Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “zinc batteries”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The electrical performance of Ag Zn batteries for the Venus multi-probe mission

An evaluation of 5 Ah and 21 Ah Silver-Zinc batteries was made to determine their suitability to meet the energy storage requirements of the bus vehicle, 3 small probes and large probe for the Venus multi-probe mission. The evaluation included a 4 Ah battery for the small probe, a 21 Ah battery for the large probe, one battery of each size for the bus vehicle power, a periodic cycling test on each size battery and a wet stand test of charged and discharged cells of both cell designs. The study on the probe batteries and bus vehicle batteries included both electrical and thermal simulation for the entire mission. The effects on silver migration and zinc penetration of the cellophane separators caused by the various test parameters were determined by visual and X-ray fluorescence analysis. The 5 Ah batteries supported the power requirements for the bus vehicle and small probe. The 21 Ah large probe battery supplied the required mission power. Both probe batteries delivered in excess of 132 percent of rated capacity at the completion of the mission simulation.

Palandati, C.↗

Nonleaking battery terminals

Three different terminals were designed for usage in a 40 ampere/hour silver zinc battery which has a 45 percent KOH by weight electrolyte in a plastic battery case. Life tests, including thermal cycling, electrical charge and discharge for up to three years duration, were conducted on these three different terminal designs. Tests for creep rate and tensile strength were conducted on the polyphenylene oxide (PPO) plastic battery cases. Some cases were unused and others containing KOH electrolyte were placed on life tests. The design and testing of nonleaking battery terminals for use with a potassium hydroxide (KOH) electrolyte in a plastic case are discussed.

Snider, W. E.↗

Nonleaking battery terminals.

Three different terminals were designed for usage in a 40 ampere/hour silver zinc battery which has a 45% KOH by weight electrolyte in a plastic battery case. Life tests, including thermal cycling, electrical charge and discharge for up to three years duration, were conducted on these three different terminal designs. Tests for creep rate and tensile strength were conducted on the polyphenylene oxide plastic battery cases. Some cases were unused and others containing KOH electrolyte were placed on life tests. The design and testing of nonleaking battery terminals for use with a KOH electrolyte in a plastic case are considered.

Snider, W. E.↗

Unveiling Charge Transport and Degradation Mechanisms of Aqueous Zn|α-MoO 3 Batteries in Conventional Concentration and Water-in-Salt Electrolytes: A Multi-Modal In Situ and Operando Study

Herein charge storage and transport properties are elucidated and cell degradation mechanisms of rechargeable aqueous Zn|alpha-MoO 3 batteries in three electrolyte systems (3 m ZnSO 4 , 3 m ZnCl 2 , and 30 m ZnCl 2 [12.5 m] water-in-salt (WIS)) are distinguished by a combination of in situ X-ray diffraction (XRD), in situ X-ray absorption spectroscopy (XAS), operando optoelectrochemistry, and operando energy dispersive X-ray diffraction (EDXRD). In conventional concentration 3 m electrolytes, in situ XRD and XAS, as well as ex situ scanning transmission electron microscopy data collectively support Zn 2+ as the primary charge carrier. In addition, these systems are susceptible to cathode dissolution, Zn corrosion coupled with the hydrogen evolution reaction, and the resultant formation of basic zinc salt phases. The multi-modal in situ and operando experimental analyses validate facile H+ intercalation and extraction in concentrated 30 m ZnCl 2 WIS electrolyte. Via operando EDXRD, reaction front and charge transport limitation during discharge and charge in the viscous WIS electrolyte are spatially tracked. Here this work provides new insight into the stability and degradation mechanisms of aqueous zinc batteries during static storage and upon dynamic cycling, and highlights the utility of in situ and operando techniques in understanding the superior stability of WIS electrolytes.

25 ENERGY STORAGE↗

Results of baseline tests of the EVA Metro sedan, Citi-car, Jet Industries Electra-van, CDA town car, and Otis P-500 van

Five electric vehicles were tested at vehicle test tracks using the SAE. The tests provide range data at steady speeds and for several driving cycles. Most tests were conducted with lead-acid traction batteries. The Otis Van and the Copper Electric Town Car were also tested with lead-acid and nickel-zinc batteries. The tests showed a range increase of from 82 to 101 percent depending on vehicle, speed, and test cycle.

Stenger, F. J.↗