Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind plant controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Germination, growth rates, and electron microscope analysis of tomato seeds flown on the LDEF

The tomato seeds were flown in orbit aboard the Long Duration Exposure Facility (LDEF) for nearly six years. During this time, the tomato seeds received an abundant exposure to cosmic radiation and solar wind. Upon the return of the LDEF to earth, the seeds were distributed throughout the United States and 30 foreign countries for analysis. The purpose of the experiment was to determine the long term effect of cosmic rays on living tissue. Our university analysis included germination and growth rates as well as Scanning Electron Microscopy and X-ray analysis of the control as well as Space-exposed tomato seeds. In analyzing the seeds under the Electron Microscope, usual observations were performed on the nutritional and epidermis layer of the seed. These layers appeared to be more porous in the Space-exposed seeds than on the Earth-based control seeds. This unusual characteristic may explain the increases in the space seeds growth pattern. (Several test results show that the Space-exposed seeds germinate sooner than the Earth-Based seeds. Also, the Space-exposed seeds grew at a faster rate). The porous nutritional region may allow the seeds to receive necessary nutrients and liquids more readily, thus enabling the plant to grow at a faster rate. Roots, leaves and stems were cut into small sections and mounted. After sputter coating the specimens with Argon/Gold Palladium Plasma, they were ready to be viewed under the Electron Microscope. Many micrographs were taken. The X-ray analysis displayed possible identifications of calcium, potassium, chlorine, copper, aluminum, silicon, phosphate, carbon, and sometimes sulfur and iron. The highest concentrations were shown in potassium and calcium. The Space-exposed specimens displayed a high concentration of copper and calcium in the two specimens. There was a significantly high concentration of copper in the Earth-based specimens, whereas there was no copper in the Space-exposed specimens.

Hammond, Ernest C., Jr.↗

Numerical Analysis of Offshore Wind-Farm-Induced Drag Effects on Coastal Upwelling Dynamics

Wind farms extract momentum from the atmospheric flow, generating wind-speed deficits both within the plant, and extending downstream. When located offshore, these deficits modulate air-sea coupling, potentially impacting coastal upwelling in sensitive regions. We investigate impacts of wind farms on coastal upwelling using kilometre-scale, three-way-coupled simulations with the coupled ocean-atmosphere-wave-sediment transport system for the US West Coast. Wind-farm effects are represented by a generalised turbine drag formulation, an idealised, height-dependent body force whose magnitude is systematically varied. This approach isolates the leading-order fluid-dynamical response in a realistic coastal configuration. The atmospheric adjustment exhibits an approximately linear relation between drag force and wind-speed deficit, with wakes that expand downstream and increase in magnitude as drag increases. An empirical orthogonal function analysis of sea-surface-temperature anomalies reveals the emergence of a canonical dipole pattern under strong drag forcing. Subsurface diagnostics show consistent shoaling of the mixed layer and suppressed upward velocities in areas near wind-farm region, accompanied by compensating enhancements of shoaling closer to the coast. These results identify turbine drag as a control parameter in assessing interactions between wind-farm wake and coastal upwelling and provide scaling relationships for understanding offshore wind-farm effects on the coastal circulation dynamics.

16 TIDAL AND WAVE POWER↗

Factors Impacting Nuclear Energy Share in U.S. Energy Markets

The purpose of this report is to collate information and findings from recent studies conducted by national and international bodies/institutes to identify approaches for maintaining/enhancing the role of nuclear energy in the current and future energy mix of the United States. This report shows how nuclear generation grew quickly to provide 20% of U.S. electricity, sustaining that level for three decades without the benefit of new construction, but is now projected to decline going forward. Nuclear construction costs in the U.S. spiraled out of control, ending construction for two decades and the recent resumption of construction has continued the pattern of schedule delays and cost overruns. However, nuclear operations exhibited strong learning, achieving and sustaining the highest capacity factor of any electricity generation technology and license extensions and uprates have sustained nuclear market share. The share of nuclear energy in the U.S. electricity market is projected to decline by ~1/3rd over the next 30 years The report provides an overview of how the markets work in theory and in practice. It indicates how market deregulation and clean energy policies have created conditions where nuclear plants are being retired for economic rather than technical reasons. The report also shows how many of the markets do not in practice have free competition but instead have outcomes that are being determined more and more by policy instead of market forces. While electricity costs from existing nuclear plants are low, electricity from new builds is projected to be too expensive to be competitive head-to-head with natural gas, even for nth-of-a-kind costs. Wind and solar energy have enjoyed an extended period of sustained subsidy. This protected environment has resulted in a sustained reduction in plant level costs to the point that some of these Variable Renewable Energy (VRE) technologies are becoming competitive even if their direct subsidies are removed. But plant level costs underestimate total VRE costs which include a number of system-level externalities. The incremental system value of additional VRE capacity was shown to decline as market share increases, with solar value declining more quickly than wind. The report closes with examination of a possible future for nuclear generation as part of deep decarbonization of the electricity sector. This approach avoids direct competition with natural gas. The two options for achieving 100% decarbonization are to use only renewables or to use all zero emissions technologies, and the report shows the second approach is much less expensive than the first.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Measurement of Effective Canopy Temperature: The Missing Link to Modeling Transpiration in Controlled Environments

The objectives were to apply energy balance principles to plant canopies, and to determine which parameters are essential for predicting plant canopy transpiration (E) in controlled environments. Transpiration was accurately measured in a gas-exchange system. Absorbed radiation (R(sub abs)) by the canopy was measured with a net radiometer and calculated from short and long-wave radiation components. Average canopy foliar temperature T(sub L) can be measured with an infrared radiometer, but since T(sub L) is seldom uniform, a weighed average measurement of T(sub L) must be made. The effective canopy temperature T(sub C) is that temperature that balances the energy flux between absorbed radiation and latent heat L(sub E) and sensible heat (H) fluxes. TC should exactly equal air temperature T(sub A) when L(sub E) equals R(sub abs). When unnecessary thermal radiation from the lighting system is removed by a water filter, the magnitude of L(sub E) from transpiration approaches Rabs and T(sub C) is close to T(sub A). Unlike field models, we included the energy used in photosynthesis and found that up to 10% of Rabs was used in photosynthesis. We calculated aerodynamic conductance for H from measurements of wind speed and canopy height using the wind profile equation. Canopy aerodynamic conductance ranged from.03 to.04 m/s for wind speeds from.6 to 1 m/s; thus a 0.1 C canopy to air temperature difference results in a sensible heat flux of about 4 W/sq m, which is only 1% of R(sub abs). We examined the ability of wide angle infrared transducers to accurately integrate T(sub L) from the top to the bottom of the canopy. We measured evaporation from the hydroponic media to be approximately 1 micro mol/sq m s or 10% of R(sub abs). This result indicates that separating evaporation from transpiration is more important than exact measurement of canopy temperature.

Monje, O. A.↗

Evaluation of the 7-km GEOS-5 Nature Run

This report documents an evaluation by the Global Modeling and Assimilation Office (GMAO) of a two-year 7-km-resolution non-hydrostatic global mesoscale simulation produced with the Goddard Earth Observing System (GEOS-5) atmospheric general circulation model. The simulation was produced as a Nature Run for conducting observing system simulation experiments (OSSEs). Generation of the GEOS-5 Nature Run (G5NR) was motivated in part by the desire of the OSSE community for an improved high-resolution sequel to an existing Nature Run produced by the European Centre for Medium-Range Weather Forecasts (ECMWF), which has served the community for several years. The intended use of the G5NR in this context is for generating simulated observations to test proposed observing system designs regarding new instruments and their deployments. Because NASA's interest in OSSEs extends beyond traditional weather forecasting applications, the G5NR includes, in addition to standard meteorological components, a suite of aerosol types and several trace gas concentrations, with emissions downscaled to 10 km using ancillary information such as power plant location, population density and night-light information. The evaluation exercise described here involved more than twenty-five GMAO scientists investigating various aspects of the G5NR performance, including time mean temperature and wind fields, energy spectra, precipitation and the hydrological cycle, the representation of waves, tropical cyclones and midlatitude storms, land and ocean surface characteristics, the representation and forcing effects of clouds and radiation, dynamics of the stratosphere and mesosphere, and the representation of aerosols and trace gases. Comparisons are made with observational data sets when possible, as well as with reanalyses and other long model simulations. The evaluation is broad in scope, as it is meant to assess the overall realism of basic aspects of the G5NR deemed relevant to the conduct of OSSEs. However, because of the relatively short record and other practical considerations, these comparisons cannot provide a definitive, statistically sound assessment of all model deficiencies, or guarantee the G5NR's suitability for all OSSE applications. Differences between the observed and simulated behavior also must be judged in the context of basic internal atmospheric variability which can introduce variations that are not necessarily controlled by the prescribed sea surface temperatures used in generating the G5NR. The results show that the G5NR performs well as measured by the majority of metrics applied in this evaluation. Particular benefits derived from the 7-km resolution of G5NR include realistic representations of extreme weather events in both the tropics and extratropics including tropical cyclones, Nor'easters and mesoscale convective complexes; improved representation of the diurnal cycle of precipitation over land; well-resolved surface-atmosphere interactions such as katabatic wind flows over Antarctica and Greenland; and resolution of orographically generated gravity waves that propagate into the upper atmosphere and influence the large scale circulation. Obvious deficiencies in the G5NR include a "splitting" of the inter-tropical convergence zone, which leads to a weaker-than-observed Hadley circulation and related deficiencies in the depiction of stationary wave patterns. Also, while the G5NR captures global cloud features and radiative effects well in general, close comparison with observations reveals higher-than-observed cloud brightness, likely due to an overabundance of cloud condensate; less distinct cloud minima in subtropical subsidence zones, consistent with a weak Hadley circualtion; and too few near-coastal marine stratocumulus clouds.

GEOS-5↗

Dynamic Model Development of a Wind Power Plant Using Neural Net Method to Forecast Wind Power Output (CRADA Final Report)

This project is intended to model wind power plant based on monitored data at the wind power plant. This project will promote the university research in Renewable Energy area and trains the future highly qualified engineers. The dynamic model will be based on neural net model with the input from the two met towers (12 inputs), and the number of turbines in operation (one input). The overall input will be 13 inputs to drive the simulations. The output power at the point of interconnection will be used to tune the neural net weight coefficients. Two neural net concepts will be investigated (the back propagation neural net and the dynamic recurrent neural net with feedback).

17 WIND ENERGY↗

Effects of physical agitation on yield of greenhouse-grown soybean

Agronomic and horticultural crop species experience reductions in growth and harvestable yield after exposure to physical agitation (also known as mechanical stress), as by wind or rain. A greenhouse study was conducted to test the influence of mechanical stress on soybean yield and to determine if exposure to mechanical stress during discrete growth periods has differential effects on seed yield. A modified rotatory shaker was used to apply seismic (i.e., shaking) stress. Brief, periodic episodes of seismic stress reduced stem length, total seed dry weight, and seed number of soybean [Glycine max (L.) Merr.]. Lodging resistance was greater for plants stressed during vegetative growth or throughout vegetative and reproductive growth than during reproductive growth only. Seed dry weight yield was reduced regardless of the timing or duration of stress application, but was lowest when applied during reproductive development. Seismic stress applied during reproductive growth stages R1 to R2 (Days 3 to 4) was as detrimental to seed dry weight accumulation as was stress applied during growth stages R1 to R6 (Days 39 to 42). Seed dry weight per plant was highly correlated with seed number per plant, and seed number was correlated with the seed number of two- and three-seeded pods. Dry weight per 100 seeds was unaffected by seismic-stress treatment. Growth and yield reductions resulting from treatments applied only during the vegetative stage imply that long-term mechanical effects were induced, from which the plants did not fully recover. It is unclear which yield-controlling physiological processes were affected by mechanical stress. Both transient and long-term effects on yield-controlling processes remain to be elucidated.

Non-NASA Center↗

Coatings for CSP Lifetime

The feasibility and performance of tower-technology-based concentrated solar power (CSP) is highly dependent on the efficiency of the energy transformation from sun to heat at the receiver. The higher the solar absorptivity of the receiver coating, the higher the efficiency of the plant as a whole. BrightSource Energy (BSE) has developed a series of High-Performance Coating (HPC) systems in order to achieve high absorptivity over the plant lifetime (25-35 years). This requires stable coatings that are easily applicable on the large receiver surface and will maintain their optical properties under intense solar flux and thousands of heating and cooling cycles in desert conditions. Different coating formulations are required according to the differing plant conditions: receiver materials, operating conditions (temperatures, daily cycles, etc.), and environmental conditions. BSE also developed a coating for the next generation of CSP receivers, such as those being under DOE’s CSP Gen3 program, which will be operated with high temperature heat transfer fluids at temperatures of up to 800°C, which is significantly hotter than the operating temperature of current systems. Once the coating is formulated, the next challenge is evaluating its lifetime properties. BSE has found several independent failure modes that impact HPC absorptivity degradation: • Decrease in HPC optical properties due to oxidation in the receiver tubes surface below the HPC; • HPC film deterioration due to cycling of temperatures and humidity due to daily operation startup and shutdown as well as changing ambient conditions; • Mechanical degradation due to erosion by sand and wind. Existing test methods examine various aspects independently, but do not provide a combined accelerated lifetime result. Creating such a combined test suite, with a way to interpret the results to predict the coating’s projected lifetime, was the ultimate goal of this project. The project was divided into three major workstreams: lab testing (individual failure mode tests and combined failure mode tests); developing a theoretical model for aging; and validation of the test apparatus via on-sun testing in near real-world conditions at CIEMAT-PSA. Developing a test apparatus that accurately controlled the temperature while also introducing the desired solar flux proved more challenging than expected. While in the end we did succeed in creating a test apparatus that can control temperature, solar flux, and humidity, the results did not appear to accelerate the lifetime of the samples as desired. We suspect that to properly accelerate the samples we must also subject the samples to increased amounts of oxygen. Similarly, while we successfully created a combined model that is publicly available, we were unable to validate it sufficiently to feel comfortable recommending it as a general guideline.

14 SOLAR ENERGY↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis – Simulated Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wind turbine. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen . While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the simulated wind energy profiles, NLR used OpenFAST to simulate a 3.4-MW International Energy Agency (IEA) reference wind turbine. The hour-long wind energy profiles varied over wind turbulence intensity (Class A or Class C) and average wind speed (5, 7, or 9 m/s). To match the power limits of the 1.25-MW electrolyzer and 3.4-MW IEA wind turbine most effectively and to maximize the efficiency of hydrogen production at a given average wind speed, the profiles were sometimes scaled by two times. This means that, in some cases, the experimental setup assumed two 1.25-MW electrolyzers were coupled with the wind turbine, representing a total maximum electrolysis load of 2.5 MW. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}-{average wind speed}-{turbulence class}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “windIEA3.4-5ms-C_2-400.zip” represents the hour-long experiment using the IEA 3.4-MW turbine, subjected to an average wind speed of 5 m/s and Class C wind turbulence, and connected to two 1.25-MW electrolyzers with the power supply set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wind turbine power. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis .

08 HYDROGEN↗

Using Machine Learning Tools to Predict Compressor Stall

Clean energy has become an increasingly important consideration in today’s power systems. As the push for clean energy continues, many coal-fired power plants are being decommissioned in favor of renewable power sources such as wind and solar. However, the intermittent nature of renewables means that dynamic load following traditional power systems is crucial to grid stability. With high flexibility and fast response at a wide range of operating conditions, gas turbine systems are poised to become the main load following component in the power grid. Yet, rapid changes in load can lead to fluid flow instabilities in gas turbine power systems. These instabilities often lead to compressor surge and stall, which are some of the most critical problems facing the safe and efficient operation of compressors in turbomachinery today. Although the topic of compressor surge and stall has been extensively researched, no methods for early prediction have been proven effective. This study explores the utilization of machine learning tools to predict compressor stall. The long short-term memory (LSTM) model, a form of recurrent neural network (RNN), was trained using real compressor stall datasets from a 100 kW recuperated gas turbine power system designed for hybrid configuration. Two variations of the LSTM model, classification and regression, were tested to determine optimal performance. The regression scheme was determined to be the most accurate approach, and a tool for predicting compressor stall was developed using this configuration. Overall, results show that the tool is capable of predicting stalls 5–20 ms before they occur. With a high-speed controller capable of 5 ms time-steps, mitigating action could be taken to prevent compressor stall before it occurs.

42 ENGINEERING↗

CROCUS Urban Fluxes of CO₂, H₂O, and Turbulence at University of Illinois Chicago

As of May 12, 2026 this dataset is currently being versioned to include data up to April 2026. Once the versioning process is complete, new data files will be available for access. The dataset metadata will also be updated to reflect the data availability of the new data being versioned. This dataset was collected at the UIC Plant Research Laboratory in Chicago, Illinois, as part of the Community Research on Climate and Urban Science (CROCUS) Urban Integrated Field Laboratory (UIFL) project, led by Argonne National Laboratory. The site provides continuous atmospheric flux measurements, focusing on CO₂, H₂O, and heat and momentum transport in an urban setting. The data is processed at 30 minutes interval using the Eddy Covariance method and includes quality control and diagnostic data generated by EddyPro software. The data is stored in the netCDF files following CF conventions. The UIC Plant Research Laboratory is located near major highways and urban infrastructure, including buildings and parking areas. The surrounding landscape consists of a mix of turf, plants, trees, and impervious surfaces such as concrete and asphalt, making it ideal for studying urban at for studies on urban sustainability, air quality, and the effects of urbanization on atmospheric processes on urban climate dynamics, air quality, and surface-atmosphere exchanges within the city of Chicago. This dataset is funded by the U.S. Department of Energy’s Office of Science, Biological and Environmental Research (BER) program.

54 ENVIRONMENTAL SCIENCES↗

Genesis Solar Wind Sample Curation Documentation

Introduction: A scientist with experience as a sample science analyst, provider of flight hardware for multiple missions, and senior engineer in an ISO 2000-rated manufacturing plant has described the timeline of key participants in any PI-led sample return mission, the breadth of the organizations involved [1,2], and, of interest to this meeting, choosing the types of data to preserve and issues of future data accessibility. This work broadens that perspective by giving similar lessons from Genesis sample curation point-of-view. Curation participation regarding data gathering was part of the mission review process from the beginning. Genesis’ story illustrates outcome of several choices about types of data to record and preserve. Precision analysis of solar wind atoms captured in pure, ultraclean substrates is the driving science goal; therefore, detailed documentation was captured from all mission and curation phases and from investigator laboratories because these processes affect the final analytical results [3]. Pre-flight: Design and fabrication of the spacecraft. Like many modern small sample return missions, Genesis was a tightly managed team integrated across science, engineering and curation. Communication across the team was excellent, and, for the most part, the hands-on engineering technicians understood the impacts of “small choices” they routinely make, and the eyes-on oversight of manufacturing processes by scientists was mindful of details. The payload was designed by the Jet Propulsion Laboratory and the spacecraft by Lockheed Martin. Solar wind collectors and instruments were fabricated by multiple vendors and laboratories. The main portion of the payload was assembled at JSC. Fabrication procedures and contamination-control data (with witness coupons) were stored primarily at JSC. The original composition, dimensions and configuration of components, results of thermal testing, etc. are still needed for interpretation of analytical data. At times, these must be estimated from secondary information acquired pre-flight. Moreover, some files (e.g., original 3-D models and early Powerpoint) cannot be opened using software. Archived curation data includes 2-D drawings, material usage lists, QA documentation and analyses of consumables used during fabrication. Important chemical information still resides in archived hardware, paints and lubricants, material coupons, cleaning coupons, environmental witness plates and reference materials from manufacturing facilities. Purity and cleanliness of collector substrates. Semi-conductor vendors provided surface cleanliness data and some purity data. Purity for specific elements of interest was verified by science team members in their laboratories [4]. Curation archived procurement and shipping records, analysis reports, and non-proprietary fabrication data. A physical archive of flight collector reference materials is maintained for future use so additional data can be collected as analytical techniques improve. These are of increased value due to the hard landing upon re-entry. Cleaning and cleanliness assessments of flight hardware. Cleaning of the science canister payload was performed at JSC in a dedicated ISO 4 cleanroom using ultrapure water (UPW). The cleanliness of this UPW was monitored throughout processing. The archive for the clean lab also includes airborne particle counts, airborne molecular and inorganic contamination measurements as well as cleanroom construction material coupons and witness coupons. Hardware cleanliness was assessed by particle counts in rinse water batches. This information is recorded in batch cleaning forms and logbooks, and are, perhaps, of decreased value due to the hard landing. Post-flight: Curation-generated data. The curation handling history of each Genesis sample is documented in a typical astromaterials sample database which captures sample location, physical description and characterization data. Samples have a “shelf life”. Crucial to the preservation of samples is ongoing documentation of the sample environment, initially under curatorial control but is now a separate facility function with requires coordination. PI-generated data. Data on sample characterization and cleaning techniques continues to be generated by sample users [5]. These are often captured in LPSC abstracts, but these “engineering” results often are not publishable as stand-alone papers. We are actively looking for ways to make this information more accessible to users. Ion implants into samples have aided science return and can be shared among investigators. These (and similar) materials should be added to the curatorial collection with appropriate process and characterization data generated externally. Summary: Complete data archives for returned astromaterial samples must be broad in types and formats, and inclusive of environmental monitoring.

Genesis↗

Upgrading Biogas through in situ Conversion of Carbon Dioxide to Biomethane in Anaerobic Digesters

Organic waste streams generated by wastewater treatment plants, agricultural operations, and food processing industries represent an important yet underutilized opportunity for renewable energy production in the United States. Through anaerobic digestion, these waste streams can produce biogas, a mixture primarily composed of methane (CH4) and carbon dioxide (CO2), that can be upgraded to pipeline-quality natural gas. However, most existing upgrading technologies remove CO2 from biogas rather than utilizing it, leaving a significant portion of the potential energy unused. This project investigates a novel biological upgrading approach that converts CO2 into additional CH4 by supplying hydrogen (H2) to specialized microorganisms capable of performing hydrogenotrophic methanation. The main challenges associated with biological biogas upgrading are related to hydrogen supply, gas-liquid mass transfer, and process stability. First, due to the high cost of hydrogen gas, it is preferable that H2 be produced on-site using renewable energy sources such as wind or solar power. Second, hydrogen has low solubility in liquids, which limits its availability to microorganisms and requires strategies to improve gas dissolution and transfer within the reactor. Third, process inhibition may occur as a result of increased pH caused by CO2 consumption or elevated H2 partial pressure, both of which can negatively affect methanogenic activity. Although research in these areas has advanced during the course of this project, these challenges have not yet been fully resolved. To date, the biological systems that have achieved the highest methane concentrations are typically ex-situ reactors, where operational conditions can be more easily controlled. For this reason, the findings of the present project remain highly relevant. The project goal was to develop an innovative system that can accomplish biogas upgrading via biological conversion of CO2 to CH4, in a novel hybrid approach that combines the advantages of both in-situ and ex-situ systems. The proposed system employs a three-phase upflow anaerobic bioreactor with H2 delivery through a gas-permeable membrane, enabling efficient hydrogen transfer and microbial conversion. Under optimized operating conditions, the system achieved 99% H2 consumption and 90% CO2 conversion. A subsequent gas cleaning stage was implemented to further improve gas quality and meet target purity standards. The upgraded gas composition reached 97.7% CH4, 2.2% CO2, and 0.97% O2, while H2S concentrations remained below detection limits. In addition, a flue gas-driven inorganic thermoelectric generator (TEG) system was designed and experimentally validated as a potential source of electricity for H2 production. The system consisted of six TEG modules connected in series and achieved an open-circuit voltage of 4.5 V and a maximum power output of 224 mW at a temperature difference of approximately 53.5 °C, demonstrating effective conversion of waste heat into electrical power under simulated flue gas conditions. Finally, a comprehensive techno-economic analysis was completed to evaluate the capital and operating costs associated with the proposed system. The results provide important insights to guide future scale-up, optimization, and potential deployment of integrated biological biogas upgrading technologies.

09 BIOMASS FUELS↗

High-Efficiency Modular SiC-based Power-Converter for Flexible-CHP Systems with Stability-Enhanced Grid-Support Functions

This project seeks to develop a modular, scalable MV power converter featuring stability-enhanced grid-support functions for future grid-interface applications in flexible combined heat and power (F-CHP) cogeneration plants, being fully compliant with the IEEE Standard 1547, category B—for operation in local areas with high aggregated distributed energy resource (DER) penetration, and also with the IEEE standard for the specification of microgrid controllers, namely IEEE Std 2030.7, with the goal to enable F-CHP systems for both microgrid and standalone applications. Further, the proposed converter will use a modular circuit topology, the MMC, which is scalable both in voltage and current by interconnecting power-cell building blocks, thus flexibly suiting the needs of F-CHP systems in the 1–20 MWe range. Furthermore, the use of 10 kV SiC MOSFET devices will minimize the number of power-cells needed to operate in 2–13.8 kV MV distribution systems, but more importantly, they will render feasible a power conversion efficiency > 98 %, and a power density > 10 kW/l. This is highly relevant given that these are two key performance metrics that will further increase the value of F-CHP systems by shortening the time required to recover their investment costs.

14 SOLAR ENERGY↗

Long-term effects of thinning and woody control on longleaf pine plantation development, understory abundance, and tree damage from an ice storm

Longleaf pine (Pinus palustris) plantations have been established across the southeastern United States as the first step in restoring the declining savanna ecosystem, yet their long-term stability and development to open canopied woodlands may depend on early density and vegetation management treatments. Commercial thinning (CT) was applied in 2012 (year 18) to a long-term study of longleaf pine community restoration at the Savannah River Site near Aiken, SC to increase abundance of herb species. Although precommercial thinning (PCT) and woody vegetation control increased herb species cover during the first five years of the study, measurements from years 17 to 22 indicated a continuing decline in their cover since year 9 despite application of CT in year 18. Herb species richness, however, increased from 21 to 43 species per 100 m2 area during the last six years of the study, likely a result of disturbances associated with CT and an ice storm in year 20. Application of PCT in 1994, when the plantations were 8–11 years old, reduced their susceptibility to stem bending and breakage from the ice storm, which occurred 20 years later in 2014. Measured 5 months before the storm, pine height: dbh ratio (HD) averaged 78 and 90 for trees growing with and without PCT, respectively, and stem breakage (% of trees) from the ice storm increased linearly (r2 = 0.53) with HD. Pine mortality from the combined effects of glaze ice and wind differed with (28%) versus without (45%) PCT, indicating that long-term stability of longleaf pine plantations depends on early density management.

54 ENVIRONMENTAL SCIENCES↗

Update of Emission Factors of Greenhouse Gases and Criteria Air Pollutants, and Generation Efficiencies of the U.S. Electricity Generation Sector

The last decade has seen a steady evolution of the electricity generation sector. Fuels used for electricity generation have shifted from coal to cleaner energy sources such as natural gas and renewables including solar, wind, and other renewable sources. The share of U.S. electricity generated from coal decreased from 45% in 2010 to 24% in 2019, and is expected to decrease further to 13% by 2050. The conversion efficiency of electricity generation has also increased gradually for fuels such as natural gas due as less-efficient old generators are retired and more-efficient generators replace them. These changes in the electricity generation industry are likely to cause changes in the emissions from power generation units. Emission factors of greenhouse gases (GHG) including CO 2 , CH 4 , and N 2 O, and criteria air pollutants (CAPs) including CO, NO x , PM 10 , PM 2.5 , and SO x , from power plants are important parameters for estimating life-cycle emissions associated with vehicle electrification, energy systems, and the production of materials and chemicals. The electricity generation technologies and associated emission factors in the Greenhouse Gases, Regulated Emissions, and Energy Use in Technologies (GREET) model need to be updated to reflect recent developments in the electricity generation sector. The most recent update of the electricity generation emission factors in GREET adopted a mixed method. The emission factors of CH 4 , N 2 O, NO x , and SOx were estimated using a “topdown” approach by dividing the total emissions by the total net electricity generation, because emission data of these pollutants are readily available in the Emissions & Generation Resource Integrated Database (eGRID). For other CAPs such as CO, VOC, PM 10 , and PM 2.5 , emission data were not reported in eGRID. A “bottom-up” method was used to estimate the emission factors for these pollutants by considering generic uncontrolled emission factors and the pollutant removal efficiencies of emission control technologies adopted in the electricity generation sector. However, the uncontrolled emission factors and the emission removal efficiencies of various emission control technologies considered in the 2012 study came from the legacy AP-42 emission factors, and may not reflect the actual emission performances of the electricity generation sector of today. To leverage new data that recently became available, especially emission data measured from continuous emission monitoring systems (CEMS), we developed a new “top-down” approach to estimate efficiencies and GHG and CAP emission factors for electricity generation from combustion of individual fuel types by individual combustion technologies on the basis of power-generation data from U.S. Energy Information Administration’s (EIA’s) form EIA-923, and plant emission data from Environmental Protection Agency’s (EPA’s) Clean Air Markets Division (CAMD) dataset and National Emissions Inventory (NEI) dataset. Detailed discussion of the method and data used in this study can be found in Section 2.1. With this topdown approach, we aim to improve the estimates of energy efficiencies and emission factors for power plants using a more consistent methodology, and to update the emission factors, generation efficiencies, and generation technologies mixes in GREET to reflect recent technology advancements in the electricity generation sector.

20 FOSSIL-FUELED POWER PLANTS↗

Understanding Transient Combustion Phenomena in Low-NO x Gas Turbines

The goal of this work was to understand, quantify, and eventually predict combustion instability during operational transients in low-NO x gas turbine combustors. Transient operation is defined as a mode where one or more key operating parameters, including equivalence ratio, fuel composition, or fuel splitting between nozzles in a combustor, are varying in time. The timescale over which this variation occurs will be referred to as the transient timescale, the magnitude of the change in the transient parameter will be referred to as the transient amplitude, and the direction of the variation will be referred to as the transient direction. Transients occur regularly in power generation gas turbine operation. For example, load-following gas turbines vary load to meet power demands while accounting for variation in unsteady grid contributors like wind and solar power. Operators achieve this by varying equivalence ratio and fuel splitting inside the combustors to produce more or less power. Another example of transient operation is during fuel-switching operations, a particular issue for turbines operating with syngas fuels in a co-generation facility. In this case, the composition of the fuel stream may vary in time either as a result of fluctuations in the pipeline, or in the case of a co-generation plant, variations in feedstock or gasification processes. This fluctuation in fuel composition can have significant implications for combustion processes, particularly with high-hydrogen fuels. A small number of studies have investigated transient behavior in gas turbine combustors, particularly in the context of flame blow-off; here, investigators have typically focused on issues of transient amplitude, though without the depth and physics-based experimental design that is proposed in this program. To our knowledge, there have been no studies that have quantified the impact of the transient timescale on combustion. The work helped us understand the impact of several types of transients on combustion stability. Both static and dynamic combustion stability will be considered. The transients will be quantified using their amplitude, direction, and timescale, and we will consider transients in equivalence ratio, fuel composition, and fuel splitting. There were two main objectives of this work: 1. Provide a fundamental understanding of combustion stability during transient operation using data obtained from a number of high-speed diagnostic techniques on experimental configurations that capture important gas turbine combustor features and operating conditions. This goal was met in conjunction with our industrial partner, GE Global Research, with whom we worked closely throughout the program. 2. Develop a stability prediction framework that will allow for the prediction, and possible control, of instabilities as a function of the transient amplitude, direction, and timescale. This input/output model should be physics-based and allow for screening of operating conditions and prediction of unstable behavior at the end of a transient by monitoring combustor health and precursor signals during operation.

03 NATURAL GAS↗

Foundations for the Future Power System: Inverter-Based Resource Interconnection Standards

As power systems evolve to become reliant on solar, wind, batteries, and other inverter-based resources (IBRs), it is essential that those resources meet certain minimum performance and capability criteria designed to ensure the power system operates stably and reliably. Because those criteria, as enshrined in interconnection standards, take years to develop and are very long lived, they need to account for not only the present state of the power system but also its expected future state over the lifetime of the power plants to which they will apply. In addition, they need to be specific enough to ensure reliability without over specifying and, thereby, impeding innovation. Because power systems are shifting rapidly from a state where IBRs make up a small to medium portion of generation to one where the generation will, at times, come predominantly from IBRs, interconnection standards are especially challenging to develop today. Good interconnection standards can make the power system more reliable and less costly to operate, whereas poorly designed standards can lead to major problems, like the famous German 50.2-Hz problem, which introduced a risk of losing many gigawatts of solar on a frequency excursion and resulted in many IBRs being retrofitted at great cost to mitigate a major system reliability risk. Readying the power system by specifying forward-looking technical minimum functional capabilities for IBRs can be an effective approach to avoid future retrofits.

data models↗