Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3-He detector electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Detector and Physics Performance at a Muon Collider

A muon collider represents the ideal machine to reach very high center-of-mass energies and luminosities by colliding elementary particles. This is the result of the low level of beamstrahlung and synchrotron radiation compared to linear or circular electron-positron colliders. In contrast with other lepton machines, the design of a detector for a multi-TeV muon collider requires detailed knowledge of the interaction region due to the significant backgrounds created by muon beam decays in the collider ring. The physics reach can be properly evaluated only when the detector performance in such an environment is determined. In this work, the backgrounds generated by muon beams of 750 GeV are characterized and the performance of the tracking system and the calorimeter detector is illustrated. Solutions to minimize the effect of the beam-induced backgrounds are discussed and applied to obtain track and jet reconstruction performance. The μ + μ – → $Hν\bar{ν} → b\bar{b} ν\bar{ν}$ process is fully simulated and reconstructed to demonstrate that physics measurements are possible in this harsh environment. The measurement precision for the Higgs boson coupling to $b\bar{b}$ is evaluated for $\sqrt{s}$=1.5, 3, and 10 TeV and compared to other proposed machines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterizing dark matter signals with missing momentum experiments

Fixed target missing-momentum experiments such as LDMX and M 3 are powerful probes of light dark matter and other light, weakly coupled particles beyond the Standard Model (SM). Such experiments involve ~10 GeV beam particles whose energy and momentum are individually measured before and after passing through a suitably thin target. If new states are radiatively produced in the target, the recoiling beam particle loses a large fraction of its initial momentum, and no SM particles are observed in a downstream veto detector. We explore how such experiments can use kinematic variables and experimental parameters, such as beam energy and polarization, to measure properties of the radiated particles and discriminate between models if a signal is discovered. In particular, the transverse momentum of recoiling particles is shown to be a powerful tool to measure the masses of new radiated states, offering significantly better discriminating ability compared to the recoil energy alone. We further illustrate how variations in beam energy, polarization, and lepton flavor (i.e., electron or muon) can be used to disentangle the possible the Lorentz structure of the new interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search for dark matter production in association with bottom quarks and a lepton pair in proton-proton collisions at $\sqrt{s}=13$ TeV

A search is performed for dark matter produced in association with bottom quarks and a pair of electrons or muons in data collected with the CMS detector at the LHC, corresponding to 138 fb −1 of integrated luminosity of proton-proton collisions at a center-of-mass energy of 13 TeV. For the first time at the LHC, the associated production of a bottom quark-antiquark pair and a new heavy neutral Higgs boson (H) that subsequently decays into a leptonically decaying Z boson and a pseudoscalar (a) is explored. The latter acts as a dark matter mediator in the context of the two Higgs doublet model plus a pseudoscalar (2HDM+a). Multivariate techniques that target a wide range of mass configurations for the H and a particles are used. The observations are consistent with the expectations from standard model processes. Upper limits at 95% confidence level are set on the product of cross section and branching fraction of the new particles, ranging from 10 −2 pb for an H mass of 400 GeV to 10 −3 pb for an H mass of 2000 GeV. Constraints on the parameter space of a benchmark 2HDM+a model are derived and compared with expectations in the context of cosmological predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identifying Spectral Descriptors for Protonation in BaZr 0.8 Y 0.2 O 3-x with Electron Energy Loss Spectroscopy

Hydrogen economy is of paramount importance in the global transition to a sustainable, clean energy source that contributes to decarbonization efforts. In particular, the proton conducting proton ceramic fuel cells (PCFCs) play a crucial role in promoting hydrogen energy technology [1-5]. In a PCFC, the electrolyte is typically a solid oxide material that enables proton transport and can operate at temperatures lower than those of traditional oxygen ion conducting fuel cells [6]. The reduced operating temperature of PCFCs contributes to their durability, scalability, and efficiency [7,8]. BaZr 0.8 Y 0.2 O 3-x (BZY) is a promising proton conducting solid oxide electrolyte [9,10]. The emphasis on proton conductivity entails the importance of understanding proton content in the system. However, previous studies have largely relied on bulk techniques such as electrochemical impedance spectroscopy [7,11], Karl-Fischer titration [12,13], and thermogravimetric analysis [14] to obtain proton concentration. This is due to the small atomic size and light mass of hydrogen species making direct detection challenging. Bulk methods may be useful in estimating the proton content; however, it overlooks possible proton concentration gradient or segregation that may occur across or within a nanoparticle, especially when proton incorporation occurs nonuniformly through steam exposure on powder samples. In this paper, BZY is protonated at an estimated 0.15 mol of protons via steam exposure. Electron energy loss spectroscopy (EELS) with nanoscale spatial resolution is explored to identify proxy signals for proton detection using a JEOL ARM300 microscope operated at 300 kV with a Gatan GIF Continuum detector.

08 HYDROGEN↗

RD53A: A large-scale prototype chip for the phase II upgrade in the serially powered HL-LHC pixel detectors

The phase II upgrade of the HL-LHC experiments within the LHC intends to deepen the studies of the Higgs boson and to allow the discovery of further particles by adding an integrated luminosity of about 4000 fb -1 over 10 years of operation. This upgrade would overwhelm the installed pixel detector readout chips with higher hit rates and radiation levels than ever before. To match these extreme requirements the RD53 collaboration, a joint effort between ATLAS and CMS, developed RD53A, a new generation pixel detector readout chip prototype manufactured in a 65 nm CMOS technology. It is half the size of the final pixel chips and designed to meet requirements in the face of 3 GHz/cm 2 hit rate after irradiation to 500 Mrad. The detector is able to use 50×50 μm 2 or 25×100 μm 2 pixels with high readout speed of up to 4 links per chip with 1.28 Gbit/s each. Shunt–LDO regulators integrated on the bottom of the chip provide the required voltages to the two power domains, analog and digital. These regulators enable serial powering of the pixel modules, which is the only feasible, radiation hard scheme to ensure acceptable power cable losses and to stay within the material budget for the future pixel detectors. Finally, an overview of the status and challenges of serial powering and the Shunt–LDO regulator development will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic-quenching of a single-photon avalanche photodetector using an adaptive resistive switch

One of the most common approaches for quenching single-photon avalanche diodes is to use a passive resistor in series with it. A drawback of this approach has been the limited recovery speed of the single-photon avalanche diodes. High resistance is needed to quench the avalanche, leading to slower recharging of the single-photon avalanche diodes depletion capacitor. We address this issue by replacing a fixed quenching resistor with a bias-dependent adaptive resistive switch. Reversible generation of metallic conduction enables switching between low and high resistance states under unipolar bias. As an example, using a Pt/Al 2 O 3 /Ag resistor with a commercial silicon single-photon avalanche diodes, we demonstrate avalanche pulse widths as small as ~30 ns, 10× smaller than a passively quenched approach, thus significantly improving the single-photon avalanche diodes frequency response. The experimental results are consistent with a model where the adaptive resistor dynamically changes its resistance during discharging and recharging the single-photon avalanche diodes.

42 ENGINEERING↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The exit-wave power-cepstrum transform for scanning nanobeam electron diffraction: robust strain mapping at subnanometer resolution and subpicometer precision

Scanning nanobeam electron diffraction (NBED) with fast pixelated detectors is a valuable technique for rapid, spatially resolved mapping of lattice structure over a wide range of length scales. However, intensity variations caused by dynamical diffraction and sample mistilts can hinder the measurement of diffracted disk centers as necessary for quantification. Robust data processing techniques are needed to provide accurate and precise measurements for complex samples and non-ideal conditions. Here we present an approach to address these challenges using a transform, called the exit wave power cepstrum (EWPC), inspired by cepstral analysis in audio signal processing. The EWPC transforms NBED patterns into real-space patterns with sharp peaks corresponding to inter-atomic spacings. We describe a simple analytical model for interpretation of these patterns that cleanly decouples lattice information from the intensity variations in NBED patterns caused by tilt and thickness. With tracking the inter-atomic spacing peaks in EWPC patterns, strain mapping is demonstrated for two practical applications: mapping of ferroelectric domains in epitaxially strained PbTiO 3 films and mapping of strain profiles in arbitrarily oriented core-shell Pt-Co nanoparticle fuel-cell catalysts. The EWPC transform enables lattice structure measurement at sub-pm precision and sub-nm resolution that is robust to small sample mistilts and random orientations.

42 ENGINEERING↗

Solution epitaxy of polarization-gradient ferroelectric oxide films with colossal photovoltaic current

Solution growth of single-crystal ferroelectric oxide films has long been pursued for the low-cost development of high-performance electronic and optoelectronic devices. However, the established principles of vapor-phase epitaxy cannot be directly applied to solution epitaxy, as the interactions between the substrates and the grown materials in solution are quite different. Here, we report the successful epitaxy of single-domain ferroelectric oxide films on Nb-doped SrTiO 3 single-crystal substrates by solution reaction at a low temperature of ~200 o C. The epitaxy is mainly driven by an electronic polarization screening effect at the interface between the substrates and the as-grown ferroelectric oxide films, which is realized by the electrons from the doped substrates. Atomic-level characterization reveals a nontrivial polarization gradient throughout the films in a long range up to ~500 nm because of a possible structural transition from the monoclinic phase to the tetragonal phase. This polarization gradient generates an extremely high photovoltaic short-circuit current density of ~2.153 mA/cm 2 and open-circuit voltage of ~1.15 V under 375 nm light illumination with power intensity of 500 mW/cm 2 , corresponding to the highest photoresponsivity of ~4.306×10 -3 A/W among all known ferroelectrics. Our results establish a general low-temperature solution route to produce single-crystal gradient films of ferroelectric oxides and thus open the avenue for their broad applications in self-powered photo-detectors, photovoltaic and optoelectronic devices.

36 MATERIALS SCIENCE↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation studies related to the particle identification by the forward and backward RICH detectors at Electron Ion Collider

The Electron-Ion collider (EIC) will be the ultimate facility to study the dynamics played by colored quarks and gluons in the phenomenology of nucleons and nuclei, described by Quantum Chromodynamics. The physics programs will greatly rely on efficient particle identification (PID) in both the forward and the backward regions. The forward and the backward RICHes of the EIC have to be able to cover wide acceptance and momentum ranges; in the forward region a dual radiator RICH (dRICH) is foreseen and in the backward region a proximity-focusing RICH can be foreseen to be employed. The geometry and the performance studies of the dRICH have been performed as prescribed in the EIC Yellow Report using the ATHENA software framework. Furthermore, this part of our work reports the effort following the call for EIC detector proposal and the studies related to the forward and the backward RICH performance. In the forward region, the dRICH performance showed a pion- kaon separation from around 1 GeV/c to 50 GeV/c at a three sigma level; the proximity focusing RICH (pfRICH) foreseen for the backward region can reach three sigma separation up to 3 GeV/c for e/$π$ and up to 10 GeV/c for $π$/K mass hypotheses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-energy calibration of a PILATUS3 CdTe detector for hard x-ray measurements of magnetically confined fusion plasmas

A multi-energy hard x-ray pin-hole camera based on the PILATUS3 X 100K-M CdTe detector has been developed at the Princeton Plasma Physics Laboratory for installation on the Tungsten Environment in Steady State Tokamak. This camera will be employed to study thermal plasma features such as electron temperature as well as non-thermal effects such as fast electron tails produced by a lower hybrid radiofrequency current drive and the birth of runaway electrons. The innovative aspect of the system lies in the possibility of setting the threshold energy independently for each of the ~100k pixels of the detector. This feature allows for the measurement of the x-ray emission in multiple energy ranges with adequate space and time resolution (~1 cm, 2 ms) and coarse energy resolution. In this work, the energy dependence of each pixel was calibrated within the range 15 keV–100 keV using a tungsten x-ray tube and emission from a variety of fluorescence targets (from yttrium to uranium). The data corresponding to pairs of K α emission lines are fit to the characteristic responsivity (“S-curve”), which describes the detector sensitivity across the 64 possible energy threshold values for each pixel; this novel capability is explored by fine-tuning the voltage of a six-bit digital-analog converter after the charge-sensitive amplifier for each of the ~100k pixels. Here, this work presents the results of the calibration including a statistical analysis. It was found that the achievable energy resolution is mainly limited by the width of the S-curve to 3 keV–10 keV for threshold energies up to 50 keV, and to ≥20 keV for energies above 60 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The AMACStar ASIC for the HL-LHC ATLAS ITk Strip detector: design, verification, testing, and quality assurance

For the high-luminosity upgrade to the LHC (HL-LHC), the ATLAS detector at CERN requires an all-new inner detector, the Inner Tracker (ITk). The ITk Strip subdetector is made up of silicon modules, which include three types of radiation-hard ASICs. One of these is the Autonomous Monitor and Control (AMAC). The AMAC is manufactured by Global Foundries using 130 nm CMOS8RF DM technology and is approximately 3 by 5 mm in size. This ASIC autonomously monitors the temperatures, voltages, and currents in the module components while controlling critical values in order to prevent these quantities from reaching dangerous levels. The final design, AMACStar, was verified, tested, and ensured to perform all necessary functions. A quality control procedure using an in-house probe station set-up was developed in order to ensure that every individual chip on each wafer of AMACStars required by the ITk Strip project met performance requirements. The average per wafer yield of usable AMACStars is 92.33%, exceeding the design-specific 90% yield estimated for project costing. This estimate was based on actual yields for similar designs in this process.

Analogue electronic circuits↗

On optical properties and scintillation performance of emerging Ga 2 O 3 : Crystal growth, emission mechanisms and doping strategies

As an emerging ultra-wide bandgap compound semiconductor, Ga 2 O 3 has attracted rapidly growing interest due to its unique physical properties for harsh condition applications. Compared to Ga 2 O 3 ’s electrical-characteristic based uses, such as power electronics, photodetectors and solar cells, a much less explored area for Ga 2 O 3 is its promising optical properties and its related scintillation capabilities. Undoped Ga 2 O 3 is a strong scintillator with excellent scintillation characteristics such as fast decay constants and encouraging light yield which is comparable to that of the classic Bi 4 Ge 3 O 12 (BGO) scintillator. The scintillation capability of Ga 2 O 3 can be precisely tuned via a series of approaches including systematic crystal growth control, post-growth annealing, targeted doping, and optimization of operation temperature. Here we summarize exciting progress of Ga 2 O 3 scintillators which have been pursued over the past few years. Our efforts cover a series of growth techniques of Ga 2 O 3 materials as well as discussion of emission mechanisms. Here we dedicate a targeted portion toward the doping strategies to improve the performance of Ga 2 O 3 . A detailed analysis is provided to compare the impact of different dopants. Through these efforts, we hope to provide useful perspectives to help accelerate the development of high performance Ga 2 O 3 scintillators.

36 MATERIALS SCIENCE↗

Performance of Scintillation Detectors Based on Quantum Dots in a Semiconductor Matrix (Final Technical Report)

InAs Quantum Dots (QDs) embedded into GaAs semiconductor waveguide have unique scintillation properties, valuable for nuclear security, medical imaging, and high energy physics. In this work, we developed thick (~25um) epitaxial heterostructres with high luminescence efficiency composed of self-assembled nano-engineered InAs QDs grown by molecular beam epitaxy. In this type of detector, the GaAs matrix acts as a stopping material for charged particles or photons generating electrons captured by the QDs acting as luminescence centers. The QD medium is designed to provide fast capture of electrons into QDs (few ps), high QD luminescence efficiency at room temperature (>50%), and strong red-shift of photoluminescence (PL) from the GaAs absorption edge (>250nm). Typical devices consist of a 10-25um thick GaAs layer with embedded sheets of modulation p-type doped InAs QDs and an InGaAs photodetector tuned to the QD emission wavelength. The thick GaAs layer acts also as a waveguide when layer-transferred onto a low-index substrate. Waveguiding and self-absorption (~1cm -1 ) were studied using photoluminescence with scanning laser excitation and modeled with ray optics approximation and geometrical coupling of high-index waveguide to a collection fiber. Scintillating signals from α-particles were analyzed with both an external photodiode (PD) and an integrated PD which provided an improved optical coupling. In the former case, the external InGaAs PD was air-coupled to the scintillator and had the light collection efficiency of about 1% corresponding to limited light extraction through a planar interface with air due to total internal reflection. The mean charge collected by the integrated PD was in the range of (3÷5)×10 4 photoelectrons per 1 MeV of deposited energy, or ~13-20% of the theoretically achievable light yield. Timing of the integrated device was measured by wire-bonding it to the input of an 8 GHz IC. The scintillation response shows an extremely fast 0.3-0.6 ns decay constant and about 40-70 ps time resolution, limited by the system noise. The combined light yield and decay time makes the InAs/GaAs QD heterostructures the fastest high yield scintillation material reported making it valuable for high energy physics and medical imaging applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗