Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of He-Ion Radiation on Solid-State Uranyl Nitrate Compounds under Dry and Hydrated Atmospheric Conditions

Radioactive decay of uranium (U) and its related daughter/fission products emit ionizing radiation, including γ (γ) rays and α (α) particles, that result in the formation of radical species and induce chemical reactivity in materials. While radioactivity is inherent to the chemistry of U there are limited studies that detail changes at an atomistic level. Here, this work describes the He-ion radiolysis of four solid-state U(VI) species: [UO 2 (NO 3 ) 2 ]·3(H 2 O) and M[UO 2 (NO 3 ) 3 ] (M = K + , Rb + , Cs + ). These materials were irradiated under different conditions (i.e. closed, open – Ar gas, or open – H 2 O-saturated Ar gas) to further evaluate the impact of water radiolysis on the chemical modification of these materials. Pre- and post-irradiation analyses were conducted using EPR, Raman, and ATR-IR spectroscopy on materials irradiated to 0, 5, 10, and 25 MGy. The results indicated the presence of nitrate radical (NO 3 • ) formation in all solid-state materials with similarities to those observed in γ-radiation studies. Irradiation of [UO 2 (NO 3 ) 2 ]·3(H 2 O) did not show evidence of reactive oxygen species bound to the U(VI) cation under inert conditions; however, surface reactivity was observed for samples irradiated in the H 2 O-saturated environment. Similar chemical changes were observed in the uranyl trinitrato compounds irradiated in the presence of H 2 O vapor and there were observed differences in the reactivity depending on the identity of the alkali cation.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

A Synoptic System for Capturing Ecosystem Control Points Across Terrestrial‐Aquatic Interfaces

Interconnected landscape features such as terrestrial‐aquatic interfaces play an outsized role in biogeochemical cycles as ecosystem control points, but it is notoriously challenging to characterize these. Here, we document a synoptic sensor network design that is (a) flexible to accommodate diverse ecosystem interfaces and gradients, (b) adaptable to monitoring and modeling needs of small and large projects alike, (c) standardized for intercomparability across sites and field experiments, and (d) adequately replicated to capture heterogeneity of each parameter monitored. This real‐time monitoring of surface water, groundwater, soil, and vegetation supports configuration and evaluation of models that span upland, wetland, open water strata, and transitions between them. We established the network at seven sites along the Chesapeake Bay and Lake Erie coastlines, including large‐scale flood manipulation experiments in both regions. A central design element is “one data logger program to rule them all”—a collection of sensor‐specific modules deployed on 40 loggers controlling ∼2,000 sensors, with the goal of streamlining maintenance, debugging, and reproducible data processing. The network generates ∼6 M observations per month, capturing system dynamics at the broad spatial and fine temporal scales needed to initialize and benchmark models; measurement frequency can be modified remotely to capture events. This network design has also revealed behaviors not represented in Earth system models, such as transient groundwater oxygen pulses. Completely documented and open source, this standardized, flexible, and efficient sensor network design can reduce barriers to understanding environmental changes and ecosystem responses across systems and scales.

Ward, Nicholas D. [Pacific Northwest National Labo↗

Development and Evaluation of Distributed Energy Resource Device Models: Electric Vehicles, Electric Water Heaters, and Commercial Refrigeration Systems

In order to validate distributed energy resource (DER) models operated with grid services in the GMLC 1.4.2 team’s February (GMLC 2019a) and July (GMLC 2019b) reports, a test and measurement program using actual DER devices was conducted by national laboratories for three devices: (1) electric vehicles (EVs), (2) water heaters, and (3) commercial refrigeration. Test procedures were developed and carried out to identify the mathematical models and their parameters that describe the operational function, characterize the physics, and obey transient response of the devices. This report focuses on the experimental results obtained to develop and verify simulations of three specific EV models. This section summarizes elements of the mathematical model and shows the necessity data collected from the EVs while charging and discharging (driving). In the course of the study, we found it necessary to make some modifications to the model to deal with observed transient behavior. Section 1.2 details the model assumptions and equations, Section 1.3 provides details of the EVs tested, Section 1.4 outlines the test procedures developed for the projects, and Section 1.5 presents the experimental results obtained for the three different EVs tested and how these results compare to the models running the same test profiles.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Investigation of a Novel Membrane-Based Condensing Heat Exchanger for High Efficiency Furnaces

Building space heating consumes approximately one-third of all global natural gas end use. Higher-efficiency (i.e., condensing) furnaces constitute only about 30% of the annual furnace shipments in the United States because the condensing heat exchangers must use highly expensive, corrosion-resistant materials to be protected from acidic components in the furnace flue gas stream. Increasing the market share of high-efficiency furnaces will reduce greenhouse gas emissions. This study developed and tested a benchtop prototype of a novel membrane-based heat exchanger (MHX) for high-efficiency furnaces to achieve nonacidic condensation via nanoporous membranes. Test results show that both sensible and latent heat were recovered by the MHX, and the fraction of latent heat recovery ranged from about 25% to 45% over the range of operating conditions evaluated. The amount of water condensed through the MHX increased with the increase of flue gas flow rate and decreased with increasing coolant temperature. The fraction of latent heat recovery decreased with the increase of flue gas flow rate and coolant temperature. The pH value of condensed water from the MHX was only mildly acidic, varying from 5.3 to 5.6 without any additional treatment, about 2.0 to 2.3 pH points higher (i.e., less acidic) than typical values for the condensate from conventional condensing furnaces. Therefore, feasibility of the MHX was experimentally verified, and the MHX could enable wider market penetration of highly energy-efficient condensing furnaces by reducing costs associated with managing the acid condensation compared with conventional condensing furnaces, possibly enabling the use of existing vent systems when replacing noncondensing furnaces (due to higher flue gas exit temperatures), and possibly reducing furnace first costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine (Final Report)

As the nation continues to encourage, through market structures and financial incentives, the proliferation of intermittent renewable electricity, how to optimize the ever-changing electric grid and identify means to retain and improve resilience, while ensuring continued reductions in GHG emissions, will be critical. According to Bloomberg, wind & solar generated 10.5% of US electricity in 2020 and that percentage continues to grow. In support of expanding renewable energy use, and to address its intermittent nature, this project will develop the Hydrogen Storage for Flexible Fossil Fuel Power Generation platform that is dispatchable, reliable, repeatable and have the ability to produce zero or negative carbon power while interfacing with geology capable of CO2 and hydrogen storage. GTI Energy (GTIE) and team members Illinois State Geological Survey (ISGS), Mitsubishi Heavy Industries America (MHIA), Ameren Illinois, Hexagon Purus, and the Low Carbon Resources Initiative (LCRI) completed a Phase I Conceptual Study under contract DE-FE0032012 for Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine. The Hydrogen Storage for Flexible Fossil Fuel Power Generation platform addresses the intermittent nature of the expanding use of Variable Renewable Energy (VRE) generation. The low cost of the electricity (COE) generated results in greater dispatch and more operation at higher power levels (higher efficiency), fewer short intervals, and fewer start/stop cycles. The reliable, resilient system can produce zero carbon power and store hydrogen. It will demonstrate hydrogen storage in geologic formations like those used in natural gas underground storage thus enabling large scale storage of hydrogen in sedimentary strata across the United States rather than in geographically restricted salt caverns. The Phase I study confirmed the system is feasible and generates power at lower cost than other low carbon approaches. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production. The study advanced the maturity of the H 2 storage-based system with flexible power generation by completing a Pre-FEED study (Phase II). The Pre-FEED focused on the selected Energy Farm on the University of Illinois Urbana-Champaign (UIUC) site that includes above ground and underground hydrogen storage, low-carbon hydrogen production (GTI’s Compact Hydrogen Generator, CHG) with underground CO2 sequestration, and a 40-MW class gas turbine. The Pre-FEED addressed the entire system and its interconnection to the natural gas and electric grid and mitigation of key risks, such as storage behavior, load-following, and system operation. During Phase 1 of the project, the team completed key tasks, which moved the entire demonstration project, specific components and approaches closer to commercialization. These Phase I Accomplishments include: Completing System Requirements Review; Completing System Layout and Modeling - Heat & Mass Balance and Process Flow Diagram; Completing modelling of 9 turbine performance cases; Evaluating rock strata for underground storage of hydrogen and sequestration of carbon dioxide; Completing initial modelling of underground storage of hydrogen and withdrawal with evaluation of loss and water production; Identifying roadable storage for above ground hydrogen storage; Identifying existing electrical infrastructure for receiving/delivering electricity; Identifying existing gas supply infrastructure for receiving natural gas; Document concept design/development plans in required reports. Conclusions: The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and generates power at lower cost than other low carbon approaches and even lower cost than the reference NGCC plant without carbon capture when taking advantage of 45Q carbon credits. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via the system requirements review with the whole team. These requirements were then incorporated into and iterated with our Heat & Mass Balance process model and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Large scale non-salt geologic storage of hydrogen is an enabling technology for a hydrogen-fired turbine that can be retrofitted into large-scale electric generating units (EGU). Our demonstration will include 428 MWh or ~4 hours full load of hydrogen storage (above and underground). Carbon capture inherent to the CHG process can capture 90% CO 2 (with upgrades to >98%). This system provides a COE of 23% savings relative to an NGCC with a post combustion amine system. Our proposed storage system decouples carbon capture and hydrogen production from power production; therefore, we expect our proposed system’s efficiency and variable COE to be superior resulting in overall higher dispatch and reduced deep cycling. Our demonstration will be full to multi-day hydrogen storage and has the potential for longer (seasonal) duration commercially. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production.

03 NATURAL GAS↗

Mechanical Testing of Additively Manufactured Materials

This report summarizes research activities conducted at Argonne National Laboratory in support of the development, qualification and certification of additively manufactured (AM) metallic components to allow for innovative reactor design and licensing. In this program, AM 316L stainless steel (SS) was evaluated in both light water reactor (LWR) environments as well as at higher temperatures expected in advanced reactors.

36 MATERIALS SCIENCE↗

Major Ion Toxicity to Glochidia of Common and Imperiled Freshwater Mussel Species

Freshwater mussel taxa are severely imperiled and among the most sensitive to several contaminants, including chloride. Relatively little is known of the toxicity of major ions to glochidia (larvae), particularly for rare species, or the effects of hardness on major ion toxicity to glochidia. Therefore, the primary objectives of this work were to: (1) determine the acute toxicity of major ion salts to glochidia, (2) compare chloride sensitivity of glochidia from common and rare species, and (3) evaluate the relationship between water hardness and chloride toxicity to glochidia. We assessed 24 h EC50s for fatmucket (Lampsilis siliquoidea) glochidia exposed to NaCl, KCl, MgCl 2 , CaCl 2 , Na 2 SO4, MgSO 4 , CaSO 4 , and NaHCO 3 in moderately hard water. We determined NaCl EC50s for four species and KCl EC50s for glochidia of three species. Toxicity of chloride was generally consistent among the various chloride salts except for KCl, which was more toxic than all others by 1–2 orders of magnitude. Our results suggest that commonly tested species may be generally representative of rare species. Water hardness ameliorated the toxicity of chloride for all species to varying degrees. Results of this work indicate that some existing water quality criteria that do not include mussel toxicity data may not be protective of freshwater mussels.

59 BASIC BIOLOGICAL SCIENCES↗

Rice Bran Stabilisation and Oil Extraction Using the Microwave-Assisted Method and Its Effects on GABA and Gamma-Oryzanol Compounds

Rice bran oil (RBO) is a valuable ingredient extracted from rice bran (RB), a side stream of polishing rice grain in the milling process. RBO is rich in bioactive ingredients with potential health benefits, such as gamma-oryzanol (GO) and gamma-aminobutyric acid (GABA). Despite its benefits, the quality of RBO depends on the degree of stabilisation of the RB, which is easily affected by lipase enzymes, and thus needs an effective treatment prior to RBO production. To assess the potential of the microwave-assisted method for RB stabilisation and RBO extraction, three Carolino rice varieties (Ariete, Teti, Luna) were tested. The effect of RB stabilisation was evaluated via acid value, water absorption, and GO and GABA levels. The RBO yield was optimised by solvent, temperature, and solvent-to-sample ratio, and the GO and fatty acid levels were determined. The RB stabilisation for the Luna variety did not affect the GO and GABA; for the Ariete and Teti varieties, the GO decreased by 34.4% and 24.2%, and the GABA increased by 26.5% and 47.0%, respectively. The GO levels in RBO samples were not affected by RB stabilisation. The RBO nutritional value was confirmed by the suitable ratio (>2) between polyunsaturated (PUFA) and saturated fatty acids (SFA), with the Teti variety presenting the highest ratio.

Reis, Núria (ORCID:0000000194339109)↗

Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters

Future utilities will emphasize home appliances to reduce greenhouse gas emissions while providing electric load shifting and demand profile management. Heat pump water heaters (HPWH) have demonstrated the ability to cut water heating energy by more than 65% compared with conventional electric resistance waters (ERWH). Laboratory research was conducted on the load shifting potential of grid-connected heat pump water heaters (HPWH), compared to ERWHs. Testing applied different CTA-2045 command designs. Highly-controlled laboratory experiments were conducted on one ERWH and four HPWHs, including a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load up above the tank setpoint. The prototype unit with the B-protocol increased tank temperature by 15oF (8.3C) under the advanced load up providing an increase of 1.8 kWh of storage for a 50-gallon (189 liter) tank. The prototype includes a built-in mixing valve to meet anti-scalding codes. With the load-shaping ability of CTA-2045-B, utilities might be able to store excess renewable energy in connected tanks when renewable wind and solar resource production is high. Tests were performed under baseline conditions (no load shift) and under several load-shifting schemes, including load up and advanced load up, ahead of shed commands. Grid-connected HPWHs reduced peak demand by as much as 0.5 kW, depending on tank volume, time of day, control scheme, and draw profile.

heat pump water heater, Demand flexibility, load s↗

A Propane Hydronic Heat Pump with Energy Storage

Propane is an environment-friendly refrigerant, having a 20-year GWP (global warming potential) of 0.072 and a 100-year GWP of 0.02, as compared to R-410A having a GWP > 2000. It has superior thermodynamic cycle performance and heat transfer characteristics. However, propane is classified as a A3 refrigerant, which is highly flammable, and not allowed to be used indoor if the system charge is higher than 150 grams. It is a challenge to use propane in residential applications requiring a rated capacity larger than 10 k Watts. A hydronic heat pump, i.e., containing propane in an outdoor unit and distributing the cooling and heating capacity through a hydronic coil to the indoor space addresses the flammability issue, while maintaining a high efficiency. We developed a hydronic heat pump with propane, it uses a two-stage compressor, a brazed plate indoor heat exchanger, and a microchannel outdoor heat exchanger. It achieves a rated cooling capacity larger than 10 k Watts, and a cooling SEER (cooling seasonal energy efficiency rating) > 16.0 (cooling seasonal COP > 4.7) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP > 2.78), while requiring a system charge < 1200 grams. Additionally, the hydronic heat pump was evaluated in a laboratory water heating loop to heat a 50-gallon water tank in a full condensing mode. Experiments of heating the tank water from 58F(14.4°C) to 150F(65.6°C) were conducted under ambient temperatures from 17F(-8.3°C) to 75F(23.9°C), at the compressor high and low stages.

Shen, Bo↗

Dynamic soil columns simulate Arctic redox biogeochemistry and carbon release during changes in water saturation

Thawing Arctic permafrost can induce hydrologic change and alter redox conditions, shifting the balance of soil organic matter (SOM) decomposition. There remains uncertainty about how soil saturation and redox transitions impact dissolved and gas phase carbon fluxes, and efforts to link hydrobiogeochemical processes to ecosystem-scale models are limited. This study evaluates SOM decomposition of Arctic tundra soils using column experiments, water chemistry measurements, microbial community analysis, and a PFLOTRAN reactive transport model. Soil columns from a thermokarst channel (TC) and an upland tundra (UC) were exposed to cycles of saturation and drainage, which controlled carbon emissions. During saturation, an outflow of dissolved organic carbon from the UC soil correlated with elevated reduced iron and decreased pH; during drainage, UC carbon dioxide fluxes were 70% higher than TC fluxes. Intermittent methane release was observed for TC, consistent with higher methanogen abundance. Slower drainage in the TC soil correlated with more subtle biogeochemical changes. PFLOTRAN simulations captured experimental trends in soil carbon fluxes, oxygen concentrations, and water contents. The model was then used to evaluate additional soil water drainage rates. This study emphasizes the importance of considering hydrologic change when evaluating and simulating SOM decomposition in dynamic Arctic tundra environments.

54 ENVIRONMENTAL SCIENCES↗

Hydrogen Recombiner Catalyst Evaluations for Waste Storage

Radiolysis of water in nuclear waste storage generates hydrogen gas that can accumulate within sludge style waste and be rapidly released during agitation events, creating a significant flammability hazard. Engineering controls are therefore required to limit hydrogen concentrations during both quiescent storage and transient disturbances. Catalytic recombination of hydrogen in waste storage offgas is a proven mitigation strategy, maintaining hydrogen levels below flammability limits and managing sudden concentration spikes. Conventional recombiners rely on platinum and/or palladium catalysts, with development efforts focused on extending service life, increasing active surface area, and ensuring safe deployment in radioactive environments. Savannah River National Laboratory (SRNL) is evaluating a newly developed hydrogen recombiner catalyst from Canadian Nuclear Laboratories as a cost-effective and durable alternative for nuclear waste applications. Testing was conducted in SRNL’s Shielded Cells facility, which enables reduced-scale experimental modeling under radiation fields and near-use-case conditions relevant to radioactive waste storage. Catalyst performance was evaluated using a custom offgas characterization system designed for near-zero flow conditions. The experimental apparatus consisted of a gas-tight 2.7 L PTFE vessel equipped with temperature monitoring, gas flow controls, and a variable-speed mixer to simulate sludge agitation. Offgas composition was monitored using a dedicated gas chromatograph with argon carrier gas and a krypton internal standard. Measurements were obtained for an empty vessel, the vessel containing a well characterized radioactive tank waste sample, and the same configuration with the candidate catalyst installed. Results demonstrate that the new catalyst effectively reduced hydrogen concentrations in the offgas within the constraints of the experimental design. In addition to confirming catalytic activity, the testing provided valuable insights into experimental optimization and considerations for future performance evaluations. These findings support the potential scalability of the technology and highlight its applicability to broader nuclear waste management operations, offering improved safety and reduced operational costs through enhanced catalyst durability and lower replacement frequency.

Tener, Zachary P. [Savannah River National Laborat↗

Life‐cycle greenhouse gas emissions associated with nuclear power generation in the United States

Under the 2022 Inflation Reduction Act, tax credits of up to $3/kgH 2 are available to hydrogen producers if they generate emissions at levels below 0.45 kgCO 2 e/kgH 2 , spurring producers to explore how hydrogen production via electrolysis using electricity generated by nuclear power may qualify for such tax credits. With uranium as a primary fuel for nuclear power plants (NPPs) and no on-site emissions, the upstream emissions associated with nuclear fuel supply chains largely determine the carbon intensity of nuclear energy. Using the GREET (Greenhouse gases, Regulated Emissions, and Energy use in Technologies) model, we evaluated the life-cycle greenhouse gas (GHG) emissions of uranium production and the use of uranium to generate electricity in light water reactor (LWR) NPPs. We evaluated the process chemicals and energy inputs throughout the nuclear fuel supply chain to identify the major contributors to nuclear fuel cycle GHG emissions. Such emissions are estimated at 3.0 gCO 2 e/kWh at NPPs in the United States. The greatest share of nuclear fuel cycle GHG emissions—comprising 53% of total emissions—are associated with electricity consumption throughout the fuel supply chain. We extended the analysis to include an evaluation of the carbon intensity of H 2 production via electrolysis using nuclear power from LWRs. Finally, we examined the impact of future (2035 and 2050) electricity supply chain scenarios on nuclear fuel cycle GHG emissions. Our analysis revealed a decrease of 33% (2035) and 46% (2050) in the carbon intensity of nuclear electricity relative to current nuclear fuel cycle GHG emissions.

greenhouse gas emissions↗

3D Cloud Aerosol Precipitation Experiment at kennaook Cape Grim (3D-CAPE-k) Field Campaign Report

The objective of this campaign was to complement the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s Cloud And Precipitation Experiment at kennaook (CAPE-k) in northwest Tasmania by deploying scanning, fixed pointing angle, and in situ aerosol, cloud, and precipitation remote-sensing instruments during the last six months of the experiment. These instruments provided a three-dimensional (3D) context to the second ARM Mobile Facility (AMF2) vertically pointing observations collected at the kennaook Cape Grim (KCG) site and captured a portion of the life cycle of the clouds before and after the passage over the AMF2 vertical column. These 3D cloud measurements will be used in the near future to 1) investigate how the vertical profiles of aerosol and cloud properties are representative of the broader area and how these properties evolve during the portion of the cloud life cycle captured by the scanning instruments, 2) quantify how accurate the cloud fraction derived with assumptions from vertically pointing observations are compared with direct 3D cloud fraction measurements, 3) evaluate cloud fraction and liquid water path in the Australian Community Climate and Earth-System Simulator–Convective-scale (ACCESS-C) forecast model, and 4) evaluate aerosol and cloud products from the European Space Agency/Japanese Aerospace Exploration Agency (ESA/JAXA) Earth Cloud Aerosol Radiation Explorer (EarthCARE) mission using the scanning measurements, offering more chances of exact collocation, thereby complementing the statistical approach we are planning to employ with AMF2 observations for that same purpose.

54 ENVIRONMENTAL SCIENCES↗

Water isotopes, climate variability, and the hydrological cycle: recent advances and new frontiers

Abstract The hydrologic cycle is a fundamental component of the climate system with critical societal and ecological relevance. Yet gaps persist in our understanding of water fluxes and their response to increased greenhouse gas forcing. The stable isotope ratios of oxygen and hydrogen in water provide a unique opportunity to evaluate hydrological processes and investigate their role in the variability of the climate system and its sensitivity to change. Water isotopes also form the basis of many paleoclimate proxies in a variety of archives, including ice cores, lake and marine sediments, corals, and speleothems. These records hold most of the available information about past hydrologic variability prior to instrumental observations. Water isotopes thus provide a ‘common currency’ that links paleoclimate archives to modern observations, allowing us to evaluate hydrologic processes and their effects on climate variability on a wide range of time and length scales. Building on previous literature summarizing advancements in water isotopic measurements and modeling and describe water isotopic applications for understanding hydrological processes, this topical review reflects on new insights about climate variability from isotopic studies. We highlight new work and opportunities to enhance our understanding and predictive skill and offer a set of recommendations to advance observational and model-based tools for climate research. Finally, we highlight opportunities to better constrain climate sensitivity and identify anthropogenically-driven hydrologic changes within the inherently noisy background of natural climate variability.

Dee, Sylvia (ORCID:000000022140785X)↗

G 0 W 0 Ionization Potentials of First-Row Transition Metal Aqua Ions

Here, we report computations of the vertical ionization potentials within the GW approximation of the near-complete series of first-row transition metal (V–Cu) aqua ions in their most common oxidation states, i.e., V 3+ , Cr 3+ , Cr 2+ , Mn 2+ , Fe 3+ , Fe 2+ , Co 2+ , Ni 2+ , and Cu 2+ . The d-orbital occupancy of these systems spans a broad range from d 2 to d 9 . All of the structures were first optimized at the density functional theory level using a large cluster of explicit water molecules that are embedded in a continuum solvation model. Vertical ionization potentials were computed with the one-shot G 0 W 0 approach on a range of transition metal ion clusters (6, 18, 40, and 60 explicit water molecules), wherein the convergence with respect to the basis set size was evaluated using the systems with 40 water molecules. We assess the results using three different density functional approximations as starting points for the vertical ionization potential calculations, namely, G 0 W 0 @PBE, G 0 W 0 @PBE0, and G 0 W 0 @r 2 SCAN. While the predicted ground-state structures are similar to all three exchange-correlation functionals, the vertical ionization potentials were in closer agreement with experiment when using the G 0 W 0 @PBE0 and G 0 W 0 @r 2 SCAN approaches, with the r 2 SCAN-based calculations being significantly less expensive. Computed bond distances and vertical ionization potentials for all structures are in good agreement with available experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗