At least 235 records · Page 13

Percutaneous Laser Ablation of Liver Metastases from Neuroendocrine Neoplasm. A Retrospective Study for Safety and Effectiveness

Purpose: To retrospectively assess safety and efficacy of laser ablation (LA) of multiple liver metastases (LM) from neuroendocrine neoplasms (NEN). Methods: Twenty-one patients with NEN and at least 3 LM ≤ 4 cm in diameter underwent ultrasonography-guided LA. Up to seven LM were ablated in a single session; if the number of LM exceeded seven, the remaining LM were ablated in further LA sessions with a time interval of 3–4 weeks. LA was performed according to the multifiber technique. The patients underwent contrast-enhanced CT 1 month after LA, and were subsequently monitored every 3 months for the first 2 years and then every 6 months. Results: In total, 189 LM were treated in 21 patients (mean 9 ± 8.2, median 6) in 41 LA sessions (range 1–5). The diameter of LM ranged from 5 to 35 mm (median 19 mm, mean 17.9 ± 6.4 mm). One grade 4 complication occurred (0.53%): a bowel perforation managed by surgery. Technical efficacy was 100%, primary efficacy rate 94.7%, and secondary efficacy rate 100%. Complete relief of hormone-related symptoms was obtained in all the 13 symptomatic patients. Median follow-up was 39 months (range 12–99). 1-, 2-, 3-, and 5-year survival rates were 95%, 86%, 66%, and 40%, respectively. Overall survival resulted higher for patients with Ki-67 expression ≤ 7% than for those with Ki-67 > 7% (p = 0.0347). Conclusions: LA is a promising and safe technique to treat LM from NEN. A longer follow-up should provide definitive information on the long-term efficacy of this liver-directed therapy. Level of Evidence: Retrospective study, local non-random sample, level 3.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonintrusive manufactured solutions for ablation

The study of heat transfer and ablation plays an important role in many problems of scientific and engineering interest. As with the computational simulation of any physical phenomenon, the first step toward establishing credibility in ablation simulations involves code verification. Code verification is typically performed using exact and manufactured solutions. However, manufactured solutions generally require the invasive introduction of an artificial forcing term within the source code such that the code solves a modified problem for which the solution is known. In this paper, we present a nonintrusive method for manufacturing solutions for a non-decomposing ablation code, which does not require the addition of a source term.

42 ENGINEERING↗

Spatio-temporal ablation dynamics and plasma chemistry of aluminum induced by temporally modulated ytterbium fiber laser

Here, in this work, we studied single-pulse ablation dynamics of a temporally modulated continuous wave laser-material interaction with Al using in situ multimodal time-resolved diagnostics that describe in detail the associated physical and chemical processes. Time-resolved scattering, emission imaging, and optical emission spectroscopy unveiled a sequence of events spread out across three distinct phases: (i) early phase ablation process, associated with particle generation and liquid Al column formation (<20 μs), (ii) secondary detonation when sufficient ejected material is accumulated over the surface (20-50 μs), and (iii) molten liquid Al pool oscillation on the surface, followed by large droplet ejection from the liquid pool (100-500 μs). Atomic Al and AlO were observed with optical emission spectroscopy at different ratios during the entire lifetime of the event, verifying the formation of oxidized Al vapor upon its interaction with air. Morphological and compositional characterization confirmed surface oxidation and material re-solidification in the form of protrusions produced during the irradiation process. This work provides insights into the complex physical and chemical mechanisms of single-pulse ablation in the sub-millisecond laser pulse regime, which are critically important for parameter optimization in a variety of laser processing, microfabrication, and deposition applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast imaging of laser ablation of cerium: Dependence of plasma plume dynamics and structure on native oxide growth

We have imaged the evolution of plasma following nanosecond pulsed laser ablation of cerium in air with sub-10 ns resolution. We find the ablated plasma plume expansion and shape to be strongly dependent on the time after mechanical polishing of the sample surface. After an initial shock front common to both new and aged samples (velocities up to 16 km s ₋1 ), we observe a second front that is relatively localized to the surface vicinity of newly polished samples, but in the case of older samples it moves outward at velocities of up to 4 km s ₋1 . We attribute this behavior to the formation and growth of a native oxide layer on the order of hours after polishing. These results demonstrate that plasma imaging can be used to diagnose the presence of, and evaluate the extent of, thin surface oxides or other compounds that form soon after exposure to some atmosphere. These findings also highlight the need to explicitly consider the presence of such overlayers when modeling laser/metal interaction, when making measurements of vapor phase chemistry, and when analyzing the composition, phase, and morphology of solid particulates formed after the ablation of reactive metals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an ultrafast wide-field microscope for single-shot laser-driven shock and ablation studies

We build an ultrafast wide-field microscope that captures single-shot events at near-optical diffraction limit for time-resolved studies of ablation and shock compression. Here, we provide insights on how the imaging and spectroscopic modalities of our single-shot microscope are impacted by the depth of field of a microscope objective. At high spatial resolution, the depth of field can critically impede these experiments and novel strategies must be implemented to acquire high-quality optical micrographs at high throughput. Here, we highlight how custom lithography-prepared samples enable us to rectify optical artifacts that arise during sample motion. With a complete knowledge of how the mechanical and optical components couple together, we can then extract critical spatial and temporal features of our ablation and shock compression experiments. For example, during the ablation processes, we show that shock waves created in metal thin films form Newton’s interference rings, whose evolution can be recorded with picosecond temporal resolution and at near optical diffraction-limit resolution.

Ultrafast microscopy↗

Optimizing ablator thickness for laser shock experiments

In laser shock experiments, a well-defined, flat-top shock wave at the ablator/sample interface is important for accurately probing material response under uniaxial strain compression. However, the relationship between the ablator thickness and the resulting shock wave characteristics is insufficiently understood, limiting the ability to design optimal experiments. To address this need, we conducted a systematic experimental study using a 100 J laser to shock-compress polyimide ablators to peak stresses ranging from 20.4 to 111.6 GPa. Laser interferometry diagnostics measured the transmitted wave profiles at the ablator/sample interface, consistently showing a single jump followed by a constant peak state before the arrival of release waves. Here, by analyzing shock transit time, flat-top duration, and stress, our results establish a framework for selecting ablator thickness to maximize the flat-top duration, improving the precision and reproducibility of laser shock experiments.

design of experiments↗

Spectral features of colloidal solutions of elongated gold nanoparticles produced by laser ablation in aqueous solutions

The extinction spectra of colloidal solutions of gold nanoparticles produced by laser ablation in water and aqueous solutions of salts using two near-IR lasers with pulse durations of 200 ns and 1 ps are experimentally investigated. The extinction spectrum of the particles formed by ablation in aqueous solutions is characterised by enhanced optical density in the red and IR regions. This feature is due to the formation of elongated gold nanoparticles, as confirmed by transmission electron microscopy. The surface images of a gold target subjected to multipulse laser ablation exhibit micron and submicron structures. (nanophotonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ studies of a molten metal anode ablation in a nearly atmospheric pressure DC arc

A DC arc with a meltable metal anode in a near-atmospheric pressure hydrocarbon gas is an emerging method for producing single-walled carbon nanotubes (SWCNTs). In these systems, evaporation of the molten metal anode determines the formation of catalyst seed particles needed for SWCNT growth, and therefore, should be monitored, controlled, and optimized. Evaluating the anode ablation rate by weighing the anode before and after a synthesis run is unfeasible due to anode carburization in the hydrocarbon atmosphere. To overcome this, we implemented a high-speed, 2D, 2-color pyrometry for reliable temperature measurements of the molten anode in a DC arc. The obtained temperature fields were used to calculate the anode ablation rates. Results showed the importance of resolving the arc and molten pool dynamics, as well as addressing the issue of reflections. Furthermore, significant changes in ablation rates were revealed upon addition of CH 4 , which must be considered when scaling up the production of SWCNTs.

Marangoni↗

Performance of Conformable Phenolic Impregnated Carbon Ablator in Aerothermal Environments

Conformable Phenolic Impregnated Carbon Ablator, a cousin of Phenolic Impregnated Carbon Ablator (PICA), was developed at NASA Ames Research Center as a lightweight thermal protection system under the Fundamental Aeronautics Program. PICA is made using a brittle carbon substrate, which has a very low strain to failure. Conformable PICA is made using a flexible carbon substrate, a felt in this case. The flexible felt significantly increases the strain to failure of the ablator. PICA is limited by its thermal mechanical properties. Future NASA missions will require heatshields that are more fracture resistant than PICA and, as a result, NASA Ames is working to improve PICA's performance by developing conformable PICA to meet these needs. Research efforts include tailoring the chemistry of conformable PICA with varying amounts of additives to enhance mechanical properties and testing them in aerothermal environments. This poster shows the performance of conformable PICA variants in arc jets tests. Some mechanical and thermal properties will also be presented.

ablative materials↗

Thermal Ablation Modeling for Silicate Materials

A thermal ablation model for silicates is proposed. The model includes the mass losses through the balance between evaporation and condensation, and through the moving molten layer driven by surface shear force and pressure gradient. This model can be applied in ablation simulations of the meteoroid or glassy Thermal Protection Systems for spacecraft. Time-dependent axi-symmetric computations are performed by coupling the fluid dynamics code, Data-Parallel Line Relaxation program, with the material response code, Two-dimensional Implicit Thermal Ablation simulation program, to predict the mass lost rates and shape change. For model validation, the surface recession of fused amorphous quartz rod is computed, and the recession predictions reasonably agree with available data. The present parametric studies for two groups of meteoroid earth entry conditions indicate that the mass loss through moving molten layer is negligibly small for heat-flux conditions at around 1 MW/cm(exp. 2).

Ablators↗

Cyanate Ester and Phthalonitrile Impregnated Carbon Ablative TPS

Phenolic resin has extensive heritage as a TPS (Thermal Protection Systems) material, however, alternative resin systems such as Cyanate Ester and Phthalonitrile may offer improved performance compared to state-of-the-art phenolic resin. These alternative resin systems may have higher char yield, higher char strength, lower thermal conductivity and improved mechanical properties. In current work at NASA Ames alternative resin systems were uniformly infused into fibrous substrates and preliminary properties characterized. The density of the cyanate ester infused in fibrous substrate ranged from 0.25-0.3 grams per cubic centimeter compared to PICA (Phenolic resin impregnated carbon ablative) having a density of approximately 0.25 grams per cubic centimeter. The density of Phthalonitrile varies from 0.22-0.25 grams per cubic centimeter. Initial formulations of these new resin systems were recently tested at the LARC HyMETs (Hypersonic Materials Environmental Test System) facility to evaluate their performance and data such as back face temperature, char yield, and recession are compared to PICA. Cyanate Ester and Phthalonitrile impregnated carbon ablative samples showed comparable performance to phenolic resin impregnated carbon ablative samples.

Polymer↗

Alternative High Performance Polymers for Ablative Thermal Protection Systems

Ablative thermal protection systems are commonly used as protection from the intense heat during re-entry of a space vehicle and have been used successfully on many missions including Stardust and Mars Science Laboratory both of which used PICA - a phenolic based ablator. Historically, phenolic resin has served as the ablative polymer for many TPS systems. However, it has limitations in both processing and properties such as char yield, glass transition temperature and char stability. Therefore alternative high performance polymers are being considered including cyanate ester resin, polyimide, and polybenzoxazine. Thermal and mechanical properties of these resin systems were characterized and compared with phenolic resin.

Ablator↗

Multi-Scale Modeling of Low-Density Carbon-Phenolic Ablators

Protecting a spacecraft during atmospheric entry is one of highest risk factors that needs to be mitigated during design of a space exploration mission. At entry speeds from space, air turns into high-temperature plasma, and spacecraft Thermal Protection Systems (TPS) are needed to protect the vehicle payload. Modern successful material architectures of spacecraft shields use a porous carbon fiber substrate impregnated with phenolic as an ablator material. In the lecture, efforts to build a Predictive Material Modeling framework for porous ablators from micro-scale to macro-scale will be presented. Several numerical methods and techniques will be summarized that use voxelized images to compute geometrical properties of the porous substrate. These computed properties include porosity, specific surface area and tortuosity that are otherwise indirectly measured through experimental techniques. Direct simulation Monte Carlo (DSMC), a particle-based method for approximating the Boltzmann equation, is used to compute the permeability coefficient of the porous substrate based on its digitized representation. The method computes the flow within the microstructure, where the size of the pores may approach the mean-free-path of the flow. Finally, a high-fidelity model implemented in PATO (Porous-material Analysis Toolbox) is discussed, and some examples of ablative material response are presented, including for the first time 3D simulations of the full tiled heat shield for the Mars Science Laboratory (MSL) capsule.

Ablators↗

Qualification of Domestic Lyocell Based Phenolic Impregnated Carbon Ablator (PICA-D) for NASA Missions

Phenolic Impregnated Carbon Ablator (PICA) is a low-density ablator that has been used as the planetary entry heatshield for several NASA missions since the late 90’s. Its low density and efficient performance characteristics have proven effective for use from Discovery to Flag-ship class missions, from Sample Return missions such as Stardust, OSIRIS-REx to large Mars Lander missions such as Mars Science Lab (MSL) and Mars 2020. The rayon-based carbon precursor raw material used in PICA preform manufacturing has experienced multiple supply chain issues. The challenge involved in finding a replacement fiber source is in processing as well as in the final performance of the ablator. Each replacement necessitates the requalification of the PICA. This has happened at least twice in the past 25 years, and a third substitution is now needed. Due to the obsolescence of the input foreign rayon fiber source, a new variant of PICA has been developed using a domestic rayon-like fiber source, Lyocell. Due to its flight heritage and proven capability, PICA is baselined as the Thermal Protection System (TPS) for Dragonfly and Mars Sample Return Sample Retrieval Lander mission and is being considered for the backshell of the Mars Sample Return Earth Entry System. All three missions are due to be launched between 2026 and 2028. The challenge this time is to ensure the PICA made with domestic material is a suitable replacement to the heritage PICA used in MSL and Mars 2020 so that the design of the heatshield can be matured without much risk. Results are presented from the recent efforts of 22 PICA-D billets that were Lot Acceptance Tested. Thermal, mechanical, and representative environment arc-jet tests have been conducted. Testing of PICA-Domestic (PICA-D) indicates very comparable performance with respect to “heritage” PICA materials and thus PICA-D is expected to be a sustainable and nearly a “drop-in” replacement solution for future NASA missions.

PICA↗

Simulating Meteor Ablation at the Hypersonic Materials Environmental Test System

The ablation mechanisms of stony meteorite material and a terrestrial analog were investigated at the Hypersonic Materials Environmental Test System (HyMETS) facility at NASA’s Langley Research Center. The primary analyte (Tamdakht-H5) and arc-jet test conditions were chosen to simulate the entry of an ordinary chondrite through the Earth’s mesosphere. Basalt was selected to compare the meteorite response against material with enhanced polymerization and an elevated concentration of volatile species. The initial ablation process for each material commences with the vaporization of volatile species and germination of a viscous melt layer on the stagnation surface. However, each material exhibited distinct mass loss mechanisms, with basalt recessing at twice the rate of Tamdakht. Inspection of high-speed video and chemical analysis of the post-test melt layer suggests the dominant mode of mass loss of Tamdakht is expressed through the vaporization of volatile compounds. Vaporization rates of Tamdakht are 18x higher than basalt under the most severe test conditions which provides enhanced thermal shielding. Furthermore, Tamdakht produces a relatively stable melt flow, as evidenced by perpetual growth at the sidewall and the exiguous detachment of molten material into the flow. The ablation mechanism of basalt is markedly different from Tamdakht and is governed by volatile species in the virgin material. The dominant mode of mass loss for basalt is attributed to the detachment of large sections of the stagnation surface near the edge radius. An additional but subordinate mode of mass loss is assigned to the removal of melt flow as it passes over the edge radius, where shear forces overcome the rheological properties of the molten matter. Finally, mechanistic details will be discussed in terms of designing future test campaigns, developing meteorite-based materials response models, and impacting the broader scope of the Asteroid Threat Assessment Project (ATAP).

Meteor Ablation↗

Identification and Study of Validation Level Test Cases for Computational Modeling of Non-Charring Ablators

Computational modeling of Thermal Protection System (TPS) materials, used for aerospace applications, provides numerous advantages in preliminary selection and design of a heatshield material and shape for atmospheric entry vehicles. However, to serve as a reliable tool for prediction of material thermal and ablative behavior, the modeling approach needs to be validated against real experimental and flight data, preferably at a range of applied conditions. The validation study is typically very complex as it requires reliable measured data not only for the material thermal response and surface recession, but also well characterized environmental conditions. The validation problem becomes even more complex when the material thermal response is dictated by multi-physics effects such as solid conduction, in-depth thermal decomposition, pyrolysis gas flow and chemical reactions. The multi-physics effects complicate not only the modeling effort, but also the experimental measurement for validation of various aspects of the highly coupled problem. In this study, an attempt is made to identify suitable experimental data that could serve as a source for validation of material thermal response modeling tools. To reduce the computational complexity, this study focuses only on non-charring ablators, where the material thermal response could be modeled with a single governing equation for solid conduction and the ablation is limited only to the surface of the material. With a well characterized and publicly available experimental data being sparse, the study is limited in presenting test cases for only three materials: camphor, graphite and FiberForm® in the sequence of increased modeling complexity. Graphite is a commonly used TPS material for aerospace applications, both for leading edges of high-speed vehicles and internal insulation of solid rocket motors. FiberForm® is a porous carbon pre-form used in preparation of the well known PICA material Tran et al. [1996]. Inclusion of camphor into the list is conditioned with the relative simplicity in modeling the material thermal and chemical response and the low-enthalpy flow environment. In addition, camphor has been used as a simple test material for study of flow transition behavior by Stock and Ginoux [1973] and assessment of a heatshield shape change at flight relevant conditions by Rotondi et al. [2022]. In this work, the identified experimental data was extracted from the public literature and test cases that yet have been published. As it was found from the review, not a single test case contains an exhaustive set of data that would validate every aspect of the material physics. However, in the data collected, various aspects of the material behavior can be still validated, such as surface and in-depth temperature, amount of recession and a shape change. The identified experimental data for each case is accompanied with a characterized flow environment and simulated boundary conditions predicted by a Data-Parallel Line Relaxation (DPLR) code Wright et al. [1998]. In addition, material thermal response numerical simulations in each test case are performed with Kentucky Aerothermodynamics and Thermal Response System (KATS-MR) Zibitsker et al. [2022] providing a comparative study and a sanity check for the proposed validation data. Sample results from the performed numerical study are shown below. Figure 1 shows distribution of surface heat flux and pressure values on a hemi-cylinder model made of FiberForm® and tested in HyMETS arc-jet facility. The results are shown for the high pressure condition among the two tests. Flow simulation was performed with DPLR code on a quarter of original geometry. In the figure, the quarter shape was mirrored across zx and xy planes to show the complete distribution. Figure 2 shows the material response results for the high pressure case (7500 Pa), simulated with KATS-MR and a comparison to the experimental data for the surface temperature and shape shape. The simulation was performed on a 2-D slice, extracted in the xy plane at the middle of the sample. Figure 3 shows the material response simulation for the low pressure case (3500 Pa) and a comparison to the experimental data for surface temperature and shape change.

ablation↗

Flame Deflector Ablation Analysis based on Artemis 1 Launch Environment

This paper presents the updated ablative analysis methods used to determine Artemis 1 launch load environment on the flame deflector for the design based on Artemis I Assessments. The flame trench under Pad 39B at Kennedy Space Center contains a flame deflector to safely divert the exhaust plume from the SLS rocket during launch. During launch of Artemis I the refurbished flame trench and the new flame deflector experienced peak temperatures of over 2,000 degrees Fahrenheit (over 1,000 degrees Celsius) for several seconds. These extreme conditions caused ablation (material removal) from the steel plates. This paper contains flame deflector heat flux values for design based on Artemis I assessment. Post flight images of the flame deflector are shown along with “Pre vs Post” Flame Deflector scan image to measure the post flight deviations. Using COMSOL, a method to calculate a heat flux value due to measured deviations in the deflector plates caused by ablation is shown.

Artemis I↗

Bayesian Inference and the Effects of Varying Uncertainty Models in Charring Ablator Calibration and Uncertainty Quantification Problems

The Mars Science Laboratory (MSL) vehicle utilized a heat shield constructed from NASA’s Phenolic-Impregnated Carbon Ablator (PICA) material to protect the main structure from the high enthalpy environment encountered during hypersonic atmospheric entry. During the vehicle’s descent through Martian atmosphere, multiple thermocouples embedded within the heat shield captured in-depth material temperature data that allow for studies to be conducted on current material response reconstruction tools. In the present work, material temperature data obtained from thermocouples within the MISP-4 plug (MEDLI (Mars Science Laboratory Entry, Descent, and Landing Instrument) Integrated Sensor Plug) are utilized in the calibration of Theoretical Ablative Composite for Open Testing (TACOT) model parameters in conjunction with NASA’s Porous material Analysis Toolbox (PATO) through Bayesian inference where uncertainty due to parametric, modeling, and experimental sources is simultaneously quantified. Prior to the study, a sensitivity analysis is performed through computation of the robust Sobol indices in an effort to study the relationship between input space and model response and to reduce the dimensionality of the statistical inverse problem. The Bayesian inference methodology necessitates an a-priori choice to be made for the uncertainty model for which numerous possibilities are available. Across most works, however, only basic additive or multiplicative models are utilized with pre-defined magnitudes of uncertainty based on a-priori knowledge or to-be-calibrated multipliers of static covariance matrix structures. The present effort explores the effects of informed uncertainty models, ones with temporal dependence that are simultaneously calibrated through Bayesian inference, on calibrated results for parameters that make up the uncertain input space.