Developing Performance Cost Index Targets for ASHRAE Standard 90.1 Appendix G – Performance Rating Method

Appendix G, the Performance Rating Method in ASHRAE Standard 90.1 has been updated to make two significant changes for the 2016 edition, to be published in October of 2016. First, it allows Appendix G to be used as a third path for compliance with the standard in addition to rating beyond code building performance. This prevents modelers from having to develop separate building models for code compliance and beyond code programs. Using this new version of Appendix G to show compliance with the 2016 edition of the standard, the proposed building design needs to have a performance cost index (PCI) less than targets shown in a new table based on building type and climate zone. The second change is that the baseline design is now fixed at a stable level of performance set approximately equal to the 2004 code. Rather than changing the stringency of the baseline with each subsequent edition of the standard, compliance with new editions will simply require a reduced PCI (a PCI of zero is a net-zero building). Using this approach, buildings of any era can be rated using the same method. The intent is that any building energy code or beyond code program can use this methodology and merely set the appropriate PCI target for their needs. This report discusses the process used to set performance criteria for compliance with ASHRAE Standard 90.1-2016 and suggests a method for demonstrating compliance with other codes and beyond code programs.

99 GENERAL AND MISCELLANEOUS↗

Developing Performance Cost Index Targets for ASHRAE Standard 90.1 Appendix G – Performance Rating Method - Rev.1

Appendix G, the Performance Rating Method in ASHRAE Standard 90.1 has been updated to make two significant changes for the 2016 edition, to be published in October of 2016. First, it allows Appendix G to be used as a third path for compliance with the standard in addition to rating beyond code building performance. This prevents modelers from having to develop separate building models for code compliance and beyond code programs. Using this new version of Appendix G to show compliance with the 2016 edition of the standard, the proposed building design needs to have a performance cost index (PCI) less than targets shown in a new table based on building type and climate zone. The second change is that the baseline design is now fixed at a stable level of performance set approximately equal to the 2004 code. Rather than changing the stringency of the baseline with each subsequent edition of the standard, compliance with new editions will simply require a reduced PCI (a PCI of zero is a net-zero building). Using this approach, buildings of any era can be rated using the same method. The intent is that any building energy code or beyond code program can use this methodology and merely set the appropriate PCI target for their needs. This report discusses the process used to set performance criteria for compliance with ASHRAE Standard 90.1-2016 and suggests a method for demonstrating compliance with other codes and beyond code programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancements to ASHRAE Standard 90.1 Prototype Building Models

Since the last publication of the commercial prototype building models, PNNL has made numerous enhancements to the original prototype models compliant with the 2004, 2007, and 2010 editions of Standard 90.1. Those enhancements are described here and were made for several reasons: (1) to change or improve prototype design assumptions; (2) to improve simulation accuracy; (3) to improve simulation infrastructure; and (4) to add additional detail to the models needed to capture certain energy impacts from Standard 90.1 improvements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Analysis of ASHRAE Standard 90.1-2022

These data dashboards present the data and findings from PNNL's detailed analysis of ASHRAE Standard 90.1 on US commercial new construction buildings. The dashboards support simulation-based assessment of U.S. commercial buildings compliant with ASHRAE Standard 90.1-2004, 2007, 2009, 20210, 2013, 2016, 2019, and 2022.

Nambiar, Chitra↗

A Stable Whole Building Performance Method for Standard 90.1-Part II

In May of 2013 we introduced a new approach for compliance with Standard 90.1 that was under development based on the Performance Rating Method of Appendix G to Standard 90.11. Since then, the approach has been finalized through Addendum BM to Standard 90.1-2013 and will be published in the 2016 edition of the Standard. In the meantime, ASHRAE has published an advanced copy of Appendix G including Addendum BM and several other addenda so that software developers and energy program administrators can get a preview of what is coming in the 2016 edition of the Standard2. This article is an update on Addendum BM, summarizes changes made to the original concept as introduced in May of 2013, and provides an approach for developing performance targets for code compliance and beyond code programs.

Addendum BM↗

End-Use Analysis of ASHRAE Standard 90.1-2019

This article summarizes the analysis conducted by Pacific Northwest National Laboratory (PNNL), assessing expected end-use energy consumption in commercial buildings, based on recent editions of the model energy code for the commercial sector, ANSI/ASHRAE/IES Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings. The results represent simulated energy use based on) Commercial Prototype Building Models1 across representative climate zones in the United States, as defined by Standard 90.1. PNNL examined the resulting simulation outputs to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Weighting Factors for the Commercial Building Prototypes Used in the Development of ANSI/ASHRAE/IESNA Standard 90.1-2010

Detailed construction data from the McGraw Hill Construction Database was used to develop construction weights by climate zones for use with DOE Benchmark Buildings and for the ASHRAE Standard 90.1-2010 development. These construction weights were applied to energy savings estimates from simulation of the benchmark buildings to establish weighted national energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Conversation on Standard 90.1-2016

The roundtable discussion: A Conversation on Standard 90.1-2016, highlights some of the major changes one can expect to see in building envelope, mechanical system, and lighting requirements. In addition, the article highlights a new performance-based compliance path, climate zone revisions, and the strategic initiatives resulting in the new format. This roundtable was conducted by ASHRAE Journal with Drake Erbe, Member ASHRAE; Dick Lord, Fellow ASHRAE; Len Sciarra, AIA, Member ASHRAE; Eric Richman, Member ASHRAE; Michael Rosenberg, Member ASHRAE; Rahul Athalye, Associate Member ASHRAE; Bing Liu, P.E., Member ASHRAE; and Jason Glazer, P.E., Member ASHRAE.

ASHRAE↗

Demand or No Demand: Electrical Rates for Standard 90.1-2010

ASHRAE is developing the 2010 version of Standard 90.1 with the goal of reaching 30% savings beyond the 2004 edition of the standard. Economics are used to inform the process of setting criteria and the assumed electricity rates are crucial to these calculations. Previously the committee used national average electrical rates in the criteria setting but recently a number of voices have been heard in support of using demand rates instead. This article explores the issues surrounding the use of a pure consumption rate vs. the use of demand rates and looks at the implications for HVAC equipment efficiency.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Opportunity Analysis from Progress Indicator Results for ASHRAE Standard 90.1-2013

This report and an accompanying spreadsheet (PNNL 2014a) compile the end use building simulation results for prototype buildings throughout the United States. The results represent he energy use of each edition of ASHRAE Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings (ASHRAE 2004, 2007, 2010, 2013). PNNL examined the simulation results to determine how the remaining energy was used.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Opportunity Analysis Based on Standard 90.1-2016

This report summarizes technical analysis conducted by Pacific Northwest National Laboratory (PNNL), assessing expected end-use energy consumption in commercial buildings, based on recent editions of the model energy code for the commercial sector, ANSI/ASHRAE/IES Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings.