Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “0000”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Spin transition in Gd{sub 3}N-C{sub 80}, detected by low-temperature on-chip SQUID technique

We present a magnetic study of the Gd{sub 3}N-C{sub 80} molecule, consisting of a Gd-trimer via a nitrogen atom, encapsulated in a C{sub 80} cage. This molecular system can be an efficient contrast agent for magnetic resonance imaging (MRI) applications. We used a low-temperature technique able to detect small magnetic signals by placing the sample in the vicinity of an on-chip SQUID. The technique implemented at the National High Magnetic Field Laboratory has the particularity of being able to operate in high magnetic fields of up to 7 T. The Gd{sub 3}N-C{sub 80} shows a paramagnetic behavior and we find a spin transition of the Gd{sub 3}N structure at 1.2 K. We perform quantum mechanical simulations, which indicate that one of the Gd ions changes from a {sup 8}S{sub 7/2} state (L = 0, S = 7/2) to a {sup 7}F{sub 6} state (L = S = 3, J = 6), likely due to a charge transfer between the C{sub 80} cage and the ion.

36 MATERIALS SCIENCE↗

Time-dependent manipulation of ultracold ion bunches

The combination of an ultracold ion source based on photoionization of a laser-cooled gas and time-dependent acceleration fields enables precise manipulation of ion beams. We demonstrate reduction in the longitudinal energy spread and transverse (de)focusing of the beam by applying time-dependent acceleration voltages. In addition, we show how time-dependent acceleration fields can be used to control both the sign and strength of the spherical aberrations. The experimental results are in close agreement with detailed charged particle tracking simulations and can be explained in terms of a simple analytical model.

43 PARTICLE ACCELERATORS↗

Magnetocaloric effect in Tb{sub 60}Ni{sub 30}Al{sub 10} glass: A material that can either heat or cool upon magnetization

The Tb{sub 60}Ni{sub 30}Al{sub 10} amorphous alloy was prepared by melt-spinning in the form of ribbons. Its magnetic behavior shows upon magnetization the occurrence of a spin glass to ferromagnetic and a paramagnetic to ferromagnetic transitions at 5 and 48 K. The magnetocaloric effects associated with these transitions were investigated. Large positive and negative magnetic entropy changes upon magnetization have been observed in a temperature range interesting for gas liquefaction.

36 MATERIALS SCIENCE↗

Electron density and temperature of gas-temperature-dependent cryoplasma jet

A microsize cryoplasma jet was developed and analyzed at plasma gas temperatures ranging from room temperature down to 5 K. Experimental results obtained from optical emission spectroscopy and current-voltage measurements indicate that the average electron density and electron temperature of the cryoplasma jet depend on the gas temperature. In particular, the electron temperature in the cryoplasma starts to decrease rapidly near 60 K from about 13 eV at 60 K to 2 eV at 5 K, while the electron density increases from about 10{sup 9} to approximately 10{sup 12} cm{sup -3} from room temperature to 5 K. This phenomenon induces an increase in the Coulomb interaction between electrons, which can be explained by the virial equation of state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A superconducting quantum interference device based read-out of a subattonewton force sensor operating at millikelvin temperatures

We present a scheme to measure the displacement of a nanomechanical resonator at cryogenic temperature. The technique is based on the use of a superconducting quantum interference device to detect the magnetic flux change induced by a magnetized particle attached on the end of the resonator. Unlike conventional interferometric techniques, our detection scheme does not involve direct power dissipation in the resonator, and therefore, is particularly suitable for ultralow temperature applications. We demonstrate its potential by cooling an ultrasoft silicon cantilever to a noise temperature of 25 mK, corresponding to a subattonewton thermal force noise of 0.5 aN/{radical}(Hz).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Green luminescence of InGaN nanowires grown on silicon substrates by molecular beam epitaxy

Indium gallium nitride nanowires show promise as being prime candidates for optical devices since they can be grown with band gaps spanning the visible spectra, while at the same time can be composed of stress free material. The goal of the work presented here was to obtain InGaN nanowires producing green emission at room temperature. Two growth recipes were found to yield InGaN nanowire growth on silicon substrates using plasma-assisted molecular beam epitaxy. At room temperature the photoluminescence (PL) of wire ensembles indeed peaked at 530 nm but, in addition, it was discovered that at low temperatures the emission often covered a broader (360-700 nm) spectrum. This broad optical range indicated indium content fluctuations in individual wires, wire-to-wire fluctuations, or a combination of the two. EDX measurements performed on single wires confirmed this hypothesis and correlated well with PL data. Low temperature PL studies of InGaN individual wires also revealed interwire and intrawire inhomogeneity of emission spectra stemming from a nonuniform indium distribution. The emission quantum yield for bright single wires was extracted to be more than 50% at 4 K. The findings suggest that the wire surfaces do not efficiently quench optical emission at low temperatures. These defect-free wires offer not only a potential path for green emitters, but also as integrated phosphors for broad spectral emission.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diluted magnetic semiconductor effects in Mn-implanted silicon carbide

Light transmission and Faraday rotation spectra measured at the temperature of 2 K were compared for silicon carbide single crystals of 4H polytype (4H-SiC), implanted with 3.8 x 10{sup 16} cm{sup -2} of Mn ions at the beam energy of 190 keV, and a control 4H-SiC single crystal sample, which was not implanted. Mn ion implantation led to the creation of a Mn-doped surface layer with the average Mn concentration of 10{sup 21} cm{sup -3} and a thickness of approximately 0.2 {mu}m. Transmission of light through the implanted crystal changed only slightly in comparison with the control sample, which however, corresponded to a relatively strong attenuation in the implanted layer. This was interpreted as a result of scattering, which emerges in the surface layer due to optical nonuniformities, created by the high energy ion irradiation. The presence of a thin Mn-ion-containing surface layer led, despite its small thickness, to noticeable changes in the sample Faraday rotation spectra. The estimated values of the Verdet constant for this layer were about three orders of magnitude larger and of opposite sign compared to the Verdet constant values of the undoped sample. Magnetic field dependencies of the Faraday rotation contribution from the implanted layer were found to be saturating functions, which points to a proportionality of the Faraday rotation to the magnetization of the paramagnetic Mn ion subsystem. Based on these findings we conclude that the Mn-implanted SiC layer exhibits magneto-optical properties typical of a diluted magnetic semiconductor. At the same time, no ferromagnetic ordering was observed in the studied (Si, Mn)C sample.

36 MATERIALS SCIENCE↗

Magnetic ordering and slow dynamics in a Ho-based bulk metallic glass with moderate random magnetic anisotropy

Results of magnetic measurements are presented for a Ho-based bulk metallic glass, which shows similarities and differences with conventional spin glasses (SGs), and significant differences with weak random magnetic anisotropy (RMA) systems. Both ac and dc magnetic measurements indicate a single transition from paramagnetic to speromagnetic or spin glasslike state around 5.6 K. The moderate RMA prevents the formation of long- (or quasilong)-range magnetic order and slows down the spin dynamics in the critical region. Further its isothermal remnant magnetization exhibits a small maximum, instead of a gradual increase with field in SGs. The roles of RMA in the magnetic structure and dynamics of disordered and frustrated systems are discussed by comparisons between the weak RMA system, the moderate or strong RMA system, and conventional SG.

36 MATERIALS SCIENCE↗

Broadband microwave spectroscopy in Corbino geometry at {sup 3}He temperatures

A broadband microwave spectrometer has been constructed to determine the complex conductivity of thin metal films at frequencies from 45 MHz to 20 GHz working in the temperature range from 0.45 K to 2 K (in a {sup 3}He cryostat). The setup follows the Corbino approach: a vector network analyzer measures the complex reflection coefficient of a microwave signal hitting the sample as termination of a coaxial transmission line. As the calibration of the setup limits the achievable resolution, we discuss the sources of error hampering different types of calibration. Test measurements of the complex conductivity of a heavy-fermion material demonstrate the applicability of the calibration procedures.

36 MATERIALS SCIENCE↗

A compact and miniaturized high resolution capacitance dilatometer for measuring thermal expansion and magnetostriction

We describe the design, construction, calibration, and two different applications of a miniature capacitance dilatometer. The device is suitable for thermal expansion and magnetostriction measurements from 300 K down to about 25 mK, with a resolution of 0.02 A at low temperatures. The main body of the dilatometer is fabricated from a single block of a Be-Cu alloy by electrical discharge milling. This creates an extremely compact high-resolution measuring cell. We have successfully tested and operated dilatometers of this new type with the commonly used physical property measurement system by quantum design, as well as with several other cryogenic refrigeration systems down to 25 mK and in magnetic fields up to 20 T. Here, the capacitance is measured with a commercially available capacitance bridge. Using a piezoelectric rotator from Attocube Systems, the cell can be rotated at T= 25 mK inside of an inner vacuum chamber of 40 mm diameter. The miniaturized design for the one-axis rotation setup allows a rotation of 360 Degree-Sign .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Momentum spectrometer for electron-electron coincidence studies on superconductors

We present a new experimental setup to study electron-electron coincidences from superconducting surfaces. In our approach, electrons emitted from a surface are projected onto a time- and position-sensitive microchannel plate detector with delayline position readout. Electrons that are emitted within 2 {pi} solid angle with respect to the surface are detected in coincidence. The detector used is a hexagonal delayline detector with enhanced multiple hit capabilities. It is read out with a Flash analog-to-digital converter. The three-dimensional momentum vector is obtained for each electron. The intrinsic dead time of the detector has been greatly reduced by implementing a new algorithm for pulse analysis. The sample holder has been matched to fit the spectrometer while being capable of cooling down the sample to 4.5 K during the measurement and heating it up to 420 K for the cleaning procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feedback cooling of cantilever motion using a quantum point contact transducer

We use a quantum point contact (QPC) as a displacement transducer to measure and control the low-temperature thermal motion of a nearby micromechanical cantilever. The QPC is included in an active feedback loop designed to cool the cantilever's fundamental mechanical mode, achieving a squashing of the QPC noise at high gain. The minimum achieved effective mode temperature of 0.2 K and the displacement resolution of 10{sup -11} m/{radical}(Hz) are limited by the performance of the QPC as a one-dimensional conductor and by the cantilever-QPC capacitive coupling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting quantum interference devices based set-up for probing current noise and correlations in three-terminal devices

We have implemented a new experimental set-up for precise measurements of current fluctuations in three-terminal devices. The system operates at very low temperatures (30 mK) and is equipped with three superconducting quantum interference devices (SQUIDs) as low noise current amplifiers. A SQUID input coil is connected to each terminal of a sample allowing the acquisition of time-dependent current everywhere in the circuit. From these traces, we can measure the current mean value, the noise, and cross-correlations between different branches of a device. In this paper, we present calibration results of noise and cross-correlations obtained using low impedance macroscopic resistors. From these results, we can extract the noise level of the set-up and show that there are no intrinsic correlations due to the measurement scheme. We also studied noise and correlations as a function of a dc current and estimated the electronic temperature of various macroscopic resistors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cantilever anemometer based on a superconducting micro-resonator: Application to superfluid turbulence

We present a new type of cryogenic local velocity probe that operates in liquid helium (1 K < T < 4.2 K) and achieves a spatial resolution of Almost-Equal-To 0.1 mm. The operating principle is based on the deflection of a micro-machined silicon cantilever which reflects the local fluid velocity. Deflection is probed using a superconducting niobium micro-resonator sputtered on the sensor and used as a strain gauge. We present the working principle and the design of the probe, as well as calibration measurements and velocity spectra obtained in a turbulent helium flow above and below the superfluid transition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronic and magnetic tunability of Sr{sub 2}CrReO{sub 6} films by growth-mediated oxygen modulation

Highly ordered epitaxial films of ferrimagnetic semiconductor Sr{sub 2}CrReO{sub 6} (SCRO) have been fabricated by off-axis magnetron sputtering, and characterized as a function of the oxygen partial pressure. In this Letter, we report 18 000% modulation in electrical resistivity at T = 7K (60% at room temperature) from a 1% modulation in the oxygen partial pressure during film growth. The growth window was centered at peak saturation magnetization, which drops due to both increasing and decreasing oxygen growth pressure. The results suggest that n-type doping due to oxygen vacancies plays a dominant role in the electrical properties and modulation of Sr{sub 2}CrReO{sub 6} thin films.

36 MATERIALS SCIENCE↗

Spin momentum density of Nd using Compton spectroscopy

Spin momentum density of Nd has been measured at 6K temperature using magnetic Compton scattering. The individual contribution of different electronic states, in the formation of total spin moment, is deduced from the analysis of magnetic Compton profile. The electron-specific spin moments deduced from the experimental Compton data are compared with the theoretical results obtained from full potential linearized augmented plane wave method and are found to be in good agreement.

36 MATERIALS SCIENCE↗

Weak ferromagnetic behavior of BiFeO{sub 3} at low temperature

Polycrystalline BiFeO{sub 3}, having a spherical shape with a diameter of about 78 {mu}m, has been synthesized by low-temperature hydrothermal method. The observed Raman and x-ray photo electron spectroscopy (XPS) spectra of the sample show the spectra of typical single-phased BiFeO{sub 3}, and the x-ray diffractometry (XRD) measurement further confirmed that the synthesized sample is single phase. The value of isomer shift from Moessbauer analysis indicates the Fe{sup 3+} ionic state without Fe{sup 2+} ionic state as observed from XPS measurement. The experimentally measured M-H curves show antiferromagnetic behavior at 295 K and weak ferromagnetic behavior at 4.2 K. The appearance of two different magnetic behaviors is due to the fact that the antiferromagnetic coupling becomes weak because of the presence of two distorted octahedral sites. Since the effect of the lattice distortion strongly depends on the thermal agitation effect, the weak ferromagnetic behavior can be observed only at 4.2 K. The detailed Moessbauer spectra analysis result confirms the existence of two distortion octahedral sites, which is in an agreement with XRD results.

36 MATERIALS SCIENCE↗

Strain modified/enhanced ferromagnetism in Mn{sub 3}Ge{sub 2} thin films on GaAs(001) and GaSb(001)

Ferromagnetic Mn{sub 3}Ge{sub 2} thin films were successfully grown on GaAs(001) and GaSb(001) substrates using molecular beam epitaxy. The results of our work revealed that the substrate facilitates to modify magnetic and electrical properties of Mn{sub 3}Ge{sub 2} films due to tensile/compressive strain effect between films and substrates. The characteristic spin-flopping transition at around 150 K for the bulk Mn{sub 3}Ge{sub 2} disappeared completely for both samples. The antiferromagnetism below 150 K changed to ferromagnetism and retained above room temperature. The saturation magnetization was found to be 0.23 and 1.32 {mu}{sub B}/Mn atom at 10 K for the samples grown on GaSb(001) and GaAs(001), respectively.

36 MATERIALS SCIENCE↗