Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “47 OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Development of spinning-disk solid sample delivery system for high-repetition rate x-ray free electron laser experiments

X-ray free-electron lasers (XFELs) deliver intense x-ray pulses that destroy the sample in a single shot by a Coulomb explosion. Experiments using XFEL pulse trains or the new generation of high-repetition rate XFELs require rapid sample replacement beyond those provided by the systems now used at low repletion-rate XFELs. We describe the development and characterization of a system based on a spinning disk to continuously deliver a solid sample into an XFEL interaction point at very high speeds. We tested our system at the Linac Coherent Light Source and European XFEL hard x-ray nano-focus instruments, employing it to deliver a 25 μm copper foil sample, which can be used as a gain medium for stimulated x-ray emission for the proposed x-ray laser oscillator.

47 OTHER INSTRUMENTATION↗

DrEVL Radiometer Calibration

This report details the calibration procedures that were used for the spectral and radiometric part of the DrEVL radiometers. Our goal was to develop a highly repeatable and low cost spectral radiometer that could be deployed at numerous sites to collect a catalog of lightning data. Maximizing the re-usability of that data requires a well-calibrated instrument.

47 OTHER INSTRUMENTATION↗

Instrument for spatially resolved, temperature-dependent electrochemical impedance spectroscopy of thin films under locally controlled atmosphere

We demonstrate an instrument for spatially resolved measurements (mapping) of electrochemical impedance under various temperatures and gas environments. Automated measurements are controlled by a custom LabVIEW program, which manages probe motion, sample motion, temperature ramps, and potentiostat functions. Sample and probe positioning is provided by stepper motors. Dry or hydrated atmospheres (air or nitrogen) are available. The configurable heater reaches temperatures up to 500 °C, although the temperature at the sample surface is moderated by the gas flow rate. The local gas environment is controlled by directing flow toward the sample via a glass enclosure that surrounds the gold wire probe. Software and hardware selection and design are discussed. Reproducibility and accuracy are quantified on a Ba(Zr,Y)O 3-δ proton-conducting electrolyte thin film synthesized by pulsed laser deposition. The mapping feature of the instrument is demonstrated on a compositionally graded array of electrocatalytically active Ba(Co,Fe,Zr,Y)O 3-δ thin film microelectrodes. The resulting data indicate that this method proficiently maps property trends in these materials, thus demonstrating the reliability and usefulness of this method for investigating electrochemically active thin films.

47 OTHER INSTRUMENTATION↗

OrganiCam: a lightweight time-resolved laser-induced luminescence imager and Raman spectrometer for planetary organic material characterization

OrganiCam is a laser-induced luminescence imager and spectrometer designed for standoff organic and biosignature detection on planetary bodies. OrganiCam uses a diffused laser beam (12° cone) to cover a large area at several meters distance and records luminescence on half of its intensified detector. The diffuser can be removed to record Raman and fluorescence spectra from a small spot from 2 m standoff distance. OrganiCam’s small size and light weight makes it ideal for surveying organics on planetary surfaces. Here, we have designed and built a brassboard version of the OrganiCam instrument and performed initial tests of the system.

47 OTHER INSTRUMENTATION↗

Integrated multi-wavelength microscope combining TIRFM and IRM modalities for imaging cellulases and other processive enzymes

We describe a multimodal microscope for visualizing processive enzymes moving on immobilized substrates. The instrument combines interference reflection microscopy (IRM) with multi-wavelength total internal reflectance fluorescence microscopy (TIRFM). The microscope can localize quantum dots with a precision of 2.8 nm at 100 frames/s, and was used to image the dynamics of the cellulase, Cel7a interacting with surface-immobilized cellulose. The instrument, which was built with off-the-shelf components and is controlled by custom software, is suitable for tracking other degradative enzymes such as collagenases, as well as motor proteins moving along immobilized tracks.

09 BIOMASS FUELS↗

Single-Channel Tricolor Absorption Photometer (STAP) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s aerosol counting, composition, extinction, and sizing system (ACCESS) includes a base module (9400), a filter sampler (9401), an advanced mixing condensation particle counter (MCPC, 9403), a miniaturized optical particle counter (MOPC, 9405), and a single-channel tricolor absorption photometer (STAP, 9406). This handbook describes the principles and operations of the single-channel tricolor absorption photometer, Model 9406.

47 OTHER INSTRUMENTATION↗

Assessing Options for Particulate Measurement Tools to Advance Wood Heaters (CRADA Final Report)

For approximately 40 years, particulate matter (PM) from residential wood heaters has been certified in North America using an EPA dilution tunnel with a filter-based gravimetric measurement. While reasonably repeatable, this approach reports only a single value for the entire burn sequence and does not provide information on PM at different points within the sequence, which would support improved wood heater designs. PM monitors that report with high time resolution offer a potential solution, but their performance for various types of heaters and across heater operating conditions has not been extensively evaluated. In this 18-month collaborative project, the Hearth, Patio & Barbecue Association (HPBA) and Lawrence Berkeley National Laboratory (LBNL) tested five continuous PM instruments spanning three measurement principles—light-scattering, inertial mass (TEOM), and triboelectric—against gravimetric and size-resolved references on three residential heater types (cordwood, catalytic cordwood, and pellet) across startup, high-burn, and low-burn operating phases.

42 ENGINEERING↗

Quantifying Background Magnetic Fields at Marine Energy Sites: Challenges and Recommendations

Unknowns around the environmental effects of marine renewable energy have slowed the deployment of this emerging technology worldwide. Established testing methods are necessary to safely permit and develop marine energy devices. Magnetic fields are one potential cause of environmental effects and are created when electricity is generated and transmitted to shore. Further, the existing variation of the background magnetic field at sites that may be developed for marine energy is largely unknown, making it difficult to assess how much additional stress or impact the anthropogenic magnetic field may have. This study investigates two instruments for their ability to characterize the background magnetic fields at a potential marine energy site in Sequim Bay, WA. Based on this evaluation, this study recommends an Overhauser magnetomer for assessing the background magnetic field and demonstrates the use of this sensor at a potential marine energy site.

47 OTHER INSTRUMENTATION↗

Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure

Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high-Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.

36 MATERIALS SCIENCE↗

Identifying Suspect Instrument Intervals Using Midnight Noise Time Histories

With an intense work ethic, and high levels of devotion to their craft, seismologists continue to battle the elements and wrestle with complex logistics in their efforts to field instrumentation over the entire globe. We are fortunate to see data volumes accelerating in size, and quality continuing to improve; for example, universal timing issues can now be considered rare. However, instrument response issues are still common, and can hinder research that seeks to understand amplitudes of seismic wavefields. We are interested in using the accumulations of seismic data to develop models that will predict high frequency (0.2-20 Hz, and higher) signal amplitudes for explosion monitoring purposes over broad areas, which requires large data sets and extensive quality control. To identify response and station health issues, we have collected noise time histories for global seismic data, focusing on measurements near (but not restricted to) midnight to eliminate diurnal variations, and have manually determined time intervals that appear inconsistent with background behavior. We assign descriptive labels, but do not attempt to diagnose causes. We use these intervals to discard data. To date, we have examined 39,260 channels from 11,105 stations, heavily weighted toward IRIS holdings, dates through 2017 (depending on station, roughly the date we started our manual review), bands between 1 and 8 Hz, finding 24,733 anomalous time intervals. The great majority (90%) of these intervals appear to be shifts of constant offset, often bounded by times of known instrument changes, likely the result of poor documentation of response parameters at one of many stages between the field and the plotter. We hope these results can be of use to our colleagues, and would encourage community efforts to diagnose anomalous behavior, and fix poor responses. We also hope these results will support automation efforts, including application of supervised learning techniques.

47 OTHER INSTRUMENTATION↗

Simultaneous ambient pressure x-ray photoelectron spectroscopy and grazing incidence x-ray scattering in gas environments

We have developed an experimental system to simultaneously measure surface structure, morphology, composition, chemical state, and chemical activity for samples in gas phase environments. This is accomplished by simultaneously measuring x-ray photoelectron spectroscopy (XPS) and grazing incidence x-ray scattering in gas pressures as high as the multi-Torr regime while also recording mass spectrometry. Scattering patterns reflect near-surface sample structures from the nano-scale to the meso-scale, and the grazing incidence geometry provides tunable depth sensitivity of structural measurements. Scattered x rays are detected across a broad range of angles using a newly designed pivoting-UHV-manipulator for detector positioning. At the same time, XPS and mass spectrometry can be measured, all from the same sample spot and under ambient conditions. To demonstrate the capabilities of this system, we measured the chemical state, composition, and structure of Ag-behenate on a Si(001) wafer in vacuum and in O 2 atmosphere at various temperatures. These simultaneous structural, chemical, and gas phase product probes enable detailed insights into the interplay between the structure and chemical state for samples in gas phase environments. The compact size of our pivoting-UHV-manipulator makes it possible to retrofit this technique into existing spectroscopic instruments installed at synchrotron beamlines. Because many synchrotron facilities are planning or undergoing upgrades to diffraction limited storage rings with transversely coherent beams, a newly emerging set of coherent x-ray scattering experiments can greatly benefit from the concepts we present here.

47 OTHER INSTRUMENTATION↗

A formaldehyde and nitrogen dioxide toxics monitor for environmental justice

DOE’s Integrated Field Laboratories (IFLs) require a vast array of measurements to measure urban air quality. Nitrogen dioxide (NO2) and formaldehyde (HCHO) are ubiquitous pollutants with numerous sources, most notably vehicle exhaust. High-spatial density measurements are critical to understanding how certain neighborhoods are more adversely impacted by pollutants. This report describes the results of a Phase I SBIR project to develop and demonstrate a rapid, affordable, low-power monitor to provide high spatial resolution mobile measurements of formaldehyde and nitrogen dioxide at street-level, where people live and walk. The spatial density will be achieved via rapid measurements on a mobile platform. This sensor will quantify spatial disparities in cities of the toxics, HCHO and NO2, as well as carbon monoxide and carbon dioxide for better source identification. These species are detected in the mid infrared by laser absorption spectroscopy, and fiberoptics are used. Tasks accomplished include identification and testing of the appropriate spectroscopic regions; coupling of laser light into a fiberoptic system; development of software to control miniature electronics to scan and control two lasers simultaneously; coupling of the mid infrared fiber into a multipass cell for enhanced pathlength and sensitivity; characterization of sources of instrument noise; and design work for a Phase II prototype.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EXPANSE: A time-of-flight EXPanded Angle Neutron Spin Echo spectrometer at the Second Target Station of the Spallation Neutron Source

EXPANSE, an EXPanded Angle Neutron Spin Echo instrument, has been proposed and selected as one of the first suite of instruments to be built at the Second Target Station of the Spallation Neutron Source at the Oak Ridge National Laboratory. This instrument is designed to address scientific problems that involve high-energy resolution (neV– μeV) of dynamic processes in a wide range of materials. The wide-angle detector banks of EXPANSE provide coverage of nearly two orders of magnitude in scattering wavenumbers, and the wide wavelength band affords approximately four orders of magnitude in Fourier times. This instrument will offer unique capabilities that are not available in the currently existing neutron scattering instruments in the United States. Specifically, EXPANSE will enable direct measurements of slow dynamics in the time domain over wide Q-ranges simultaneously and will also enable time-resolved spectroscopic studies. The instrument is expected to contribute to a diverse range of science areas, including soft matter, polymers, biological materials, liquids and glasses, energy materials, unconventional magnets, and quantum materials.

47 OTHER INSTRUMENTATION↗

Chapter 10 Supplement. Environmental Monitoring Technologies and Techniques for Detecting Interactions of Marine Animals with Marine Renewable Energy Devices

The Chapter 10 Supplementary Material provides information on instrument classes used for monitoring marine renewable energy devices such as passive acoustics, active acoustics, and video cameras. It also describes the applications and challenges of video cameras, and provides a technical glossary related to monitoring terminologies.

47 OTHER INSTRUMENTATION↗

Instrumentation and Samples (CRADA Final Report)

Instruments which are categorized as shared user instruments at the National Laboratory of the Rockies (NLR) will be utilized for ongoing technical work. Samples will be provided by University of Colorado Boulder (CU) and thus no need for materials at NLR is anticipated.

(Ga1- xZnx)(N1-xOx)↗

Multi-extreme conditions at the Second Target Station

Three concepts for the application of multi-extreme conditions under in situ neutron scattering are described here. The first concept is a neutron diamond anvil cell made from a non-magnetic alloy. It is shrunk in size to fit existing magnets and future magnet designs and is designed for best pressure stability upon cooling. This will allow for maximum pressures above 10 GPa to be applied simultaneously with (steady-state) high magnetic field and (ultra-)low temperature. Additionally, an implementation of miniature coils for neutron diamond cells is presented for pulsed-field applications. The second concept presents a set-up for laser-heating a neutron diamond cell using a defocused CO 2 laser. Cell, anvil, and gasket stability will be achieved through stroboscopic measurements and maximum temperatures of 1500 K are anticipated at pressures to the megabar. The third concept presents a hybrid levitator to enable measurements of solids and liquids at temperatures in excess of 4000 K. This will be accomplished by a combination of bulk induction and surface laser heating and hyperbaric conditions to reduce evaporation rates. The potential for deployment of these multi-extreme environments within this first instrument suite of the Second Target Station is described with a special focus on VERDI, PIONEER, CENTAUR, and CHESS. Furthermore, considerations for deployment on future instruments, such as the one proposed as TITAN, are discussed. Overall, the development of these multi-extremes at the Second Target Station, but also beyond, will be highly advantageous for future experimentation and will give access to parameter space previously not possible for neutron scattering.

47 OTHER INSTRUMENTATION↗

Creating a Detector Response Matrix for the Micro-Calorimeter

To better understand the results from the micro calorimeter, a detector response matrix (DRM) was generated. This will allow to predict source responses, which in turn will improve the confidence in the instrument. To generate a DRM, the simulation package Rapid Adaptable Multi-threaded Particle and Radiation Transport Simulation (RAMPART) that utilizes underlying Geant4 libraries for particle transport was used to generate the simulation. A flat energy input spectrum ranging from 0 keV to 3000 keV was used to generate the response. 37 x 10 9 particles were simulated. In this report, the details and findings are presented.

47 OTHER INSTRUMENTATION↗

Design, calibration, and performance of a uniaxial pressure cell for neutron scattering studies of quantum magnetism

Here we provide an overview of a pressure cell designed to apply uniaxial pressure to single crystals for the study, by neutron scattering techniques, of strongly correlated magnetic systems and, in particular, quantum magnets. A detailed overview of the pressure cell components, their requirements, and links to the scientific and technical specifications are presented. The pressure cell is able to accommodate a 200 mm 3 single crystal that can be pressurized up to 2 GPa at cryogenic temperatures. The pressure cell is consistent with the requirements of inelastic neutron scattering and, importantly, neutron polarization analysis. A particular strength of the uniaxial pressure cell is the highly uniform and low background for a wide scattering angle of 360° horizontally and ±20° vertically. We show the performance of the uniaxial pressure cell using a relevant neutron scattering instrument, the polarized diffuse scattering instrument, D7. The experiments confirm that the cell complies with the scientific and technical requirements. This uniaxial pressure cell will provide a useful additional tool in the sample environment suite available for the study of quantum magnetism.

47 OTHER INSTRUMENTATION↗