedance-tube technique and under cold-flow conditions simulating those observed in rocket motors with axial instability. The measured injector response factor data are presented and discussed. It is shown that there is reasonable agreement between the measured injector response factors and those predicted by the Feiler and Heidmann model (1967), and that the orifice length can be varied to shift the resonant frequency of the injector without any change in the magnitude of the response factor at resonance. A change in the injector open-area ratio is found to have a significant effect on the characteristics of the injector response factor.

Janardan, B. A.↗

Anechoic chamber in industrial plants

A light anechoic chamber for routine acoustical measurements in the machine building industry is reported. The outer housing of the chamber consists of modules cast in glass fiber reinforced polyester resin; the inner housing consists of pyramidal modules cut out of sound absorbing slates. The parameters of this anechoic chamber facilitate acoustical measurements according to ISO and CAEM recommendations.

Halpert, E.↗

Comparison of Two Acoustic Waveguide Methods for Determining Liner Impedance

Acoustic measurements taken in a flow impedance tube are used to assess the relative accuracy of two waveguide methods for impedance eduction in the presence of grazing flow. The aeroacoustic environment is assumed to contain forward and backward-traveling acoustic waves, consisting of multiple modes, and uniform mean flow. Both methods require a measurement of the complex acoustic pressure profile over the length of the test liner. The Single Mode Method assumes that the sound pressure level and phase decay-rates of a single progressive mode can be extracted from this measured complex acoustic pressure profile. No a priori assumptions are made in the Finite Element. Method regarding the modal or reflection content in the measured acoustic pressure profile. The integrity of each method is initially demonstrated by how well their no-flow impedances match those acquired in a normal incidence impedance tube. These tests were conducted using ceramic tubular and conventional perforate liners. Ceramic tubular liners were included because of their impedance insensitivity to mean flow effects. Conversely, the conventional perforate liner was included because its impedance is known to be sensitive to mean flow velocity effects. Excellent comparisons between impedance values educed with the two waveguide methods in the absence of mean flow and the corresponding values educed with the normal incident impedance tube were observed. The two methods are then compared for mean flow Mach numbers up to 0.5, and are shown to give consistent results for both types of test liners. The quality of the results indicates that the Single Mode Method should be used when the measured acoustic pressure profile is clearly dominated by a single progressive mode, and the Finite Element Method should be used for all other cases.

Jones, Michael G.↗