Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D Inspection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

H-Canyon exhaust tunnel LiDAR data request for information review and release

This request is to release LiDAR data files acquired by SRNL R&D Engineering and H-Area Operations and Engineering while performing scans of the interior of the H-Canyon Exhaust tunnel. LiDAR data includes 3-dimensional (3D) point cloud data sets and panoramic digital images of the interior tunnel wall surfaces. Presently two deployments have been completed, the first in November 2019, Fig. 1, and the second in June of 2020. This request is for the release of the data collected during those two deployments. Detailed information on the deployment and data collected can be found in SRS document C-ESR-H-00072, “November 2019 Initial Deployment of LiDAR”. It is planned to perform ongoing scans at approximately 6-month intervals, the purpose of the deployments is to evaluate the usefulness of the data collected to enable quantitative measurements such as tunnel dimensions and rate of surface erosion and as a precursor to a potential deployment of a LiDAR system on the tunnel inspection crawler.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microwave and Millimeter Wave Imaging of the Space Shuttle External Fuel Tank Spray on Foam Insulation (SOFI) Using Synthetic Aperture Focusing Techniques (SAFT)

The Space Shuttle Columbia's catastrophic failure is thought to have been caused by a dislodged piece of external tank SOFI (Spray On Foam Insulation) striking the left wing of the orbiter causing significant damage to some of the reinforced carbodcarbon leading edge wing panels. Microwave and millimeter wave nondestructive evaluation methods, have shown great potential for inspecting the SOFI for the purpose of detecting anomalies such as small voids that may cause separation of the foam from the external tank during the launch. These methods are capable of producing relatively high-resolution images of the interior of SOH particularly when advanced imaging algorithms are incorporated into the overall system. To this end, synthetic aperture focusing techniques are being deveioped for this purpose. These iechniqiies pradiice high-resolution images that are independent of the distance of the imaging probe to the SOFI with spatial resolution in the order of the half size of imaging probe aperture. At microwave and millimeter wave frequencies these apertures are inherently small resulting in high-resolution images. This paper provides the results of this investigation using 2D and 3D SAF based methods and holography. The attributes of these methods and a full discussion of the results will also be provided.

Case, J. T.↗

3D X-Ray Luggage-Screening System

A three-dimensional (3D) x-ray luggage- screening system has been proposed to reduce the fatigue experienced by human inspectors and increase their ability to detect weapons and other contraband. The system and variants thereof could supplant thousands of xray scanners now in use at hundreds of airports in the United States and other countries. The device would be applicable to any security checkpoint application where current two-dimensional scanners are in use. A conventional x-ray luggage scanner generates a single two-dimensional (2D) image that conveys no depth information. Therefore, a human inspector must scrutinize the image in an effort to understand ambiguous-appearing objects as they pass by at high speed on a conveyor belt. Such a high level of concentration can induce fatigue, causing the inspector to reduce concentration and vigilance. In addition, because of the lack of depth information, contraband objects could be made more difficult to detect by positioning them near other objects so as to create x-ray images that confuse inspectors. The proposed system would make it unnecessary for a human inspector to interpret 2D images, which show objects at different depths as superimposed. Instead, the system would take advantage of the natural human ability to infer 3D information from stereographic or stereoscopic images. The inspector would be able to perceive two objects at different depths, in a more nearly natural manner, as distinct 3D objects lying at different depths. Hence, the inspector could recognize objects with greater accuracy and less effort. The major components of the proposed system would be similar to those of x-ray luggage scanners now in use. As in a conventional x-ray scanner, there would be an x-ray source. Unlike in a conventional scanner, there would be two x-ray image sensors, denoted the left and right sensors, located at positions along the conveyor that are upstream and downstream, respectively (see figure). X-ray illumination may be provided by a single source or by two sources. The position of the conveyor would be detected to provide a means of matching the appropriate left- and right-eye images of an item under inspection. The appropriate right- and left-eye images of an item would be displayed simultaneously to the right and left eyes, respectively, of the human inspector, using commercially available stereo display screens. The human operator could adjust viewing parameters for maximum viewing comfort. The stereographic images thus generated would differ from true stereoscopic images by small distortions that are characteristic of radiographic images in general, but these distortions would not diminish the value of the images for identifying distinct objects at different depths.

Fernandez, Kenneth↗

Elemental characterization of LL-MA radioactive waste packages with the associated particle technique

The French Alternative Energies and Atomic Energy Commission (CEA) and National Radioactive Waste Management Agency (ANDRA) are conducting an R and D program to improve the characterization of long-lived and medium activity (LL-MA) radioactive waste packages with analytical methods and with non-destructive nuclear measurements. This paper concerns fast neutron interrogation with the associated particle technique (APT), which brings 3D information about the waste material composition. The characterization of volume elements filled with iron, water, aluminium, and PVC in bituminized and fibre concrete LL-MA waste packages has been investigated with MCNP [1] and MODAR data analysis software [2]. APT provides usable information about major elements presents in the volumes of interest. However, neutron scattering on hydrogen nuclei spreads the tagged neutron beam out of the targeted volume towards surrounding materials, reducing spatial selectivity. Simulation shows that small less than 1 L targets can be characterised up to the half-radius of a 225 L bituminized drum, the matrix of which is very rich in hydrogen. Deeper characterization in concrete is possible but limited by counting statistics due to photon attenuation in this dense matrix and, unless large inspection volumes are considered, by the lack of spatial selectivity of the tagged neutron beam due to neutron scattering. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overview of Additively Manufactured TPS Proposed Flight Test and Earth Re-Entry Capsule Design

A flight mechanics overview is presented of an Earth flight test designed to investigate a novel, 3D printed thermal protection system (TPS) that is currently in development at NASA as part of the Additive Manufacturing of Thermal Protection Systems project. The project is pioneering a method to print a thermal protection system onto an entry vehicle forebody one layer at a time. This method reduces labor and complexity as compared to traditional manufacturing methods while increasing mission-dependent customization of through-depth materials properties. The flight test has three objectives. First, subject the forebody stagnation point of a capsule equipped with additively manufactured TPS (AMTPS) material to peak heat fluxes in excess of 100 $W/cm^2$. Second, capture in-flight data to enable flight reconstruction and AMTPS material thermal response model improvement. Third, recover the capsule with data storage and forebody AMTPS intact to enable post-flight inspection and analysis of AMTPS performance. The flight test trajectory is designed to achieve a peak stagnation point, cold-wall, entry heat flux of 135~$W/cm^2$. Flight mechanics simulations are performed using the Program to Optimize Simulated Trajectories II (POST2) and Monte-Carlo analysis yields statistical percentiles on vehicle performance at key points along the trajectory. Based on the flight mechanics analysis presented in this paper, a prototype capsule was designed, partially fabricated, and underwent preliminary component stress testing in preparation for fabrication of the flight unit capsule. The capsule outer mold line is a modified version of the heritage Mars Microprobe geometry. The capsule has a 0.356~m diameter, a 30~kg mass, and a hypersonic ballistic coefficient of 300~$kg/m^2$. Sensor selection is guided by flight dynamics simulations with the goal of resolving the re-entry heating pulse. On-board instrumentation include forebody and aftbody pressure sensors and thermocouples, a 9-axis IMU, a GPS receiver, and an Iridium satellite modem, all of which collect and store data throughout flight via on-board avionics systems. A two-stage parachute system is designed to decelerate the capsule to touchdown velocities that will not result in significant fracture or deformation of the charred AMTPS material at ground impact.

Flight Mechanics↗

Automated detection and analysis of particle beams in laser-plasma accelerator simulations

Numerical simulations of laser-plasma wakefield (particle) accelerators model the acceleration of electrons trapped in plasma oscillations (wakes) left behind when an intense laser pulse propagates through the plasma. The goal of these simulations is to better understand the process involved in plasma wake generation and how electrons are trapped and accelerated by the wake. Understanding of such accelerators, and their development, offer high accelerating gradients, potentially reducing size and cost of new accelerators. One operating regime of interest is where a trapped subset of electrons loads the wake and forms an isolated group of accelerated particles with low spread in momentum and position, desirable characteristics for many applications. The electrons trapped in the wake may be accelerated to high energies, the plasma gradient in the wake reaching up to a gigaelectronvolt per centimeter. High-energy electron accelerators power intense X-ray radiation to terahertz sources, and are used in many applications including medical radiotherapy and imaging. To extract information from the simulation about the quality of the beam, a typical approach is to examine plots of the entire dataset, visually determining the adequate parameters necessary to select a subset of particles, which is then further analyzed. This procedure requires laborious examination of massive data sets over many time steps using several plots, a routine that is unfeasible for large data collections. Demand for automated analysis is growing along with the volume and size of simulations. Current 2D LWFA simulation datasets are typically between 1GB and 100GB in size, but simulations in 3D are of the order of TBs. The increase in the number of datasets and dataset sizes leads to a need for automatic routines to recognize particle patterns as particle bunches (beam of electrons) for subsequent analysis. Because of the growth in dataset size, the application of machine learning techniques for scientific data mining is increasingly considered. In plasma simulations, Bagherjeiran et al. presented a comprehensive report on applying graph-based techniques for orbit classification. They used the KAM classifier to label points and components in single and multiple orbits. Love et al. conducted an image space analysis of coherent structures in plasma simulations. They used a number of segmentation and region-growing techniques to isolate regions of interest in orbit plots. Both approaches analyzed particle accelerator data, targeting the system dynamics in terms of particle orbits. However, they did not address particle dynamics as a function of time or inspected the behavior of bunches of particles. Ruebel et al. addressed the visual analysis of massive laser wakefield acceleration (LWFA) simulation data using interactive procedures to query the data. Sophisticated visualization tools were provided to inspect the data manually. Ruebel et al. have integrated these tools to the visualization and analysis system VisIt, in addition to utilizing efficient data management based on HDF5, H5Part, and the index/query tool FastBit. In Ruebel et al. proposed automatic beam path analysis using a suite of methods to classify particles in simulation data and to analyze their temporal evolution. To enable researchers to accurately define particle beams, the method computes a set of measures based on the path of particles relative to the distance of the particles to a beam. To achieve good performance, this framework uses an analysis pipeline designed to quickly reduce the amount of data that needs to be considered in the actual path distance computation. As part of this process, region-growing methods are utilized to detect particle bunches at single time steps. Efficient data reduction is essential to enable automated analysis of large data sets as described in the next section, where data reduction methods are steered to the particular requirements of our clustering analysis. Previously, we have described the application of a set of algorithms to automate the data analysis and classification of particle beams in the LWFA simulation data, identifying locations with high density of high energy particles. These algorithms detected high density locations (nodes) in each time step, i.e. maximum points on the particle distribution for only one spatial variable. Each node was correlated to a node in previous or later time steps by linking these nodes according to a pruned minimum spanning tree (PMST). We call the PMST representation 'a lifetime diagram', which is a graphical tool to show temporal information of high dense groups of particles in the longitudinal direction for the time series. Electron bunch compactness was described by another step of the processing, designed to partition each time step, using fuzzy clustering, into a fixed number of clusters.

43 PARTICLE ACCELERATORS↗

High redshift LBGs from deep broadband imaging for future spectroscopic surveys

Lyman break galaxies (LBGs) are promising probes for clustering measurements at high redshift, z > 2, a region only covered so far by Lyman-α forest measurements. Here, in this paper, we investigate the feasibility of selecting LBGs by exploiting the existence of a strong deficit of flux shortward of the Lyman limit, due to various absorption processes along the line of sight. The target selection relies on deep imaging data from the HSC and CLAUDS surveys in the g, r, z and u bands, respectively, with median depths reaching 27 AB in all bands. The selections were validated by several dedicated spectroscopic observation campaigns with DESI. Visual inspection of spectra has enabled us to develop an automated spectroscopic typing and redshift estimation algorithm specific to LBGs. Based on these data and tools, we assess the efficiency and purity of target selections optimised for different purposes. Selections providing a wide redshift coverage retain 57% of the observed targets after spectroscopic confirmation with DESI, and provide an efficiency for LBGs of 83 ± 3%, for a purity of the selected LBG sample of 90 ± 2%. This would deliver a confirmed LBG density of ~ 620 deg$^{-2}$ in the range 2.3 < z < 3.5 for a r-band limiting magnitude r < 24.2. Selections optimised for high redshift efficiency retain 73% of the observed targets after spectroscopic confirmation, with 89 ± 4% efficiency for 97 ± 2% purity. This would provide a confirmed LBG density of ~ 470 deg$^{-2}$ in the range 2.8 < z < 3.5 for a r-band limiting magnitude r < 24.5.A preliminary study of the LBG sample 3d-clustering properties is also presented and used to estimate the LBG linear bias. A value of b$_{LBG}$ = 3.3 ± 0.2 (stat.) is obtained for a mean redshift of 2.9 and a limiting magnitude in r of 24.2, in agreement with results reported in the literature.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of Staggered Grid Finite Difference Schemes for Ultrasound Simulation in Curving Composites

The optimization of ultrasonic nondestructive evaluation (NDE) simulation tools for composites has the potential to reduce both individual part inspection time and overall certification time for composite parts and structures. Inspection guidance based on simulation provides increased confidence in the veracity of inspection results in addition to time reductions. This paper outlines ongoing work targeted to advance this objective through the use of finite difference (FD) simulation techniques formulated for composite structures with realistic geometries. Two staggered grid explicit FD schemes which show promise for this purpose are assessed: the Lebedev FD scheme and the rotated staggered grid (RSG) FD scheme. Algorithmic points which provide challenges for complex geometries are addressed, in particular handling of traction free surfaces and bi-material interfaces present at lamina boundaries. Code execution time estimates are performed as well to guide feasible domain sizes relative to algorithm choice and available hardware. Three test cases are simulated: a delaminated plate, a cylinder, and a triclinic lamina. These tests demonstrate that the Lebedev FD scheme needs additional work to handle inter-laminar interfaces and traction free boundaries in the presence of stair-stepping approximations. In contrast, the simple structure of the RSG unit cell makes it more straightforward to construct a 3D simulation technique for curved composite laminates.

Frankforter, Erik↗

Micro-CT scouting for transmission electron microscopy of human tissue specimens

Transmission electron microscopy (TEM) provides sub-nanometre-scale details in volumetric samples. Samples such as pathology tissue specimens are often stained with a metal element to enhance contrast, which makes them opaque to optical microscopes. As a result, it can be a lengthy procedure to find the region of interest inside a sample through sectioning. Here, we describe micro-CT scouting for TEM that allows noninvasive identification of regions of interest within a block sample to guide the sectioning step. In a tissue pathology study, a bench-top micro-CT scanner with 10 m resolution was used to determine the location of patches of the mucous membrane in osmium-stained human nasal scraping samples. Furthermore, once the regions of interest were located, the sample block was sectioned to expose that location, followed by ultra-thin sectioning and TEM to inspect the internal structure of the cilia of the membrane epithelial cells with nanometre resolution. This method substantially reduced the time and labour of the search process from typically 20 sections for light microscopy to three sections with no added sample preparation. Lay description Electron microscopy provides very high levels of detail in a small area, and thus the question of where to look in an opaque sample, such as a stained tissue specimen, needs to be answered by sectioning the sample in small steps and examining the sections under a light microscope, until the region of interest is found. The search process can be lengthy and labor intensive, especially for a study involving a large number of samples. Small areas of interest can be missed in the process if not enough regions are examined. We also describe a method to directly locate the region of interest within a whole sample using micro-CT imaging, bypassing the need of blindly sectioning. Micro-CT enables locating the region within 3D space; this information provides a guide for sectioning the sample to expose that precise location for high resolution electron microscopy imaging. In a human tissue specimen study, this method considerably reduced the time and labor of the search process.

60 APPLIED LIFE SCIENCES↗

The development of a population of 4D pediatric XCAT phantoms for imaging research and optimization

Purpose: We previously developed a set of highly detailed 4D reference pediatric extended cardiac-torso (XCAT) phantoms at ages of newborn, 1, 5, 10, and 15 yr with organ and tissue masses matched to ICRP Publication 89 values. In this work, we extended this reference set to a series of 64 pediatric phantoms of varying age and height and body mass percentiles representative of the public at large. The models will provide a library of pediatric phantoms for optimizing pediatric imaging protocols. Methods: High resolution positron emission tomography-computed tomography data obtained from the Duke University database were reviewed by a practicing experienced radiologist for anatomic regularity. The CT portion of the data was then segmented with manual and semiautomatic methods to form a target model defined using nonuniform rational B-spline surfaces. A multichannel large deformation diffeomorphic metric mapping algorithm was used to calculate the transform from the best age matching pediatric XCAT reference phantom to the patient target. The transform was used to complete the target, filling in the nonsegmented structures and defining models for the cardiac and respiratory motions. The complete phantoms, consisting of thousands of structures, were then manually inspected for anatomical accuracy. The mass for each major tissue was calculated and compared to linearly interpolated ICRP values for different ages. Results: Sixty four new pediatric phantoms were created in this manner. Each model contains the same level of detail as the original XCAT reference phantoms and also includes parameterized models for the cardiac and respiratory motions. For the phantoms that were 10 yr old and younger, we included both sets of reproductive organs. This gave them the capability to simulate both male and female anatomy. With this, the population can be expanded to 92. Wide anatomical variation was clearly seen amongst the phantom models, both in organ shape and size, even for models of the same age and sex. The phantoms can be combined with existing simulation packages to generate realistic pediatric imaging data from different modalities. Conclusions: This work provides a large cohort of highly detailed pediatric phantoms with 4D capabilities of varying age, height, and body mass. The population of phantoms will provide a vital tool with which to optimize 3D and 4D pediatric imaging devices and techniques in terms of image quality and radiation-absorbed dose.

60 APPLIED LIFE SCIENCES↗

Gamma-ray tracking for high energy gamma-ray imaging in pixelated CdZnTe

Sequencing gamma-ray interactions within a detector system is an integral component of Compton imaging. In detectors with poor timing resolution compared to the time interval of successive interactions, algorithms which order gamma-ray interactions must be implemented using only energy and position information. This work examines previous algorithms and inspects interaction kinematics to increase the sequencing algorithm’s speed and effectiveness. The proposed method, in which the first interaction is assumed to deposit the largest energy, has improved sequencing performance by greater than 20% for full energy gamma ray depositions larger than 1 MeV that do not contain pair-production. In addition, the algorithm shows a decrease in computational costs for sequence reconstruction to allow for better real time reconstruction. Experimental results show an almost twofold increase in the signal to noise ratio (SNR) for simple backprojection images of a 22 Na source. Additional measurements of the 2.2 MeV gamma rays from H 1 (n,$\gamma$)D 2 neutron capture demonstrates the proposed algorithm’s superior performance.

3D position sensitive CdZnTe↗

SeeSnake: Radiological Characterisation of Complex Nuclear Spaces - 16162

Decommissioning of retired nuclear plant can be a difficult task for many reasons. A number of locations around the world have active cells awaiting decommissioning without a clear understanding of the internal structure and possible locations of radiological sources. Furthermore, many nuclear plant drawings and models do not reflect the 'as built' dimensions, and precise data required for safe and cost effective decommissioning is not readily available. This presents decommissioning teams with significant challenges when attempting to plan and execute their decommissioning programs. Due to the complex nature and constrained environments typical of legacy nuclear plant, it is often not possible to deploy traditional remote handling/inspection technologies. Even where possible, identifying the correct sensor, or suite of sensors, to characterize the environment is problematic. To address this common issue Create Technologies Ltd (Createc) and OC Robotics collaborated on SeeSnake, a project aimed at leveraging radiometric source mapping with 3D scanning and confined space remote handling. Createc's imaging and sensing systems have strong capabilities in the nuclear industry, led by their N-Visage products, as do OC Robotics' snake-arm robots as a remote deployment platform for confined and hazardous spaces. The snake-arm robot enables access through small penetrations with the ability to navigate internal structures and other obstacles without support from the environment; whilst multiple re-positioning of the N-Visage sensor, integrated with the snake-arm system, enables a thorough 3D map to be created. The SeeSnake project demonstrates the integrated systems ability to capture valuable radiation, visual and positional data enabling the characterization of a complex active environment. To mature the concept into an integrated, functional technology the SeeSnake partners overcame a number of challenges before demonstrating to key stakeholders in the UK nuclear industry. This paper describes these challenges and the solutions implemented, along with the results from early system trials and stakeholder demonstrations. It also addresses the next steps for the SeeSnake technology and identifies a number of applications which will may benefit from its exploitation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interpenetrating metal-organic frameworks formed by self-assembly of tetrahedral and octahedral building blocks

To investigate the relationship between topological types and molecular building blocks (MBBs), we have designed and synthesized a series of three-dimensional (3D) interpenetrating metal-organic frameworks based on different polygons or polyhedra under hydrothermal conditions, namely [Cd(bpib){sub 0.5}(L{sup 1})] (1), [Cd(bpib){sub 0.5}(L{sup 2})].H{sub 2}O (2), [Cd(bpib){sub 0.5}(L{sup 3})] (3) and [Cd(bib){sub 0.5}(L{sup 1})] (4), where bpib=1,4-bis(2-(pyridin-2-yl)-1H-imidazol-1-yl)butane, bib=1,4-bis(1H-imidazol-1-yl)butane, H{sub 2}L{sup 1}=4-(4-carboxybenzyloxy)benzoic acid, H{sub 2}L{sup 2}=4,4'-(ethane-1,2-diylbis(oxy))dibenzoic acid and H{sub 2}L{sup 3}=4,4'-(1,4-phenylenebis(methylene))bis(oxy)dibenzoic acid, respectively. Their structures have been determined by single crystal X-ray diffraction analyses and further characterized by elemental analyses, IR spectra, and thermogravimetric (TG) analyses. Compounds 1-3 display alpha-Po topological nets with different degrees of interpenetration based on the similar octahedral [Cd{sub 2}(-COO){sub 4}] building blocks. Compound 4 is a six-fold interpenetrating diamondoid net based on tetrahedral MBBs. By careful inspection of these structures, we find that various carboxylic ligands and N-donor ligands with different coordination modes and conformations, and metal centers with different geometries are important for the formation of the different MBBs. It is believed that different topological types lie on different MBBs with various polygons or polyhedra. Such as four- and six-connected topologies are formed by tetrahedral and octahedral building blocks. In addition, with the increase of carboxylic ligands' length, the degrees of interpenetration have been changed in the alpha-Po topological nets. And the luminescent properties of these compounds have been investigated in detail. - Graphical abstract: A series of three-dimensional interpenetrating metal-organic frameworks based on different polygons or polyhedra has been synthesized. The crystal structures and topological analysis of these compounds, along with a systematic investigation of the relationship between topological types and molecular building blocks, will be discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Feasibility Study of Millimeter Wave Radars For Safeguards Applications

Containment and surveillance are fundamental measures in nuclear safeguards. Techniques such as video surveillance and laser curtain for containment provide effective monitoring in areas where maintaining continuity of knowledge is required. These systems, however, can be susceptible to loss of monitoring capabilities under certain environmental conditions such as poor visibility (i.e. low light conditions, smoke, fog, etc.) or extended power loss past the duration that the backup power system is designed for. Brookhaven National Laboratory has been investigating the feasibility of millimeter waves (mmWave) as a new perimeter seal in which radio frequency waves in the range of 60-64 GHz are used to detect and monitor objects of interest. Signals in this frequency range are not susceptible to environmental conditions. For proof-of-concept tests, mmWave sensors from Texas Instruments (TI), specificallyIWR6843, are used in a test bed at BNL's Waste Management facility to simulate the operations at nuclear facilities. The unique design of TI mmWave sensors requires less memory and power consumption compared to counterpart systems. These devices are capable of exporting 3D point-cloud data, which is visualized graphically and compared to videos recorded at the same time to validate the performance of the mmWave sensor. A set of experiments were planned to test the feasibility of the mmWave in this application, including monitoring static containers in a storage area and detecting intrusions at the boundaries of the area. In addition, the experiments also identify potential blind spots relative to sensor position and utilize multiple operating sensors simultaneously to reduce or eliminate such blind spots. The optimal positioning of multiple sensors was determined for the experimental room configuration. In this paper, we will discuss the details of this novel perimeter sealing concept and present the test results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Data acquisition and analysis of the UNCOSS underwater explosive neutron sensor

The purpose of the FP7 UNCOSS project (Underwater Coastal Sea Surveyor, http://www.uncoss-project.org) is to develop a neutron-based underwater explosive sensor to detect unexploded ordnance lying on the sea bottom. The Associated Particle Technique is used to focus the inspection on a suspicious object located by optical and electromagnetic sensors and to determine if there is an explosive charge inside. This paper presents the data acquisition electronics and data analysis software which have been developed for this project. The electronics digitize and process the signal in real-time based on a field programmable gate array structure to perform precise time-of-flight and gamma-ray energy measurements. UNCOSS software offers the basic tools to analyze the time-of-flight and energy spectra of the interrogated object. It allows to unfold the gamma-ray spectrum into pure elemental count proportions, mainly C, N, O, Fe, Al, Si, and Ca. The C, N, and O count fractions are converted into chemical proportions by taking into account the gamma-ray production cross sections, as well as neutron and photon attenuation in the different shields between the ROV (Remotely Operated Vehicle) and the explosive, such as the explosive iron shell, seawater, and ROV envelop. These chemical ratios are plotted in a two-dimensional (2D) barycentric representation to position the measured point with respect to common explosives. The systematic uncertainty due to the above attenuation effects and counting statistical fluctuations are combined with a Monte Carlo method to provide a 3D uncertainty area in a barycentric plot, which allows to determine the most probable detected materials in view to make a decision about the presence of explosive. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oblique reconstructions in tomosynthesis. II. Super-resolution

Purpose: In tomosynthesis, super-resolution has been demonstrated using reconstruction planes parallel to the detector. Super-resolution allows for subpixel resolution relative to the detector. The purpose of this work is to develop an analytical model that generalizes super-resolution to oblique reconstruction planes.Methods: In a digital tomosynthesis system, a sinusoidal test object is modeled along oblique angles (i.e., “pitches”) relative to the plane of the detector in a 3D divergent-beam acquisition geometry. To investigate the potential for super-resolution, the input frequency is specified to be greater than the alias frequency of the detector. Reconstructions are evaluated in an oblique plane along the extent of the object using simple backprojection (SBP) and filtered backprojection (FBP). By comparing the amplitude of the reconstruction against the attenuation coefficient of the object at various frequencies, the modulation transfer function (MTF) is calculated to determine whether modulation is within detectable limits for super-resolution. For experimental validation of super-resolution, a goniometry stand was used to orient a bar pattern phantom along various pitches relative to the breast support in a commercial digital breast tomosynthesis system.Results: Using theoretical modeling, it is shown that a single projection image cannot resolve a sine input whose frequency exceeds the detector alias frequency. The high frequency input is correctly visualized in SBP or FBP reconstruction using a slice along the pitch of the object. The Fourier transform of this reconstructed slice is maximized at the input frequency as proof that the object is resolved. Consistent with the theoretical results, experimental images of a bar pattern phantom showed super-resolution in oblique reconstructions. At various pitches, the highest frequency with detectable modulation was determined by visual inspection of the bar patterns. The dependency of the highest detectable frequency on pitch followed the same trend as the analytical model. It was demonstrated that super-resolution is not achievable if the pitch of the object approaches 90°, corresponding to the case in which the test frequency is perpendicular to the breast support. Only low frequency objects are detectable at pitches close to 90°.Conclusions: This work provides a platform for investigating super-resolution in oblique reconstructions for tomosynthesis. In breast imaging, this study should have applications in visualizing microcalcifications and other subtle signs of cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

R and DE Robotic Sensor Intern Team: Sensor Suite Software and User Interface

The sensor tree developed for the H-Canyon tunnel inspection project produces a large quantity of camera and Lidar data. A postprocessing pipeline was created to facilitate the analysis of these data. The pipeline follows the following routine: 1) Registration - Salient local features in subsequent scans are identified and used to align the scans with one another. This allows production of a single cohesive map of the tunnel. 2) Sensor Fusion - RGB camera data is 'painted' onto the depth data created by the Lidar. 3) Segmentation - Individual surfaces from within the scene are segmented out separately for individual analysis. 4) Degradation Analysis - Automatic mapping of local deviation from the plane in position or surface normal is performed, as is detection of exposed rebar using Lidar return intensity. 5) Obstacle Detection - Lidar data is also used in real time to detect obstacles in the environment. This could give feedback to the operator to successfully drive in the tunnel. 6) Graphic User Interface - a custom GUI was created to facilitate customer use of the system. The system provides real-time feedback from both the cameras and Lidar. During alignment, local features are used to recognize points within the walls that are especially unique and noticeable (salient) based on their deviation from the expected surface of the wall. These are used as landmarks to register the clouds, which also informs precise localization of the base at each scan point. After registration, clouds are 'painted' with RGB data from the spherical cameras, as shown below. The painted clouds provide a 3D, colorized model of the environment which improves the realism of the experience for the user. Painting also labels high-resolution color imagery from the 3D cameras with depth values. Following sensor fusion, individual walls and cylindrical duct surfaces are segmented from the scene for individual analysis using a Random Sample Consensus algorithm. This algorithm allows segmentation of planar walls and cylindrical ducts. Once individual walls are identified, each point within the wall can be compared to its neighbors and the wall overall in order to detect local areas with damaged concrete. Automatic rebar detection is also performed using the contrast in Lidar return intensity between iron and concrete. The Lidar point-cloud data is also used for obstacle detection. As the Lidar spins, various algorithms are run to analyze the current 'slice' and obstacles in the environment are determined and registered on a cost-map. A Graphical User Interface (GUI) was developed to allow the user to easily command the crawler to set the rotational speed of the Lidar, perform a scan, and register and save the 3D generated cloud after a scan is done. For the good of the crawler, a critical aspect of the GUI design is to allow the user to cancel a scan any time after it is commanded and before it is saved.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automatic multiscale enhancement and segmentation of pulmonary vessels in CT pulmonary angiography images for CAD applications

The authors are developing a computerized pulmonary vessel segmentation method for a computer-aided pulmonary embolism (PE) detection system on computed tomographic pulmonary angiography (CTPA) images. Because PE only occurs inside pulmonary arteries, an automatic and accurate segmentation of the pulmonary vessels in 3D CTPA images is an essential step for the PE CAD system. To segment the pulmonary vessels within the lung, the lung regions are first extracted using expectation-maximization (EM) analysis and morphological operations. The authors developed a 3D multiscale filtering technique to enhance the pulmonary vascular structures based on the analysis of eigenvalues of the Hessian matrix at multiple scales. A new response function of the filter was designed to enhance all vascular structures including the vessel bifurcations and suppress nonvessel structures such as the lymphoid tissues surrounding the vessels. An EM estimation is then used to segment the vascular structures by extracting the high response voxels at each scale. The vessel tree is finally reconstructed by integrating the segmented vessels at all scales based on a 'connected component' analysis. Two CTPA cases containing PEs were used to evaluate the performance of the system. One of these two cases also contained pleural effusion disease. Two experienced thoracic radiologists provided the gold standard of pulmonary vessels including both arteries and veins by manually tracking the arterial tree and marking the center of the vessels using a computer graphical user interface. The accuracy of vessel tree segmentation was evaluated by the percentage of the 'gold standard' vessel center points overlapping with the segmented vessels. The results show that 96.2% (2398/2494) and 96.3% (1910/1984) of the manually marked center points in the arteries overlapped with segmented vessels for the case without and with other lung diseases. For the manually marked center points in all vessels including arteries and veins, the segmentation accuracy are 97.0% (4546/4689) and 93.8% (4439/4732) for the cases without and with other lung diseases, respectively. Because of the lack of ground truth for the vessels, in addition to quantitative evaluation of the vessel segmentation performance, visual inspection was conducted to evaluate the segmentation. The results demonstrate that vessel segmentation using our method can extract the pulmonary vessels accurately and is not degraded by PE occlusion to the vessels in these test cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗