Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage support”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Fabrication of anti-adhesion surfaces on aluminium substrates of rubber plastic moulds using electrolysis plasma treatment

An anti-adhesion surface with a water contact angle of 167° was fabricated on aluminium samples of rubber plastic moulds by electrolysis plasma treatment using mixed electrolytes of C{sub 6}H{sub 5}O{sub 7}(NH{sub 4}){sub 3} and Na{sub 2}SO{sub 4}, followed by fluorination. To optimise the fabrication conditions, several important processing parameters such as the discharge voltage, discharge time, concentrations of supporting electrolyte and stearic acid ethanol solution were examined systematically. Using scanning electron microscopy (SEM) to analyse surfaces morphology, micrometer scale pits, and protrusions were found on the surface, with numerous nanometer mastoids contained in the protrusions. These binary micro/nano-scale structures, which are similar to the micro-structures of soil-burrowing animals, play a critical role in achieving low adhesion properties. Otherwise, the anti-adhesion behaviours of the resulting samples were analysed by the atomic force microscope (AFM), Fourier-transform infrared spectrophotometer (FTIR), electrons probe micro-analyzer (EPMA), optical contact angle meter, digital Vickers microhardness (Hv) tester, and electronic universal testing. The results show that the electrolysis plasma treatment does not require complex processing parameters, using a simple device, and is an environment-friendly and effective method. Under the optimised conditions, the contact angle (CA) for the modified anti-adhesion surface is up to 167°, the sliding angle (SA) is less than 2°, roughness of the sample surface is only 0.409μm. Moreover, the adhesion force and H{sub v} are 0. 9KN and 385, respectively.

36 MATERIALS SCIENCE↗

Electricity Distribution System Resilient Control System Metrics

In order to assess the resilience of a system, a set of measures must be defined. Varying control architecture while considering such a system of metrics targeted at resilience can determine the relative merit of the architectures with respect to the resilience of the system. Traditionally, electricity distribution is concerned with delivery of power from transmission or sub transmission to consumer loads with basic control of tap changing transformers and capacitor banks to regulate delivered voltage and provide reactive power support, respectively. In the near future, modern distribution systems architecture are anticipated to include substantially more controllable assets enabling more complicated control architectures to optimized based on reliability and economics. This paper reports on the definition of resilience metrics developed for modern distribution systems for delivery of electricity. Specifically, the metrics are focused on adaptive capacity related to the scale for which the system is able to resist, respond, recover and restore after disturbances in real or reactive power and time requirements to respond and restore the system to a complete normalcy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Placement and Sizing of Inverter-Based Renewable Systems in Multi-Phase Distribution Networks

This study develops a tractable formulation for optimal placement and sizing of inverter-based renewable systems in multi-phase distribution networks. The goal of the formulation is to minimize the cost of inverter installation, average power import, and average distributed generation curtailment. Threephase and single-phase inverter models are presented that preserve the underlying mappings between renewable uncertainty to power injection. The uncertainty of distributed generators (DGs) and loads are characterized by a finite set of scenarios. Linear multi-phase power flow approximations are used in conjunction with scenario reduction techniques to arrive at a tractable twostage stochastic formulation for optimal DG placement and sizing. First-stage decisions are locations for DG deployment and capacity sizes, and second-stage decisions include DG real power curtailment, reactive power support, as well as feeder voltage profile. The resulting formulation is a mixed-integer second-order cone program and can be solved efficiently either by existing optimization solvers or by relaxing the binary variables to the [0,1] interval. Simulation studies on standard multi-phase IEEE test feeders promise that optimal stochastic planning of DGs reduces costs during validation, compared to a scheme where uncertainty is only represented by its average value.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PRELIMINARY TEST RESULTS OF A PROTOTYPE FAST KICKER FOR APS MBA UPGRADE

The APS multi-bend achromatic (MBA) upgrade storage ring plans to support two bunch fill patterns: a 48-bunch and a 324-bunch. A “swap out” injection scheme is required. In order to provide the required kick to injected beam, to minimize the beam loss and residual oscillation of injected beam, and to minimize the perturbation to stored beam during injection, the rise, fall, and flat-top parts of the kicker pulse must be within a 16.9-ns interval. Stripline-type kickers are chosen for both injection and extraction. We developed a prototype kicker that supports a ±15kV differential pulse voltage. We performed high voltage discharge, TDR measurement, high voltage pulse test and beam test of the kicker. We report the final design of the fast kicker and the test results.

APS MBA UPGRADE↗

Development of a reliable Potting process for Photoconductive Semiconductor Switches (PCSS)

Electrical potting is an important process to protect semiconductor devices from damaging external elements (mechanical stress, moisture, high voltage, etc.) and provides structural support for delicate devices for electrical connectivity to a larger platform. This internship will focus on the development of a universal potting jig for photoconductive semiconductor switches (PCSS). The goal is to design a reliable compression jig that is cross compatible with various PCSS designs that allow for easy potting of devices with a high dielectric breakdown strength material. The challenge with the current potting jig is that the design is only compatible with one style of PCSS and applies uneven pressure that can lead to leakage of potting material. Our approach is to move from a design that applies pressure by binder clip to utilizing a micrometer based compressing jig for a reliable packaging process that can pot a variety of devices without having to have a unique compressing jig for each of style of PCSS. Possible roadblocks with the new design include epoxy leakage into the optical path and misalignment of the electrode – metal contact bond.

42 ENGINEERING↗

Programmable Logic Application Notes

This column will be provided each quarter as a source for reliability, radiation results, NASA capabilities, and other information on programmable logic devices and related applications. This quarter the focus is on some experimental data on low voltage drop out regulators to support mixed 5 and 3.3 volt systems. A discussion of the Small Explorer WIRE spacecraft will also be given. Lastly, we show take a first look at robust state machines in Hardware Description Languages (VHDL) and their use in critical systems. If you have information that you would like to submit or an area you would like discussed or researched, please give me a call or e-mail.

Katz, Richard↗

Properly Understanding the Impacts of Distributed Resources on Distribution Systems

The subject paper discusses important impacts of distributed resources on distribution networks and feeders. These include capacity, line losses, voltage regulation, and central system support (such as volt/var via central generators and substation) as the number, placement and penetration levels of distributed resources are varied. Typically, the impacts of distributed resources on the distribution system are studied by using steady-state rather than dynamic analysis tools. However, the response time and transient impacts of both system equipment (such as substation/feeder capacitors) and distributed resources needs to be taken into account and only dynamic analysis will provide the full impact results. ORNL is wrapping up a study of distributed resources interconnected to a large distribution system considering the above variables. A report of the study and its results will be condensed into a paper for this panel session. The impact of distributed resources will vary as the penetration level reaches the capacity of the distribution feeder/system. The question is how high of a penetration of distributed resource can be accommodated on the distribution feeder/system without any major changes to system operation, design and protection. The impacts most surely will vary depending upon load composition, distribution and level. Also, it is expected that various placement of distributed resources will impact the distribution system differently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Durability study of transition metal based non-precious cathode in PEFC

This paper focuses on performance durability of newly developed polyaniline (PANI)-derived non-precious cathode catalyst, whose high oxygen-reduction activity was verified in electrochemical and fuel cell testing, exhibiting onset and half-wave potential (E{sup 1/2}) of oxygen reduction at 0.90 V and 0.77 V, respectively, as well as an insignificant H{sub 2}O{sub 2} yields below 1%. It was found catalyst durability in fuel cell life tests is greatly dependent on the catalyst synthesis including nitrogen precursors, employed transition metals, and supporting materials. Importantly, the working voltages in fuel cell testing have a profound impact on the stability, which much more stable performance can be observed at lower voltage such as 0.4 V when compared with higher voltage, 0.6 V. Preliminary physical and electrochemical characterization present to provide insight into the origin of the possible degradation mechanism for the non-precious active sites.

36 MATERIALS SCIENCE↗

Voltage Restoration in Microgrids using Temporal Logic Specifications

This paper proposes an energy storage controller synthesis method for voltage restoration in microgrids with respect to temporal logic specifications (TLSs). TLSs is introduced in this paper as a formalism to control the voltage variation of a critical bus against an operational bounds over time. The power system with synchronous generator (SG) connected to a critical load bus is modeled as a set of differential-algebraic equations and a simplified analytical model is derived to describe the voltage variation of this critical bus. The control objective is to schedule an optimal control input signal from a supportive energy storage system (ESS) connected to the critical bus, such that the voltage variation of the latter satisfies the TLSs, such as a finite-time restoration. The proposed control is verified on a lumped distribution system model. With this control diagram, supportive controllers can be designed to make voltage behaviors comply with grid codes and avoid unnecessary relay actions.

Taousser, Fatima Zohra↗

Non-flammable electrolyte enables Li-metal batteries with aggressive cathode chemistries

Rechargeable Li-metal batteries using high-voltage cathodes can deliver the highest possible energy densities among all electrochemistries. However, the notorious reactivity of metallic lithium as well as the catalytic nature of high-voltage cathode materials largely prevents their practical application. Here, we report a non-flammable fluorinated electrolyte that supports the most aggressive and high-voltage cathodes in a Li-metal battery. Our battery shows high cycling stability, as evidenced by the efficiencies for Li-metal plating/stripping (99.2%) for a 5 V cathode LiCoPO 4 (-99.81%) and a Ni-rich LiNi 0.8 Mn 0.1 ,Co 0.3 ,O 2 cathode (-99.93%). At a loading of 2.0 mAh cm -2 , our full cells retain -93% of their original capacities after 1,000 cycles. Surface analyses and quantum chemistry calculations show that stabilization of these aggressive chemistries at extreme potentials is due to the formation of a several-nanometre-thick fluorinated interphase.

Fan, Xiulin↗

Control Demonstration of Multiple Doubly Fed Induction Motors for Hybrid Electric Propulsion

The Convergent Aeronautics Solutions (CAS) High Voltage Hybrid Electric Propulsion (HVHEP) activity was formulated to support the move into future hybrid-electric aircraft. The goal of this high-voltage activity is to develop a new alternating current (AC) power architecture to support the needs of higher efficiency and lower emissions aircraft. This proposed architecture will adopt the use of the doubly fed induction machine (DFIM) for propulsor drive motor application. The DFIMs are attractive for several reasons, including but not limited to, the ability to self-start, the ability to operate subsynchronously and supersynchronously, and the requirement for power converters rated at a fraction of those required in a corresponding direct current system, dependent on the range of operation. The focus of this report is based specifically on the presentation and analysis of a novel strategy, which allows for independent operation of multiple doubly fed induction motors from a common AC bus

David J Sadey↗

Aging Effect Analysis of PV Inverter Semiconductors for Ancillary Services Support

PV inverters can provide reactive power while generating active power. An ongoing microgrid implementation at Duke Energy actively engages non-utility PVs to generate/absorb reactive power in support of ancillary services to increase microgrid resiliency during extreme events. PV systems are requested to provide reactive power support: 1) in response to grid voltage variation to better regulate the local voltage; or 2) in response to utility incentives, such as following Transactive Energy System (TES) incentives. However, providing ancillary services might shorten the lifetime expectation of PV inverter semiconductors. This paper summarizes the potential impacts on a PV inverter semiconductor's lifetime when providing ancillary services. The analysis presented in this research work shows that providing reactive power support will increase the mean junction temperature and the junction temperature variation of the inverter diodes. This increased junction temperature will eventually lead to shorter diode lifetime. The lifetime estimation of semiconductors is briefly reviewed. The power losses of PV inverter semiconductors are derived as a support analysis to the junction temperature calculation. In addition, the impact of the filtering inductor on the semiconductor current distribution is discussed. The theoretical analysis presented in this research work is supported by simulation results.

14 SOLAR ENERGY↗

Self similarities in desalination dynamics and performance using capacitive deionization

Charge transfer and mass transport are two underlying mechanisms which are coupled in desalination dynamics using capacitive deionization (CDI). We developed simple reduced-order models based on a mixed reactor volume principle which capture the coupled dynamics of CDI operation using closed-form semi-analytical and analytical solutions. We use the models to identify and explore self-similarities in the dynamics among flow rate, current, and voltage for CDI cell operation including both charging and discharging cycles. The similarity approach identifies the specific combination of cell (e.g. capacitance, resistance) and operational parameters (e.g. flow rate, current) which determine a unique effluent dynamic response. We here demonstrate self-similarity using a conventional flow between CDI (fbCDI) architecture, and we hypothesize that our similarity approach has potential application to a wide range of designs. We performed an experimental study of these dynamics and used well-controlled experiments of CDI cell operation to validate and explore limits of the model. For experiments, we used a CDI cell with five electrode pairs and a standard flow between (electrodes) architecture. Guided by the model, we performed a series of experiments that demonstrate natural response of the CDI system. We also identify cell parameters and operation conditions which lead to self-similar dynamics under a constant current forcing function and perform a series of experiments by varying flowrate, currents, and voltage thresholds to demonstrate self-similarity. Based on this study, we hypothesize that the average differential electric double layer (EDL) efficiency (a measure of ion adsorption rate to EDL charging rate) is mainly dependent on user-defined voltage thresholds, whereas flow efficiency (measure of how well desalinated water is recovered from inside the cell) depends on cell volumes flowed during charging, which is determined by flowrate, current and voltage thresholds. Results of experiments strongly support this hypothesis. Results show that cycle efficiency and salt removal for a given flowrate and current are maximum when average EDL and flow efficiencies are approximately equal. We further explored a range of CC operations with varying flowrates, currents, and voltage thresholds using our similarity variables to highlight trade-offs among salt removal, energy, and throughput performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capacitor-type micrometeoroid detectors

The metal oxide semiconductor (MOS) capacitor micrometeroid detector consists of a thin dielectric capacitor fabricated on a silicon wafer. In operation, the device is charged to a voltage level sufficiently near breakdown that micrometeoroid impacts will cause dielectric deformation or heating and subsequent arc-over at the point of impact. Each detector is capable of recording multiple impacts because of the self-healing characteristics of the device. Support instrumentation requirements consist of a voltage source and pulse counters that monitor the pulse of recharging current following every impact. An investigation has been conducted in which 0.5 to 5 micron diameter carbonized iron spheres traveling at velocities of 4 to 10 Km/sec were impacted on to detectors with either a dielectric thickness of 0.4 or 1.0 micron. This study demonstrated that an ion microprobe tuned to sufficiently high resolution can detect Fe remaining on the detector after the impact. Furthermore, it is also possible to resolve Fe ion images free of mass interferences from Si, for example, giving its spatial distribution after impact. Specifically this technique has shown that significant amounts of impacting particles remain in the crater and near it which can be analyzed for isotopic content. Further testing and calibration could lead to quantitive analysis. This study has shown that the capacitor type micrometeroid detector is capable of not only time and flux measurements but can also be used for isotopic analysis.

Wortman, J. J.↗

The design, construction, and operation of long-distance high-voltage electricity transmission technologies.

This report focuses on transmission lines, which operate at voltages of 115 kV and higher. Currently, the highest voltage lines comprising the North American power grid are at 765 kV. The grid is the network of transmission lines that interconnect most large power plants on the North American continent. One transmission line at this high voltage was built near Chicago as part of the interconnection for three large nuclear power plants southwest of the city. Lines at this voltage also serve markets in New York and New England, also very high demand regions. The large power transfers along the West Coast are generally at 230 or 500 kV. Just as there are practical limits to centralization of power production, there are practical limits to increasing line voltage. As voltage increases, the height of the supporting towers, the size of the insulators, the distance between conductors on a tower, and even the width of the right-of-way (ROW) required increase. These design features safely isolate the electric power, which has an increasing tendency to arc to ground as the voltage (or electrical potential) increases. In addition, very high voltages (345 kV and above) are subject to corona losses. These losses are a result of ionization of the atmosphere, and can amount to several megawatts of wasted power. Furthermore, they are a local nuisance to radio transmission and can produce a noticeable hum. Centralized power production has advantages of economies of scale and special resource availability (for instance, hydro resources), but centralized power requires long-distance transfers of power both to reach customers and to provide interconnections for reliability. Long distances are most economically served at high voltages, which require large-scale equipment and impose a substantial footprint on the corridors through which power passes. The most visible components of the transmission system are the conductors that provide paths for the power and the towers that keep these conductors at a safe distance from each other and from the ground and the natural and built environment. Common elements that are generally less visible (or at least more easily overlooked) include the maintained ROW along the path of the towers, access roads needed for maintenance, and staging areas used for initial construction that may be restored after construction is complete. Also visible but less common elements along the corridor may include switching stations or substations, where lines of similar or different voltages meet to transfer power.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mitigation of Motor Stalling and FIDVR via Energy Storage Systems with Temporal Logic Specifications

The fault-induced delayed voltage recovery (FIDVR) phenomenon has been very common from the distribution system through the transmission system. It causes a delay on recovering significantly depressed local voltage after the fault is cleared, and it can also lead to more widespread cascading system failures. Mitigating this event with current control approaches is challenging and becoming a crucial issue. Here, a model predictive control-based strategy employing signal temporal logic specifications is proposed to help mitigate FIDVR. To this end, it investigates and extends a dynamic performance model allowing analytic insights into the system-wide impact of motor stalling and FIDVR. The proposed controller provides richer descriptions of voltage specifications addressing both magnitude and time simultaneously. We consider different control specifications with reactive power support from energy storage systems to prevent the voltage during/after the fault from dropping too low, and reduce the delay time of voltage recovery. The simulation results conducted with the IEEE 57 bus test network validate the proposed method and demonstrate the effectiveness of the mitigation strategy on FIDVR.

25 ENERGY STORAGE↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

Lithiation of Magnetite (Fe 3 O 4 ): Analysis Using Isothermal Microcalorimetry and Operando X-ray Absorption Spectroscopy

Conversion electrodes, such as magnetite (Fe 3 O 4 ), offer high theoretical capacities (>900 mAh/g) because of multiple electron transfer per metal center. Capacity retention for conversion electrodes has been a challenge in part because of the formation of an insulating surface electrolyte interphase (SEI). This paper provides the first detailed analysis of the lithiation of Fe 3 O 4 using isothermal microcalorimetry (IMC). The measured heat flow was compared with heat contributions predicted from heats of formation for the Faradaic reaction, cell polarization, and entropic contributions. The total measured energy output of the cell (7260 J/g Fe 3 O 4 ) exceeded the heat of reaction predicted for full lithiation of Fe 3 O 4 (5508 J/g). During initial lithiation (3.0–0.86 V), the heat flow was successfully modeled using polarization and entropic contributions. Heat flow at lower voltage (0.86–0.03 V) exceeded the predicted values for iron oxide reduction, consistent with heat generation attributable to electrolyte decomposition and surface electrolyte interphase (SEI). Operando X-ray absorption spectroscopy (XAS) indicated that the oxidation state of the Fe centers deviated from predicted values beginning at ~0.86 V, supportive of SEI onset in this voltage range. Finally and thus, these combined results from electrochemistry, IMC, and XAS indicate parasitic reactions consistent with SEI formation at a moderate voltage and illustrate an approach for deconvoluting Faradaic and non-Faradaic contributions to heat, which should be broadly applicable to the study of energy-storage materials and systems.

25 ENERGY STORAGE↗